Rapid and motion-robust volume coverage using cross-sectional real-time MRI.

Abstract:

PURPOSE:To develop a rapid and motion-robust technique for volumetric MRI, which is based on cross-sectional real-time MRI acquisitions with automatic advancement of the slice position. METHODS:Real-time MRI with a frame-by-frame moving cross-section is performed with use of highly undersampled radial gradient-echo sequences offering spin density, T1 , or T2 /T1 contrast. Joint reconstructions of serial images and coil sensitivity maps from spatially overlapping sections are accomplished by nonlinear inversion with regularization to the preceding section-formally identical to dynamic real-time MRI. Shifting each frame by 20% to 25% of the section thickness ensures 75% to 80% overlap of successive sections. Acquisition times of 40 to 67 ms allow for rates of 15 to 25 sections per second, while volumes are defined by the number of cross-sections times the section shift. RESULTS:Preliminary realizations at 3T comprise studies of the human brain, carotid arteries, liver, and prostate. Typically, coverage of a 90- to 180-mm volume at 0.8- to 1.2-mm in-plane resolution, 4- to 6-mm section thickness, and 0.8- to 1.5-mm section shift is accomplished within total measuring times of 4 to 6 seconds and a section speed of 15 to 37.5 mm per second. However, spatiotemporal resolution, contrast including options such as fat saturation and total measuring time are highly variable and may be adjusted to clinical needs. Promising volumetric applications range from fetal MRI to dynamic contrast-enhanced MRI. CONCLUSION:The proposed method allows for rapid and motion-robust volume coverage in a variety of imaging scenarios.

journal_name

Magn Reson Med

authors

Voit D,Kalentev O,van Zalk M,Joseph AA,Frahm J

doi

10.1002/mrm.28029

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

1652-1658

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

83

pub_type

杂志文章
  • Simultaneous measurement of intracellular and extracellular oxygen concentrations using a nitroxide-liposome system.

    abstract::The concentration of oxygen within cells is important in many physiological and pathological processes, but such oxygen-dependent phenomena are generally studied as a function of the concentration of extracellular oxygen, due to a lack of suitable methods. Electron parmamagnetic resonance (EPR) oximetric techniques of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290105

    authors: Glockner JF,Norby SW,Swartz HM

    更新日期:1993-01-01 00:00:00

  • Imaging of single human carcinoma cells in vitro using a clinical whole-body magnetic resonance scanner at 3.0 T.

    abstract::The purpose of the present study was to examine whether single human carcinoma cells labeled with iron oxide nanoparticles could be detected by magnetic resonance (MR) imaging on a clinical 3-T scanner using a surface coil only. WiDr human colon carcinoma cells were loaded with two kinds of iron oxide nanoparticles di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20455

    authors: Pinkernelle J,Teichgräber U,Neumann F,Lehmkuhl L,Ricke J,Scholz R,Jordan A,Bruhn H

    更新日期:2005-05-01 00:00:00

  • Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging.

    abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24824

    authors: Lee SK,Tan ET,Govenkar A,Hancu I

    更新日期:2014-05-01 00:00:00

  • Common k-space acquisition: a method to improve myocardial grid-tag contrast.

    abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370519

    authors: Doyle M,Walsh EG,Foster RE,Pohost GM

    更新日期:1997-05-01 00:00:00

  • Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisition.

    abstract::Spatial resolution in 3D breath-hold coronary MR angiography (MRA) is limited by imaging time. The purpose of this work was to investigate the feasibility of improving the spatial resolution of coronary MRA using generalized autocalibrating partially parallel acquisition (GRAPPA) and fast imaging with steady state pre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20153

    authors: Park J,McCarthy R,Li D

    更新日期:2004-07-01 00:00:00

  • Quantification of fluid changes in rat leg joints with adjuvant arthritis by a one-dimensional magnetic resonance imaging experiment.

    abstract::A simple and reliable method for quantifying the fluid content and characterizing the tissue T2 relaxation properties of animal extremities has been devised. This one-dimensional magnetic resonance imaging experiment, applied to the adjuvant arthritis model in rats, provides a useful, noninvasive monitor of the course...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150208

    authors: Borah B,Szeverenyi NM

    更新日期:1990-08-01 00:00:00

  • Continuously moving table MRI with golden angle radial sampling.

    abstract:PURPOSE:Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole-body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arb...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25531

    authors: Sengupta S,Smith DS,Welch EB

    更新日期:2015-12-01 00:00:00

  • Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T.

    abstract::The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>

    authors: Calamante F,Lythgoe MF,Pell GS,Thomas DL,King MD,Busza AL,Sotak CH,Williams SR,Ordidge RJ,Gadian DG

    更新日期:1999-03-01 00:00:00

  • Resolution-recovery for EPR imaging of free radical molecules in mice.

    abstract::A method of post-processing to enhance the image resolution of the distribution of free radical molecules obtained with continuous-wave electron paramagnetic resonance (CW-EPR) imaging is reported. The low spatial resolution of EPR imaging, which has created difficulties in biomedical applications, was overcome by the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22029

    authors: Ikebata Y,Sato-Akaba H,Aoyama T,Fujii H,Itoh K,Hirata H

    更新日期:2009-09-01 00:00:00

  • Impact of capped and uncapped abandoned leads on the heating of an MR-conditional pacemaker implant.

    abstract:PURPOSE:To assess the risk of radiofrequency (RF)-induced heating in patients with MR-conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant. METHODS:Four commercial pacemaker leads were placed beside a MR-conditional PM system, inside a human trunk simulator. The phantom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25106

    authors: Mattei E,Gentili G,Censi F,Triventi M,Calcagnini G

    更新日期:2015-01-01 00:00:00

  • Commutator filter: a novel technique for the identification of structures producing significant susceptibility inhomogeneities and its application to functional MRI.

    abstract::A robust postprocessing method to detect regions of magnetic field change is presented. High resolution gradient echo data is acquired to create a complex baseline image. From this image, two low resolution images are obtained by applying a low pass filter on the magnitude image and the complex image, respectively. Su...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360518

    authors: Lai S,Reichenbach JR,Haacke EM

    更新日期:1996-11-01 00:00:00

  • Multi-turn transmit coil to increase b1 efficiency in current source amplification.

    abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24612

    authors: Gudino N,Griswold MA

    更新日期:2013-04-01 00:00:00

  • Simulation-based investigation of partially parallel imaging with a linear array at high accelerations.

    abstract::Partially parallel imaging strategies such as SMASH, SENSE, and PILS rely on the sensitivity distribution of phased array RF coils to reduce MRI imaging time. Using an N-element phased array, these techniques allow maximum accelerations, L, such that L < or = N, with acceleration defined as the factor by which scan ti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10113

    authors: Bankson JA,Wright SM

    更新日期:2002-04-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

    abstract:PURPOSE:To study the feasibility of black-blood contrast in native T1 mapping for reduction of partial voluming at the blood-myocardium interface. METHODS:A saturation pulse prepared heart-rate-independent inversion recovery (SAPPHIRE) T1 mapping sequence was combined with motion-sensitized driven-equilibrium (MSDE) b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26378

    authors: Weingärtner S,Meßner NM,Zöllner FG,Akçakaya M,Schad LR

    更新日期:2017-08-01 00:00:00

  • 1H NMR relaxation measurements of human tissues in situ by spatially resolved spectroscopy.

    abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040504

    authors: Luyten PR,Anderson CM,den Hollander JA

    更新日期:1987-05-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Flow-suppressed hyperpolarized 13 C chemical shift imaging using velocity-optimized bipolar gradient in mouse liver tumors at 9.4 T.

    abstract:PURPOSE:To optimize and investigate the influence of bipolar gradients for flow suppression in metabolic quantification of hyperpolarized 13 C chemical shift imaging (CSI) of mouse liver at 9.4 T. METHODS:The trade-off between the amount of flow suppression using bipolar gradients and T2* effect from static spins was ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26578

    authors: Lee H,Lee J,Joe E,Yang S,Song JE,Choi YS,Wang E,Joo CG,Song HT,Kim DH

    更新日期:2017-11-01 00:00:00

  • Improved sensitivity to overlapping multiplet signals in in vivo proton spectroscopy using a multiecho volume selective (CPRESS) experiment.

    abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370603

    authors: Hennig J,Thiel T,Speck O

    更新日期:1997-06-01 00:00:00

  • T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

    abstract::T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22178

    authors: Raya JG,Dietrich O,Horng A,Weber J,Reiser MF,Glaser C

    更新日期:2010-01-01 00:00:00

  • Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.

    abstract:PURPOSE:For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25507

    authors: Ahmad R,Xue H,Giri S,Ding Y,Craft J,Simonetti OP

    更新日期:2015-11-01 00:00:00

  • Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations.

    abstract:PURPOSE:MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element-based simulations were performed to explore this pos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26333

    authors: McGrath DM,Ravikumar N,Beltrachini L,Wilkinson ID,Frangi AF,Taylor ZA

    更新日期:2017-07-01 00:00:00

  • Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample.

    abstract:PURPOSE:We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS:We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25646

    authors: Deniz CM,Vaidya MV,Sodickson DK,Lattanzi R

    更新日期:2016-01-01 00:00:00

  • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI.

    abstract::Higher field strengths entail less homogeneous RF fields. This may influence quantitative MRI and MRS. A method for rapidly mapping the RF field in the human head with minimal distortion was developed on the basis of a single-shot stimulated echo acquisition mode (STEAM) sequence. The flip angle of the second RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21676

    authors: Helms G,Finsterbusch J,Weiskopf N,Dechent P

    更新日期:2008-09-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • Volume-localized measurement of oxygen extraction fraction in the brain using MRI.

    abstract:PURPOSE:T2 -relaxation-under-spin-tagging (TRUST) is an MR technique for the non-invasive assessment of whole-brain cerebral oxygen extraction fraction (OEF), through measurement of the venous blood T2 relaxation time in the sagittal sinus. A key limitation of TRUST, however, is the lack of spatial specificity of the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27823

    authors: O'Brien C,Okell TW,Chiew M,Jezzard P

    更新日期:2019-10-01 00:00:00

  • The development of a pH-sensitive contrast agent for NMR 1H imaging.

    abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050313

    authors: Helpern JA,Curtis JC,Hearshen D,Smith MB,Welch KM

    更新日期:1987-09-01 00:00:00

  • Quantification of atherosclerotic plaque components using in vivo MRI and supervised classifiers.

    abstract::In this work we aimed to study the possibility of using supervised classifiers to quantify the main components of carotid atherosclerotic plaque in vivo on the basis of multisequence MRI data. MRI data consisting of five MR weightings were obtained from 25 symptomatic subjects. Histological micrographs of endarterecto...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20828

    authors: Hofman JM,Branderhorst WJ,ten Eikelder HM,Cappendijk VC,Heeneman S,Kooi ME,Hilbers PA,ter Haar Romeny BM

    更新日期:2006-04-01 00:00:00

  • Single-shot, three-dimensional "non-echo" localization method for in vivo NMR spectroscopy.

    abstract::Metabolite signals with short T(1) or T(2) are difficult to localize with full sensitivity. This limitation was overcome with the development and implementation of a single-shot, complete three-dimensional "non-echo" localization method with reduced sensitivity to spatial B(1) variation, which is suitable for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<387::aid-mrm8>3.0.co

    authors: Choi IY,Tkác I,Gruetter R

    更新日期:2000-09-01 00:00:00

  • Atraumatic quantitation of cerebral perfusion in cats by 19F magnetic resonance imaging.

    abstract::We have noninvasively produced low-resolution, quantitative nuclear magnetic resonance images of cerebral blood flow in 2-ml voxels in eight cats. Typical signal-to-noise of 4 to 1 was obtained in cerebral voxels in 16.5-s epochs. Mean flow during normocapnia (paCO2 = 39 +/- 4 mm Hg) and hypercapnia (paCO2 = 62 +/- 4 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280105

    authors: Branch CA,Ewing JR,Helpern JA,Ordidge RJ,Butt S,Welch KM

    更新日期:1992-11-01 00:00:00