Inductively coupled Helmholtz coil on a dedicated imaging platform for the in vivo 1H-MRS measurement of intramyocellular lipids in the hind leg of rats.

Abstract:

:Skeletal muscle triglycerides are markers for insulin resistance in type 2 diabetes. Recently, MR spectroscopy was adapted for in vivo measurement of triglycerides in animal models and for the characterization of new therapeutic approaches. Because of small MR spectroscopy voxel sizes used in skeletal muscles, surface coils are used for signal reception. Furthermore, to obtain well-resolved and undistorted lipid spectra, muscle fibers must be aligned parallel to the magnetic field. Consequently, to achieve a high signal-to-noise ratio and spectral quality, a coil setup must combine high sensitivity with a reliable and reproducible positioning of muscle and voxel. These demands are difficult to match using surface coils. Here, a coil platform is described, which uses inductively coupled Helmholtz coil setup combined with a leg retainer system for rats. The new system allows for measurement of intramyocellular lipids with high signal-to-noise ratio and for significantly improved animal handling, positioning, and throughput.

journal_name

Magn Reson Med

authors

Neumaier M,Niessen HG,Kaulisch T,Stiller D

doi

10.1002/mrm.22149

subject

Has Abstract

pub_date

2009-10-01 00:00:00

pages

1036-41

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

62

pub_type

杂志文章
  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.

    abstract::The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10509

    authors: Sampath S,Derbyshire JA,Atalar E,Osman NF,Prince JL

    更新日期:2003-07-01 00:00:00

  • Fast Fourier imaging.

    abstract::A new NMR imaging technique, aiming at a reduction of the data acquisition time, is described in detail. The method is applicable in all multidimensional imaging situations where at least one spatial coordinate is resolved. Discussed at some length are the point-spread function, the required bandwidth of the NMR spect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020304

    authors: van Uijen CM,den Boef JH,Verschuren FJ

    更新日期:1985-06-01 00:00:00

  • Differentiation between cortical atrophy and hydrocephalus using 1H MRS.

    abstract::Quantitative 1H MRS to determine cerebral metabolite patterns and MRI to determine CSF flow were applied to 12 patients with ventricular dilation-Group A, cortical atrophy (N = 5); or Group B, hydrocephalus (N = 7)- and in 9 normal controls. While mean brain water (Group A = 80% +/- 6; Group B = 86% +/- 5; normal = 85...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370317

    authors: Bluml S,McComb JG,Ross BD

    更新日期:1997-03-01 00:00:00

  • Three-dimensional magnetization-prepared time-of-flight MR angiography of the carotid and vertebral arteries.

    abstract::Three-dimensional magnetization-prepared (MP) MR angiography (MRA) was applied to the carotid and vertebral arteries by using ECG triggering, a slab selective RF inversion pulse, centric phase encoding and acquisition during diastole. Both theoretically and experimentally, the MP MRA sequence was shown to perform well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370219

    authors: Wilman AH,Huston J 3rd,Riederer SJ

    更新日期:1997-02-01 00:00:00

  • In vivo measurements of bone marrow cellularity using volume-localized proton NMR spectroscopy.

    abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190108

    authors: Ballon D,Jakubowski A,Gabrilove J,Graham MC,Zakowski M,Sheridan C,Koutcher JA

    更新日期:1991-05-01 00:00:00

  • Bayesian inference of hemodynamic changes in functional arterial spin labeling data.

    abstract::The study of brain function using MRI relies on acquisition techniques that are sensitive to different aspects of the hemodynamic response contiguous to areas of neuronal activity. For this purpose different contrasts such as arterial spin labeling (ASL) and blood oxygenation level dependent (BOLD) functional MRI tech...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21039

    authors: Woolrich MW,Chiarelli P,Gallichan D,Perthen J,Liu TT

    更新日期:2006-10-01 00:00:00

  • Simultaneous assessment of cardiac metabolism and perfusion using copolarized [1-13 C]pyruvate and 13 C-urea.

    abstract:PURPOSE:To demonstrate the feasibility of imaging a bolus of co-polarized [1-13 C]pyruvate and 13 C-urea to simultaneously assess both metabolism and perfusion in the rodent heart. METHODS:Copolarized [1-13 C]pyruvate and 13 C-urea was imaged using a multi-echo, flow-sensitized spiral pulse sequence. Healthy rats were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26106

    authors: Lau AZ,Miller JJ,Robson MD,Tyler DJ

    更新日期:2017-01-01 00:00:00

  • PLANET: An ellipse fitting approach for simultaneous T1 and T2 mapping using phase-cycled balanced steady-state free precession.

    abstract:PURPOSE:To demonstrate the feasibility of a novel, ellipse fitting approach, named PLANET, for simultaneous estimation of relaxation times T1 and T2 from a single 3D phase-cycled balanced steady-state free precession (bSSFP) sequence. METHODS:A method is presented in which the elliptical signal model is used to descri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26717

    authors: Shcherbakova Y,van den Berg CAT,Moonen CTW,Bartels LW

    更新日期:2018-02-01 00:00:00

  • Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

    abstract:PURPOSE:To develop a strategy for training a physics-guided MRI reconstruction neural network without a database of fully sampled data sets. METHODS:Self-supervised learning via data undersampling (SSDU) for physics-guided deep learning reconstruction partitions available measurements into two disjoint sets, one of wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28378

    authors: Yaman B,Hosseini SAH,Moeller S,Ellermann J,Uğurbil K,Akçakaya M

    更新日期:2020-12-01 00:00:00

  • Quantitative diffusion imaging in implanted human breast tumors.

    abstract::Quantitative diffusion measurements were performed in tumors arising from inoculation of nude mice with two human breast cancer cell lines (MCF7 and T47D) to evaluate the specificity of this technique for characterizing solid tumors. ADC maps were compared to histology and correlated well with gross tumor morphology. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370417

    authors: Maier CF,Paran Y,Bendel P,Rutt BK,Degani H

    更新日期:1997-04-01 00:00:00

  • Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction.

    abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26730

    authors: Moghari MH,Uecker M,Roujol S,Sabbagh M,Geva T,Powell AJ

    更新日期:2018-02-01 00:00:00

  • Direct comparison of in vivo versus postmortem second-order motion-compensated cardiac diffusion tensor imaging.

    abstract:PURPOSE:To directly compare in vivo versus postmortem second-order motion-compensated spin-echo diffusion tensor imaging of the porcine heart. METHODS:Second-order motion-compensated spin-echo cardiac diffusion tensor imaging was performed during systolic contraction in vivo and repeated upon cardiac arrest by bariumc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26871

    authors: Stoeck CT,von Deuster C,Fleischmann T,Lipiski M,Cesarovic N,Kozerke S

    更新日期:2018-04-01 00:00:00

  • MRI relaxation fluctuations in acute reperfused hemorrhagic infarction.

    abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21079

    authors: Foltz WD,Yang Y,Graham JJ,Detsky JS,Wright GA,Dick AJ

    更新日期:2006-12-01 00:00:00

  • Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

    abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10358

    authors: Kim J,Prince MR,Zabih R,Bezanson J,Watts R,Erel HE,Wang Y

    更新日期:2002-12-01 00:00:00

  • Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

    abstract:PURPOSE:To develop and evaluate a novel two-dimensional self-gated imaging technique for free-breathing cardiac cine MRI that is free of motion-detection overhead and requires minimal planning for motion tracking. METHODS:Motion along the readout direction was extracted solely from normal Cartesian imaging readouts ne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25834

    authors: Guo L,Derbyshire JA,Herzka DA

    更新日期:2016-08-01 00:00:00

  • Comparison of diffusion- and T2-weighted MRI for the early detection of cerebral ischemia and reperfusion in rats.

    abstract::The sensitivity of diffusion-weighted MRI was compared to that of T2-weighted MRI following temporary middle cerebral artery occlusion (MCA-O) for 33 min followed by 4 h of reperfusion in rats. Diffusion-weighted spin-echo images using strong gradients (b value of 1413 s/mm2) demonstrated a significant increase in sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180106

    authors: Mintorovitch J,Moseley ME,Chileuitt L,Shimizu H,Cohen Y,Weinstein PR

    更新日期:1991-03-01 00:00:00

  • Phase-based T2 mapping with gradient echo imaging.

    abstract:PURPOSE:Transverse relaxation time (T2 ) mapping with MRI has a plethora of clinical and research applications. Current T2 mapping techniques are based primarily on spin-echo (SE) relaxometry strategies that rely on the signal magnitude, and often suffer from lengthy acquisition times. In this work, we propose a phase-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28138

    authors: Wang X,Hernando D,Reeder SB

    更新日期:2020-08-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • Artifacts and signal loss due to flow in the presence of B(o) inhomogeneity.

    abstract::An in vitro study was performed to investigate the effects of B(o) inhomogeneity on magnetic resonance images of flow. Controlled inhomogeneity gradients (Gi) were applied and the magnitude of the artifacts produced was quantified for different echo delay times (TE). Both steady and pulsatile flows were examined. In t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350116

    authors: Drangova M,Pelc NJ

    更新日期:1996-01-01 00:00:00

  • Uniform spinning sampling gradient electron paramagnetic resonance imaging.

    abstract:PURPOSE:To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS:A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24712

    authors: Johnson DH,Ahmad R,Liu Y,Chen Z,Samouilov A,Zweier JL

    更新日期:2014-02-01 00:00:00

  • A new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.

    abstract::TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22766

    authors: Ding Y,Chung YC,Jekic M,Simonetti OP

    更新日期:2011-06-01 00:00:00

  • Improved activation maps via the elimination of motion effects through time-domain mixing of data in conventional gradient echo functional MRI.

    abstract::To date, most functional imaging centers have relied on ultrafast imaging approaches such as echo-planar imaging (EPI) techniques for acquiring functional brain activation data. These methods require specialized hardware and are not yet installed widely on clinical MR imagers, thus limiting the application of function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380417

    authors: Constable RT

    更新日期:1997-10-01 00:00:00

  • A ranking of diffusion MRI compartment models with in vivo human brain data.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) microstructure imaging provides a unique noninvasive probe into tissue microstructure. The technique relies on biophysically motivated mathematical models, relating microscopic tissue features to the magnetic resonance (MR) signal. This work aims to determine which com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25080

    authors: Ferizi U,Schneider T,Panagiotaki E,Nedjati-Gilani G,Zhang H,Wheeler-Kingshott CA,Alexander DC

    更新日期:2014-12-01 00:00:00

  • Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

    abstract::This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24362

    authors: Kaiser J,Bradford R,Johnson K,Wieben O,Thelen DG

    更新日期:2013-05-01 00:00:00

  • Real-time Triggered RAdial Single-Shot Inversion recovery for arrhythmia-insensitive myocardial T1 mapping: motion phantom validation and in vivo comparison.

    abstract:PURPOSE:Cardiac T1 mapping has become an increasingly important imaging technique, contributing novel diagnostic options. However, currently utilized methods are often associated with accuracy problems because of heart rate variations and cardiac arrhythmia, limiting their value in clinical routine. This study aimed to...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27526

    authors: Gensler D,Salinger T,Düring M,Lorenz K,Jahns R,Wech T,Frantz S,Ertl G,Jakob PM,Nordbeck P

    更新日期:2019-03-01 00:00:00

  • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

    abstract::The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20440

    authors: Steger TR,White RA,Jackson EF

    更新日期:2005-04-01 00:00:00

  • An analytical solution to the dispersion-by-inversion problem in magnetic resonance elastography.

    abstract:PURPOSE:Magnetic resonance elastography (MRE) measures stiffness of soft tissues by analyzing their spatial harmonic response to externally induced shear vibrations. Many MRE methods use inversion-based reconstruction approaches, which invoke first- or second-order derivatives by finite difference operators (first- and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28247

    authors: Mura J,Schrank F,Sack I

    更新日期:2020-07-01 00:00:00

  • Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

    abstract::Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400517

    authors: Jesmanowicz A,Bandettini PA,Hyde JS

    更新日期:1998-11-01 00:00:00

  • In vivo and ex vivo MR imaging of slowly cycling melanoma cells.

    abstract::Slowly cycling cells are believed to play a critical role in tumor progression and metastatic dissemination. The goal of this study was to develop a method for in vivo detection of slowly cycling cells. To distinguish these cells from more rapidly proliferating cells that constitute the vast majority of cells in tumor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22917

    authors: Magnitsky S,Roesch A,Herlyn M,Glickson JD

    更新日期:2011-11-01 00:00:00