In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-field ESR-based techniques.

Abstract:

:A study was made of the in vivo detectability of a pH-sensitive, imidazolidine spin probe, and the efficacy of low-frequency electron spin resonance (ESR)-based techniques for pH measurement in vitro and in vivo in rats. The techniques used were longitudinally-detected ESR (LODESR) and field-cycled dynamic nuclear polarization (FC-DNP) for in vitro and in vivo measurements, and radiofrequency (RF)- and X-band ESR for comparisons in vitro. The spin probe was hexamethyl imidazolidine (HMI) with a pK of 4.6. All techniques detected HMI. Detection by FC-DNP implies coupling between the free radical and solvent water spins. Separations between the three spectral lines of the nitroxide radical, relative to measurement frequency, were consistent with theory. The overall spectrum width from unprotonated HMI (pH > pK) was greater than that from protonated agent (pH < pK). This was observed in vitro and in vivo. Longer-term studies showed that HMI is detectable and has the same spectral width (i.e., is at the same pH) up to 2 hr after gavage into the stomach, although the magnitude of the signal decreases rapidly during the first hour. These findings demonstrate the suitability of LODESR and FC-DNP for monitoring HMI and measuring pH in vivo. These techniques would be useful for monitoring disease and drug pharmacology in the living system.

journal_name

Magn Reson Med

authors

Foster MA,Grigor'ev IA,Lurie DJ,Khramtsov VV,McCallum S,Panagiotelis I,Hutchison JM,Koptioug A,Nicholson I

doi

10.1002/mrm.10392

subject

Has Abstract

pub_date

2003-03-01 00:00:00

pages

558-67

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

49

pub_type

杂志文章
  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • 2D multislice and 3D MRI sequences are often equally sensitive.

    abstract::A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<824::aid-mrm23

    authors: Johnson G,Wadghiri YZ,Turnbull DH

    更新日期:1999-04-01 00:00:00

  • Initial investigation of a novel noninvasive weight loss therapy using MRI-Guided high intensity focused ultrasound (MR-HIFU) of visceral fat.

    abstract:PURPOSE:MRI-guided high intensity focused ultrasound (MR-HIFU) allows noninvasive heating of deep tissues. Specifically targeting visceral fat deposits with MR-HIFU could offer an effective therapy for reversing the development of obesity, diabetes, and metabolic syndrome. METHODS:Overweight rats received either MR-HI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25883

    authors: Winter PM,Lanier M,Partanen A,Dumoulin C

    更新日期:2016-07-01 00:00:00

  • Noise correlation.

    abstract::Calculations and experiments that provide support for our previously stated theorem are presented: If two coils simultaneously receiving magnetic resonance signals from the same anatomic region exhibit zero mutual inductance, there can be no correlation of the noise. It is shown that correlation does not exist even in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200105

    authors: Jesmanowicz A,Hyde JS,Froncisz W,Kneeland JB

    更新日期:1991-07-01 00:00:00

  • Improved compressed sensing and super-resolution of cardiac diffusion MRI with structure-guided total variation.

    abstract:PURPOSE:Structure-guided total variation is a recently introduced prior that allows reconstruction of images using knowledge of the location and orientation of edges in a reference image. In this work, we demonstrate the advantages of a variant of structure-guided total variation known as directional total variation (D...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28245

    authors: Teh I,McClymont D,Carruth E,Omens J,McCulloch A,Schneider JE

    更新日期:2020-10-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Mapping of regional lung microstructural parameters using hyperpolarized 129 Xe dissolved-phase MRI in healthy volunteers and patients with chronic obstructive pulmonary disease.

    abstract:PURPOSE:To develop a novel technique for voxel-based mapping of lung microstructural parameters using hyperpolarized 129 Xe dissolved-phase MR imaging during saturation recovery. METHODS:A pulse sequence using a highly undersampled stack-of-stars trajectory was developed, and low-rank plus sparse matrix decomposition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27559

    authors: Kern AL,Gutberlet M,Voskrebenzev A,Klimeš F,Rotärmel A,Wacker F,Hohlfeld JM,Vogel-Claussen J

    更新日期:2019-04-01 00:00:00

  • Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging.

    abstract::This study characterizes gains in sensitivity and spectral resolution of proton echo-planar spectroscopic imaging (PEPSI) with increasing magnetic field strength (B(0)). Signal-to-noise ratio (SNR) per unit volume and unit time, and intrinsic linewidth (LW) of N-acetyl-aspartate (NAA), creatine (Cr), and choline (Cho)...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21067

    authors: Otazo R,Mueller B,Ugurbil K,Wald L,Posse S

    更新日期:2006-12-01 00:00:00

  • Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic device.

    abstract:PURPOSE:To develop a wideband cardiac perfusion pulse sequence and test whether it is capable of suppressing image artifacts in patients with a cardiac implantable electronic device (CIED), while not exceeding the specific absorption rate (SAR) limit (2.0 W/kg). METHODS:A wideband perfusion pulse sequence was develope...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27458

    authors: Hong K,Collins JD,Knight BP,Carr JC,Lee DC,Kim D

    更新日期:2019-02-01 00:00:00

  • Contributions of chemical exchange to T1ρ dispersion in a tissue model.

    abstract::Variations in T(1ρ) with locking-field strength (T(1ρ) dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross-linked polyacrylamide gels. These gels were varied in relative compositi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22947

    authors: Cobb JG,Xie J,Gore JC

    更新日期:2011-12-01 00:00:00

  • Time-domain combination of MR spectroscopy data acquired using phased-array coils.

    abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20244

    authors: Brown MA

    更新日期:2004-11-01 00:00:00

  • NMR changes in experimental allergic encephalomyelitis: NMR changes precede clinical and pathological events.

    abstract::In guinea pigs immunized with myelin basic protein (MBP) in complete Freund's adjuvant, experimental allergic encephalomyelitis (EAE) shows a characteristic clinical and pathological course. This study characterized the proton nuclear magnetic resonance (NMR) properties of the central nervous system prior to the onset...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050203

    authors: O'Brien JT,Noseworthy JH,Gilbert JJ,Karlik SJ

    更新日期:1987-08-01 00:00:00

  • Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

    abstract:PURPOSE:Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY:The method, T2-Relaxation-U...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24750

    authors: Krishnamurthy LC,Liu P,Ge Y,Lu H

    更新日期:2014-03-01 00:00:00

  • Longitudinal assessment of spinal cord injuries in nonhuman primates with quantitative magnetization transfer.

    abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25725

    authors: Wang F,Li K,Mishra A,Gochberg D,Min Chen L,Gore JC

    更新日期:2016-04-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • Improved steering of the RF field of traveling wave MR with a multimode, coaxial waveguide.

    abstract:PURPOSE:Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24807

    authors: Andreychenko A,Kroeze H,Boer VO,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-04-01 00:00:00

  • Quantitative fat and R2* mapping in vivo to measure lipid-rich necrotic core and intraplaque hemorrhage in carotid atherosclerosis.

    abstract:PURPOSE:The aim of this work was to quantify the extent of lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in atherosclerotic plaques. METHODS:Patients scheduled for carotid endarterectomy underwent four-point Dixon and T1-weighted magnetic resonance imaging (MRI) at 3 Tesla. Fat and R2* maps were gen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26359

    authors: Koppal S,Warntjes M,Swann J,Dyverfeldt P,Kihlberg J,Moreno R,Magee D,Roberts N,Zachrisson H,Forssell C,Länne T,Treanor D,de Muinck ED

    更新日期:2017-07-01 00:00:00

  • Intersubject specific absorption rate variability analysis through construction of 23 realistic body models for prostate imaging at 7T.

    abstract:PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27518

    authors: Meliadò EF,van den Berg CAT,Luijten PR,Raaijmakers AJE

    更新日期:2019-03-01 00:00:00

  • Advanced fit of the diffusion kurtosis tensor by directional weighting and regularization.

    abstract::The diffusional kurtosis is an indicator for diffusion restrictions in biological tissue. It is observed experimentally that the kurtosis is largest for directions perpendicular to the fiber direction in white matter. The directional dependence of the kurtosis can be described by the diffusion kurtosis tensor. Since t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23133

    authors: Kuder TA,Stieltjes B,Bachert P,Semmler W,Laun FB

    更新日期:2012-05-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • Total liver fat quantification using three-dimensional respiratory self-navigated MRI sequence.

    abstract:PURPOSE:MRI can produce quantitative liver fat fraction (FF) maps noninvasively, which can help to improve diagnoses of fatty liver diseases. However, most sequences acquire several two-dimensional (2D) slices during one or more breath-holds, which may be difficult for patients with limited breath-holding capacity. A w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26028

    authors: Arboleda C,Aguirre-Reyes D,García MP,Tejos C,Muñoz L,Miquel JF,Irarrazaval P,Andia ME,Uribe S

    更新日期:2016-11-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • Susceptibility mapping in the human brain using threshold-based k-space division.

    abstract::A method for calculating quantitative three-dimensional susceptibility maps from field measurements acquired using gradient echo imaging at high field is presented. This method is based on division of the three-dimensional Fourier transforms of high-pass-filtered field maps by a simple function that is the Fourier tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22334

    authors: Wharton S,Schäfer A,Bowtell R

    更新日期:2010-05-01 00:00:00

  • Simultaneous quantitative mapping of conductivity and susceptibility using a double-echo ultrashort echo time sequence: Example using a hematoma evolution study.

    abstract:PURPOSE:The primary purpose of this study is to propose a method for the simultaneous quantitative three-dimensional (3D) mapping of conductivity and susceptibility using double-echo ultrashort echo time (UTE) imaging. The secondary purpose is to investigate the changes of these properties over time during in vitro hem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25869

    authors: Gho SM,Shin J,Kim MO,Kim DH

    更新日期:2016-07-01 00:00:00

  • Intracellular and extracellular spaces and the direct quantification of molar intracellular concentrations of phosphorus metabolites in the isolated rat heart using 31P NMR spectroscopy and phosphonate markers.

    abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320206

    authors: Clarke K,Anderson RE,Nédélec JF,Foster DO,Ally A

    更新日期:1994-08-01 00:00:00

  • Fully balanced steady-state 3D-spin-echo (bSSSE) imaging at 3 Tesla.

    abstract::In this work a 3D fully balanced steady-state spin-echo sequence (bSSSE) was designed and implemented on a 3-Tesla whole-body MR scanner. In contrast to previously introduced nonbalanced SSSE (nbSSSE) sequences, bSSSE features fully rewound imaging gradients. Additionally, all phase encodings and the readout prephasin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21037

    authors: Krug R,Han ET,Banerjee S,Majumdar S

    更新日期:2006-11-01 00:00:00

  • Magnesium and pH imaging of the human brain at 3.0 Tesla.

    abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26

    authors: Barker PB,Butterworth EJ,Boska MD,Nelson J,Welch KM

    更新日期:1999-02-01 00:00:00

  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25101

    authors: Powell NJ,Jang A,Park JY,Valette J,Garwood M,Marjańska M

    更新日期:2015-01-01 00:00:00