In vivo multiple-mouse MRI at 7 Tesla.

Abstract:

:We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 3D image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 microm isotropic resolution and the 16 whole fixed mice at 100 microm isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.

journal_name

Magn Reson Med

authors

Bock NA,Nieman BJ,Bishop JB,Mark Henkelman R

doi

10.1002/mrm.20683

subject

Has Abstract

pub_date

2005-11-01 00:00:00

pages

1311-6

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

54

pub_type

杂志文章
  • Per-subject characterization of bolus width in pulsed arterial spin labeling using bolus turbo sampling.

    abstract::Quantification of cerebral blood flow using QUIPSSII pulsed arterial spin labeling requires that the QUIPSS saturation delay TI1 is shorter than the natural temporal bolus width. Yet the duration of the bolus of tagged spins entering the region of interest varies during vasoactive stimuli such as gaseous challenges or...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24412

    authors: Villien M,Chipon E,Troprès I,Bouvier J,Cantin S,Chechin D,Le Bas JF,Krainik A,Warnking JM

    更新日期:2013-06-01 00:00:00

  • Detection of myocardial infarction in the mini-pig using NMR imaging.

    abstract::Spin-echo images of 10 myocardial infarcts in nine mini-pigs were obtained at 30 h, 3 days, and approximately 10 days postinfarction. Infarcts were not detected at all at 30 h in five out of five cases examined. At 3 days postembolization (six cases) one infarct was certainly detected, whilst at 10 days (nine cases) a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050302

    authors: Checkley D,Loveday BE,Waterton JC,Zhu XP,Isherwood I

    更新日期:1987-09-01 00:00:00

  • Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI.

    abstract:PURPOSE:Oscillating gradient (OG) enables the access of short diffusion times for time-dependent diffusion MRI (dMRI); however, it poses several technical challenges for clinical use. This study proposes a 3D oscillating gradient-prepared gradient spin-echo (OGprep-GRASE) sequence to improve SNR and shorten acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28401

    authors: Wu D,Liu D,Hsu YC,Li H,Sun Y,Qin Q,Zhang Y

    更新日期:2021-01-01 00:00:00

  • Myocardial T2* mapping free of distortion using susceptibility-weighted fast spin-echo imaging: a feasibility study at 1.5 T and 3.0 T.

    abstract::This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T2* mapping of the heart. First, T2* maps are presented for oil phantoms ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22054

    authors: Heinrichs U,Utting JF,Frauenrath T,Hezel F,Krombach GA,Hodenius MA,Kozerke S,Niendorf T

    更新日期:2009-09-01 00:00:00

  • In vivo MR imaging and spectroscopy using hyperpolarized 129Xe.

    abstract::Hyperpolarized 129Xe has been used to obtain gas phase images of mouse lung in vivo, showing distinct ventilation variation as a function of the breathing cycle. Spectra of 129Xe in the thorax show complex structure in both the gas phase (-4 to 3 ppm) and tissue-dissolved (190-205 ppm) regions. The alveolar gas peak s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360203

    authors: Wagshul ME,Button TM,Li HF,Liang Z,Springer CS,Zhong K,Wishnia A

    更新日期:1996-08-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Independent component analysis applied to diffusion tensor MRI.

    abstract::The accuracy of the outcome in a diffusion tensor imaging (DTI) experiment depends on the acquisition scheme as well as the postprocessing methods used. In the present study, the DTI results acquired after applying different combinations of diffusion-weighted (DW) gradient orientations were initially compared. Then, s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10046

    authors: Arfanakis K,Cordes D,Haughton VM,Carew JD,Meyerand ME

    更新日期:2002-02-01 00:00:00

  • Rigid-body motion correction with self-navigation MRI.

    abstract::The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21883

    authors: Mendes J,Kholmovski E,Parker DL

    更新日期:2009-03-01 00:00:00

  • Uncovering of intracellular water in cultured cells.

    abstract::The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20565

    authors: Galons JP,Lope-Piedrafita S,Divijak JL,Corum C,Gillies RJ,Trouard TP

    更新日期:2005-07-01 00:00:00

  • Slow magic-angle coil spinning: a high-sensitivity and high-resolution NMR strategy for microscopic biological specimens.

    abstract::High-resolution magic-angle spinning has become a valuable tool to study biologic samples; however, there are only a few high-resolution magic-angle spinning methodologies that have been explored specifically to deal with small semisolid biomaterials such as tissues. Here, we report a novel high-resolution (1)H NMR sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22231

    authors: Wong A,Aguiar PM,Sakellariou D

    更新日期:2010-02-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Volumetric navigators for real-time motion correction in diffusion tensor imaging.

    abstract::Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel techn...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23314

    authors: Alhamud A,Tisdall MD,Hess AT,Hasan KM,Meintjes EM,van der Kouwe AJ

    更新日期:2012-10-01 00:00:00

  • Boron-11 NMR of borocaptate: relaxation and in vivo detection in melanoma-bearing mice.

    abstract::Longitudinal and transverse relaxation rates for the 11B resonances in sodium borocaptate (BSH) at varying concentrations were measured in undiluted horse serum in a 4.7 Tesla field. The results could be fit by a model that assumes fast exchange of the BSH molecule between a free and a bound state, using values of 0.7...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390314

    authors: Bendel P,Frantz A,Zilberstein J,Kabalka GW,Salomon Y

    更新日期:1998-03-01 00:00:00

  • B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    abstract:PURPOSE:Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26790

    authors: Weavers PT,Tao S,Trzasko JD,Frigo LM,Shu Y,Frick MA,Lee SK,Foo TK,Bernstein MA

    更新日期:2018-03-01 00:00:00

  • Pulsatile flow artifacts in 3D magnetic resonance imaging.

    abstract::Some of the important features of how pulsatile flow generates artifacts in three-dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300305

    authors: Frank LR,Buxton RB,Kerber CW

    更新日期:1993-09-01 00:00:00

  • Hypercarbia-induced changes in cerebral blood volume in the cat: a 1H MRI and intravascular contrast agent study.

    abstract::Cerebral blood volume changes with arterial carbon dioxide were monitored by proton T1-weighted MR images following administration of the intravascular contrast agent Gd-DTPA labeled with human serum albumin. Without MR contrast, no significant image intensity changes were observed with PaCO2. Following contrast, regi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230104

    authors: Moseley ME,Chew WM,White DL,Kucharczyk J,Litt L,Derugin N,Dupon J,Brasch RC,Norman D

    更新日期:1992-01-01 00:00:00

  • Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle.

    abstract:PURPOSE:To establish a series of relationships defining how muscle microstructure and diffusion tensor imaging (DTI) are related. METHODS:The relationship among key microstructural features of skeletal muscle (fiber size, fibrosis, edema, and permeability) and the diffusion tensor were systematically simulated over ph...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26993

    authors: Berry DB,Regner B,Galinsky V,Ward SR,Frank LR

    更新日期:2018-07-01 00:00:00

  • 3D-multi-spectral T2 mapping near metal implants.

    abstract:PURPOSE:Due to host-mediated adverse reaction to metallic debris, there is an increasing need for noninvasive assessment of the soft tissue surrounding large joint arthroplasties. Quantitative T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27744

    authors: Bhave S,Koff MF,Sivaram Kaushik S,Potter HG,Koch KM

    更新日期:2019-08-01 00:00:00

  • Comparison of measuring energy metabolism by different (31) P-magnetic resonance spectroscopy techniques in resting, ischemic, and exercising muscle.

    abstract::Alternate methods to quantify mitochondrial activity or function have been extensively used for studying insulin resistance and type 2 diabetes mellitus, namely saturation transfer and phosphocreatine (PCr) recovery. As these methods are in fact determining different parameters, this study aimed to compare saturation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23095

    authors: Schmid AI,Schrauwen-Hinderling VB,Andreas M,Wolzt M,Moser E,Roden M

    更新日期:2012-04-01 00:00:00

  • Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.

    abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21074

    authors: Jin T,Zhao F,Kim SG

    更新日期:2006-12-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Fully automated patellofemoral MRI segmentation using holistically nested networks: Implications for evaluating patellofemoral osteoarthritis, pain, injury, pathology, and adolescent development.

    abstract:PURPOSE:Our clinical understanding of the relationship between 3D bone morphology and knee osteoarthritis, as well as our ability to investigate potential causative factors of osteoarthritis, has been hampered by the time-intensive nature of manually segmenting bone from MR images. Thus, we aim to develop and validate ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27920

    authors: Cheng R,Alexandridi NA,Smith RM,Shen A,Gandler W,McCreedy E,McAuliffe MJ,Sheehan FT

    更新日期:2020-01-01 00:00:00

  • Accelerating sequences in the presence of metal by exploiting the spatial distribution of off-resonance.

    abstract:PURPOSE:To demonstrate feasibility of exploiting the spatial distribution of off-resonance surrounding metallic implants for accelerating multispectral imaging techniques. THEORY AND METHODS:Multispectral imaging (MSI) techniques perform time-consuming independent three-dimensional acquisitions with varying radio freq...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25087

    authors: Smith MR,Artz NS,Koch KM,Samsonov A,Reeder SB

    更新日期:2014-12-01 00:00:00

  • Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners.

    abstract:PURPOSE:This study aims to identify work-related and personal factors associated with workers' exposure to static magnetic fields (SMF) and motion-induced time-varying magnetic fields (TVMF) from MRI scanners. METHODS:Measurements of personal exposure to SMF and TVMF were performed among MRI staff during 439 work shif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25720

    authors: Schaap K,Christopher-De Vries Y,Cambron-Goulet É,Kromhout H

    更新日期:2016-05-01 00:00:00

  • Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25101

    authors: Powell NJ,Jang A,Park JY,Valette J,Garwood M,Marjańska M

    更新日期:2015-01-01 00:00:00

  • Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    abstract:PURPOSE:Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left vent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26312

    authors: Huelnhagen T,Hezel F,Serradas Duarte T,Pohlmann A,Oezerdem C,Flemming B,Seeliger E,Prothmann M,Schulz-Menger J,Niendorf T

    更新日期:2017-06-01 00:00:00

  • Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    abstract:PURPOSE:Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine data...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26923

    authors: Odille F,Bustin A,Liu S,Chen B,Vuissoz PA,Felblinger J,Bonnemains L

    更新日期:2018-05-01 00:00:00

  • Analysis and correction of motion artifacts in diffusion weighted imaging.

    abstract::For diffusion-weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero- and first-order, respectively, in position. While a navigator echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320313

    authors: Anderson AW,Gore JC

    更新日期:1994-09-01 00:00:00

  • MR imaging with hyperpolarized 3He gas.

    abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330219

    authors: Middleton H,Black RD,Saam B,Cates GD,Cofer GP,Guenther R,Happer W,Hedlund LW,Johnson GA,Juvan K

    更新日期:1995-02-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00