Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI.

Abstract:

PURPOSE:Oscillating gradient (OG) enables the access of short diffusion times for time-dependent diffusion MRI (dMRI); however, it poses several technical challenges for clinical use. This study proposes a 3D oscillating gradient-prepared gradient spin-echo (OGprep-GRASE) sequence to improve SNR and shorten acquisition time for OG dMRI on clinical scanners. METHODS:The 3D OGprep-GRASE sequence consisted of global saturation, diffusion encoding, fat saturation, and GRASE readout modules. Multiplexed sensitivity-encoding reconstruction was used to correct the phase errors between multiple shots. We compared the scan time and SNR of the proposed sequence and the conventional 2D-EPI sequence for OG dMRI at 30-90-mm slice coverage. We also examined the time-dependent diffusivity changes with OG dMRI acquired at frequencies of 50 Hz and 25 Hz and pulsed-gradient dMRI at diffusion times of 30 ms and 60 ms. RESULTS:The OGprep-GRASE sequence reduced the scan time by a factor of 1.38, and increased the SNR by 1.74-2.27 times compared with 2D EPI for relatively thick slice coverage (60-90 mm). The SNR gain led to improved diffusion-tensor reconstruction in the multishot protocols. Image distortion in 2D-EPI images was also reduced in GRASE images. Diffusivity measurements from the pulsed-gradient dMRI and OG dMRI showed clear diffusion-time dependency in the white matter and gray matter of the human brain, using both the GRASE and EPI sequences. CONCLUSION:The 3D OGprep-GRASE sequence improved scan time and SNR and reduced image distortion compared with the 2D multislice acquisition for OG dMRI on a 3T clinical system, which may facilitate the clinical translation of time-dependent dMRI.

journal_name

Magn Reson Med

authors

Wu D,Liu D,Hsu YC,Li H,Sun Y,Qin Q,Zhang Y

doi

10.1002/mrm.28401

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

78-88

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

85

pub_type

杂志文章
  • Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

    abstract::For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24440

    authors: Feng L,Srichai MB,Lim RP,Harrison A,King W,Adluru G,Dibella EV,Sodickson DK,Otazo R,Kim D

    更新日期:2013-07-01 00:00:00

  • A modified sub-second fast-STEAM sequence incorporating bipolar gradients for in vivo diffusion imaging.

    abstract::A modified high-speed stimulated-echo acquisition mode (STEAM) diffusion sequence (90 degrees-TE/2-90 degrees-TM-[alpha-TE/2-STE]n) incorporating bipolar diffusion gradients that are less sensitive to macroscopic motion-induced artifacts is presented. Diffusion encoding was performed only during the first echo interva...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350620

    authors: Yongbi MN,Ding S,Dunn JF

    更新日期:1996-06-01 00:00:00

  • Biodegradable, polymer encapsulated, metal oxide particles for MRI-based cell tracking.

    abstract::Metallic particles have shaped the use of magnetic resonance imaging (MRI) for molecular and cellular imaging. Although these particles have generally been developed for extracellular residence, either as blood pool contrast agents or targeted contrast agents, the coopted use of these particles for intracellular label...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.25263

    authors: Shapiro EM

    更新日期:2015-01-01 00:00:00

  • Hormonally induced modulation in the phosphate metabolites of breast cancer: analysis of in vivo 31P MRS signals with a modified prony method.

    abstract::A modified Prony method (MPM) was applied to analyze the main signals present in spatially resolved 31P NMR spectra of MCF7 breast tumors implanted in nude mice. First, the method was tested on synthetic data to establish its limits of reliability. Its performance with respect to peak identification and quantification...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380219

    authors: Viti V,Ragona R,Guidoni L,Barone P,Furman E,Degani H

    更新日期:1997-08-01 00:00:00

  • Molecular imaging of angiogenic therapy in peripheral vascular disease with alphanubeta3-integrin-targeted nanoparticles.

    abstract::Noninvasive molecular imaging of angiogenesis could play a critical role in the clinical management of peripheral vascular disease patients. The alpha(nu)beta(3)-integrin, a well-established biomarker of neovascular proliferation, is an ideal target for molecular imaging of angiogenesis. This study investigates whethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22447

    authors: Winter PM,Caruthers SD,Allen JS,Cai K,Williams TA,Lanza GM,Wickline SA

    更新日期:2010-08-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Total removal of unwanted harmonic peaks (TruHARP) MRI for single breath-hold high-resolution myocardial motion and strain quantification.

    abstract::Current MRI methods for myocardial motion and strain quantification have limited resolution because of Fourier space spectral peak interference. Methods have been proposed to remove this interference in order to improve resolution; however, these methods are clinically impractical due to the prolonged imaging times. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22403

    authors: Agarwal HK,Prince JL,Abd-Elmoniem KZ

    更新日期:2010-08-01 00:00:00

  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • MR-guided interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe.

    abstract::The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390304

    authors: Tacke J,Adam G,Speetzen R,Brucksch K,Bücker A,Heshel I,Prescher A,van Vaals JJ,Hunter DW,Rau G,Günther RW

    更新日期:1998-03-01 00:00:00

  • Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

    abstract::A novel radio-frequency (RF) pulse design algorithm is presented that generates fast slice-selective excitation pulses that mitigate B+1 inhomogeneity present in the human brain at high field. The method is provided an estimate of the B+1 field in an axial slice of the brain and then optimizes the placement of sinc-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21585

    authors: Zelinski AC,Wald LL,Setsompop K,Alagappan V,Gagoski BA,Goyal VK,Adalsteinsson E

    更新日期:2008-06-01 00:00:00

  • Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

    abstract:PURPOSE:To develop a strategy for training a physics-guided MRI reconstruction neural network without a database of fully sampled data sets. METHODS:Self-supervised learning via data undersampling (SSDU) for physics-guided deep learning reconstruction partitions available measurements into two disjoint sets, one of wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28378

    authors: Yaman B,Hosseini SAH,Moeller S,Ellermann J,Uğurbil K,Akçakaya M

    更新日期:2020-12-01 00:00:00

  • The fast spiral-SelMQC technique for in vivo MR spectroscopic imaging of polyunsaturated fatty acids in human breast tissue.

    abstract::The selective multiple-quantum coherence transfer method has been applied to image polyunsaturated fatty acids (PUFA) distributions in human breast tissues in vivo for cancer detection, with complete suppression of the unwanted lipid and water signals in a single scan. The Cartesian k-space mapping of PUFA in vivo usi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22901

    authors: Zhu H,Rubin D,He Q

    更新日期:2012-01-01 00:00:00

  • A novel bioreactor for combined magnetic resonance spectroscopy and optical imaging of metabolism in 3D cell cultures.

    abstract:PURPOSE:Fluorescence lifetime imaging microscopy (FLIM) of endogenous fluorescent metabolites permits the measurement of cellular metabolism in cell, tissue and animal models. In parallel, magnetic resonance spectroscopy (MRS) of dynamic nuclear (hyper)polarized (DNP) 13 C-pyruvate enables measurement of metabolism at ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27644

    authors: Cox BL,Erickson-Bhatt S,Szulczewski JM,Squirrell JM,Ludwig KD,Macdonald EB,Swader R,Ponik SM,Eliceiri KW,Fain SB

    更新日期:2019-05-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Apparent changes of appearance of inversion-recovery images.

    abstract::This note considers the anomolous contrast in inversion recovery images produced by NMR scanners if a map of [My] is reconstructed, rather than a map of My'. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020110

    authors: Young IR,Bailes DR,Bydder GM

    更新日期:1985-02-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling.

    abstract::Perfusion imaging by arterial spin labeling (ASL) can be highly sensitive to the transit time from the labeling site to the tissue. We report the results of a study designed to separate the transit time and perfusion contributions to activation in ASL images accompanying motor and visual stimulation. Fractional transi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<739::aid-mrm17

    authors: Gonzalez-At JB,Alsop DC,Detre JA

    更新日期:2000-05-01 00:00:00

  • Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging.

    abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24235

    authors: Lundell H,Barthelemy D,Biering-Sørensen F,Cohen-Adad J,Nielsen JB,Dyrby TB

    更新日期:2013-01-01 00:00:00

  • Strain-dependent T1 relaxation profiles in articular cartilage by MRI at microscopic resolutions.

    abstract::To investigate the dependency of T(1) relaxation on mechanical strain in articular cartilage, quantitative magnetic resonance T(1) imaging experiments were carried out on cartilage before/after the tissue was immersed in gadolinium contrast agent and when the tissue was being compressed (up to ∼ 48% strains). The spat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22933

    authors: Xia Y,Wang N,Lee J,Badar F

    更新日期:2011-06-01 00:00:00

  • Proton high-resolution magic angle spinning NMR analysis of fresh and previously frozen tissue of human prostate.

    abstract::The previously observed improvement in spectral resolution of tissue proton NMR with high-resolution magic angle spinning (HRMAS) was speculated to be due largely to freeze-thawing artifacts resulting from tissue storage. In this study, 12 human prostate samples were analyzed on a 14.1T spectrometer at 3 degrees C, wi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10645

    authors: Wu CL,Taylor JL,He W,Zepeda AG,Halpern EF,Bielecki A,Gonzalez RG,Cheng LL

    更新日期:2003-12-01 00:00:00

  • Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations.

    abstract:PURPOSE:Evaluate the usefulness of single-shot and of interleaved spatiotemporally encoded (SPEN) methods to perform diffusion tensor imaging (DTI) under various preclinical and clinical settings. METHODS:A formalism for analyzing SPEN DTI data is presented, tailored to account for the spatially dependent b-matrix wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26197

    authors: Solomon E,Liberman G,Nissan N,Frydman L

    更新日期:2017-03-01 00:00:00

  • Reconstruction by calibration over tensors for multi-coil multi-acquisition balanced SSFP imaging.

    abstract:PURPOSE:To develop a rapid imaging framework for balanced steady-state free precession (bSSFP) that jointly reconstructs undersampled data (by a factor of R) across multiple coils (D) and multiple acquisitions (N). To devise a multi-acquisition coil compression technique for improved computational efficiency. METHODS:...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26902

    authors: Biyik E,Ilicak E,Çukur T

    更新日期:2018-05-01 00:00:00

  • Lung imaging under free-breathing conditions.

    abstract::Respiratory motion and pulsatile blood flow can generate artifacts in morphological and functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio, is limited when performing breath-hold and/or electrocardiogram-triggered imaging. To overcome these limitations, imaging during free r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21846

    authors: Oechsner M,Pracht ED,Staeb D,Arnold JF,Köstler H,Hahn D,Beer M,Jakob PM

    更新日期:2009-03-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized (3) He MRI.

    abstract:PURPOSE:A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pA O2 ) measurements using (3) He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pA O2 was compared with that of the standard pulmonary func...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24604

    authors: Hamedani H,Kadlecek SJ,Ishii M,Emami K,Kuzma NN,Xin Y,Rossman M,Rizi RR

    更新日期:2013-12-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00

  • 31P NMR studies of resting zone cartilage from growth plate.

    abstract::31P NMR of superfused resting cartilage demonstrated the presence of phosphocreatine in chondrocytes. Changes in pH and in the NTP level were followed during carbon source starvation. From 31P spectra of perchloric acid extracts, phosphoethanolamine, phosphocholine, and the corresponding glycerol diesters were identif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250215

    authors: Kvam BJ,Pollesello P,Vittur F,Paoletti S

    更新日期:1992-06-01 00:00:00

  • 4D radial coronary artery imaging within a single breath-hold: cine angiography with phase-sensitive fat suppression (CAPS).

    abstract::Coronary artery data acquisition with steady-state free precession (SSFP) is typically performed in a single frame in mid-diastole with a spectrally selective pulse to suppress epicardial fat signal. Data are acquired while the signal approaches steady state, which may lead to artifacts from the SSFP transient respons...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20627

    authors: Park J,Larson AC,Zhang Q,Simonetti O,Li D

    更新日期:2005-10-01 00:00:00

  • Fat-water separation based on Transition REgion Extraction (TREE).

    abstract:PURPOSE:To develop a method based on fat-water transition region extraction (TREE) for robust fat-water separation and quantification in challenging scenarios, including low signal-to-noise ratio (SNR), fast changing B0 field, and disjointed anatomies. THEORY AND METHODS:In TREE method, the phasor solutions of each pi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27710

    authors: Peng H,Zou C,Cheng C,Tie C,Qiao Y,Wan Q,Lv J,He Q,Liang D,Liu X,Liu W,Zheng H

    更新日期:2019-07-01 00:00:00

  • The effects of intravoxel contrast agent diffusion on the analysis of DCE-MRI data in realistic tissue domains.

    abstract:PURPOSE:Quantitative evaluation of dynamic contrast enhanced MRI (DCE-MRI) allows for estimating perfusion, vessel permeability, and tissue volume fractions by fitting signal intensity curves to pharmacokinetic models. These compart mental models assume rapid equilibration of contrast agent within each voxel. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26995

    authors: Woodall RT,Barnes SL,Hormuth DA 2nd,Sorace AG,Quarles CC,Yankeelov TE

    更新日期:2018-07-01 00:00:00