pH mapping in living tissues: an application of in vivo 31P NMR chemical shift imaging.

Abstract:

:Chemical shifts were extracted from in vivo 3-dimensional 31P NMR CSI data and pH images were constructed. The images could spatially resolve tissue pH ranging from 5.8 to 7.2 (with uncertainty of 0.11-0.17 pH unit) in an ischemia-reperfusion model of diabetic rat calf muscles.

journal_name

Magn Reson Med

authors

Morikawa S,Inubushi T,Kito K,Kido C

doi

10.1002/mrm.1910290214

subject

Has Abstract

pub_date

1993-02-01 00:00:00

pages

249-51

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

29

pub_type

杂志文章
  • Flow-suppressed hyperpolarized 13 C chemical shift imaging using velocity-optimized bipolar gradient in mouse liver tumors at 9.4 T.

    abstract:PURPOSE:To optimize and investigate the influence of bipolar gradients for flow suppression in metabolic quantification of hyperpolarized 13 C chemical shift imaging (CSI) of mouse liver at 9.4 T. METHODS:The trade-off between the amount of flow suppression using bipolar gradients and T2* effect from static spins was ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26578

    authors: Lee H,Lee J,Joe E,Yang S,Song JE,Choi YS,Wang E,Joo CG,Song HT,Kim DH

    更新日期:2017-11-01 00:00:00

  • Interventional MR elastography for MRI-guided percutaneous procedures.

    abstract:PURPOSE:MRI-guided thermal ablations require reliable monitoring methods to ensure complete destruction of the diseased tissue while avoiding damage to the surrounding healthy tissue. Based on the fact that thermal ablations result in substantial changes in biomechanical properties, interventional MR elastography (MRE)...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25694

    authors: Corbin N,Vappou J,Breton E,Boehler Q,Barbé L,Renaud P,de Mathelin M

    更新日期:2016-03-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Tuning and amplification strategies for intravascular imaging coils.

    abstract::The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal-to-noise benefits...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24134

    authors: Yak N,Anderson KJ,Wright GA

    更新日期:2012-11-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • A 1H-NMR method for determining temperature in cell culture perfusion systems.

    abstract::This report describes a noninvasive 1H-NMR method for measuring absolute temperatures (+/- 0.2 degrees C) in biological samples and, in particular, in cell culture perfusion systems, utilizing the linear temperature dependence of the water chemical shift relative to the temperature-independent shift of one of the comp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290120

    authors: Lutz NW,Kuesel AC,Hull WE

    更新日期:1993-01-01 00:00:00

  • Imaging of the active B1 field in vivo.

    abstract::The authors describe a method for accurate in vivo multislice imaging of the active component of the B1 field which is based on a previously proposed method, which uses the signal intensity ratio of two images measured with different excitation angles, and a repetition time TR 5 > or = 5 T1. The new method essentially...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350217

    authors: Stollberger R,Wach P

    更新日期:1996-02-01 00:00:00

  • Noninvasive in vivo oximetric imaging by radiofrequency FT EPR.

    abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10133

    authors: Subramanian S,Yamada K,Irie A,Murugesan R,Cook JA,Devasahayam N,Van Dam GM,Mitchell JB,Krishna MC

    更新日期:2002-05-01 00:00:00

  • Proton NMR study of the state of water in fibrin gels, plasma, and blood clots.

    abstract::A proton NMR relaxation and pulsed field gradient self-diffusion study of water in fibrin gels, plasma, and blood clots has been performed with special emphasis on the effect of the sol-gel and shrinkage transitions. Deuteron NMR in fibrin gels was also studied to supplement the proton data. It is shown that a measure...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140111

    authors: Blinc A,Lahajnar G,Blinc R,Zidansek A,Sepe A

    更新日期:1990-04-01 00:00:00

  • Magnetic resonance imaging of experimental mumps meningoencephalitis in suckling hamsters.

    abstract::Mumps virus-infected and normal newborn hamster brains were imaged with magnetic resonance (MR) within 24 h after birth and serially scanned. Hydrocephalus developed explosively on Day 6 postinfection and progressed until death occurred soon after Day 10. This study demonstrates the utility of MR in the investigation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040611

    authors: Narayana PA,Wolinsky JS,Jensen DJ

    更新日期:1987-06-01 00:00:00

  • Automatic vessel removal in gliomas from dynamic susceptibility contrast imaging.

    abstract::The presence of macroscopic vessels within the tumor region is a potential confounding factor in MR-based dynamic susceptibility contrast (DSC)-enhanced glioma grading. In order to distinguish between such vessels and the elevated cerebral blood volume (CBV) of brain tumors, we propose a vessel segmentation technique ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21944

    authors: Emblem KE,Due-Tonnessen P,Hald JK,Bjornerud A

    更新日期:2009-05-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • Validation of a new T2* algorithm and its uncertainty value for cardiac and liver iron load determination from MRI magnitude images.

    abstract:PURPOSE:To validate an automatic algorithm for offline T2* measurements, providing robust, vendor-independent T2*, and uncertainty estimates for iron load quantification in the heart and liver using clinically available imaging sequences. METHODS:A T2* region of interest (ROI)-based algorithm was developed for robustn...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25767

    authors: Bidhult S,Xanthis CG,Liljekvist LL,Greil G,Nagel E,Aletras AH,Heiberg E,Hedström E

    更新日期:2016-04-01 00:00:00

  • Design and evaluation of quantitative MRI phantoms to mimic the simultaneous presence of fat, iron, and fibrosis in the liver.

    abstract:PURPOSE:To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton-density fat fraction (PDFF), R 2 ∗ ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28452

    authors: Zhao R,Hamilton G,Brittain JH,Reeder SB,Hernando D

    更新日期:2021-02-01 00:00:00

  • Voxelwise analysis of simultaneously acquired and spatially correlated 18 F-fluorodeoxyglucose (FDG)-PET and intravoxel incoherent motion metrics in breast cancer.

    abstract:PURPOSE:Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26505

    authors: Ostenson J,Pujara AC,Mikheev A,Moy L,Kim SG,Melsaether AN,Jhaveri K,Adams S,Faul D,Glielmi C,Geppert C,Feiweier T,Jackson K,Cho GY,Boada FE,Sigmund EE

    更新日期:2017-09-01 00:00:00

  • Spin-echo MRI using pi/2 and pi hyperbolic secant pulses.

    abstract::Frequency-modulated (FM) pulses have practical advantages for spin-echo experiments, such as the ability to produce a broadband pi rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21822

    authors: Park JY,Garwood M

    更新日期:2009-01-01 00:00:00

  • Longitudinal assessment of spinal cord injuries in nonhuman primates with quantitative magnetization transfer.

    abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25725

    authors: Wang F,Li K,Mishra A,Gochberg D,Min Chen L,Gore JC

    更新日期:2016-04-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • A new steady-state imaging sequence for simultaneous acquisition of two MR images with clearly different contrasts.

    abstract::We present a new steady-state imaging sequence, which simultaneously allows in a single acquisition the formation of two MR images with clearly different contrasts. The contrast of the first image is FISP-like, whereas the second image is strongly T2-weighted. In principle the T2 values in the image can be calculated ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070105

    authors: Bruder H,Fischer H,Graumann R,Deimling M

    更新日期:1988-05-01 00:00:00

  • Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI.

    abstract:PURPOSE:Respiratory organ motion is still the major challenge of various image-guided treatments in the abdomen. Dynamic organ motion tracking, necessary for the treatment control, can be performed with volumetric time-resolved MRI that sequentially acquires one image and one navigator slice. Here, a novel imaging meth...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25134

    authors: Celicanin Z,Bieri O,Preiswerk F,Cattin P,Scheffler K,Santini F

    更新日期:2015-02-01 00:00:00

  • Spatially resolved assessment of serotonin-induced bronchoconstrictive responses in the rat lung using 3He ventilation MRI under spontaneous breathing conditions.

    abstract::The effect on lung ventilation of bronchoconstriction induced by serotonin (intravenous injection of 50 microg/kg of serotonin) was imaged using a hyperpolarized (3)He MR ventilation protocol in spontaneously breathing rats. Lung function maps assessing airflow obstruction, a key feature in clinical pneumology, were d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22391

    authors: Mosbah K,Stupar V,Berthezène Y,Beckmann N,Crémillieux Y

    更新日期:2010-06-01 00:00:00

  • A pitfall associated with lactate detection using stimulated-echo proton spectroscopy.

    abstract::At TE values of 136 ms, it has recently been shown that the lactate methyl signal, when obtained with a stimulated-echo (STE) sequence, is modulated at the zero-quantum (ZQ) frequency when TM is varied. Here we describe an additional modulation of the ZQ lactate signal, due to spin-spin coupling, that results in a 10-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170223

    authors: Sotak CH,Alger JR

    更新日期:1991-02-01 00:00:00

  • Iterative reweighted linear least squares for accurate, fast, and robust estimation of diffusion magnetic resonance parameters.

    abstract:PURPOSE:Diffusion-weighted magnetic resonance imaging suffers from physiological noise, such as artifacts caused by motion or system instabilities. Therefore, there is a need for robust diffusion parameter estimation techniques. In the past, several techniques have been proposed, including RESTORE and iRESTORE (Chang e...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25351

    authors: Collier Q,Veraart J,Jeurissen B,den Dekker AJ,Sijbers J

    更新日期:2015-06-01 00:00:00

  • Detection of neural activity in functional MRI using canonical correlation analysis.

    abstract::A novel method for detecting neural activity in functional magnetic resonance imaging (fMRI) data is introduced. It is based on canonical correlation analysis (CCA), which is a multivariate extension of the univariate correlation analysis widely used in fMRI. To detect homogeneous regions of activity, the method combi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200102)45:2<323::aid-mrm1041>3.0

    authors: Friman O,Cedefamn J,Lundberg P,Borga M,Knutsson H

    更新日期:2001-02-01 00:00:00

  • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.

    abstract::A new approach to autocalibrating, coil-by-coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self-consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The appr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22428

    authors: Lustig M,Pauly JM

    更新日期:2010-08-01 00:00:00

  • Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme.

    abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24902

    authors: Iwadate Y,Brau AC,Vasanawala SS,Kabasawa H

    更新日期:2014-07-01 00:00:00

  • Novel insights into in-vivo diffusion tensor cardiovascular magnetic resonance using computational modeling and a histology-based virtual microstructure.

    abstract:PURPOSE:To develop histology-informed simulations of diffusion tensor cardiovascular magnetic resonance (DT-CMR) for typical in-vivo pulse sequences and determine their sensitivity to changes in extra-cellular space (ECS) and other microstructural parameters. METHODS:We synthesised the DT-CMR signal from Monte Carlo r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27561

    authors: Rose JN,Nielles-Vallespin S,Ferreira PF,Firmin DN,Scott AD,Doorly DJ

    更新日期:2019-04-01 00:00:00

  • Hyperpolarized 13C MRI of the pulmonary vasculature and parenchyma.

    abstract::The study of lung perfusion in normal and diseased subjects is of great interest to physiologists and physicians. In this work we demonstrate the application of a liquid-phase hyperpolarized (HP) carbon-13 ((13)C) tracer to magnetic resonance imaging (MRI) of the pulmonary vasculature and pulmonary perfusion in a porc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21168

    authors: Ishii M,Emami K,Kadlecek S,Petersson JS,Golman K,Vahdat V,Yu J,Cadman RV,MacDuffie-Woodburn J,Stephen M,Lipson DA,Rizi RR

    更新日期:2007-03-01 00:00:00

  • Quantitative transport mapping (QTM) of the kidney with an approximate microvascular network.

    abstract:PURPOSE:Proof-of-concept study of mapping renal blood flow vector field according to the inverse solution to a mass transport model of time resolved tracer-labeled MRI data. THEORY AND METHODS:To determine tissue perfusion according to the underlying physics of spatiotemporal tracer concentration variation, the mass t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28584

    authors: Zhou L,Zhang Q,Spincemaille P,Nguyen TD,Morgan J,Dai W,Li Y,Gupta A,Prince MR,Wang Y

    更新日期:2021-04-01 00:00:00

  • Single-shot localized echo-planar imaging (STEAM-EPI) at 4.7 tesla.

    abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140225

    authors: Turner R,von Kienlin M,Moonen CT,van Zijl PC

    更新日期:1990-05-01 00:00:00