Intravoxel distribution of DWI decay rates reveals C6 glioma invasion in rat brain.

Abstract:

:The hypothesis was tested that the intravoxel distribution of water diffusion rates, as measured with a stretched-exponential model of diffusion-weighted imaging (DWI), is a marker of brain tumor invasion. Eight rats underwent intracerebral inoculation of C6 glioma cells. In three rats, cells were labeled with a fluorescent dye for microscopy. One rat was inoculated with a saline solution, and five more rats were imaged without inoculation as controls. Five healthy uninoculated rats were also imaged. DWI was performed 14-15 days after inoculation, with diffusion-weighting factor b = 500 to 6500 sec/mm2, and the resulting signal attenuation was fitted with the stretched-exponential model. The heterogeneity index values were significantly lower (P < 0.05) in the peritumor ROI than in normal gray matter and significantly higher than in normal white matter. The distributed diffusion coefficient values were significantly lower than in normal white matter or normal gray matter. Fluorescence microscopy confirmed the presence of tumors in the peritumor region that could be histologically distinguished from the main tumor mass. There was no change in proton density or T2-weighted images in the peritumor region, making vasogenic edema unlikely as a source of contrast. It is therefore thought that the heterogeneity parameter alpha is a marker of brain tumor invasion.

journal_name

Magn Reson Med

authors

Bennett KM,Hyde JS,Rand SD,Bennett R,Krouwer HG,Rebro KJ,Schmainda KM

doi

10.1002/mrm.20286

subject

Has Abstract

pub_date

2004-11-01 00:00:00

pages

994-1004

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

52

pub_type

杂志文章
  • Transceive phase mapping using the PLANET method and its application for conductivity mapping in the brain.

    abstract:PURPOSE:To demonstrate feasibility of transceive phase mapping with the PLANET method and its application for conductivity reconstruction in the brain. METHODS:Accuracy and precision of transceive phase (ϕ± ) estimation with PLANET, an ellipse fitting approach to phase-cycled balanced steady state free precession (bSS...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27958

    authors: Gavazzi S,Shcherbakova Y,Bartels LW,Stalpers LJA,Lagendijk JJW,Crezee H,van den Berg CAT,van Lier ALHMW

    更新日期:2020-02-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • In vivo study of microbubbles as an MR susceptibility contrast agent.

    abstract::The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different dos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20181

    authors: Wong KK,Huang I,Kim YR,Tang H,Yang ES,Kwong KK,Wu EX

    更新日期:2004-09-01 00:00:00

  • Utilizing magnetization transfer imaging to investigate tissue remodeling in a murine model of autosomal dominant polycystic kidney disease.

    abstract:PURPOSE:Noninvasive imaging techniques that quantify renal tissue composition are needed to more accurately ascertain prognosis and monitor disease progression in polycystic kidney disease (PKD). Given the success of magnetization transfer (MT) imaging to characterize various tissue remodeling pathologies, it was teste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25701

    authors: Kline TL,Irazabal MV,Ebrahimi B,Hopp K,Udoji KN,Warner JD,Korfiatis P,Mishra PK,Macura SI,Venkatesh SK,Lerman LO,Harris PC,Torres VE,King BF,Erickson BJ

    更新日期:2016-04-01 00:00:00

  • Perfusion MRI of U87 brain tumors in a mouse model.

    abstract::Continuous arterial spin labeling (CASL) was used to obtain an index of cerebral blood flow (ICBF) in the normal mouse brain and in an orthotopic mouse model of human U87 high-grade glioma at 8.5 T. Under the assumption of a constant tissue:blood partition coefficient for water in different tissues, the mean ICBF (n =...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20029

    authors: Sun Y,Schmidt NO,Schmidt K,Doshi S,Rubin JB,Mulkern RV,Carroll R,Ziu M,Erkmen K,Poussaint TY,Black P,Albert M,Burstein D,Kieran MW

    更新日期:2004-05-01 00:00:00

  • 31P RINEPT MRSI and VBM reveal alterations in brain aging associated with major depression.

    abstract:PURPOSE:Phosphomono- and diesters, the major components of the choline peak in (1) H magnetic resonance spectroscopy, are associated with membrane anabolic and catabolic mechanisms. With the refocused insensitive nuclei-enhanced polarization transfer technique, these phospholipids are edited and enhanced in the (31) P ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25278

    authors: Biedermann SV,Weber-Fahr W,Demirakca T,Tunc-Skarka N,Hoerst M,Henn F,Sartorius A,Ende G

    更新日期:2015-04-01 00:00:00

  • 3D-multi-spectral T2 mapping near metal implants.

    abstract:PURPOSE:Due to host-mediated adverse reaction to metallic debris, there is an increasing need for noninvasive assessment of the soft tissue surrounding large joint arthroplasties. Quantitative T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27744

    authors: Bhave S,Koff MF,Sivaram Kaushik S,Potter HG,Koch KM

    更新日期:2019-08-01 00:00:00

  • The impact of the relaxivity definition on the quantitative measurement of glycosaminoglycans in cartilage by the MRI dGEMRIC method.

    abstract::The relaxivities (R-values) of the gadolinium diethylene triamine pentaacetic acid (Gd(DTPA)2-) ions in a series of skim-milk solutions at 0-40% milk concentrations were measured using NMR spectroscopy. The R-value was found to be approximately linearly proportional to the concentration of the solid component in the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22169

    authors: Zheng S,Xia Y

    更新日期:2010-01-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • T2 relaxation reveals spatial collagen architecture in articular cartilage: a comparative quantitative MRI and polarized light microscopic study.

    abstract::It has been suggested that orientational changes in the collagen network of articular cartilage account for the depthwise T2 anisotropy of MRI through the magic angle effect. To investigate the relationship between laminar T2 appearance and collagen organization (anisotropy), bovine osteochondral plugs (N = 9) were T2...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1218

    authors: Nieminen MT,Rieppo J,Töyräs J,Hakumäki JM,Silvennoinen J,Hyttinen MM,Helminen HJ,Jurvelin JS

    更新日期:2001-09-01 00:00:00

  • Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

    abstract::In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position wa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10390

    authors: Peters DC,Lederman RJ,Dick AJ,Raman VK,Guttman MA,Derbyshire JA,McVeigh ER

    更新日期:2003-02-01 00:00:00

  • Strategy for the spectral filtering of myo-inositol and other strongly coupled spins.

    abstract::A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10697

    authors: Kim H,Wild JM,Allen PS

    更新日期:2004-02-01 00:00:00

  • Transmit SENSE.

    abstract::The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of multiple receive coils can be adapted for the parallel transmission of a spatially-selective multidimensional RF pulse. As in data acquisition, a multidimensional RF pulse follows a certain k-space trajectory. Shortening this...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10353

    authors: Katscher U,Börnert P,Leussler C,van den Brink JS

    更新日期:2003-01-01 00:00:00

  • Model-free arterial spin labeling quantification approach for perfusion MRI.

    abstract::In this work a model-free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20784

    authors: Petersen ET,Lim T,Golay X

    更新日期:2006-02-01 00:00:00

  • Trajectory optimization based on the signal-to-noise ratio for spatial encoding with nonlinear encoding fields.

    abstract:PURPOSE:Multiple nonlinear gradient fields offer many potential benefits for spatial encoding including reduced acquisition time, fewer artefacts and region-specific imaging, although designing a suitable trajectory for such a setup is difficult. This work aims to optimize encoding trajectories for multiple nonlinear g...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25859

    authors: Layton KJ,Kroboth S,Jia F,Littin S,Yu H,Zaitsev M

    更新日期:2016-07-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21614

    authors: Leupold J,Hennig J,Scheffler K

    更新日期:2008-07-01 00:00:00

  • Comparison of blood oxygenation and cerebral blood flow effects in fMRI: estimation of relative oxygen consumption change.

    abstract::The most widely-used functional magnetic resonance imaging (fMRI) technique is based on the blood oxygenation level dependent (BOLD) effect, which requires at least partial uncoupling between cerebral blood flow (CBF) and oxygen consumption changes during increased mental activity. To compare BOLD and CBF effects duri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380110

    authors: Kim SG,Uğurbil K

    更新日期:1997-07-01 00:00:00

  • Calcium-induced structural changes of cartilage proteoglycans studied by H NMR relaxometry and diffusion measurements.

    abstract::1H transverse nuclear magnetic relaxation times (T2) and self-diffusion coefficients (SDCs) of water were measured in isolated proteoglycan aggregates from pig articular cartilage. The influence of varying osmotic pressure, as well as of different calcium concentrations, on the samples was investigated. Due to a struc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<43::aid-mrm8>3

    authors: Werner A,Gründer W

    更新日期:1999-01-01 00:00:00

  • Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla.

    abstract:PURPOSE:To characterize and optimize 19 F MRI for different perfluorocarbons (PFCs) at 3T and quantify the loss of acquisition efficiency as a function of different temperature and cellular conditions. METHODS:The T1 and T2 relaxation times of the commonly used PFCs perfluoropolyether (PFPE), perfluoro-15-crown-5-ethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26317

    authors: Colotti R,Bastiaansen JAM,Wilson A,Flögel U,Gonzales C,Schwitter J,Stuber M,van Heeswijk RB

    更新日期:2017-06-01 00:00:00

  • High-resolution FMRI at 1.5T using balanced SSFP.

    abstract::The resolution in conventional BOLD FMRI is considerably lower than can be achieved with other MRI methods, and is insufficient for many important applications. One major difficulty in robustly improving spatial resolution is the poor image quality in BOLD FMRI, which suffers from distortions, blurring, and signal dro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20753

    authors: Miller KL,Smith SM,Jezzard P,Pauly JM

    更新日期:2006-01-01 00:00:00

  • Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

    abstract:PURPOSE:A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultane...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27113

    authors: Hoge WS,Setsompop K,Polimeni JR

    更新日期:2018-10-01 00:00:00

  • T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

    abstract::T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22178

    authors: Raya JG,Dietrich O,Horng A,Weber J,Reiser MF,Glaser C

    更新日期:2010-01-01 00:00:00

  • Dynamic oxygen-enhanced MRI reflects diffusing capacity of the lung.

    abstract::The purpose of this study was to demonstrate the feasibility of dynamic oxygen-enhanced MRI in a clinical setting. We hypothesized that dynamic oxygen enhancement can reflect the regional diffusing capacity of the lung. Ten patients with pulmonary emphysema and seven healthy volunteers were examined with a respiratory...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10168

    authors: Ohno Y,Hatabu H,Takenaka D,Van Cauteren M,Fujii M,Sugimura K

    更新日期:2002-06-01 00:00:00

  • Fast and accurate measurements of T1 using a multi-readout single inversion-recovery sequence.

    abstract::TOMROP is a multiple readout single inversion-recovery sequence which may potentially allow the measurement of multi-exponential T1 recoveries in vivo by NMR imaging. It is shown that several important modifications must be made to this sequence to permit T1 to be measured accurately and reliably. With these modificat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260109

    authors: Gowland PA,Leach MO

    更新日期:1992-07-01 00:00:00

  • In vivo 13C magnetic resonance spectroscopy of human brain on a clinical 3 T scanner using [2-13C]glucose infusion and low-power stochastic decoupling.

    abstract::This study presents the detection of [2-(13)C]glucose metabolism in the carboxylic/amide region in the human brain, and demonstrates that the cerebral metabolism of [2-(13)C]glucose can be studied in human subjects in the presence of severe hardware constraints of widely available 3 T clinical scanners and with low-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22044

    authors: Li S,Zhang Y,Wang S,Yang J,Ferraris Araneta M,Farris A,Johnson C,Fox S,Innis R,Shen J

    更新日期:2009-09-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • Optimized isotropic diffusion weighting.

    abstract::The authors introduce several sets of time-efficient gradient waveforms for applying isotropic diffusion weighting in NMR experiments. This creates signal attenuation that depends on the trace of the diffusion tensor and is therefore rotationally invariant. Numerical methods for the calculation of such gradient sets a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340202

    authors: Wong EC,Cox RW,Song AW

    更新日期:1995-08-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00

  • India ink: a potential clinically applicable EPR oximetry probe.

    abstract::Using a material that already is in widespread use in humans, India ink, the first EPR measurements in a human have been made, using the India ink in a pre-existing tattoo. The EPR spectra of India ink are very sensitive to the partial pressure of oxygen (pO2), thereby making it feasible to use this approach to measur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310218

    authors: Swartz HM,Liu KJ,Goda F,Walczak T

    更新日期:1994-02-01 00:00:00