Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

Abstract:

:An implementation is reported of an imaging method to obtain MUltiple Resolutions along Phase-encode and Slice-select dimensions (MURPS), which enables dynamic imaging of focal changes using a graded, multiresolution approach. MURPS allows one to trade spatial resolution in part of the volume for improved temporal resolution in dynamic imaging applications. A unique method of Hadamard slice encoding is used, enabling the varying of the phase encode and slice resolution while maintaining a constant effective TR throughout the entire 3-D volume. MURPS was implemented using a gradient-recalled echo sequence, and its utility was demonstrated for MR temperature monitoring. In this preliminary work, it has been shown that changes throughout a large volume can be effectively monitored in times that would normally only permit dynamic imaging in one or a very few slices.

journal_name

Magn Reson Med

authors

Panych LP,Zhao L,Jolesz FA,Mulkern RV

doi

10.1002/mrm.1126

subject

Has Abstract

pub_date

2001-06-01 00:00:00

pages

940-7

issue

6

eissn

0740-3194

issn

1522-2594

pii

10.1002/mrm.1126

journal_volume

45

pub_type

杂志文章
  • Phosphonate-modified GdDTPA complexes. I. NMRD study of the solution behavior of new tissue-specific contrast agents.

    abstract::NMRD profiles, the magnetic field dependence of the water proton longitudinal relaxation rates, have been acquired for two new diphosphonate-modified GdDTPA complexes currently under evaluation as relaxation agents for the MRI detection of soft-tissue calcifications. Fresh dilute solutions show profiles identical to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170118

    authors: Adzamli IK,Blau M

    更新日期:1991-01-01 00:00:00

  • Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

    abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26116

    authors: Poulsen C,Wakeman DG,Atefi SR,Luu P,Konyn A,Bonmassar G

    更新日期:2017-02-01 00:00:00

  • Multidimensionally encoded magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24443

    authors: Lin FH

    更新日期:2013-07-01 00:00:00

  • Combined functional and viability cardiac MR imaging in a single breathhold.

    abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21390

    authors: Ibrahim el-SH,Stuber M,Kraitchman DL,Weiss RG,Osman NF

    更新日期:2007-10-01 00:00:00

  • Radial single-shot STEAM MRI.

    abstract::Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21401

    authors: Block KT,Frahm J

    更新日期:2008-04-01 00:00:00

  • Hypercarbia-induced changes in cerebral blood volume in the cat: a 1H MRI and intravascular contrast agent study.

    abstract::Cerebral blood volume changes with arterial carbon dioxide were monitored by proton T1-weighted MR images following administration of the intravascular contrast agent Gd-DTPA labeled with human serum albumin. Without MR contrast, no significant image intensity changes were observed with PaCO2. Following contrast, regi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230104

    authors: Moseley ME,Chew WM,White DL,Kucharczyk J,Litt L,Derugin N,Dupon J,Brasch RC,Norman D

    更新日期:1992-01-01 00:00:00

  • Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion.

    abstract:PURPOSE:To evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. THEORY:The extended phase graph (EPG) algorithm, originally designed to model the effe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27058

    authors: He X,Wengler K,Schweitzer ME

    更新日期:2018-08-01 00:00:00

  • Ifosfamide pharmacokinetics and hepatobiliary uptake in vivo investigated using single- and double-resonance 31P MRS.

    abstract::MRS has considerable potential for the measurement of drug pharmacokinetics in vivo. In this study single- and double-resonance (31)P MRS was used to investigate the biodistribution, pharmacokinetics, and metabolism of ifosfamide following administration of 500 mg/kg ifosfamide in guinea pigs. (1)H-decoupling was foun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10540

    authors: Mancini L,Payne GS,Dzik-Jurasz AS,Leach MO

    更新日期:2003-08-01 00:00:00

  • Quantitative analysis of the z-spectrum using a numerically simulated look-up table: Application to the healthy human brain at 7T.

    abstract:PURPOSE:To develop a method that fits a multipool model to z-spectra acquired from non-steady state sequences, taking into account the effects of variations in T1 or B1 amplitude and the results estimating the parameters for a four-pool model to describe the z-spectrum from the healthy brain. METHODS:We compared measu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26459

    authors: Geades N,Hunt BAE,Shah SM,Peters A,Mougin OE,Gowland PA

    更新日期:2017-08-01 00:00:00

  • Impact of capped and uncapped abandoned leads on the heating of an MR-conditional pacemaker implant.

    abstract:PURPOSE:To assess the risk of radiofrequency (RF)-induced heating in patients with MR-conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant. METHODS:Four commercial pacemaker leads were placed beside a MR-conditional PM system, inside a human trunk simulator. The phantom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25106

    authors: Mattei E,Gentili G,Censi F,Triventi M,Calcagnini G

    更新日期:2015-01-01 00:00:00

  • Application of image registration to measurement of intervertebral rotation in the lumbar spine.

    abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10319

    authors: Rogers BP,Haughton VM,Arfanakis K,Meyerand ME

    更新日期:2002-12-01 00:00:00

  • Measuring extracellular volume fraction by MRI: First verification of values given by clinical sequences.

    abstract:PURPOSE:To verify MR measurements of myocardial extracellular volume fraction (ECV) based on clinically applicable T1-mapping sequences against ECV measurements by radioisotope tracer in pigs and to relate the results to those obtained in volunteers. METHODS:Between May 2016 and March 2017, 8 volunteers (25 ± 4 years,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27938

    authors: Nordlund D,Xanthis C,Bidhult S,Jablonowski R,Kanski M,Kopic S,Carlsson M,Engblom H,Aletras AH,Arheden H

    更新日期:2020-02-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • In vivo measurement of brain metabolites using two-dimensional double-quantum MR spectroscopy--exploration of GABA levels in a ketogenic diet.

    abstract::A localized proton 2D double-quantum (DQ) spin-echo spectroscopy technique was implemented on 1.5 T clinical MRI scanners for the detection of gamma-aminobutyrate (GABA) in the brain. The 2D approach facilitates separation of peaks overlapping with GABA in 1D DQ-filtered (DQF) spectra. This technique was applied to fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10429

    authors: Wang ZJ,Bergqvist C,Hunter JV,Jin D,Wang DJ,Wehrli S,Zimmerman RA

    更新日期:2003-04-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • High-resolution 1H NMR spectroscopy in the diagnosis of breast cancer.

    abstract::Surgical specimens from 22 patients with infiltrating ductal carcinoma of the breast were analyzed by high-resolution 1H NMR spectroscopy at 80 and 300 MHz. Results were compared with those obtained from 9 benign (proliferative dysplasia without atypia) breast samples. NMR spectra at 80 MHz showed well-resolved water ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080407

    authors: Bradamante S,Barchiesi E,Pilotti S,Borasi G

    更新日期:1988-12-01 00:00:00

  • 1H NMR relaxation measurements of human tissues in situ by spatially resolved spectroscopy.

    abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040504

    authors: Luyten PR,Anderson CM,den Hollander JA

    更新日期:1987-05-01 00:00:00

  • Novel pH-sensitive paramagnetic liposomes with improved MR properties.

    abstract::The use of paramagnetic pH-sensitive liposomes was recently suggested as a new approach for monitoring pathologic changes in pH by MRI. Such liposomes must be stable in blood and selectively release the encapsulated paramagnetic agent when exposed to lower pH in the target tissue. In the present study, different lipos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20009

    authors: Løkling KE,Skurtveit R,Bjørnerud A,Fossheim SL

    更新日期:2004-04-01 00:00:00

  • B factor dependence of the temporal characteristics of brain activation using dynamic apparent diffusion coefficient contrast.

    abstract::Functional MRI studies to date have been generally performed using the blood oxygenation level dependent (BOLD) contrast mechanism. Recently, it has been proposed that dynamic change in the apparent diffusion coefficient (ADC), measured using intravoxel incoherent motion (IVIM) weighting, can be used as a robust funct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20293

    authors: Harshbarger TB,Song AW

    更新日期:2004-12-01 00:00:00

  • Detection of neural activity in functional MRI using canonical correlation analysis.

    abstract::A novel method for detecting neural activity in functional magnetic resonance imaging (fMRI) data is introduced. It is based on canonical correlation analysis (CCA), which is a multivariate extension of the univariate correlation analysis widely used in fMRI. To detect homogeneous regions of activity, the method combi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200102)45:2<323::aid-mrm1041>3.0

    authors: Friman O,Cedefamn J,Lundberg P,Borga M,Knutsson H

    更新日期:2001-02-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • Contributions of chemical exchange to T1ρ dispersion in a tissue model.

    abstract::Variations in T(1ρ) with locking-field strength (T(1ρ) dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross-linked polyacrylamide gels. These gels were varied in relative compositi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22947

    authors: Cobb JG,Xie J,Gore JC

    更新日期:2011-12-01 00:00:00

  • A multicontrast imaging method using steady-state free precession with alternating RF flip angles.

    abstract:PURPOSE:To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed. METHODS:The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence ha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27342

    authors: Kim J,Seo H,So S,Park H

    更新日期:2018-10-01 00:00:00

  • Online correction of respiratory-induced field disturbances for continuous MR-thermometry in the breast.

    abstract::MR-thermometry allows monitoring of the local temperature evolution during minimally invasive interventional therapies. However, for the particular case of MR-thermometry in the human breast, magnetic field variations induced by the respiratory cycle lead to phase fluctuations requiring a suitable correction strategy ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21954

    authors: Hey S,Maclair G,de Senneville BD,Lepetit-Coiffe M,Berber Y,Köhler MO,Quesson B,Moonen CT,Ries M

    更新日期:2009-06-01 00:00:00

  • Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

    abstract:PURPOSE:Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY:The method, T2-Relaxation-U...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24750

    authors: Krishnamurthy LC,Liu P,Ge Y,Lu H

    更新日期:2014-03-01 00:00:00

  • Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    abstract::The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10604

    authors: de Vocht F,van-Wendel-de-Joode B,Engels H,Kromhout H

    更新日期:2003-10-01 00:00:00

  • Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR.

    abstract::A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21194

    authors: Devasahayam N,Subramanian S,Murugesan R,Hyodo F,Matsumoto K,Mitchell JB,Krishna MC

    更新日期:2007-04-01 00:00:00

  • Apparent changes of appearance of inversion-recovery images.

    abstract::This note considers the anomolous contrast in inversion recovery images produced by NMR scanners if a map of [My] is reconstructed, rather than a map of My'. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020110

    authors: Young IR,Bailes DR,Bydder GM

    更新日期:1985-02-01 00:00:00

  • Improved steering of the RF field of traveling wave MR with a multimode, coaxial waveguide.

    abstract:PURPOSE:Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24807

    authors: Andreychenko A,Kroeze H,Boer VO,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-04-01 00:00:00