Multidimensionally encoded magnetic resonance imaging.

Abstract:

:Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled.

journal_name

Magn Reson Med

authors

Lin FH

doi

10.1002/mrm.24443

subject

Has Abstract

pub_date

2013-07-01 00:00:00

pages

86-96

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

70

pub_type

杂志文章
  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Rigid-body motion correction with self-navigation MRI.

    abstract::The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21883

    authors: Mendes J,Kholmovski E,Parker DL

    更新日期:2009-03-01 00:00:00

  • Synchronous MRI of muscle motion induced by electrical stimulation.

    abstract:PURPOSE:Assessing the functionality of muscle fibers is essential to monitor both pathological and physiological processes. Here, we present a new method for accurate, quantitative measurement of muscle contraction with magnetic resonance imaging (MRI) using an electrical muscle stimulator (EMS), hence allowing the dir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26154

    authors: Deligianni X,Pansini M,Garcia M,Hirschmann A,Schmidt-Trucksäss A,Bieri O,Santini F

    更新日期:2017-02-01 00:00:00

  • Calculation of signal intensities in hybrid sequences for fast NMR imaging.

    abstract::A number of techniques that recently have been used for fast NMR-imaging are based on a hybrid sequence of echo planar imaging (EPI) and FLASH imaging: after each NMR excitation several k-space lines are measured. The complete k-space is covered by performance of several excitations. It has been observed that there is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340328

    authors: Deichmann R,Adolf H,Nöth U,Kuchenbrod E,Schwarzbauer C,Haase A

    更新日期:1995-09-01 00:00:00

  • Implementation of vascular-space-occupancy MRI at 7T.

    abstract::Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24334

    authors: Hua J,Jones CK,Qin Q,van Zijl PC

    更新日期:2013-04-01 00:00:00

  • Murine orthostatic response during prolonged vertical studies: effect on cerebral blood flow measured by arterial spin-labeled MRI.

    abstract::High-field MRI scanners are, in principle, well suited for mouse studies; however, many high-field magnets employ a vertical design that may influence the physiological state of the rodent. The purpose of this study was to investigate the orthostatic response of cerebral blood flow (CBF) in mice during a prolonged MR ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20621

    authors: Foley LM,Hitchens TK,Kochanek PM,Melick JA,Jackson EK,Ho C

    更新日期:2005-10-01 00:00:00

  • Strategy for the spectral filtering of myo-inositol and other strongly coupled spins.

    abstract::A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10697

    authors: Kim H,Wild JM,Allen PS

    更新日期:2004-02-01 00:00:00

  • Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone.

    abstract::Measurements of the volume magnetic susceptibility of solids using the classical Gouy balance approach are hampered by variations in apparent density of the packed powder. In this paper a quantitative NMR measurement of the volume magnetic susceptibility of powdered solids is described and the volume susceptibility of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370404

    authors: Hopkins JA,Wehrli FW

    更新日期:1997-04-01 00:00:00

  • Dynamic 13C NMR analysis of pyruvate and lactate oxidation in the in vivo canine myocardium: evidence of reduced utilization with increased work.

    abstract::In this work, substrate selection was monitored in the left ventricle of the canine myocardium by following pyruvate and lactate oxidation under in vivo conditions at basal and elevated workloads. These studies were conducted in the open chest model using dynamic 13C NMR techniques in the presence and absence of dichl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380608

    authors: Rath DP,Zhu H,Tong X,Jiang Z,Hamlin RL,Robitaille PM

    更新日期:1997-12-01 00:00:00

  • An analytical solution to the dispersion-by-inversion problem in magnetic resonance elastography.

    abstract:PURPOSE:Magnetic resonance elastography (MRE) measures stiffness of soft tissues by analyzing their spatial harmonic response to externally induced shear vibrations. Many MRE methods use inversion-based reconstruction approaches, which invoke first- or second-order derivatives by finite difference operators (first- and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28247

    authors: Mura J,Schrank F,Sack I

    更新日期:2020-07-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21614

    authors: Leupold J,Hennig J,Scheffler K

    更新日期:2008-07-01 00:00:00

  • Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

    abstract::The experiments reported herein are the first MRI investigations of the orientational dependence of T(2) relaxation in articular cartilage at microscopic resolution over the 360 degrees angular space. For each of six canine cartilage specimens, 48 independent T(2)-weighted proton images were acquired for 12 different ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10216

    authors: Xia Y,Moody JB,Alhadlaq H

    更新日期:2002-09-01 00:00:00

  • Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

    abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21095

    authors: Gabr RE,Aksit P,Bottomley PA,Youssef AB,Kadah YM

    更新日期:2006-12-01 00:00:00

  • Fast gated EPR imaging of the beating heart: spatiotemporally resolved 3D imaging of free-radical distribution during the cardiac cycle.

    abstract::In vivo or ex vivo electron paramagnetic resonance imaging (EPRI) is a powerful technique for determining the spatial distribution of free radicals and other paramagnetic species in living organs and tissues. However, applications of EPRI have been limited by long projection acquisition times and the consequent fact t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24250

    authors: Chen Z,Reyes LA,Johnson DH,Velayutham M,Yang C,Samouilov A,Zweier JL

    更新日期:2013-02-01 00:00:00

  • Generalized MR interferography.

    abstract::Generalized MR interferography allows the measurement of parameters which affect the phase of the MR signal. Interference is generated by the simultaneous generation of two echoes in one excitation cycle. Local variations of the signal phase are transformed into displacement of the stripe pattern generated by interfer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160305

    authors: Hennig J

    更新日期:1990-12-01 00:00:00

  • CINE turbo spin echo imaging.

    abstract::High-resolution turbo spin echo (TSE) images have demonstrated important details of carotid artery morphology; however, it is evident that pulsatile blood and wall motion related to the cardiac cycle are still significant sources of image degradation. Although ECG gating can reduce artifacts due to cardiac-induced pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22909

    authors: Mendes J,Parker DL,Hulet J,Treiman GS,Kim SE

    更新日期:2011-11-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • Chemically induced analgesic nephropathy in the rat monitored by proton-electron double-resonance imaging (PEDRI).

    abstract::Proton-electron double-resonance imaging (PEDRI) was used to assess renal function by monitoring the flow of the exogenous nitroxide free radical proxyl carboxylic acid (PCA) through normal and injured kidneys in the living rat. Kidney damage was induced by treatment with 2-bromoethylamine (BEA), which provides a well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400214

    authors: Seimenis I,Foster MA,Lurie DJ,Hutchison JM,Whiting PH,Payne S

    更新日期:1998-08-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

    abstract:PURPOSE:The goal of this study is to characterize and improve the accuracy of 2D magnetic resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 imperfections, which are two main factors that affect quantitative results in MRF. METHODS:The SP and B1 imperfections are characterized and correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26580

    authors: Ma D,Coppo S,Chen Y,McGivney DF,Jiang Y,Pahwa S,Gulani V,Griswold MA

    更新日期:2017-11-01 00:00:00

  • Comparison between 8- and 32-channel phased-array receive coils for in vivo hyperpolarized 13 C imaging of the human brain.

    abstract:PURPOSE:To compare the performance of an 8-channel surface coil/clamshell transmitter and 32-channel head array coil/birdcage transmitter for hyperpolarized 13 C brain metabolic imaging. METHODS:To determine the field homogeneity of the radiofrequency transmitters, B1 + mapping was performed on an ethylene glycol head...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27743

    authors: Autry AW,Gordon JW,Carvajal L,Mareyam A,Chen HY,Park I,Mammoli D,Vareth M,Chang SM,Wald LL,Xu D,Vigneron DB,Nelson SJ,Li Y

    更新日期:2019-08-01 00:00:00

  • A novel phase-unwrapping method based on pixel clustering and local surface fitting with application to Dixon water-fat MRI.

    abstract:PURPOSE:To develop and evaluate a novel 2D phase-unwrapping method that works robustly in the presence of severe noise, rapid phase changes, and disconnected regions. THEORY AND METHODS:The MR phase map usually varies rapidly in regions adjacent to wraps. In contrast, the phasors can vary slowly, especially in regions...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26647

    authors: Cheng J,Mei Y,Liu B,Guan J,Liu X,Wu EX,Feng Q,Chen W,Feng Y

    更新日期:2018-01-01 00:00:00

  • Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    abstract:PURPOSE:To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. METHODS:The difference in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26559

    authors: Wang Y,Zhang Y,Zhao X,Wu B,Gao JH

    更新日期:2017-11-01 00:00:00

  • Theory of heterogeneous relaxation in compartmentalized tissues.

    abstract::A new model of compartmentalized relaxation--that which occurs for spins (protons) exchanging between compartments of different relaxation rates--is presented. This model generalizes previous ones by allowing spatially dependent relaxation within compartments. Solutions for the diffusion-Bloch equations are found via ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370507

    authors: Barsky D,Pütz B,Schulten K

    更新日期:1997-05-01 00:00:00

  • Compartment size estimation with double wave vector diffusion-weighted imaging.

    abstract::Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21514

    authors: Koch MA,Finsterbusch J

    更新日期:2008-07-01 00:00:00

  • Prospective GIRF-based RF phase cycling to reduce eddy current-induced steady-state disruption in bSSFP imaging.

    abstract:PURPOSE:To propose an explicit Balanced steady-state free precession (bSSFP) signal model that predicts eddy current-induced steady-state disruptions and to provide a prospective, practical, and general eddy current compensation method. THEORY AND METHODS:Gradient impulse response functions (GIRF) were used to simulat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28097

    authors: Bruijnen T,Stemkens B,van den Berg CAT,Tijssen RHN

    更新日期:2020-07-01 00:00:00

  • Measurement of cerebral blood flow by volume-selective 19F NMR spectroscopy.

    abstract::A stimulated echo sequence was used to obtain 19F NMR spectra from within a 4-ml voxel in a cat brain. The time dependence of the 19F NMR signal from an inert gas (CHF3) was used to calculate the blood flow in the voxel. The position of the voxel was selected using a 1H MR image. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160316

    authors: van Zijl PC,Ligeti L,Sinnwell T,Alger JR,Chesnick AS,Moonen CT,McLaughlin AC

    更新日期:1990-12-01 00:00:00

  • In-plane "superresolution" MRI with phaseless sub-pixel encoding.

    abstract:PURPOSE:Acquisition of high-resolution imaging data using multiple excitations without the sensitivity to fluctuations of the transverse magnetization phase, which is a major problem of multi-shot MRI. THEORY AND METHODS:The concept of superresolution MRI based on microscopic tagging is analyzed using an analogy with ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27209

    authors: Hennel F,Tian R,Engel M,Pruessmann KP

    更新日期:2018-12-01 00:00:00

  • Susceptibility mapping in the human brain using threshold-based k-space division.

    abstract::A method for calculating quantitative three-dimensional susceptibility maps from field measurements acquired using gradient echo imaging at high field is presented. This method is based on division of the three-dimensional Fourier transforms of high-pass-filtered field maps by a simple function that is the Fourier tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22334

    authors: Wharton S,Schäfer A,Bowtell R

    更新日期:2010-05-01 00:00:00