Improved MUSSELS reconstruction for high-resolution multi-shot diffusion weighted imaging.

Abstract:

PURPOSE:MUSSELS is a one-step iterative reconstruction method for multishot diffusion weighted (msDW) imaging. The current work presents an efficient implementation, termed IRLS MUSSELS, that enables faster reconstruction to enhance its utility for high-resolution diffusion MRI studies. METHODS:The recently proposed MUSSELS reconstruction belongs to a new class of parallel imaging-based methods that recover artifact-free DWIs from msDW data without needing phase compensation. The reconstruction is achieved via structured low-rank matrix completion algorithms, which are computationally demanding due to the large size of the Hankel matrices and their associated computations involving singular value decompositions. Because of this, computational demands of the MUSSELS reconstruction scales as the matrix size and the number of shots increases, which hinders its practical utility for high-resolution applications. In this work, we derive a computationally efficient MUSSELS formulation by modifying the iterative reweighted least squares (IRLS) method that were proposed earlier to solve such problems. Using whole-brain in vivo data, we show the utility of the IRLS MUSSELS for routine high-resolution studies with reduced computational burden. RESULTS:IRLS MUSSELS provides about five times faster reconstruction for matrix sizes 192 × 192 and 256 × 256 compared to the earlier MUSSELS implementation. The widely employed conjugate symmetry priors can also be incorporated into IRLS MUSSELS to reduce blurring of the partial Fourier acquisitions, without incurring much computational burden. CONCLUSIONS:The proposed method is observed to be computationally efficient to enable routine high-resolution studies. The computational complexity matches the traditional msDWI reconstruction methods and provides improved reconstruction results with the additional constraints.

journal_name

Magn Reson Med

authors

Mani M,Aggarwal HK,Magnotta V,Jacob M

doi

10.1002/mrm.28090

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

2253-2263

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

83

pub_type

杂志文章
  • Reconstruction by calibration over tensors for multi-coil multi-acquisition balanced SSFP imaging.

    abstract:PURPOSE:To develop a rapid imaging framework for balanced steady-state free precession (bSSFP) that jointly reconstructs undersampled data (by a factor of R) across multiple coils (D) and multiple acquisitions (N). To devise a multi-acquisition coil compression technique for improved computational efficiency. METHODS:...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26902

    authors: Biyik E,Ilicak E,Çukur T

    更新日期:2018-05-01 00:00:00

  • On multiple alternating steady states induced by periodic spin phase perturbation waveforms.

    abstract::Direct measurement of neural currents by means of MRI can potentially open a high temporal resolution (10-100 ms) window applicable for monitoring dynamics of neuronal activity without loss of the high spatial resolution afforded by MRI. Previously, we have shown that the alternating balanced steady state imaging affo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23105

    authors: Buračas GT,Jung Y,Lee J,Buxton RB,Wong EC,Liu TT

    更新日期:2012-05-01 00:00:00

  • Proton exchange rates from amino acid side chains--implications for image contrast.

    abstract::The proton exchange rates between water and the hydroxyl protons of threonine, serine, tyrosine, the amino protons of lysine, and the guanidinium protons of arginine were measured in the pH range 0.5 to 8.5 and for the temperatures 4 degrees C, 10 degrees C, 20 degrees C, 30 degrees C, and 36 degrees C. The intrinsic ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350106

    authors: Liepinsh E,Otting G

    更新日期:1996-01-01 00:00:00

  • Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation.

    abstract::In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd(3+) ions further increases the achievable solid-state polarization. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24207

    authors: Gordon JW,Fain SB,Rowland IJ

    更新日期:2012-12-01 00:00:00

  • A torque balance measurement of anisotropy of the magnetic susceptibility in white matter.

    abstract:PURPOSE:Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment-specific information. This study provides an independent confir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25524

    authors: van Gelderen P,Mandelkow H,de Zwart JA,Duyn JH

    更新日期:2015-11-01 00:00:00

  • Dynamic glucose-enhanced (DGE) MRI in the human brain at 7 T with reduced motion-induced artifacts based on quantitative R1ρ mapping.

    abstract:PURPOSE:Dynamic glucose-enhanced (DGE)-MRI based on chemical exchange-sensitive MRI, that is, glucoCEST and gluco-chemical exchange-sensitive spin-lock (glucoCESL), is intrinsically prone to motion-induced artifacts because the final DGE contrast relies on the difference of images, which were acquired with a time gap o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28112

    authors: Boyd PS,Breitling J,Zimmermann F,Korzowski A,Zaiss M,Schuenke P,Weinfurtner N,Schlemmer HP,Ladd ME,Bachert P,Paech D,Goerke S

    更新日期:2020-07-01 00:00:00

  • EPR spectrometer for clinical applications.

    abstract::This article describes an EPR spectrometer specifically designed and constructed for EPR spectroscopy in humans. The spectrometer is based on a permanent magnet, suitable for measurements at 1200 MHz. The magnet has a full 50 cm gap between the poles, which facilitates accurate and comfortable placement of the subject...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20689

    authors: Salikhov I,Walczak T,Lesniewski P,Khan N,Iwasaki A,Comi R,Buckey J,Swartz HM

    更新日期:2005-11-01 00:00:00

  • Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI.

    abstract::Myocardial blood flow varies during the cardiac cycle in response to pulsatile changes in epicardial circulation and cyclical variation in myocardial tension. First-pass assessment of myocardial perfusion by dynamic contrast-enhanced MRI is one of the most challenging applications of MRI because of the spatial and tem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22538

    authors: Radjenovic A,Biglands JD,Larghat A,Ridgway JP,Ball SG,Greenwood JP,Jerosch-Herold M,Plein S

    更新日期:2010-12-01 00:00:00

  • A versatile multinuclear probe designed for in vivo NMR spectroscopy: applications to subcutaneous human tumors in mice.

    abstract::We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060102

    authors: Lyon RC,Tschudin RG,Daly PF,Cohen JS

    更新日期:1988-01-01 00:00:00

  • Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

    abstract::A novel radio-frequency (RF) pulse design algorithm is presented that generates fast slice-selective excitation pulses that mitigate B+1 inhomogeneity present in the human brain at high field. The method is provided an estimate of the B+1 field in an axial slice of the brain and then optimizes the placement of sinc-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21585

    authors: Zelinski AC,Wald LL,Setsompop K,Alagappan V,Gagoski BA,Goyal VK,Adalsteinsson E

    更新日期:2008-06-01 00:00:00

  • Proton NMR spectroscopy of solvent-saturable resonances: a new approach to study pH effects in situ.

    abstract::It is shown that the effect of pH changes can be measured in proton NMR spectra through the pH sensitivity of the signal intensities of metabolite protons exchanging with water. To observe this phenomenon, pulse sequences must be used that can sensitively observe these exchangeable protons under physiological conditio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400105

    authors: Mori S,Eleff SM,Pilatus U,Mori N,van Zijl PC

    更新日期:1998-07-01 00:00:00

  • Time-resolved flow measurement in the isolated rat heart: characterization of left coronary artery stenosis.

    abstract::The investigation of flow behavior in coronary arteries is of great importance for an understanding of heart failure and heart regulation mechanisms. The purpose of the present study was to demonstrate that flow velocity can be quantified in the coronary arteries of the isolated rat heart with high-resolution phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10563

    authors: Köhler S,Hiller KH,Jakob PM,Bauer WR,Haase A

    更新日期:2003-09-01 00:00:00

  • Localized 7Li MR spectroscopy and spin relaxation in rat brain in vivo.

    abstract::Localized 7Li MR point-resolved spectroscopy (PRESS) was developed as a technique to measure lithium (Li) concentration in rat brain in vivo. Localized 7Li spectra could be obtained at 4.7 T in a 0.7-ml voxel in rat brain over the entire therapeutic range of serum Li for humans. Localized 7Li spin-lattice (T1) and spi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20112

    authors: Komoroski RA,Pearce JM

    更新日期:2004-07-01 00:00:00

  • Driving mutually coupled gradient array coils in magnetic resonance imaging.

    abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27768

    authors: Ertan K,Taraghinia S,Atalar E

    更新日期:2019-09-01 00:00:00

  • Rapid in vivo musculoskeletal MR with parallel imaging at 7T.

    abstract::The purpose of this work was to implement autocalibrating GRAPPA-based parallel imaging (PI) for in vivo high-resolution (HR) MRI of cartilage and trabecular bone micro-architecture at 7T and to evaluate its performance based on comparison of MR-derived morphology metrics between accelerated and conventional images an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21455

    authors: Banerjee S,Krug R,Carballido-Gamio J,Kelley DA,Xu D,Vigneron DB,Majumdar S

    更新日期:2008-03-01 00:00:00

  • Changes in T2*-weighted images during hyperoxia differentiate tumors from normal tissue.

    abstract::Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recyc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330306

    authors: Kuperman VYu,River JN,Lewis MZ,Lubich LM,Karczmar GS

    更新日期:1995-03-01 00:00:00

  • Group sparse reconstruction using intensity-based clustering.

    abstract::Compressed sensing has been of great interest to speed up the acquisition of MR images. The k-t group sparse (k-t GS) method has recently been introduced for dynamic MR images to exploit not just the sparsity, as in compressed sensing, but also the spatial group structure in the sparse representation. k-t GS achieves ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24333

    authors: Prieto C,Usman M,Wild JM,Kozerke S,Batchelor PG,Schaeffter T

    更新日期:2013-04-01 00:00:00

  • Potassium transport in Langendorff-perfused mouse hearts assessed by 87Rb NMR spectroscopy.

    abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20450

    authors: Jilkina O,Xiang B,Kuzio B,Rendell J,Kupriyanov VV

    更新日期:2005-05-01 00:00:00

  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • Perturbation of longitudinal relaxation rate in rotating frame (PLRF) analysis for quantification of chemical exchange saturation transfer signal in a transient state.

    abstract:PURPOSE:To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. METHODS:The difference in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26559

    authors: Wang Y,Zhang Y,Zhao X,Wu B,Gao JH

    更新日期:2017-11-01 00:00:00

  • Infimal convolution of total generalized variation functionals for dynamic MRI.

    abstract:PURPOSE:To accelerate dynamic MR applications using infimal convolution of total generalized variation functionals (ICTGV) as spatio-temporal regularization for image reconstruction. THEORY AND METHODS:ICTGV comprises a new image prior tailored to dynamic data that achieves regularization via optimal local balancing b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26352

    authors: Schloegl M,Holler M,Schwarzl A,Bredies K,Stollberger R

    更新日期:2017-07-01 00:00:00

  • Water suppression with B0 field gradient homospoil pulses in high-resolution NMR spectroscopy.

    abstract::The combination of a frequency nonselective excitation suppression method (1331 sequence) with selective excitation followed by gradient-induced dephasing of water transverse magnetization yielded suppression ratios of greater than 10,000:1. The need for gradient preemphasis and correction of B0 field shifts is discus...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090114

    authors: Brereton IM,Field J,Moxon LN,Irving MG,Doddrell DM

    更新日期:1989-01-01 00:00:00

  • Spectroscopic imaging of glutamate C4 turnover in human brain.

    abstract::One-dimensional spectroscopic imaging of (13)C-4-glutamate turnover is performed in the human brain with a 6 cc nominal voxel resolution at 4T. Data were acquired with an indirect detection approach using a short spin echo single quantum (1)H-(13)C heteronuclear editing method and a 7 cm surface coil with quadrature (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200011)44:5<673::aid-mrm3>3.0.co

    authors: Pan JW,Stein DT,Telang F,Lee JH,Shen J,Brown P,Cline G,Mason GF,Shulman GI,Rothman DL,Hetherington HP

    更新日期:2000-11-01 00:00:00

  • 1H and (31)P magnetization transfer studies of hindleg muscle in wild-type and creatine kinase-deficient mice.

    abstract::The authors addressed the hypothesis that interactions with creatine kinase (CK) play a role in the off-resonance magnetization transfer (MT) effect of creatine in skeletal muscle. Toward that aim, (1)H MT studies were done on hindleg muscle in wild-type mice and in transgenic mice, lacking cytoplasmic CK and/or mitoc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<657::aid-mrm7>

    authors: Kruiskamp MJ,van Vliet G,Nicolay K

    更新日期:2000-05-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging for in vivo assessment of damage and functional improvement following spinal cord injury in mice.

    abstract::In past decades, much effort has been invested in developing therapies for spinal injuries. Lack of standardization of clinical read-out measures, however, makes direct comparison of experimental therapies difficult. Damage and therapeutic effects in vivo are routinely evaluated using rather subjective behavioral test...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20888

    authors: Stieltjes B,Klussmann S,Bock M,Umathum R,Mangalathu J,Letellier E,Rittgen W,Edler L,Krammer PH,Kauczor HU,Martin-Villalba A,Essig M

    更新日期:2006-05-01 00:00:00

  • Impact of signal-to-noise on functional MRI.

    abstract::Functional magnetic resonance imaging (fMRI) has recently been adopted as an investigational tool in the field of neuroscience. The signal changes induced by brain activations are small ( approximately 1-2%) at 1.5T. Therefore, the signal-to-noise ratio (SNR) of the time series used to calculate the functional maps is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200012)44:6<925::aid-mrm14>3.0.c

    authors: Parrish TB,Gitelman DR,LaBar KS,Mesulam MM

    更新日期:2000-12-01 00:00:00

  • Multispectral imaging with three-dimensional rosette trajectories.

    abstract::Two-dimensional intersecting k-space trajectories have previously been demonstrated to allow fast multispectral imaging. Repeated sampling of k-space points leads to destructive interference of the signal coming from the off-resonance spectral peaks; on-resonance data reconstruction yields images of the on-resonance p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21551

    authors: Bucholz EK,Song J,Johnson GA,Hancu I

    更新日期:2008-03-01 00:00:00

  • Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.

    abstract::Chemical exchange saturation transfer (CEST) and spin-locking (SL) experiments were both able to probe the exchange process between protons of nonequivalent chemical environments. To compare the characteristics of the CEST and SL approaches in the study of chemical exchange effects, we performed CEST and SL experiment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22721

    authors: Jin T,Autio J,Obata T,Kim SG

    更新日期:2011-05-01 00:00:00

  • Quantification of fluid changes in rat leg joints with adjuvant arthritis by a one-dimensional magnetic resonance imaging experiment.

    abstract::A simple and reliable method for quantifying the fluid content and characterizing the tissue T2 relaxation properties of animal extremities has been devised. This one-dimensional magnetic resonance imaging experiment, applied to the adjuvant arthritis model in rats, provides a useful, noninvasive monitor of the course...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150208

    authors: Borah B,Szeverenyi NM

    更新日期:1990-08-01 00:00:00

  • Brain water diffusion in normal and creatine-supplemented rats during transient global ischemia.

    abstract::Brain water diffusion in response to transient global ischemia (12 min), reperfusion (60 min), and cardiac arrest was monitored by localized proton magnetic resonance spectroscopy. The trace of the apparent diffusion coefficient tensor (ADC(Av)) was determined at high temporal resolution (10 sec) to assess the putativ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<798::aid-mrm23

    authors: Wick M,Fujimori H,Michaelis T,Frahm J

    更新日期:1999-10-01 00:00:00