Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

Abstract:

:This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a conventional disk-area technique. In a sample of 23 patients, with wide variability of RV end-diastolic volume (EDV: 47-131 ml), end-systolic volume (ESV: 20-76 ml), and ejection fraction (EF: 29-73%), using the standard method (Argus, Siemens) as the reference, the VoSD method showed good agreement for EDV, ESV, and EF estimations (correlation coefficient: 0.91, 0.94, and 0.94; Bland-Altman biases: 1 ml, 1 ml, and 0%; limits of agreement: +/-16 ml, +/-11 ml, and +/-11%, respectively). An analysis of the reproducibility of the two methods showed lower intraobserver variability for the VoSD method than for the conventional method, as evidenced by the coefficient of variability (CoV) values (2-6% vs. 8-15%; P < 0.05). In addition, the VoSD method showed improved interobserver reproducibility (7-10% vs. 8-15%), but the difference was statistically significant only for EF estimation variability (8 vs. 15%, P < 0.05). In conclusion, the newly developed VoSD technique allows accurate measurements of RV volumes and function, and appears to be more reproducible than the conventional methodology.

journal_name

Magn Reson Med

authors

Catalano O,Corsi C,Antonaci S,Moro G,Mussida M,Frascaroli M,Baldi M,Caiani E,Lamberti C,Cobelli F

doi

10.1002/mrm.21157

subject

Has Abstract

pub_date

2007-03-01 00:00:00

pages

600-5

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

57

pub_type

杂志文章
  • Fast Fourier imaging.

    abstract::A new NMR imaging technique, aiming at a reduction of the data acquisition time, is described in detail. The method is applicable in all multidimensional imaging situations where at least one spatial coordinate is resolved. Discussed at some length are the point-spread function, the required bandwidth of the NMR spect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020304

    authors: van Uijen CM,den Boef JH,Verschuren FJ

    更新日期:1985-06-01 00:00:00

  • Boron-11 NMR of borocaptate: relaxation and in vivo detection in melanoma-bearing mice.

    abstract::Longitudinal and transverse relaxation rates for the 11B resonances in sodium borocaptate (BSH) at varying concentrations were measured in undiluted horse serum in a 4.7 Tesla field. The results could be fit by a model that assumes fast exchange of the BSH molecule between a free and a bound state, using values of 0.7...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390314

    authors: Bendel P,Frantz A,Zilberstein J,Kabalka GW,Salomon Y

    更新日期:1998-03-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone.

    abstract::Cortical bone in the mature skeleton has a short T(2)* and produces no detectable signal with conventional MR sequences. A two-dimensional ultrashort echo time (UTE) sequence employing half radio frequency (RF) pulse excitations and radial ramp sampling reduces the effective TE to 8 micros and is capable of detecting ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21397

    authors: Du J,Hamilton G,Takahashi A,Bydder M,Chung CB

    更新日期:2007-11-01 00:00:00

  • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils.

    abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4

    authors: Zaharchuk G,Ledden PJ,Kwong KK,Reese TG,Rosen BR,Wald LL

    更新日期:1999-06-01 00:00:00

  • Fourier decomposition pulmonary MRI using a variable flip angle balanced steady-state free precession technique.

    abstract:PURPOSE:Fourier decomposition (FD) is a noninvasive method for assessing ventilation and perfusion-related information in the lungs. However, the technique has a low signal-to-noise ratio (SNR) in the lung parenchyma. We present an approach to increase the SNR in both morphological and functional images. METHODS:The d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25293

    authors: Corteville DM,Kjïrstad Å,Henzler T,Zöllner FG,Schad LR

    更新日期:2015-05-01 00:00:00

  • Multislice and multicoil phase-sensitive inversion-recovery imaging.

    abstract::Phase-sensitive inversion-recovery (PSIR) imaging may provide enhanced T(1) contrast. However, clinical implementation of PSIR imaging is hindered because image reconstruction with this method often lacks robustness and requires manual intervention, particularly for data acquired in multiple slices and with phased-arr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20414

    authors: Ma J

    更新日期:2005-04-01 00:00:00

  • Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

    abstract::An eight-channel receive-only brain coil and table-top detunable volume transmit coil were developed and tested at 7 T for human imaging. Optimization of this device required attention to sources of interaction between the array elements, between the transmit and receive coils and minimization of common mode currents ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20547

    authors: Wiggins GC,Potthast A,Triantafyllou C,Wiggins CJ,Wald LL

    更新日期:2005-07-01 00:00:00

  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Respiration based steering for high intensity focused ultrasound liver ablation.

    abstract:PURPOSE:Respiratory motion makes hepatic ablation using high intensity focused ultrasound (HIFO) challenging. Previous HIFU liver treatment had required apnea induced during general anesthesia. We describe and test a system that allows treatment of the liver in the presence of breathing motion. METHODS:Mapping a signa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24695

    authors: Holbrook AB,Ghanouni P,Santos JM,Dumoulin C,Medan Y,Pauly KB

    更新日期:2014-02-01 00:00:00

  • Carotid-CNS MR flow imaging.

    abstract::The authors present their 1-year experience with the use of 3DFT, time-of-flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin-echo imaging with only a minimal incre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140215

    authors: Masaryk TJ,Laub GA,Modic MT,Ross JS,Haacke EM

    更新日期:1990-05-01 00:00:00

  • Susceptibility contrast imaging of cerebral blood volume: human experience.

    abstract::Magnetic resonance (MR) can offer a unique window on the structure/function relationships in the brain, by utilizing the established link between tissue function, metabolism, and hemodynamics. This report focuses on recent applications of MR-based cerebral blood volume (CBV) imaging in humans. Our methodology uses hig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910220227

    authors: Rosen BR,Belliveau JW,Aronen HJ,Kennedy D,Buchbinder BR,Fischman A,Gruber M,Glas J,Weisskoff RM,Cohen MS

    更新日期:1991-12-01 00:00:00

  • Motion correction in fMRI via registration of individual slices into an anatomical volume.

    abstract::An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI ses...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16

    authors: Kim B,Boes JL,Bland PH,Chenevert TL,Meyer CR

    更新日期:1999-05-01 00:00:00

  • Transient decrease in tumor oxygenation after intravenous administration of pyruvate.

    abstract::MRI using hyperpolarized (13) C-labeled pyruvate is a promising tool to biochemically profile tumors and monitor their response to therapy. This technique requires injection of pyruvate into tumor-bearing animals. Pyruvate is an endogenous entity but the influence of exogenously injected bolus doses of pyruvate on tum...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23065

    authors: Saito K,Matsumoto S,Devasahayam N,Subramanian S,Munasinghe JP,Morris HD,Lizak MJ,Ardenkjaer-Larsen JH,Mitchell JB,Krishna MC

    更新日期:2012-03-01 00:00:00

  • Water and fat MR imaging with chemical shift selective 3D steady state methods.

    abstract::A new 3D acquisition regimen that enables the collection of conventional, water-suppressed, and fat-suppressed images with no increase in scan times compared with currently implemented 3D sequences is presented. The method is based on conventional 3D steady state with interleaved selective excitation of the fat resona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310403

    authors: Sun L,Aletras AH,Schmalbrock P,Skinner TE,Chakeres D,Irsik R,Robitaille PM

    更新日期:1994-04-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

    abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20848

    authors: Sabati M,Lauzon ML,Mahallati H,Frayne R

    更新日期:2006-05-01 00:00:00

  • Driving mutually coupled gradient array coils in magnetic resonance imaging.

    abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27768

    authors: Ertan K,Taraghinia S,Atalar E

    更新日期:2019-09-01 00:00:00

  • Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

    abstract::To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24114

    authors: Tam LK,Stockmann JP,Galiana G,Constable RT

    更新日期:2012-10-01 00:00:00

  • Aortic 4D flow: quantification of signal-to-noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T.

    abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25317

    authors: Hess AT,Bissell MM,Ntusi NA,Lewis AJ,Tunnicliffe EM,Greiser A,Stalder AF,Francis JM,Myerson SG,Neubauer S,Robson MD

    更新日期:2015-05-01 00:00:00

  • Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model.

    abstract:PURPOSE:To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-nois...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28473

    authors: Shepelytskyi Y,Li T,Grynko V,Newman C,Hane FT,Albert MS

    更新日期:2021-02-01 00:00:00

  • Detection of subnanotesla oscillatory magnetic fields using MRI.

    abstract:PURPOSE:Direct mapping of neuronal currents using MRI would have fundamental impacts on brain functional imaging. Previous reports indicated that the stimulus-induced rotary saturation (SIRS) mechanism had the best potential of direct detection of neural oscillations; however, it lacked the high-sensitivity level neede...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25553

    authors: Jiang X,Sheng J,Li H,Chai Y,Zhou X,Wu B,Guo X,Gao JH

    更新日期:2016-02-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • A modified sub-second fast-STEAM sequence incorporating bipolar gradients for in vivo diffusion imaging.

    abstract::A modified high-speed stimulated-echo acquisition mode (STEAM) diffusion sequence (90 degrees-TE/2-90 degrees-TM-[alpha-TE/2-STE]n) incorporating bipolar diffusion gradients that are less sensitive to macroscopic motion-induced artifacts is presented. Diffusion encoding was performed only during the first echo interva...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350620

    authors: Yongbi MN,Ding S,Dunn JF

    更新日期:1996-06-01 00:00:00

  • Robust estimation of spatially variable noise fields.

    abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22013

    authors: Landman BA,Bazin PL,Smith SA,Prince JL

    更新日期:2009-08-01 00:00:00

  • Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM).

    abstract::The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360213

    authors: Eckstein F,Gavazzeni A,Sittek H,Haubner M,Lösch A,Milz S,Englmeier KH,Schulte E,Putz R,Reiser M

    更新日期:1996-08-01 00:00:00

  • Quantitative susceptibility mapping (QSM) of white matter multiple sclerosis lesions: Interpreting positive susceptibility and the presence of iron.

    abstract:PURPOSE:Within multiple sclerosis (MS) lesions iron is present in chronically activated microglia. Thus, iron detection with MRI might provide a biomarker for chronic inflammation within lesions. Here, we examine contributions of iron and myelin to magnetic susceptibility of lesions on quantitative susceptibility mappi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25420

    authors: Wisnieff C,Ramanan S,Olesik J,Gauthier S,Wang Y,Pitt D

    更新日期:2015-08-01 00:00:00

  • Low-power NMR volume selection by slicing z magnetization.

    abstract::A novel method for reducing the rf power requirements of selective pulses employed for z magnetization slice inversion in localized NMR spectroscopy is presented. Following slice preparation by the use of frequency-incremented sinc pulses, the slice gradient is reduced, which narrows the frequency width of the slice. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050610

    authors: Brereton IM,Brooks WM,Marshman MF,Field J,Doddrell DM

    更新日期:1987-12-01 00:00:00

  • Nonbalanced SSFP-based quantitative magnetization transfer imaging.

    abstract::The previously reported concept for quantitative magnetization transfer (MT) imaging using balanced steady-state free precession (SSFP) is applied to nonbalanced SSFP sequences. This offers the possibility to derive quantitative MT parameters of targets with high-susceptibility variations such as the musculoskeletal s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22331

    authors: Gloor M,Scheffler K,Bieri O

    更新日期:2010-07-01 00:00:00