Improved device definition in interventional magnetic resonance imaging using a rotated stripes keyhole acquisition.

Abstract:

:Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] could be achieved by rotating the keyhole pattern in k-space so that the read out direction lies perpendicular to the device orientation in real space. This study seeks to validate the earlier predictions of improved efficacy of a rotated stripes keyhole acquisition in actual in vitro and in vivo interventional MR imaging procedures. A true-FISP sequence was modified to perform central stripes keyhole (as known as conventional keyhole) acquisitions after a full initial reference data set was acquired. The gradients of this sequence were then modified to rotate the k-space definition and the keyhole stripes by 10 degrees, 20 degrees, 30 degrees, 45 degrees, and 60 degrees from their conventional k-space orientation. Acquisitions were performed during insertion of interventional devices in phantom and in vivo RF ablation procedures, using the modified sequence selected which placed the phase encoding axis at parallel and perpendicular orientations to the devices. Resulting images were compared between the two orientations for needle width and tip accuracy. Apparent needle width was thinner and tip position more accurately determined for placement of phase encoding parallel to the needle in all cases. Rotated keyhole imaging provides the required temporal advantage of conventional keyhole imaging along with a near optimal definition of an interventional device when the phase encoding is oriented parallel to the direction of the needle motion. Magn Reson Med 42:554-560, 1999.

journal_name

Magn Reson Med

authors

Hwang KP,Lim J,Wendt M,Merkle E,Lewin JS,Duerk JL

doi

10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18

subject

Has Abstract

pub_date

1999-09-01 00:00:00

pages

554-60

issue

3

eissn

0740-3194

issn

1522-2594

pii

10.1002/(SICI)1522-2594(199909)42:3<554::AID-MRM18

journal_volume

42

pub_type

杂志文章
  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • Is the detection of fucose cancer markers by 2D 1H NMR unequivocal?

    abstract::Fucose is believed to be a marker for cancer that may be detectable by the 2D proton NMR (COSY) of human plasma. However, the COSY technique is time consuming and prone to error. These problems may be alleviated by using the SUPERCOSY pulse sequence; this technique shows that there are many other cross peaks in the re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150102

    authors: Phillips PS,Herring FG

    更新日期:1990-07-01 00:00:00

  • Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences.

    abstract::The fast spin-echo (FSE) sequence is frequently used as a fast data-readout technique in conjunction with other pulse sequence elements, such as in fluid-attenuated inversion-recovery (FLAIR) and double inversion-recovery (DIR) sequences. In order to implement those pulse sequences, an understanding is required of how...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20541

    authors: Meara SJ,Barker GJ

    更新日期:2005-07-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • Local specific absorption rate in brain tumors at 7 tesla.

    abstract:PURPOSE:MR safety at 7 Tesla relies on accurate numerical simulations of transmit electromagnetic fields to fully assess local specific absorption rate (SAR) safety. Numerical simulations for SAR safety are currently performed using models of healthy patients. These simulations might not be useful for estimating SAR in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25653

    authors: Restivo MC,van den Berg CA,van Lier AL,Polders DL,Raaijmakers AJ,Luijten PR,Hoogduin H

    更新日期:2016-01-01 00:00:00

  • In vivo multiple-mouse MRI at 7 Tesla.

    abstract::We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20683

    authors: Bock NA,Nieman BJ,Bishop JB,Mark Henkelman R

    更新日期:2005-11-01 00:00:00

  • High-resolution Fourier-encoded sub-millisecond echo time musculoskeletal imaging at 3 Tesla and 7 Tesla.

    abstract:PURPOSE:The feasibility of imaging musculoskeletal fibrous tissue components, such as menisci, ligaments, and tendons, with a conventional spoiled gradient echo technique is explored in vivo at 3 T and 7 T. METHODS:To this end, the echo time (TE1 ) of a conventional Fourier-encoded multicontrast three-dimensional SGPR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24578

    authors: Deligianni X,Bär P,Scheffler K,Trattnig S,Bieri O

    更新日期:2013-11-01 00:00:00

  • Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart.

    abstract::Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadolinium-DTPA (Gd-DTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudinal relaxation rate, and could t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1188

    authors: Larsson HB,Rosenbaum S,Fritz-Hansen T

    更新日期:2001-08-01 00:00:00

  • Use of high temperature superconductor in a receiver coil for magnetic resonance imaging.

    abstract::A planar YBa2Cu3Ox (YBCO) coil has been used as a pick-up coil in a nuclear magnetic resonance imager. It was found that the quality factor (Q) of the YBCO coil was greater than its copper counterpart by approaching 50% even in a field of 0.15 T. The Q of the copper coil at 77 K and in a field of 0.15 T was 1200 while...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200218

    authors: Hall AS,Alford NM,Button TW,Gilderdale DJ,Gehring KA,Young IR

    更新日期:1991-08-01 00:00:00

  • Liver stiffness assessment by tagged MRI of cardiac-induced liver motion.

    abstract::Cirrhosis is an important and growing public health problem, affecting millions of Americans and many more people internationally. A pathological hallmark of the progression to cirrhosis is the development of liver fibrosis, so that monitoring the appearance and progression of liver fibrosis can be used to guide thera...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22785

    authors: Chung S,Breton E,Mannelli L,Axel L

    更新日期:2011-04-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • Improved data reconstruction method for GRAPPA.

    abstract::This paper presents an improved data reconstruction method for generalized autocalibrating partially parallel acquisitions (GRAPPA) using multicolumn multiline interpolation (MCMLI). Both nearest acquired line (ky) neighboring points and column (kx) neighboring points from all components of an array coil were used to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20601

    authors: Wang Z,Wang J,Detre JA

    更新日期:2005-09-01 00:00:00

  • Strain-dependent T1 relaxation profiles in articular cartilage by MRI at microscopic resolutions.

    abstract::To investigate the dependency of T(1) relaxation on mechanical strain in articular cartilage, quantitative magnetic resonance T(1) imaging experiments were carried out on cartilage before/after the tissue was immersed in gadolinium contrast agent and when the tissue was being compressed (up to ∼ 48% strains). The spat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22933

    authors: Xia Y,Wang N,Lee J,Badar F

    更新日期:2011-06-01 00:00:00

  • Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla.

    abstract:PURPOSE:To characterize and optimize 19 F MRI for different perfluorocarbons (PFCs) at 3T and quantify the loss of acquisition efficiency as a function of different temperature and cellular conditions. METHODS:The T1 and T2 relaxation times of the commonly used PFCs perfluoropolyether (PFPE), perfluoro-15-crown-5-ethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26317

    authors: Colotti R,Bastiaansen JAM,Wilson A,Flögel U,Gonzales C,Schwitter J,Stuber M,van Heeswijk RB

    更新日期:2017-06-01 00:00:00

  • Pulmonary edema induced by allergen challenge in the rat: noninvasive assessment by magnetic resonance imaging.

    abstract::The course of pulmonary edema formation after an intratracheal (i.t.) instillation of ovalbumin was followed noninvasively by magnetic resonance imaging (MRI) in actively sensitized Brown Norway (BN) rats. Changes in edema volume assessed by MRI mimicked the results from the analysis of the number and activation of in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<88::aid-mrm1013>3.0.

    authors: Beckmann N,Tigani B,Ekatodramis D,Borer R,Mazzoni L,Fozard JR

    更新日期:2001-01-01 00:00:00

  • Dynamic glucose-enhanced (DGE) MRI in the human brain at 7 T with reduced motion-induced artifacts based on quantitative R1ρ mapping.

    abstract:PURPOSE:Dynamic glucose-enhanced (DGE)-MRI based on chemical exchange-sensitive MRI, that is, glucoCEST and gluco-chemical exchange-sensitive spin-lock (glucoCESL), is intrinsically prone to motion-induced artifacts because the final DGE contrast relies on the difference of images, which were acquired with a time gap o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28112

    authors: Boyd PS,Breitling J,Zimmermann F,Korzowski A,Zaiss M,Schuenke P,Weinfurtner N,Schlemmer HP,Ladd ME,Bachert P,Paech D,Goerke S

    更新日期:2020-07-01 00:00:00

  • Single-scan MRI with exceptional resilience to field heterogeneities.

    abstract:PURPOSE:Single-scan two-dimensional MRI has been generally constrained to acquisitions in high quality magnets. This study introduces a methodology, cross-term spatiotemporal encoding (xSPEN), that delivers such images under much poorer external field conditions. METHODS:xSPEN departs from conventional k-space scannin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26145

    authors: Zhang Z,Seginer A,Frydman L

    更新日期:2017-02-01 00:00:00

  • Novel quadrature birdcage coil for a vertical B(0) field open MRI system.

    abstract::A birdcage coil possesses various intrinsic resonant modes. One of the modes produces sinusoidal current distribution around the rung elements of the birdcage and generates a highly uniform B(1) field in the transverse plane. Another mode is the end-ring resonant mode, in which there are no currents in the rungs of th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<633::aid-mrm18>3.0.c

    authors: Fujita H,Braum WO,Morich MA

    更新日期:2000-10-01 00:00:00

  • A double-tuned probe for metabolic NMR studies.

    abstract::A double-tuned single coil probe for high field metabolic NMR studies has been designed and tested. The resonant coil is a single-turn of copper foil wound on a quartz cylinder. It is fed by a short length of parallel strip line made of the same material; the feeder is also used as a tuning capacitance. Electrical par...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230216

    authors: Najim E,Grivet JP

    更新日期:1992-02-01 00:00:00

  • An evaluation of the effect of fasting on the exercise-induced changes in pH and Pi/PCr from skeletal muscle.

    abstract::The changes in the response of skeletal muscle to maximal dynamic exercise were investigated in going from a fasted state to a refed state by means of 31P NMR spectroscopy. It was found that in the fasted state, exercise-induced changes in Pi/PCr and in pH were both inhibited, in comparison with those in the refed sta...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030616

    authors: Lunt JA,Allen PS,Brauer M,Swinamer D,Treiber EO,Belcastro A,Eccles R,King EG

    更新日期:1986-12-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00

  • Regional and temporal variations in tissue sodium concentration during the acute stroke phase.

    abstract::A technique for noninvasively quantifying the concentration of sodium ((23) Na) ions was applied to the study of ischemic stroke. (23) Na-magnetic resonance imaging techniques have shown considerable potential for measuring subtle changes in ischemic tissue, although studies to date have suffered primarily from poor s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23031

    authors: Wetterling F,Gallagher L,Macrae IM,Junge S,Fagan AJ

    更新日期:2012-03-01 00:00:00

  • Decomposed direct matrix inversion for fast non-cartesian SENSE reconstructions.

    abstract::A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20974

    authors: Qian Y,Zhang Z,Wang Y,Boada FE

    更新日期:2006-08-01 00:00:00

  • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

    abstract::The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20440

    authors: Steger TR,White RA,Jackson EF

    更新日期:2005-04-01 00:00:00

  • High-resolution slice-selective Fourier velocity encoding in congenital heart disease using spiral SENSE with velocity unwrap.

    abstract::Quantification of peak velocity is important in the assessment of stenotic flow jets in patients with congenital heart disease. Phase-contrast magnetic resonance underestimates peak velocities. Hence, clinically Doppler ultrasound is used as the reference standard for assessing stenoses. It is possible to accurately m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24293

    authors: Steeden JA,Jones A,Pandya B,Atkinson D,Taylor AM,Muthurangu V

    更新日期:2012-06-01 00:00:00

  • Three-dimensional MRI with an undersampled spherical shells trajectory.

    abstract::The shells trajectory is a 3D data acquisition method with improved efficiency compared to Cartesian sampling. It is a true center-out trajectory that does not repeatedly resample the center of k-space, and also offers advantages for motion correction. This work demonstrates that k-space undersampling can be combined ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20977

    authors: Shu Y,Riederer SJ,Bernstein MA

    更新日期:2006-09-01 00:00:00

  • Single-breath clinical imaging of hyperpolarized (129)Xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1-point Dixon acquisition.

    abstract:PURPOSE:We sought to develop and test a clinically feasible 1-point Dixon, three-dimensional (3D) radial acquisition strategy to create isotropic 3D MR images of (129)Xe in the airspaces, barrier, and red blood cells (RBCs) in a single breath. The approach was evaluated in healthy volunteers and subjects with idiopathi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25675

    authors: Kaushik SS,Robertson SH,Freeman MS,He M,Kelly KT,Roos JE,Rackley CR,Foster WM,McAdams HP,Driehuys B

    更新日期:2016-04-01 00:00:00

  • T2 of endotoxin lung injury with and without methylprednisolone treatment.

    abstract::NMR relaxation times (T1 and T2) and the water content (WC) of in vitro rat lungs were measured during the course of endotoxin lung injury in rats. Measurements of normal lungs, untreated endotoxin-injured lungs, and endotoxin-injured lungs treated with methylprednisolone (MPSL) were compared. The untreated endotoxin ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150204

    authors: Shioya S,Haida M,Tsuji C,Ono Y,Miyairi A,Fukuzaki M,Ohta Y,Yamabayashi H

    更新日期:1990-08-01 00:00:00

  • Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    abstract:PURPOSE:Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine data...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26923

    authors: Odille F,Bustin A,Liu S,Chen B,Vuissoz PA,Felblinger J,Bonnemains L