A multicontrast imaging method using steady-state free precession with alternating RF flip angles.

Abstract:

PURPOSE:To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed. METHODS:The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence has its own unique contrast, which combines both FID signal and echo signal under a steady-state condition. By using alternating RF flip angles and RF phase cycling, various image contrasts weighted by proton density, T1 , and T2 can be obtained. The proposed method offers multicontrast images with fat suppression by using the combination of 2 images obtained just after alternating RF pulses, respectively. RESULTS:As demonstrated by simulations, phantom and in vivo experiments, the proposed method provides multicontrast knee images including fat-suppressed contrast images. CONCLUSION:The proposed method can be a useful tool for clinical diagnosis, such as the cartilage segmentation and the fast screening of lesions.

journal_name

Magn Reson Med

authors

Kim J,Seo H,So S,Park H

doi

10.1002/mrm.27342

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

1341-1351

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

80

pub_type

杂志文章
  • System identification theory in pharmacokinetic modeling of dynamic contrast-enhanced MRI: influence of contrast injection.

    abstract::Optimization of experimental settings of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), like the contrast administration protocol, is of great importance for reliable quantification of the microcirculatory properties, such as the volume transfer-constant K(trans). Using system identification theory an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21575

    authors: Aerts HJ,van Riel NA,Backes WH

    更新日期:2008-05-01 00:00:00

  • Efficient visualization of vascular territories in the human brain by cycled arterial spin labeling MRI.

    abstract::Intracranial vascular territories are usually visualized with the use of angiographic techniques. However, because it is difficult to visualize the distal vascular bed with any angiographic technique, it is also difficult to infer the parenchymal borders of vascular territories. Arterial spin labeling (ASL) MRI provid...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20998

    authors: Günther M

    更新日期:2006-09-01 00:00:00

  • Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.

    abstract:PURPOSE:For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25507

    authors: Ahmad R,Xue H,Giri S,Ding Y,Craft J,Simonetti OP

    更新日期:2015-11-01 00:00:00

  • Simplified synthesis and relaxometry of magnetoferritin for magnetic resonance imaging.

    abstract::Magnetoferritin nanoparticles have been developed as high-relaxivity, functional contrast agents for MRI. Several previous techniques have relied on unloading native ferritin and re-incorporation of iron into the core, often resulting in a polydisperse sample. Here, a simplified technique is developed using commercial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22526

    authors: Jordan VC,Caplan MR,Bennett KM

    更新日期:2010-11-01 00:00:00

  • Relaxation effects of ferucarbotran-labeled mesenchymal stem cells at 1.5T and 3T: discrimination of viable from lysed cells.

    abstract::Human mesenchymal stem cells (hMSCs) were labeled with Ferucarbotran by simple incubation and cultured for up to 14 d. Iron content was determined by spectrometry and the intracellular localization of the contrast agent uptake was studied by electron and confocal microscopy. At various time points after labeling, rang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22011

    authors: Henning TD,Wendland MF,Golovko D,Sutton EJ,Sennino B,Malek F,Bauer JS,McDonald DM,Daldrup-Link H

    更新日期:2009-08-01 00:00:00

  • Boron-11 NMR of borocaptate: relaxation and in vivo detection in melanoma-bearing mice.

    abstract::Longitudinal and transverse relaxation rates for the 11B resonances in sodium borocaptate (BSH) at varying concentrations were measured in undiluted horse serum in a 4.7 Tesla field. The results could be fit by a model that assumes fast exchange of the BSH molecule between a free and a bound state, using values of 0.7...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390314

    authors: Bendel P,Frantz A,Zilberstein J,Kabalka GW,Salomon Y

    更新日期:1998-03-01 00:00:00

  • Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

    abstract::We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by opti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320416

    authors: Felblinger J,Lehmann C,Boesch C

    更新日期:1994-10-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • Echo-volume imaging.

    abstract::Two single-shot volume imaging techniques are described. The first, single-echo echo-volume imaging, is essentially the echo-volume imaging (EVI) sequence suggested by Mansfield (J. Phys. C. 10, L55 (1977)). The second is a multi-spin-echo approach in which one plane of k-space is collected during each spin echo. In b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320518

    authors: Song AW,Wong EC,Hyde JS

    更新日期:1994-11-01 00:00:00

  • A molecular MRI probe to detect treatment of cardiac apoptosis in vivo.

    abstract::Cell death by apoptosis is critical in myocardial diseases, and noninvasive detection of early, reversible apoptosis might be useful clinically. Exogenous Annexin-V (ANX) protein binds membrane phosphatidylserine, which is externalized in early apoptosis. A molecular MRI probe was constructed with superparamagnetic ir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22876

    authors: Dash R,Chung J,Chan T,Yamada M,Barral J,Nishimura D,Yang PC,Simpson PC

    更新日期:2011-10-01 00:00:00

  • In vivo evaluation of intracellular pH and high-energy phosphate metabolites during regional myocardial ischemia in cats using 31P nuclear magnetic resonance.

    abstract::Phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) was used to assess the temporal changes of high-energy phosphate metabolites in the region of acute myocardial ischemia of open-chest cats. Eight anesthetized cats were studied following ligation of the left anterior descending coronary artery. Creatine p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030209

    authors: Stein PD,Goldstein S,Sabbah HN,Liu ZQ,Helpern JA,Ewing JR,Lakier JB,Chopp M,LaPenna WF,Welch KM

    更新日期:1986-04-01 00:00:00

  • Water-suppressed one-dimensional 1H NMR spectroscopic imaging of myocardial metabolites in vivo.

    abstract::Excitation by conventional B1 pulses in surface coil chemical-shift imaging experiments yields resonance intensities that vary greatly with position. B1-compensated semi-selective pulses overcome much of this problem. These pulses are employed for excitation and refocusing in 1H NMR spectroscopic localization in the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250118

    authors: Balschi JA,Hetherington HP,Pohost GM

    更新日期:1992-05-01 00:00:00

  • Altered white matter diffusion anisotropy in normal and preterm infants at term-equivalent age.

    abstract::To investigate white matter (WM) development, voxelwise analyses of diffusion tensor MRI (DTMRI) data, acquired from 12 very preterm and 11 preterm infants with gestational ages (GA) ranging from 25 to 29 and 29 to 32 weeks, respectively, and 10 newborn normal term infants were performed. T(2) relaxation measures were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21689

    authors: Rose SE,Hatzigeorgiou X,Strudwick MW,Durbridge G,Davies PS,Colditz PB

    更新日期:2008-10-01 00:00:00

  • In vivo GABA editing using a novel doubly selective multiple quantum filter.

    abstract::A novel multiple quantum filtering method is proposed that uses a doubly selective pulse termed Delays Alternating with Nutations for Tailored Excitation (DANTE) for multiple quantum preparation. This method selectively prepares GABA-3 and GABA-4 into a multiple quantum state and suppresses all other resonances at 3.0...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10104

    authors: Shen J,Rothman DL,Brown P

    更新日期:2002-03-01 00:00:00

  • Comparison between simulated decoupling regimes for specific absorption rate prediction in parallel transmit MRI.

    abstract:PURPOSE:The use of electromagnetic (EM) modeling is critical for specific absorption rate (SAR) characterization in parallel transmission MRI. Radiofrequency arrays that include decoupling networks can be difficult to characterize accurately in simulation. A practical method of simplifying modeling is to exclude the de...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25504

    authors: Beqiri A,Hand JW,Hajnal JV,Malik SJ

    更新日期:2015-11-01 00:00:00

  • Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

    abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25322

    authors: Li X,van Zijl PC

    更新日期:2014-09-01 00:00:00

  • Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

    abstract::This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21157

    authors: Catalano O,Corsi C,Antonaci S,Moro G,Mussida M,Frascaroli M,Baldi M,Caiani E,Lamberti C,Cobelli F

    更新日期:2007-03-01 00:00:00

  • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

    abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21921

    authors: Cukur T,Lee JH,Bangerter NK,Hargreaves BA,Nishimura DG

    更新日期:2009-06-01 00:00:00

  • Fast oxygen-enhanced multislice imaging of the lung using parallel acquisition techniques.

    abstract::The purpose of this study was to evaluate an optimized multislice acquisition technique for oxygen-enhanced MRI of the lung using slice-selective inversion and refocusing pulses in combination with parallel imaging. An inversion recovery HASTE sequence was implemented with respiratory triggering to perform imaging in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20495

    authors: Dietrich O,Losert C,Attenberger U,Fasol U,Peller M,Nikolaou K,Reiser MF,Schoenberg SO

    更新日期:2005-06-01 00:00:00

  • Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

    abstract:PURPOSE:Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging meth...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25134

    authors: Celicanin Z,Bieri O,Preiswerk F,Cattin P,Scheffler K,Santini F

    更新日期:2015-02-01 00:00:00

  • Inability to directly detect magnetic field changes associated with neuronal activity.

    abstract::The ability to directly detect neuronal magnetic fields by MRI would help investigators achieve the "holy grail" of neuroimaging, namely both high spatial and temporal resolution. Both positive and negative findings have been reported in the literature, with no clear consensus as to the feasibility of direct detection...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21129

    authors: Parkes LM,de Lange FP,Fries P,Toni I,Norris DG

    更新日期:2007-02-01 00:00:00

  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • Dynamic 31 P spectroscopic imaging of skeletal muscles combining flyback echo-planar spectroscopic imaging and compressed sensing.

    abstract:PURPOSE:Dynamic phosphorus MR spectroscopic imaging (31 P-MRSI) experiments require temporal resolution on the order of seconds to concurrently assess different muscle groups. A highly accelerated pulse sequence combining flyback echo-planar spectroscopic imaging (EPSI) and compressed sensing was developed and tested i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27682

    authors: Santos-Díaz A,Harasym D,Noseworthy MD

    更新日期:2019-06-01 00:00:00

  • "PINOT": time-resolved parallel magnetic resonance imaging with a reduced dynamic field of view.

    abstract::This article introduces a novel method named "Parallel Imaging and Noquist in Tandem" (PINOT) for accelerated image acquisition of cine cardiac magnetic resonance imaging. This method combines two prior information formalisms, the SPACE-RIP implementation of parallel imaging and the Noquist method for reduced-data ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22696

    authors: Hamilton LH,Fabregat JA,Moratal D,Ramamurthy S,Lerakis S,Parks WJ,Sallee D 3rd,Brummer ME

    更新日期:2011-04-01 00:00:00

  • Quantitative transport mapping (QTM) of the kidney with an approximate microvascular network.

    abstract:PURPOSE:Proof-of-concept study of mapping renal blood flow vector field according to the inverse solution to a mass transport model of time resolved tracer-labeled MRI data. THEORY AND METHODS:To determine tissue perfusion according to the underlying physics of spatiotemporal tracer concentration variation, the mass t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28584

    authors: Zhou L,Zhang Q,Spincemaille P,Nguyen TD,Morgan J,Dai W,Li Y,Gupta A,Prince MR,Wang Y

    更新日期:2021-04-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Noise correlation.

    abstract::Calculations and experiments that provide support for our previously stated theorem are presented: If two coils simultaneously receiving magnetic resonance signals from the same anatomic region exhibit zero mutual inductance, there can be no correlation of the noise. It is shown that correlation does not exist even in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200105

    authors: Jesmanowicz A,Hyde JS,Froncisz W,Kneeland JB

    更新日期:1991-07-01 00:00:00

  • Synchronous MRI of muscle motion induced by electrical stimulation.

    abstract:PURPOSE:Assessing the functionality of muscle fibers is essential to monitor both pathological and physiological processes. Here, we present a new method for accurate, quantitative measurement of muscle contraction with magnetic resonance imaging (MRI) using an electrical muscle stimulator (EMS), hence allowing the dir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26154

    authors: Deligianni X,Pansini M,Garcia M,Hirschmann A,Schmidt-Trucksäss A,Bieri O,Santini F

    更新日期:2017-02-01 00:00:00

  • MRI reconstruction using deep Bayesian estimation.

    abstract:PURPOSE:To develop a deep learning-based Bayesian estimation for MRI reconstruction. METHODS:We modeled the MRI reconstruction problem with Bayes's theorem, following the recently proposed PixelCNN++ method. The image reconstruction from incomplete k-space measurement was obtained by maximizing the posterior possibili...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28274

    authors: Luo G,Zhao N,Jiang W,Hui ES,Cao P

    更新日期:2020-10-01 00:00:00