Murine orthostatic response during prolonged vertical studies: effect on cerebral blood flow measured by arterial spin-labeled MRI.

Abstract:

:High-field MRI scanners are, in principle, well suited for mouse studies; however, many high-field magnets employ a vertical design that may influence the physiological state of the rodent. The purpose of this study was to investigate the orthostatic response of cerebral blood flow (CBF) in mice during a prolonged MR experiment in the vertical position. Arterial spin-labeled (ASL) MRI was performed at 4.7-Tesla with a 15-cm gradient insert that allowed horizontal and vertical CBF measurements to be obtained with the same scanner. For mice in the head-up (HU) vertical position, CBF decreased by approximately 40% compared to the horizontal position, although blood pressure did not differ. Furthermore, CBF values for vertically positioned mice treated with phenylephrine remained constant while blood pressure increased. These results support the conclusion that cerebral autoregulation was intact, albeit at a lower level. Since CBF recovers to near horizontal values by volume loading with saline, it appears that a decrease in central venous pressure (CVP) leading to an increase in sympathetic tone may be a contributing mechanism for lowered CBF. This suggests that using an HU vertical position for MRI in mice may have broader implications, especially for studies that rely on CBF (such as BOLD and fMRI).

journal_name

Magn Reson Med

authors

Foley LM,Hitchens TK,Kochanek PM,Melick JA,Jackson EK,Ho C

doi

10.1002/mrm.20621

subject

Has Abstract

pub_date

2005-10-01 00:00:00

pages

798-806

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

54

pub_type

杂志文章
  • Skeletal muscle ¹H MRSI before and after prolonged exercise. I. muscle specific depletion of intramyocellular lipids.

    abstract::Aim of the study was to determine distribution and depletion patterns of intramyocellular lipids (IMCL) in leg muscles before and after two types of standardized endurance exercise. ¹H-magnetic resonance spectroscopic imaging was performed (1) in the thigh of eight-trained cyclists after exercising on an ergometer for...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24168

    authors: Vermathen P,Saillen P,Boss A,Zehnder M,Boesch C

    更新日期:2012-11-01 00:00:00

  • Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T.

    abstract::The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>

    authors: Calamante F,Lythgoe MF,Pell GS,Thomas DL,King MD,Busza AL,Sotak CH,Williams SR,Ordidge RJ,Gadian DG

    更新日期:1999-03-01 00:00:00

  • Multidimensionally encoded magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24443

    authors: Lin FH

    更新日期:2013-07-01 00:00:00

  • Dynamic per slice shimming for simultaneous brain and spinal cord fMRI.

    abstract:PURPOSE:Simultaneous brain and spinal cord functional MRI is emerging as a new tool to study the central nervous system but is challenging. Poor B0 homogeneity and small size of the spinal cord are principal obstacles to this nascent technology. Here we extend a dynamic shimming approach, first posed by Finsterbusch, b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27388

    authors: Islam H,Law CSW,Weber KA,Mackey SC,Glover GH

    更新日期:2019-02-01 00:00:00

  • Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

    abstract::Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20221

    authors: Jochimsen TH,Norris DG,Mildner T,Möller HE

    更新日期:2004-10-01 00:00:00

  • Detection of significant features and statistical analysis of 2D and 3D images of 31P metabolites.

    abstract::The application of spectroscopy techniques to the study of normal and pathological tissue is currently limited by the difficulties of acquiring precisely localized spectra and analyzing the resulting, relatively low signal-to-noise data. Interpretation of multivoxel spectroscopy data is greatly facilitated by estimati...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250109

    authors: Nelson SJ,Vigneron DB,Brown TR

    更新日期:1992-05-01 00:00:00

  • Recovery of the rodent brain after cardiac arrest: a functional MRI study.

    abstract::Recovery of the cerebral cortex after 10 min of cardiac arrest was studied in rat using noninvasive MRI techniques. The apparent diffusion coefficient (ADC) of brain water was imaged to document reversal of the metabolic impairment. Perfusion-weighted imaging and blood oxygen level dependent (BOLD) imaging were perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390516

    authors: Schmitz B,Bock C,Hoehn-Berlage M,Kerskens CM,Böttiger BW,Hossmann KA

    更新日期:1998-05-01 00:00:00

  • In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

    abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26190

    authors: Ganji SK,An Z,Tiwari V,McNeil S,Pinho MC,Pan E,Mickey BE,Maher EA,Choi C

    更新日期:2017-03-01 00:00:00

  • Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

    abstract::A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24137

    authors: Song T,Stainsby JA,Ho VB,Hood MN,Slavin GS

    更新日期:2012-03-01 00:00:00

  • Diffusion-weighted imaging of the human optic nerve: a new approach to evaluate optic neuritis in multiple sclerosis.

    abstract::The apparent diffusion coefficient (ADC) in the optic nerve was measured from diffusion-weighted magnetic resonance imaging using an intravoxel incoherent motion (IVIM) sequence. The subjects were seven normal volunteers and eight patients with multiple sclerosis (MS) with a total of four optic nerves with acute neuri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380317

    authors: Iwasawa T,Matoba H,Ogi A,Kurihara H,Saito K,Yoshida T,Matsubara S,Nozaki A

    更新日期:1997-09-01 00:00:00

  • Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

    abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26826

    authors: Deelchand DK,Auerbach EJ,Kobayashi N,Marjańska M

    更新日期:2018-03-01 00:00:00

  • Multispectral imaging with three-dimensional rosette trajectories.

    abstract::Two-dimensional intersecting k-space trajectories have previously been demonstrated to allow fast multispectral imaging. Repeated sampling of k-space points leads to destructive interference of the signal coming from the off-resonance spectral peaks; on-resonance data reconstruction yields images of the on-resonance p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21551

    authors: Bucholz EK,Song J,Johnson GA,Hancu I

    更新日期:2008-03-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • Arterial spin labeling perfusion fMRI with very low task frequency.

    abstract::Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10437

    authors: Wang J,Aguirre GK,Kimberg DY,Roc AC,Li L,Detre JA

    更新日期:2003-05-01 00:00:00

  • Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

    abstract::An implementation is reported of an imaging method to obtain MUltiple Resolutions along Phase-encode and Slice-select dimensions (MURPS), which enables dynamic imaging of focal changes using a graded, multiresolution approach. MURPS allows one to trade spatial resolution in part of the volume for improved temporal res...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1126

    authors: Panych LP,Zhao L,Jolesz FA,Mulkern RV

    更新日期:2001-06-01 00:00:00

  • Calculation of signal intensities in hybrid sequences for fast NMR imaging.

    abstract::A number of techniques that recently have been used for fast NMR-imaging are based on a hybrid sequence of echo planar imaging (EPI) and FLASH imaging: after each NMR excitation several k-space lines are measured. The complete k-space is covered by performance of several excitations. It has been observed that there is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340328

    authors: Deichmann R,Adolf H,Nöth U,Kuchenbrod E,Schwarzbauer C,Haase A

    更新日期:1995-09-01 00:00:00

  • Detection of myocardial infarction in the mini-pig using NMR imaging.

    abstract::Spin-echo images of 10 myocardial infarcts in nine mini-pigs were obtained at 30 h, 3 days, and approximately 10 days postinfarction. Infarcts were not detected at all at 30 h in five out of five cases examined. At 3 days postembolization (six cases) one infarct was certainly detected, whilst at 10 days (nine cases) a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050302

    authors: Checkley D,Loveday BE,Waterton JC,Zhu XP,Isherwood I

    更新日期:1987-09-01 00:00:00

  • Aortic 4D flow: quantification of signal-to-noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T.

    abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25317

    authors: Hess AT,Bissell MM,Ntusi NA,Lewis AJ,Tunnicliffe EM,Greiser A,Stalder AF,Francis JM,Myerson SG,Neubauer S,Robson MD

    更新日期:2015-05-01 00:00:00

  • The Rician distribution of noisy MRI data.

    abstract::The image intensity in magnetic resonance magnitude images in the presence of noise is shown to be governed by a Rician distribution. Low signal intensities (SNR < 2) are therefore biased due to the noise. It is shown how the underlying noise can be estimated from the images and a simple correction scheme is provided ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340618

    authors: Gudbjartsson H,Patz S

    更新日期:1995-12-01 00:00:00

  • MRI visualization of rodent liver structure and peritoneal adhesion with dialyzate enhancement.

    abstract::This study investigated the use of peritoneal dialysis fluid (dialyzate) as a MR contrast agent to visualize the liver structure and peritoneal adhesion in rats at 7 T. Intraperitoneal injection of dialyzate (approximately 0.1 ml/g) yielded excellent and consistent intraperitoneal enhancement that delineated the liver...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21506

    authors: Cheung JS,Guo H,Leung JC,Man K,Lai KN,Wu EX

    更新日期:2008-05-01 00:00:00

  • In vivo measurement of brain metabolites using two-dimensional double-quantum MR spectroscopy--exploration of GABA levels in a ketogenic diet.

    abstract::A localized proton 2D double-quantum (DQ) spin-echo spectroscopy technique was implemented on 1.5 T clinical MRI scanners for the detection of gamma-aminobutyrate (GABA) in the brain. The 2D approach facilitates separation of peaks overlapping with GABA in 1D DQ-filtered (DQF) spectra. This technique was applied to fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10429

    authors: Wang ZJ,Bergqvist C,Hunter JV,Jin D,Wang DJ,Wehrli S,Zimmerman RA

    更新日期:2003-04-01 00:00:00

  • Quantification of perfusion in murine myocardium: A retrospectively triggered T1 -based ASL method using model-based reconstruction.

    abstract:PURPOSE:A method for the quantification of perfusion in murine myocardium is demonstrated. The method allows for the reconstruction of perfusion maps on arbitrary time points in the heart cycle while addressing problems that arise due to the irregular heart beat of mice. METHODS:A flow-sensitive alternating inversion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25526

    authors: Gutjahr FT,Kampf T,Winter P,Meyer CB,Williams T,Jakob PM,Bauer WR,Ziener CH,Helluy X

    更新日期:2015-12-01 00:00:00

  • Gadodiamide T1 relaxivity in brain tissue in vivo is lower than in saline.

    abstract::In vivo measurements of gadodiamide (Gd-DTPA-BMA) T(1) relaxivity were performed at 4.7 T in injured and normal rat brains. Cerebral lesions were induced in nine rats by a localized freezing method. T(1) maps of the lesions were generated before and after injection of Gd-DTPA-BMA (0.1-0.6 mmol/kg). Samples of normal a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20336

    authors: Pickup S,Wood AK,Kundel HL

    更新日期:2005-01-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • Quantitative diffusion imaging in implanted human breast tumors.

    abstract::Quantitative diffusion measurements were performed in tumors arising from inoculation of nude mice with two human breast cancer cell lines (MCF7 and T47D) to evaluate the specificity of this technique for characterizing solid tumors. ADC maps were compared to histology and correlated well with gross tumor morphology. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370417

    authors: Maier CF,Paran Y,Bendel P,Rutt BK,Degani H

    更新日期:1997-04-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Quantification of the extraction fraction for gadopentetate across breast cancer capillaries.

    abstract::To quantify the extraction fraction, E, for gadopentetate across tumor capillaries, R3230 adenocarcinomas were implanted in the mammary fat pads of seven rats. The value of E was determined by using a two-compartment tissue model in which the endothelial transfer coefficient, K(PS) (ml x min(-1) x cc(-1) of tissue), w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400406

    authors: Daldrup HE,Shames DM,Husseini W,Wendland MF,Okuhata Y,Brasch RC

    更新日期:1998-10-01 00:00:00

  • An evaluation of the effect of fasting on the exercise-induced changes in pH and Pi/PCr from skeletal muscle.

    abstract::The changes in the response of skeletal muscle to maximal dynamic exercise were investigated in going from a fasted state to a refed state by means of 31P NMR spectroscopy. It was found that in the fasted state, exercise-induced changes in Pi/PCr and in pH were both inhibited, in comparison with those in the refed sta...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030616

    authors: Lunt JA,Allen PS,Brauer M,Swinamer D,Treiber EO,Belcastro A,Eccles R,King EG

    更新日期:1986-12-01 00:00:00

  • Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals.

    abstract:PURPOSE:To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component. METHODS:Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and addit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26819

    authors: Levine E,Stevens K,Beaulieu C,Hargreaves B

    更新日期:2018-03-01 00:00:00