Abstract:
PURPOSE:Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine datasets; reformatted slices are then used to optimize the manual segmentation workflow. METHODS:Isotropic 3D cine datasets were obtained from multiple 2D cine stacks (acquired during free-breathing in SAX and long-axis (LAX) orientations) using nonrigid motion correction (cine-GRICS method) and super-resolution. Several manual segmentation strategies were then compared, including conventional SAX segmentation, LAX segmentation in three views only, and combinations of SAX and LAX slices. An implicit B-spline surface reconstruction algorithm is proposed to reconstruct the left ventricular cavity surface from the sparse set of 2D contours. RESULTS:All tested sparse segmentation strategies were in good agreement, with Dice scores above 0.9 despite using fewer slices (3-6 sparse slices instead of 8-10 contiguous SAX slices). When compared to independent phase-contrast flow measurements, stroke volumes computed from four or six sparse slices had slightly higher precision than conventional SAX segmentation (error standard deviation of 5.4 mL against 6.1 mL) at the cost of slightly lower accuracy (bias of -1.2 mL against 0.2 mL). Functional parameters also showed a trend to improved precision, including end-diastolic volumes, end-systolic volumes, and ejection fractions). CONCLUSION:The postprocessing workflow of 3D isotropic cardiac imaging strategies can be optimized using sparse segmentation and 3D surface reconstruction. Magn Reson Med 79:2665-2675, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Odille F,Bustin A,Liu S,Chen B,Vuissoz PA,Felblinger J,Bonnemains Ldoi
10.1002/mrm.26923subject
Has Abstractpub_date
2018-05-01 00:00:00pages
2665-2675issue
5eissn
0740-3194issn
1522-2594journal_volume
79pub_type
杂志文章abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26730
更新日期:2018-02-01 00:00:00
abstract::The investigation of flow behavior in coronary arteries is of great importance for an understanding of heart failure and heart regulation mechanisms. The purpose of the present study was to demonstrate that flow velocity can be quantified in the coronary arteries of the isolated rat heart with high-resolution phase co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10563
更新日期:2003-09-01 00:00:00
abstract::Detre et al. (Magn. Reson. Med. 23, 37-45 (1992)) and Zhang et al., (Magn. Reson. Med. 25, 362 (1992)) have recently demonstrated a technique for the measurement of regional cerebral blood flow (rCBF) based on the continuous saturation (or inversion) of the arterial blood supply to the brain in rats at 4.7 T. In the w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910310208
更新日期:1994-02-01 00:00:00
abstract::Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography. Unfortunately, this technique is particularly sensitive to oblique flow in the imaging plane. In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presente...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1084
更新日期:2001-04-01 00:00:00
abstract::A single-shot, two-echo method for the simultaneous detection of multiple-quantum (MQ)-filtered gamma-aminobutyric acid (GABA) and creatine (Cr) was developed and demonstrated in the human brain in vivo at 3 Tesla. The simultaneously measured Cr singlet served as a navigator for the spectral phase of GABA and any freq...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20082
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:Spectrally selective "prewinding" radiofrequency pulses can counteract B0 inhomogeneity in steady-state sequences, but can only prephase a limited range of off-resonance. We propose spectral-spatial small-tip angle prewinding pulses that increase the off-resonance bandwidth that can be successfully prephased by...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26794
更新日期:2018-03-01 00:00:00
abstract::In this work we aimed to study the possibility of using supervised classifiers to quantify the main components of carotid atherosclerotic plaque in vivo on the basis of multisequence MRI data. MRI data consisting of five MR weightings were obtained from 25 symptomatic subjects. Histological micrographs of endarterecto...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20828
更新日期:2006-04-01 00:00:00
abstract::A proton NMR relaxation and pulsed field gradient self-diffusion study of water in fibrin gels, plasma, and blood clots has been performed with special emphasis on the effect of the sol-gel and shrinkage transitions. Deuteron NMR in fibrin gels was also studied to supplement the proton data. It is shown that a measure...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910140111
更新日期:1990-04-01 00:00:00
abstract:PURPOSE:Banding artifacts in images acquired by balanced steady-state free precession (bSSFP) remain a challenge in MRI as they considerably reduce image quality, and diagnostic value deteriorates accordingly. As the steady-state tolerates small shifts in frequency, it is possible to acquire frequency-modulated bSSFP. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26630
更新日期:2017-12-01 00:00:00
abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21079
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:As the premiere modality for brain imaging, MRI could find wider applicability if lightweight, portable systems were available for siting in unconventional locations such as intensive care units, physician offices, surgical suites, ambulances, emergency rooms, sports facilities, or rural healthcare sites. METH...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25147
更新日期:2015-02-01 00:00:00
abstract::A novel method for reducing the rf power requirements of selective pulses employed for z magnetization slice inversion in localized NMR spectroscopy is presented. Following slice preparation by the use of frequency-incremented sinc pulses, the slice gradient is reduced, which narrows the frequency width of the slice. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050610
更新日期:1987-12-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26885
更新日期:2018-04-01 00:00:00
abstract::It is demonstrated that a high-resolution (1)H NMR spectrum of excised rat liver can be obtained using the technique of magic angle turning (MAT) at a sample spinning rate of 1 Hz. A variant of the phase-corrected MAT (PHORMAT) pulse sequence that includes a water suppression segment was developed for the investigatio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10139
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues by means of the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28083
更新日期:2020-06-01 00:00:00
abstract::A number of techniques that recently have been used for fast NMR-imaging are based on a hybrid sequence of echo planar imaging (EPI) and FLASH imaging: after each NMR excitation several k-space lines are measured. The complete k-space is covered by performance of several excitations. It has been observed that there is...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910340328
更新日期:1995-09-01 00:00:00
abstract:PURPOSE:Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26361
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:To assess the blood-tissue distribution of hyperpolarized (13) C-labeled molecules in vivo. METHODS:Spin-echo experiments with simultaneous acquisition of the free induction decay (FID) signal following the excitation pulse and the spin-echo signal, were used to monitor hyperpolarized [1-(13) C]lactate, [1-(13...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24591
更新日期:2013-11-01 00:00:00
abstract::High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc fi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030108
更新日期:1986-02-01 00:00:00
abstract::Advances in modern magnetic resonance imaging (MRI) pulse sequences have enabled clinically practical cortical bone imaging. Human cortical bone is known to contain a distribution of T(1) and T(2) components attributed to bound and pore water, although clinical imaging approaches have yet to discriminate bound from po...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24186
更新日期:2012-12-01 00:00:00
abstract::Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18
更新日期:1999-09-01 00:00:00
abstract::This work presents a method applied to the design of short self-shielded gradient coils of cylindrical geometry. The method uses a hybrid technique that combines the simulated annealing and target field methods to optimize the standard stream functions. The optimized stream functions were parameterized using a few deg...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200103)45:3<505::aid-mrm1066>3.0
更新日期:2001-03-01 00:00:00
abstract::Proton T(1rho)-dispersion MRI is demonstrated for indirect, in vivo detection of (17)O in the brain. This technique, which may be readily implemented on any clinical MRI scanner, is applied towards high-resolution, quantitative mapping of cerebral blood flow (CBF) in the rat by monitoring the clearance of (17)O-enrich...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10403
更新日期:2003-03-01 00:00:00
abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4
更新日期:1999-06-01 00:00:00
abstract:PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27439
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:To develop and evaluate a method for RF envelope correction without extra hardware or synchronization. METHODS:Transmitted RF waveforms are measured through a simple pulse sequence called the gradient reversal approach to evaluate RF (GRATER). The measured RF waveforms are used to compute predistorted RF wavef...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27930
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:Chemical exchange saturation transfer (CEST) MRI has shown promise in tissue characterization in diseases like stroke and tumor. However, in vivo CEST imaging such as amide proton transfer (APT) MRI is challenging because of concomitant factors such as direct water saturation, macromolecular magnetization trans...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26959
更新日期:2017-12-01 00:00:00
abstract::Each k-space segment in multishot diffusion-weighted MRI is affected by a different spatially varying phase which is caused by unavoidable motions and amplified by the diffusion-encoding gradients. A proper image reconstruction therefore requires phase maps for each segment. Such maps are commonly derived from two-dim...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22126
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26903
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24677
更新日期:2014-02-01 00:00:00