Present clinical status of magnetic resonance imaging.

Abstract:

:Magnetic resonance imaging has achieved clinical importance and has become the primary tool in the investigation of head, spinal cord, pelvis, cancellous bone, pericardium (with gating), gallbladder, lymph node masses, and very soon, in the evaluation of joints. In many areas, particularly with respiratory and ECG gating, this method promises to replace all other imaging modalities with the precision of information obtained. Today the exceptions are the alimentary tube and its mesentery, between the esophagus and rectum, and the peripheral lung.

journal_name

Magn Reson Med

authors

Margulis AR,Fisher MR

doi

10.1002/mrm.1910020402

subject

Has Abstract

pub_date

1985-08-01 00:00:00

pages

309-27

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

2

pub_type

杂志文章,评审
  • Application of image registration to measurement of intervertebral rotation in the lumbar spine.

    abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10319

    authors: Rogers BP,Haughton VM,Arfanakis K,Meyerand ME

    更新日期:2002-12-01 00:00:00

  • Improved steering of the RF field of traveling wave MR with a multimode, coaxial waveguide.

    abstract:PURPOSE:Magnetic resonance imaging of humans at high magnetic field strengths is strongly influenced by the interference of the radiofrequency (RF) electromagnetic field and the body. To minimize this effect, multiple RF sources could be used. A novel setup (called multimode, coaxial waveguide) is proposed that facilit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24807

    authors: Andreychenko A,Kroeze H,Boer VO,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-04-01 00:00:00

  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging.

    abstract:PURPOSE:To assess volumetric proton MR spectroscopic imaging (MRSI) of the human brain on multivendor MRI instruments. METHODS:Echo-planar spectroscopic imaging was developed on instruments from three manufacturers, with matched specifications and acquisition protocols that accounted for differences in sampling perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25510

    authors: Sabati M,Sheriff S,Gu M,Wei J,Zhu H,Barker PB,Spielman DM,Alger JR,Maudsley AA

    更新日期:2015-11-01 00:00:00

  • Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.

    abstract::A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arteria...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10733

    authors: Hernandez-Garcia L,Lee GR,Vazquez AL,Noll DC

    更新日期:2004-03-01 00:00:00

  • Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

    abstract:PURPOSE:To develop a three-dimensional, free-breathing, late gadolinium enhancement (3D FB-LGE) cardiovascular magnetic resonance (CMR) technique, and to compare it with clinically used two-dimensional breath-hold LGE (2D BH-LGE). METHODS:The proposed 3D FB-LGE method consisted of inversion preparation, inversion dela...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26234

    authors: Menon RG,Miller GW,Jeudy J,Rajagopalan S,Shin T

    更新日期:2017-04-01 00:00:00

  • Multi-echo length and offset VARied saturation (MeLOVARS) method for improved CEST imaging.

    abstract:PURPOSE:The aim of this study was to develop a technique for rapid collection of chemical exchange saturation transfer images with the saturation varied to modulate signal loss transfer and enhance contrast. METHODS:Multi-echo Length and Offset VARied Saturation (MeLOVARS) divides the saturation pulse of length Tsat i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25567

    authors: Song X,Xu J,Xia S,Yadav NN,Lal B,Laterra J,Bulte JW,van Zijl PC,McMahon MT

    更新日期:2015-02-01 00:00:00

  • Cerebral glucose is detectable by localized proton NMR spectroscopy in normal rat brain in vivo.

    abstract::This contribution reports the first direct and noninvasive observation of cerebral glucose in normal anesthetized rats (n = 16) using short-echo-time localized proton NMR spectroscopy (2.35 T, STEAM, TR = 6000 ms, TE = 20 ms, 125 microliters). In addition to resonances from N-acetyl aspartate (NAA), glutamate, total c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190243

    authors: Gyngell ML,Michaelis T,Hörstermann D,Bruhn H,Hänicke W,Merboldt KD,Frahm J

    更新日期:1991-06-01 00:00:00

  • Simultaneous QSM and metabolic imaging of the brain using SPICE.

    abstract:PURPOSE:To map brain metabolites and tissue magnetic susceptibility simultaneously using a single three-dimensional 1 H-MRSI acquisition without water suppression. METHODS:The proposed technique builds on a subspace imaging method called spectroscopic imaging by exploiting spatiospectral correlation (SPICE), which ena...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26972

    authors: Peng X,Lam F,Li Y,Clifford B,Liang ZP

    更新日期:2018-01-01 00:00:00

  • Differential effect of isoflurane, medetomidine, and urethane on BOLD responses to acute levo-tetrahydropalmatine in the rat.

    abstract::Levo-tetrahydropalmatine (l-THP) has shown significant promise in preclinical and clinical studies to treat drug addiction. Pharmacological MRI methods can elucidate the regional cerebral effects of l-THP, but there are potential confounds from the use of general anesthesia. To investigate the possible anesthetic-drug...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23243

    authors: Liu X,Li R,Yang Z,Hudetz AG,Li SJ

    更新日期:2012-08-01 00:00:00

  • Visualization of cortical spreading depression using manganese-enhanced magnetic resonance imaging.

    abstract::Cortical spreading depression (CSD) was visualized using manganese-enhanced MRI (MEMRI) following topical application of KCl to the exposed rat cortex. MEMRI signal increase in the ipsilateral cortex relative to the contralateral control region was 60 +/- 30% following two KCl applications. MEMRI signal increase for a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20438

    authors: Henning EC,Meng X,Fisher M,Sotak CH

    更新日期:2005-04-01 00:00:00

  • T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

    abstract::T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE method...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21215

    authors: Kellman P,Aletras AH,Mancini C,McVeigh ER,Arai AE

    更新日期:2007-05-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Transcatheter intra-arterial perfusion (TRIP)-MRI biomarkers help detect immediate response to irreversible electroporation of rabbit VX2 liver tumor.

    abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28104

    authors: Figini M,Zhou K,Pan L,Sun C,Wang B,Hu S,Yang J,Shangguan J,Eresen A,Velichko Y,Yaghmai V,Zhang Z

    更新日期:2020-07-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • Global and peak local specific absorption rate control on parallel transmit systems using k-means SAR compression model.

    abstract:PURPOSE:To improve the specific absorption rate (SAR) compression model capability in parallel transmission (pTx) MRI systems. METHODS:A k-means clustering method is proposed to group voxels with similar SAR behaviors in the scanned object, providing a controlled upper-bounded estimation of peak local SARs. This k-mea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28456

    authors: Mao X,Bari S,Love DJ,Rispoli JV

    更新日期:2021-02-01 00:00:00

  • Comparison of fitting methods and b-value sampling strategies for intravoxel incoherent motion in breast cancer.

    abstract:PURPOSE:To compare fitting methods and sampling strategies, including the implementation of an optimized b-value selection for improved estimation of intravoxel incoherent motion (IVIM) parameters in breast cancer. METHODS:Fourteen patients (age, 48.4 ± 14.27 years) with cancerous lesions underwent 3 Tesla breast MRI ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25484

    authors: Cho GY,Moy L,Zhang JL,Baete S,Lattanzi R,Moccaldi M,Babb JS,Kim S,Sodickson DK,Sigmund EE

    更新日期:2015-10-01 00:00:00

  • Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25101

    authors: Powell NJ,Jang A,Park JY,Valette J,Garwood M,Marjańska M

    更新日期:2015-01-01 00:00:00

  • Data-driven optimized flip angle selection for T1 estimation from spoiled gradient echo acquisitions.

    abstract:PURPOSE:Define criteria for selection of optimal flip angle sets for T1 estimation and evaluate effects on T1 mapping. THEORY AND METHODS:Flip angle sets for spoiled gradient echo-based T1 mapping were selected by minimizing T1 estimate variance weighted by the joint density of M0 and T1 in an initial acquisition. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25920

    authors: Lewis CM,Hurley SA,Meyerand ME,Koay CG

    更新日期:2016-09-01 00:00:00

  • Real-time observation of transient focal ischemia and hyperemia in cat brain.

    abstract::Gradient-recalled echo-planar (T2*-weighted) imaging was used to noninvasively monitor regional blood oxygenation state changes in real time during transient episodes of focal ischemia in cat brain. Varying ischemic intervals (12 s to 30 min) were caused by middle cerebral artery occlusion. A rapid signal drop was not...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270220

    authors: De Crespigny AJ,Wendland MF,Derugin N,Kozniewska E,Moseley ME

    更新日期:1992-10-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • A statistical approach to SENSE regularization with arbitrary k-space trajectories.

    abstract::SENSE reconstruction suffers from an ill-conditioning problem, which increasingly lowers the signal-to-noise ratio (SNR) as the reduction factor increases. Ill-conditioning also degrades the convergence behavior of iterative conjugate gradient reconstructions for arbitrary trajectories. Regularization techniques are o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21665

    authors: Ying L,Liu B,Steckner MC,Wu G,Wu M,Li SJ

    更新日期:2008-08-01 00:00:00

  • Stability constants and 1H relaxation effects of ternary complexes formed between Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, and Gd-EDTA and citrate, phosphate, and carbonate ions.

    abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380120

    authors: Burai L,Hietapelto V,Király R,Tóth E,Brücher E

    更新日期:1997-07-01 00:00:00

  • Phosphonate-modified GdDTPA complexes. I. NMRD study of the solution behavior of new tissue-specific contrast agents.

    abstract::NMRD profiles, the magnetic field dependence of the water proton longitudinal relaxation rates, have been acquired for two new diphosphonate-modified GdDTPA complexes currently under evaluation as relaxation agents for the MRI detection of soft-tissue calcifications. Fresh dilute solutions show profiles identical to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170118

    authors: Adzamli IK,Blau M

    更新日期:1991-01-01 00:00:00

  • TOWERS: T-One with Enhanced Robustness and Speed.

    abstract:PURPOSE:A new T1 mapping method is proposed that is accurate, rapid, and robust to motion. Considering these features, the method is dubbed "T-One with Enhanced Robustness and Speed (TOWERS)." METHODS:TOWERS is composed of inversion recovery (IR) and saturation recovery (SR) acquisitions. In the IR acquisitions, a sli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25864

    authors: Eldeniz C,Finsterbusch J,Lin W,An H

    更新日期:2016-07-01 00:00:00

  • Feasibility study of imaging a living murine tumor by electron paramagnetic resonance.

    abstract::An electron paramagnetic resonance image was measured for the first time from in vivo field gradient spectra of a living murine tumor (Cloudman S-91 melanoma in the tail of a DBA-2J mouse) using the paramagnetic nitroxide imaging agent 3-carboxamido-2,2,5,5-tetramethylpyrroline-1-oxyl injected into the tail vein. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040410

    authors: Berliner LJ,Fujii H,Wan XM,Lukiewicz SJ

    更新日期:1987-04-01 00:00:00

  • Incorporation of Rician noise in the analysis of biexponential transverse relaxation in cartilage using a multiple gradient echo sequence at 3 and 7 Tesla.

    abstract:PURPOSE:Previous work has evaluated the quality of different analytic methods for extracting relaxation times from magnitude imaging data exhibiting Rician noise. However, biexponential analysis of relaxation in tissue, including cartilage, and materials is of increasing interest. We, therefore, analyzed biexponential ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25111

    authors: Bouhrara M,Reiter DA,Celik H,Bonny JM,Lukas V,Fishbein KW,Spencer RG

    更新日期:2015-01-01 00:00:00

  • Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.

    abstract:PURPOSE:Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS:A truly hybrid US...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26897

    authors: Celicanin Z,Manasseh G,Petrusca L,Scheffler K,Auboiroux V,Crowe LA,Hyacinthe JN,Natsuaki Y,Santini F,Becker CD,Terraz S,Bieri O,Salomir R

    更新日期:2018-05-01 00:00:00

  • Model-free arterial spin labeling quantification approach for perfusion MRI.

    abstract::In this work a model-free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20784

    authors: Petersen ET,Lim T,Golay X

    更新日期:2006-02-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00