Analysis of multiple T2 proton relaxation processes in human head and imaging on the basis of selective and assigned T2 values.

Abstract:

:Two-dimensional T2-selective proton imaging of human head has been performed at 10 MHz employing Carr-Purcell-Gill-Meiboom pulse trains with echo separation of 6 and 12 msec. Using the information of 36 spin echoes and applying a recovery time of 2 sec the magnetization decay has been traced. The multi-exponential T2 relaxation curve of each pixel of the image has been deconvoluted into up to three mono-exponential functions which are defined by 1/T2,i and alpha i. The T2,i values are represented in a T2 histogram of the slice and then selected for generating images which relate to protons with specific T2. The alpha i values indicate the relative amounts of the T2-selected protons. Imaging on the basis of alpha i values increases the contrast of the image. The multiple T2-selective imaging technique leads to head images which show selectively cerebrospinal fluid, gray matter, different types of white matter, and nonassigned fast-relaxing proton classes.

journal_name

Magn Reson Med

authors

Gersonde K,Felsberg L,Tolxdorff T,Ratzel D,Ströbel B

doi

10.1002/mrm.1910010406

subject

Has Abstract

pub_date

1984-12-01 00:00:00

pages

463-77

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

1

pub_type

杂志文章
  • Electromagnetic actuator for generating variably oriented shear waves in MR elastography.

    abstract::Magnetic resonance elastography (MRE) is a recently developed technique for determining the mechanical properties of biological tissue. In dynamic MRE, electromagnetic units (actuators) are widely used to generate shear waves in tissue. These actuators exploit the interaction between the static magnetic field B(0) and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10479

    authors: Braun J,Braun K,Sack I

    更新日期:2003-07-01 00:00:00

  • High resolution hyperpolarized 13 C MRSI using SPICE at 9.4T.

    abstract:PURPOSE:To test the feasibility of using the SPICE (SPectroscopic Imaging by exploiting spatiospectral CorrElation) technique, which uses the partial separability of spectroscopic data, for high resolution hyperpolarized (HP) 13 C spectroscopic imaging. METHODS:Numerical simulations were performed to investigate the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27061

    authors: Lee H,Song JE,Shin J,Joe E,Joo CG,Choi YS,Song HT,Kim DH

    更新日期:2018-08-01 00:00:00

  • Evaluation of coils for imaging histological slides: signal-to-noise ratio and filling factor.

    abstract:PURPOSE:To investigate the relative gain in sensitivity of five histology coils designed in-house to accommodate tissue sections of various sizes and compare with commercial mouse head coils. METHODS:The coil set was tailored to house tissue sections ranging from 5 to1000 µm encased in either glass slides or coverslip...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24841

    authors: Hoang DM,Voura EB,Zhang C,Fakri-Bouchet L,Wadghiri YZ

    更新日期:2014-05-01 00:00:00

  • S5FP: spectrally selective suppression with steady state free precession.

    abstract::A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20633

    authors: Derbyshire JA,Herzka DA,McVeigh ER

    更新日期:2005-10-01 00:00:00

  • Data-driven optimized flip angle selection for T1 estimation from spoiled gradient echo acquisitions.

    abstract:PURPOSE:Define criteria for selection of optimal flip angle sets for T1 estimation and evaluate effects on T1 mapping. THEORY AND METHODS:Flip angle sets for spoiled gradient echo-based T1 mapping were selected by minimizing T1 estimate variance weighted by the joint density of M0 and T1 in an initial acquisition. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25920

    authors: Lewis CM,Hurley SA,Meyerand ME,Koay CG

    更新日期:2016-09-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain.

    abstract::Healthy human brain diffusion anisotropy maps derived from standard spin echo diffusion tensor imaging (DTI) were compared with those using fluid-attenuated inversion recovery (FLAIR) preparation prior to DTI to null the signal from cerebrospinal fluid (CSF). Consistent comparisons entailed development of DTI postproc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10204

    authors: Papadakis NG,Martin KM,Mustafa MH,Wilkinson ID,Griffiths PD,Huang CL,Woodruff PW

    更新日期:2002-08-01 00:00:00

  • Multi-gradient echo with susceptibility inhomogeneity compensation (MGESIC): demonstration of fMRI in the olfactory cortex at 3.0 T.

    abstract::Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (fMRI). However, magnetic susceptibility effects attributed to air-tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370304

    authors: Yang QX,Dardzinski BJ,Li S,Eslinger PJ,Smith MB

    更新日期:1997-03-01 00:00:00

  • Quantitative MRI of Gd-DTPA uptake in tumors: response to photodynamic therapy.

    abstract::A partial saturation method is described for obtaining rapid images of tissue 1H spin-lattice relaxation rates following administration of the paramagnetic contrast agent gadolinium-diethylenetriaminepentaacetate. The paramagnetic contribution to the relaxation rates is proportional to the concentration of contrast ag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310308

    authors: Kennedy SD,Szczepaniak LS,Gibson SL,Hilf R,Foster TH,Bryant RG

    更新日期:1994-03-01 00:00:00

  • Apparent propagator anisotropy from single-shell diffusion MRI acquisitions.

    abstract:PURPOSE:The apparent propagator anisotropy (APA) is a new diffusion MRI metric that, while drawing on the benefits of the ensemble averaged propagator anisotropy (PA) compared to the fractional anisotropy (FA), can be estimated from single-shell data. THEORY AND METHODS:Computation of the full PA requires acquisition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28620

    authors: Aja-Fernández S,Tristán-Vega A,Jones DK

    更新日期:2020-12-13 00:00:00

  • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction.

    abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13

    authors: Pipe JG

    更新日期:1999-10-01 00:00:00

  • Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

    abstract:PURPOSE:Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging meth...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25134

    authors: Celicanin Z,Bieri O,Preiswerk F,Cattin P,Scheffler K,Santini F

    更新日期:2015-02-01 00:00:00

  • Improved selectivity of double quantum coherence filtering for the detection of glutathione in the human brain in vivo.

    abstract::An improved double quantum coherence (DQC) filter for the selective in vivo detection of glutathione (GSH) in the human brain at 1.5 Tesla is presented. The goal was to minimize contamination of the DQC-filtered GSH signal at 2.9 ppm with contributions arising from GABA. The modification consists of tailoring the freq...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1094

    authors: Trabesinger AH,Boesiger P

    更新日期:2001-04-01 00:00:00

  • Coaxial waveguide for travelling wave MRI at ultrahigh fields.

    abstract::At high magnetic fields the performance of a volume-type body coil inside a human sized MR-scanner is influenced by the waveguide action of the scanner's bore. This can result in undesirable strong radio frequency fields B1+) outside the coil's target volume. A radio frequency (RF) transmit system, exploiting this wav...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24496

    authors: Andreychenko A,Kroeze H,Klomp DW,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2013-09-01 00:00:00

  • Constrained length minimum inductance gradient coil design.

    abstract::A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390214

    authors: Chronik BA,Rutt BK

    更新日期:1998-02-01 00:00:00

  • Characterization of estrogen-receptor-targeted contrast agents in solution, breast cancer cells, and tumors in vivo.

    abstract::The estrogen receptor (ER) is a major prognostic biomarker of breast cancer, currently determined in surgical specimens by immunohistochemistry. Two new ER-targeted probes, pyridine-tetra-acetate-Gd chelate (PTA-Gd) conjugated either to 17β-estradiol (EPTA-Gd) or to tamoxifen (TPTA-Gd), were explored as contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24442

    authors: Pais A,Biton IE,Margalit R,Degani H

    更新日期:2013-07-01 00:00:00

  • Anisotropic and restricted diffusion of water in the sciatic nerve: A (2)H double-quantum-filtered NMR study.

    abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>

    authors: Seo Y,Shinar H,Morita Y,Navon G

    更新日期:1999-09-01 00:00:00

  • MR angiography by selective inversion recovery.

    abstract::A modified inversion-recovery sequence is introduced which performs subtraction angiography by varying time-of-flight effects of blood flowing into an imaged slab. The selective 180 degrees excitation inverts different regions between measurements to isolate arterial and/or venous blood. On normal human subjects, high...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040214

    authors: Nishimura DG,Macovski A,Pauly JM,Conolly SM

    更新日期:1987-02-01 00:00:00

  • Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: comparison with H(2)(15)O PET measurements.

    abstract::To detect perfusion abnormalities in areas of high magnetic susceptibility in the brain, an arterial spin-labeling MRI technique utilizing flow-sensitive alternating inversion recovery (FAIR) and half-Fourier single shot turbo spin-echo (HASTE) for spin preparation and image acquisition, respectively, was developed. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0

    authors: Liu HL,Kochunov P,Hou J,Pu Y,Mahankali S,Feng CM,Yee SH,Wan YL,Fox PT,Gao JH

    更新日期:2001-03-01 00:00:00

  • A new approach to Z-spectrum acquisition: prospective baseline enhancement (PROBE) for CEST/Nuclear Overhauser Effect.

    abstract:PURPOSE:To develop a prospective baseline enhancement that compensates for intermingled background effects in Z-spectra to achieve sensitivity enhancement of peaks related to CEST and nuclear Overhauser effect. METHODS:An MRI sequence-specific compensation of background effects is achieved through variation of the pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27555

    authors: Lenich T,Pampel A,Mildner T,Möller HE

    更新日期:2019-04-01 00:00:00

  • The effect of realistic geometries on the susceptibility-weighted MR signal in white matter.

    abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26689

    authors: Xu T,Foxley S,Kleinnijenhuis M,Chen WC,Miller KL

    更新日期:2018-01-01 00:00:00

  • Sweep MRI with algebraic reconstruction.

    abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22516

    authors: Weiger M,Hennel F,Pruessmann KP

    更新日期:2010-12-01 00:00:00

  • Articular cartilage deformation determined in an intact tibiofemoral joint by displacement-encoded imaging.

    abstract::This study demonstrates the in vitro displacement and strain of articular cartilage in a cyclically-compressed and intact joint using displacement-encoded imaging with stimulated echoes (DENSE) and fast spin echo (FSE). Deformation and strain fields exhibited complex and heterogeneous patterns. The displacements in th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21927

    authors: Chan DD,Neu CP,Hull ML

    更新日期:2009-04-01 00:00:00

  • Pulmonary edema induced by allergen challenge in the rat: noninvasive assessment by magnetic resonance imaging.

    abstract::The course of pulmonary edema formation after an intratracheal (i.t.) instillation of ovalbumin was followed noninvasively by magnetic resonance imaging (MRI) in actively sensitized Brown Norway (BN) rats. Changes in edema volume assessed by MRI mimicked the results from the analysis of the number and activation of in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<88::aid-mrm1013>3.0.

    authors: Beckmann N,Tigani B,Ekatodramis D,Borer R,Mazzoni L,Fozard JR

    更新日期:2001-01-01 00:00:00

  • Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

    abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24677

    authors: Mossahebi P,Yarnykh VL,Samsonov A

    更新日期:2014-02-01 00:00:00

  • Kinetic modeling of hyperpolarized (13)C pyruvate metabolism in tumors using a measured arterial input function.

    abstract::Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24546

    authors: Kazan SM,Reynolds S,Kennerley A,Wholey E,Bluff JE,Berwick J,Cunningham VJ,Paley MN,Tozer GM

    更新日期:2013-10-01 00:00:00

  • In vivo MR elastography of the prostate gland using a transurethral actuator.

    abstract::Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22038

    authors: Chopra R,Arani A,Huang Y,Musquera M,Wachsmuth J,Bronskill M,Plewes D

    更新日期:2009-09-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • Improved steering of the RF field of traveling wave MR with a multimode, coaxial waveguide.

    abstract:PURPOSE:Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24807

    authors: Andreychenko A,Kroeze H,Boer VO,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-04-01 00:00:00

  • Diffusion tensor imaging of in vivo and excised rat spinal cord at 7 T with an icosahedral encoding scheme.

    abstract::Regional values of fractional anisotropy (FA) and mean diffusivity (D(av)) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) readout. Based on the water phantom stud...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20304

    authors: Madi S,Hasan KM,Narayana PA

    更新日期:2005-01-01 00:00:00