A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

Abstract:

PURPOSE:This work describes the construction and evaluation of a bilateral 32-channel receive array for breast imaging at 7T. METHODS:The receive array consisted of 32 receive coils, placed on two 3D-printed hemispherical formers. Each side of the receive array consisted of 16 receive loops, each loop having a corresponding detachable board with match/tune capacitors, active detuning circuitry, and a balun. Coil performance was evaluated on homogeneous canola oil phantoms using a Philips Achieva 7T system. Array coil performance was compared with a bilateral forced current excitation volume coil in transmit/receive mode and with a previously reported 16-channel unilateral coil with a similar design. RESULTS:The 32-channel array had an increase in average SNR throughout both phantoms by a factor of five as compared with the volume coil, with SNR increases up to 10 times along the periphery and three times in the center. Noise measurements showed low interelement noise correlation (average: 5.4%; maximum: 16.8%). Geometry factor maps were acquired for various acceleration factors and showed mean geometry factors <1.2, for combined acceleration factors of up to six. CONCLUSIONS:The improvements achieved demonstrate the clear potential for use in dynamic contrast-enhanced or diffusion-weighted MR studies, while maintaining diagnostically relevant spatial and temporal resolutions.

journal_name

Magn Reson Med

authors

Del Bosque R,Cui J,Ogier S,Cheshkov S,Dimitrov IE,Malloy C,Wright SM,McDougall M

doi

10.1002/mrm.28425

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

551-559

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

85

pub_type

杂志文章
  • Respiration based steering for high intensity focused ultrasound liver ablation.

    abstract:PURPOSE:Respiratory motion makes hepatic ablation using high intensity focused ultrasound (HIFO) challenging. Previous HIFU liver treatment had required apnea induced during general anesthesia. We describe and test a system that allows treatment of the liver in the presence of breathing motion. METHODS:Mapping a signa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24695

    authors: Holbrook AB,Ghanouni P,Santos JM,Dumoulin C,Medan Y,Pauly KB

    更新日期:2014-02-01 00:00:00

  • Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T.

    abstract::The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>

    authors: Calamante F,Lythgoe MF,Pell GS,Thomas DL,King MD,Busza AL,Sotak CH,Williams SR,Ordidge RJ,Gadian DG

    更新日期:1999-03-01 00:00:00

  • MRI of [2-13 C]Lactate without J-coupling artifacts.

    abstract:PURPOSE:Imaging of [2-13 C]lactate, a metabolic product of [2-13 C]pyruvate, is over considerable interest in hyperpolarized 13 C studies. However, artifact-free imaging of a J-coupled nuclear spin species can be challenging due to the peak-splitting induced by the spin-spin interactions. In this work, two new techniqu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28532

    authors: Datta K,Spielman D

    更新日期:2021-03-01 00:00:00

  • S5FP: spectrally selective suppression with steady state free precession.

    abstract::A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20633

    authors: Derbyshire JA,Herzka DA,McVeigh ER

    更新日期:2005-10-01 00:00:00

  • In vitro study to simulate the intracardiac magnetohydrodynamic effect.

    abstract:PURPOSE:Blood flow causes induced voltages via the magnetohydrodynamic (MHD) effect distorting electrograms (EGMs) made during magnetic resonance imaging. To investigate the MHD effect in this context MHD voltages occurring inside the human heart were simulated in an in vitro model system inside a 1.5 T MR system. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25456

    authors: Buchenberg WB,Mader W,Hoppe G,Lorenz R,Menza M,Büchert M,Timmer J,Jung B

    更新日期:2015-09-01 00:00:00

  • Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI.

    abstract::Patient motion and image distortion induced by eddy currents cause artifacts in maps of diffusion parameters computed from diffusion-weighted (DW) images. A novel and comprehensive approach to correct for spatial misalignment of DW imaging (DWI) volumes acquired with different strengths and orientations of the diffusi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10677

    authors: Rohde GK,Barnett AS,Basser PJ,Marenco S,Pierpaoli C

    更新日期:2004-01-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • Fe(III) distribution varies substantially within and between atherosclerotic plaques.

    abstract:PURPOSE:Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24687

    authors: Gustafsson H,Hallbeck M,Norell M,Lindgren M,Engström M,Rosén A,Zachrisson H

    更新日期:2014-02-01 00:00:00

  • Super-resolution for upper abdominal MRI: Acquisition and post-processing protocol optimization using brain MRI control data and expert reader validation.

    abstract:PURPOSE:Magnetic resonance (MR) cholangiopancreatography (MRCP) is an established specialist method for imaging the upper abdomen and biliary/pancreatic ducts. Due to limitations of either MR image contrast or low through-plane resolution, patients may require further evaluation with contrast-enhanced computed tomograp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27852

    authors: Ebner M,Patel PA,Atkinson D,Caselton L,Firmin L,Amin Z,Bainbridge A,De Coppi P,Taylor SA,Ourselin S,Chouhan MD,Vercauteren T

    更新日期:2019-11-01 00:00:00

  • High-resolution contrast-enhanced MRI of atherosclerosis with digital cardiac and respiratory gating in mice.

    abstract::Atherosclerosis initially develops predominantly at the aortic root and carotid origin, where effective visualization in mice requires efficient cardiac and respiratory gating. The present study sought to first compare the high-resolution MRI gating performance of two digital gating strategies using: 1) separate cardi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21308

    authors: Alsaid H,Sabbah M,Bendahmane Z,Fokapu O,Felblinger J,Desbleds-Mansard C,Corot C,Briguet A,Crémillieux Y,Canet-Soulas E

    更新日期:2007-12-01 00:00:00

  • Vascular transit times in calcarine cortex: kinetic analysis of R2* changes observed using localized 1H spectroscopy.

    abstract::A kinetic analysis of water signal intensity changes measured in human visual cortex by PRESS localized 1H spectroscopy at 500 ms resolution with light-emitting diode (LED) goggle stimulation was used to determine vascular transit times for transitions between rest and activation. Monoexponential curve fitting was use...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340308

    authors: Detre JA,Wang Z,Stecker MM,Zimmerman RA

    更新日期:1995-09-01 00:00:00

  • Ramped hybrid encoding for improved ultrashort echo time imaging.

    abstract:PURPOSE:We propose a new acquisition to minimize the per-excitation encoding duration and improve the imaging capability for short T2 * species. METHODS:In the proposed ramped hybrid encoding (RHE) technique, gradients are applied before the radiofrequency (RF) pulse as in pointwise encoding time reduction with radial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25977

    authors: Jang H,Wiens CN,McMillan AB

    更新日期:2016-09-01 00:00:00

  • Phosphonate-modified GdDTPA complexes. I. NMRD study of the solution behavior of new tissue-specific contrast agents.

    abstract::NMRD profiles, the magnetic field dependence of the water proton longitudinal relaxation rates, have been acquired for two new diphosphonate-modified GdDTPA complexes currently under evaluation as relaxation agents for the MRI detection of soft-tissue calcifications. Fresh dilute solutions show profiles identical to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170118

    authors: Adzamli IK,Blau M

    更新日期:1991-01-01 00:00:00

  • In vivo gallbladder bile diffusion coefficient measurement by diffusion-weighted echo planar imaging in hamster fed normal and lithogenic diets.

    abstract::It is shown that in vivo measurement of bile water apparent diffusion coefficient (ADC) by diffusion-weighted echo-planar imaging (EPI) in hamster gallbladder is possible providing motion artifact-free ADC values. These ADC values are used to estimate bile viscosity variation induced by normal diets, cholesterol galls...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200006)43:6<854::aid-mrm11>3.0.c

    authors: Tiffon B,Parquet M,Dubrac S,Lutton C,Volk A

    更新日期:2000-06-01 00:00:00

  • Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

    abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26116

    authors: Poulsen C,Wakeman DG,Atefi SR,Luu P,Konyn A,Bonmassar G

    更新日期:2017-02-01 00:00:00

  • A one-step biomarker quantification methodology for DCE-MRI of adnexal masses: Capturing kinetic pattern from early to late enhancement.

    abstract:PURPOSE:To develop a one-step quantification approach that accounts for joint preprocessing and quantification of whole-range kinetics (early and late-phase washout) of dynamic contrast-enhanced (DCE) MRI of indeterminate adnexal masses. METHODS:Preoperative DCE-MRI of 43 (24 benign, 19 malignant) sonographically inde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26743

    authors: Fathi Kazerooni A,Nabil M,Haghighat Khah H,Parviz S,Gity M,Saligheh Rad H

    更新日期:2018-02-01 00:00:00

  • Counter rotating current local coils for high-resolution magnetic resonance imaging.

    abstract::A type of local coil (or surface coil) for magnetic resonance imaging and spectroscopy is described in which two circular loops of the same diameter are disposed axially with respect to each other and in which counter rotating currents (CRC) are supported in the two loops. This type of coil has been used for localized...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030412

    authors: Froncisz W,Jesmanowicz A,Kneeland JB,Hyde JS

    更新日期:1986-08-01 00:00:00

  • Perfusion MRI of U87 brain tumors in a mouse model.

    abstract::Continuous arterial spin labeling (CASL) was used to obtain an index of cerebral blood flow (ICBF) in the normal mouse brain and in an orthotopic mouse model of human U87 high-grade glioma at 8.5 T. Under the assumption of a constant tissue:blood partition coefficient for water in different tissues, the mean ICBF (n =...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20029

    authors: Sun Y,Schmidt NO,Schmidt K,Doshi S,Rubin JB,Mulkern RV,Carroll R,Ziu M,Erkmen K,Poussaint TY,Black P,Albert M,Burstein D,Kieran MW

    更新日期:2004-05-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

    abstract:PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27439

    authors: Goldenberg JM,Cárdenas-Rodríguez J,Pagel MD

    更新日期:2019-01-01 00:00:00

  • Present clinical status of magnetic resonance imaging.

    abstract::Magnetic resonance imaging has achieved clinical importance and has become the primary tool in the investigation of head, spinal cord, pelvis, cancellous bone, pericardium (with gating), gallbladder, lymph node masses, and very soon, in the evaluation of joints. In many areas, particularly with respiratory and ECG gat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910020402

    authors: Margulis AR,Fisher MR

    更新日期:1985-08-01 00:00:00

  • Dynamic activity-induced manganese-dependent contrast magnetic resonance imaging (DAIM MRI).

    abstract::Activity-induced manganese-dependent contrast (AIM) MRI is a hemodynamic-independent functional MRI method that used manganese ion as an MR-detectable contrast agent. In AIM, MnCl(2) is infused intra-arterially after the blood-brain barrier (BBB) is opened with a hyperosmolar agent. Upon functional stimulation of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10320

    authors: Aoki I,Tanaka C,Takegami T,Ebisu T,Umeda M,Fukunaga M,Fukuda K,Silva AC,Koretsky AP,Naruse S

    更新日期:2002-12-01 00:00:00

  • Direct saturation-corrected chemical exchange saturation transfer MRI of glioma: Simplified decoupling of amide proton transfer and nuclear overhauser effect contrasts.

    abstract:PURPOSE:Chemical exchange saturation transfer (CEST) MRI has shown promise in tissue characterization in diseases like stroke and tumor. However, in vivo CEST imaging such as amide proton transfer (APT) MRI is challenging because of concomitant factors such as direct water saturation, macromolecular magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26959

    authors: Yuwen Zhou I,Wang E,Cheung JS,Lu D,Ji Y,Zhang X,Fulci G,Sun PZ

    更新日期:2017-12-01 00:00:00

  • Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T.

    abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25262

    authors: Tao Y,Hess AT,Keith GA,Rodgers CT,Liu A,Francis JM,Neubauer S,Robson MD

    更新日期:2015-04-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • Investigation of resolution effects using a specialized diffusion tensor phantom.

    abstract:PURPOSE:The clinical potential of the diffusion imaging-based analysis of fine brain structures such as fornix or cingulum is high due to the central role of these structures in psychiatric diseases. However, the quantification of diffusion parameters in fine structures is especially prone to partial volume effects (PV...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24774

    authors: Bach M,Fritzsche KH,Stieltjes B,Laun FB

    更新日期:2014-03-01 00:00:00

  • Determination of extracellular/intracellular fluid ratios from magnetic resonance images: accuracy, feasibility, and implementation.

    abstract::This study determines the accuracy and feasibility of using localized spin-lattice (T1) relaxation time measurements from magnetic resonance (MR) images to follow changes in extracellular/intracellular fluid ratios in defined subvolumes of living tissue. A red blood cell suspension was used as a test system and a simp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150107

    authors: Martin MA,Tatton WG,Lemaire C,Armstrong RL

    更新日期:1990-07-01 00:00:00

  • SLIP, a lipid suppression technique to improve image contrast in inflow angiography.

    abstract::In rapidly acquired gradient echo images, lipid regions usually appear as areas of high signal intensity. In 2D inflow angiograms processed by the maximum intensity projection algorithm, this high lipid signal may prevent angiographic visualization of some blood vessels. We present a new approach to suppress the lipid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210110

    authors: Doyle M,Matsuda T,Pohost GM

    更新日期:1991-09-01 00:00:00

  • Spatial-frequency-tuned markers and adaptive correction for rotational motion.

    abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330511

    authors: Korin HW,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1995-05-01 00:00:00

  • Spectroscopic imaging of glutamate C4 turnover in human brain.

    abstract::One-dimensional spectroscopic imaging of (13)C-4-glutamate turnover is performed in the human brain with a 6 cc nominal voxel resolution at 4T. Data were acquired with an indirect detection approach using a short spin echo single quantum (1)H-(13)C heteronuclear editing method and a 7 cm surface coil with quadrature (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200011)44:5<673::aid-mrm3>3.0.co

    authors: Pan JW,Stein DT,Telang F,Lee JH,Shen J,Brown P,Cline G,Mason GF,Shulman GI,Rothman DL,Hetherington HP

    更新日期:2000-11-01 00:00:00