Abstract:
PURPOSE:We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS:We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but not on coil design, and we used it as the reference to compare the performance of various transmit arrays. We investigated the case of fixing coil size and increasing the number of coils while moving the array away from the sample, as well as the case of fixing coil number and scaling coil dimensions. We also investigated RF power requirements as a function of lift-off, and tracked local SAR distributions associated with global SAR optima. RESULTS:In all cases, the target excitation profile was achieved and global SAR (as well as associated maximum local SAR) decreased with lift-off, approaching UISAR, which was constant for all lift-offs. We observed a lift-off value that optimizes the balance between global SAR and power losses in coil conductors. We showed that, using parallel transmission, global SAR can decrease at ultra high fields for finite arrays with a sufficient number of transmit elements. CONCLUSION:For parallel transmission, the distance between coils and object can be optimized to reduce SAR and minimize RF power requirements associated with homogeneous excitation.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Deniz CM,Vaidya MV,Sodickson DK,Lattanzi Rdoi
10.1002/mrm.25646subject
Has Abstractpub_date
2016-01-01 00:00:00pages
423-32issue
1eissn
0740-3194issn
1522-2594journal_volume
75pub_type
杂志文章abstract::The relaxivities (R-values) of the gadolinium diethylene triamine pentaacetic acid (Gd(DTPA)2-) ions in a series of skim-milk solutions at 0-40% milk concentrations were measured using NMR spectroscopy. The R-value was found to be approximately linearly proportional to the concentration of the solid component in the m...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22169
更新日期:2010-01-01 00:00:00
abstract::Compressed sensing has been of great interest to speed up the acquisition of MR images. The k-t group sparse (k-t GS) method has recently been introduced for dynamic MR images to exploit not just the sparsity, as in compressed sensing, but also the spatial group structure in the sparse representation. k-t GS achieves ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24333
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS:We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluate...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24982
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:To exploit the improved comparability and hardware independency of quantitative MRI, databases of MR physical parameters in healthy tissue are required, to which tissue properties of patients can be compared. In this work, normative values for longitudinal and transverse relaxation times in the brain were estab...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27927
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:Classification of pediatric brain tumors from 1 H-magnetic resonance spectroscopy (MRS) can aid diagnosis and management of brain tumors. However, varied incidence of the different tumor types leads to imbalanced class sizes and introduces difficulties in classifying rare tumor groups. This study assessed diffe...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26318
更新日期:2017-06-01 00:00:00
abstract::The purpose of this study is (1) to determine the correlation between T(1rho) and T(2) and degenerative grade in intervertebral discs using in vivo 3.0-T MRI, and (2) to determine the association between T(1rho) and T(2) and clinical findings as quantified by the SF-36 Questionnaire and Oswestry Disability Index. Sixt...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22362
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24824
更新日期:2014-05-01 00:00:00
abstract::Brain water diffusion in response to transient global ischemia (12 min), reperfusion (60 min), and cardiac arrest was monitored by localized proton magnetic resonance spectroscopy. The trace of the apparent diffusion coefficient tensor (ADC(Av)) was determined at high temporal resolution (10 sec) to assess the putativ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199910)42:4<798::aid-mrm23
更新日期:1999-10-01 00:00:00
abstract:PURPOSE:Endothelial nitric oxide synthase (eNOS) plays a central role in regulating vascular tone, blood flow, and microvascular permeability. Endothelial dysfunction, including eNOS dysfunction, is an early biomarker of vascular disease. This study aimed to show that myocardial T1 mapping during nitric oxide synthase ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26870
更新日期:2018-04-01 00:00:00
abstract::Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21013
更新日期:2006-10-01 00:00:00
abstract::The pulse wave velocity (PWV) of aortic blood flow is considered a surrogate for aortic compliance. A new method using phase-contrast (PC)-MRI is presented whereby the spatial and temporal profiles of axial velocity along the descending aorta can be analyzed. Seventeen young healthy volunteers (the YH group), six olde...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21034
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:To develop a practical method for mapping macromolecule distribution in the brain using ultrashort-TE MRSI data. METHODS:An FID-based chemical shift imaging acquisition without metabolite-nulling pulses was used to acquire ultrashort-TE MRSI data that capture the macromolecule signals with high signal-to-noise...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26896
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction. METHODS:SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherw...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27662
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole-body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arb...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25531
更新日期:2015-12-01 00:00:00
abstract::There is increasing interest in quantitative T(1) mapping techniques for a variety of applications. Several methods for T(1) quantification have been described. The acquisition of two spoiled gradient-echo data sets with different flip angles allows for the calculation of T(1) maps with a high spatial resolution and a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21776
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24807
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:To investigate a computationally efficient method for optimizing the Cramér-Rao Lower Bound (CRLB) of quantitative sequences without using approximations or an analytical expression of the signal. METHODS:Automatic differentiation was applied to Bloch simulations and used to optimize several quantitative seque...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27832
更新日期:2019-10-01 00:00:00
abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370603
更新日期:1997-06-01 00:00:00
abstract::The prebolus technique allows one to quantify perfusion in the human heart with a low variability by means of MRI. In this study the prebolus technique was used to determine quantitative perfusion values in the human heart under adenosine stress and to measure the myocardial perfusion reserve (MPR). Twelve healthy vol...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21020
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS:3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27540
更新日期:2019-03-01 00:00:00
abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390224
更新日期:1998-02-01 00:00:00
abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25848
更新日期:2016-07-01 00:00:00
abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050313
更新日期:1987-09-01 00:00:00
abstract::Orientational anisotropy of T2 and T1 relaxation times, diffusion, and magnetization transfer has been investigated for six different tissues: tendon, cartilage, kidney, muscle, white matter, and optic nerve. Relaxation anisotropy was observed for tendon and cartilage, and diffusional anisotropy was measured in kidney...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320508
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:To assess the risk of radiofrequency (RF)-induced heating in patients with MR-conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant. METHODS:Four commercial pacemaker leads were placed beside a MR-conditional PM system, inside a human trunk simulator. The phantom...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25106
更新日期:2015-01-01 00:00:00
abstract::Chemical shift imaging benefits from signal-to-noise ratio (SNR) and chemical shift dispersion increases at stronger main field such as 7 Tesla, but the associated shorter radiofrequency (RF) wavelengths encountered require B1+ mitigation over both the spatial field of view (FOV) and a specified spectral bandwidth. Th...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21834
更新日期:2009-02-01 00:00:00
abstract::Accelerated magnetic resonance imaging techniques reduce signal acquisition time by undersampling k-space. A fundamental problem in accelerated magnetic resonance imaging is the recovery of quality images from undersampled k-space data. Current state-of-the-art recovery algorithms exploit the spatial and temporal stru...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24524
更新日期:2013-09-01 00:00:00
abstract::High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc fi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030108
更新日期:1986-02-01 00:00:00
abstract::A planar YBa2Cu3Ox (YBCO) coil has been used as a pick-up coil in a nuclear magnetic resonance imager. It was found that the quality factor (Q) of the YBCO coil was greater than its copper counterpart by approaching 50% even in a field of 0.15 T. The Q of the copper coil at 77 K and in a field of 0.15 T was 1200 while...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910200218
更新日期:1991-08-01 00:00:00
abstract::To date, most functional imaging centers have relied on ultrafast imaging approaches such as echo-planar imaging (EPI) techniques for acquiring functional brain activation data. These methods require specialized hardware and are not yet installed widely on clinical MR imagers, thus limiting the application of function...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380417
更新日期:1997-10-01 00:00:00