Abstract:
:Partially parallel imaging strategies such as SMASH, SENSE, and PILS rely on the sensitivity distribution of phased array RF coils to reduce MRI imaging time. Using an N-element phased array, these techniques allow maximum accelerations, L, such that L < or = N, with acceleration defined as the factor by which scan time is reduced in comparison to traditional, fully gradient encoded acquisitions. As N increases in modern MRI facilities or using special hardware extensions, its role as the primary limitation in partially parallel imaging will be reduced and other limiting factors will become dominant. Two such factors include available SNR and the variation of sensitivity distributions with imaging depth. Simulations have been conducted to evaluate the impact of slice depth and noise on partially parallel reconstructions for the case of a square linear array of overlapped elements that are parallel to the imaging plane. Results indicate that even when sensitivity distributions are exactly known, the linear surface array can only provide high accelerations over a limited imaging depth due to changing suitability of the sensitivity distributions for partially parallel reconstruction. This work emphasizes the importance of simulations for target-based partially parallel array design.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Bankson JA,Wright SMdoi
10.1002/mrm.10113subject
Has Abstractpub_date
2002-04-01 00:00:00pages
777-86issue
4eissn
0740-3194issn
1522-2594pii
10.1002/mrm.10113journal_volume
47pub_type
杂志文章abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26309
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27177
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:To evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. THEORY:The extended phase graph (EPG) algorithm, originally designed to model the effe...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27058
更新日期:2018-08-01 00:00:00
abstract::Comparative NMR studies of normal and pathologically altered human stomach tissues were performed on the basis of proton T1 relaxation time measurements in the presence of high external concentrations of relaxation (contrast) agents manganese ethylenediaminetetraacetic acid (Mn-EDTA) and gadolinium diethylenetriaminep...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910150313
更新日期:1990-09-01 00:00:00
abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26910
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:High-resolution three-dimensional (3D) structural MRI is useful for delineating complex or small structures of the body. However, it requires long acquisition times and high SAR, limiting its clinical use. The purpose of this work is to accelerate the acquisition of high-resolution images by combining compresse...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27789
更新日期:2019-09-01 00:00:00
abstract::Leakage of Gd-DTPA through a defective blood-brain barrier is measured quantitatively using dynamic MRI scanning, in which repeated scans are made after a bolus injection. Image registration artifacts are minimized; a dose of 0.1 mM/kg and an IR sequence enable enhancement to be measured quantitatively. The triexponen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910170208
更新日期:1991-02-01 00:00:00
abstract::Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22038
更新日期:2009-09-01 00:00:00
abstract::Human brain white matter exhibits an uncommonly strong dispersion of 1/T1 at high fields. An additional relaxation pathway via the myelin lipids, which are not directly visible to medical NMR due to their fast T2 decay, is proposed. Relaxation dispersion data are successfully analyzed on the basis of this model. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910090319
更新日期:1989-03-01 00:00:00
abstract::ECG-gated cardiac MRI in the mouse is hindered by many technical difficulties in ECG signal recording inside static and variable high magnetic scanner fields. The present study proposes an alternative robust method of acquiring auto-gated cardiac and respiratory cine images in mouse heart. In our approach, a motion sy...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20815
更新日期:2006-03-01 00:00:00
abstract::Diffusion-weighted single voxel experiments conducted at b-values up to 1 x 10(4) smm-2 yielded biexponential signal attenuation curves for both normal and ischemic brain. The relative fractions of the rapidly and slowly decaying components (f1, f2) are f1 = 0.80 +/- 0.02, f2 = 0.17 +/- 0.02 in healthy adult rat brain...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360607
更新日期:1996-12-01 00:00:00
abstract::In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion,...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190220
更新日期:1991-06-01 00:00:00
abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24902
更新日期:2014-07-01 00:00:00
abstract::When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910220117
更新日期:1991-11-01 00:00:00
abstract::High-signal artifacts produced by cerebrospinal fluid (CSF) flow can adversely affect fluid-attenuated inversion recovery (FLAIR) imaging of the brain and spinal cord. This study explores the use of a nonslice-selective inversion pulse to eliminate CSF flow artifacts together with a technique called "K-space Reordered...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1198
更新日期:2001-08-01 00:00:00
abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050313
更新日期:1987-09-01 00:00:00
abstract::Quantitative MRI assessment of leukoencephalopathy is difficult because the MRI properties of leukoencephalopathy significantly overlap those of normal tissue. This report describes the use of an automated procedure for longitudinal measurement of tissue volume and relaxation times to quantify leukoencephalopathy. Ima...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1002/mrm.10124
更新日期:2002-05-01 00:00:00
abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910170128
更新日期:1991-01-01 00:00:00
abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24129
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26144
更新日期:2017-02-01 00:00:00
abstract::A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear pol...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10392
更新日期:2003-03-01 00:00:00
abstract::We have demonstrated that echo-planar imaging can be used to produce high-quality snapshot images of the human fetus in utero in a fraction of a second. These images are free of motional artifact or blurring and allow detailed depiction of fetal structures in normal and pathological pregnancies. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910130214
更新日期:1990-02-01 00:00:00
abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21648
更新日期:2008-07-01 00:00:00
abstract::A new spherical navigator echo (SNAV) registration technique is presented. This technique starts by collecting a set of SNAV templates at a reference position. These templates are acquired by rotating the gradient system to result in rotation angles that uniformly cover a predefined range of rotation. The rotation ang...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22629
更新日期:2011-02-01 00:00:00
abstract::For MR applications such as contrast-enhanced MR angiography, it is desirable to achieve simultaneously high spatial and temporal resolution. The current clinical standard uses view-sharing methods combined with parallel imaging; however, this approach still provides limited spatial and temporal resolution. To improve...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22814
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28591
更新日期:2020-11-21 00:00:00
abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24612
更新日期:2013-04-01 00:00:00
abstract::MR images acquired by using an arterial spin-labeling technique showed spatial and temporal variations of perfusion in the skeletal muscle of exercising humans. Perfusion measurements made during plantar flexion exercise in normal volunteers were consistent with those obtained by traditional techniques reported in the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199908)42:2<258::aid-mrm7>
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:To develop velocity-selective (VS) MR angiography (MRA) protocols for arteriography and venography with whole-brain coverage. METHODS:Tissue suppression using velocity-selective saturation (VSS) pulse trains is sensitive to radiofrequency field (B1 +) inhomogeneity. To reduce its sensitivity, we replaced the l...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26864
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:We sought to develop and test a clinically feasible 1-point Dixon, three-dimensional (3D) radial acquisition strategy to create isotropic 3D MR images of (129)Xe in the airspaces, barrier, and red blood cells (RBCs) in a single breath. The approach was evaluated in healthy volunteers and subjects with idiopathi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25675
更新日期:2016-04-01 00:00:00