Transceive phase mapping using the PLANET method and its application for conductivity mapping in the brain.

Abstract:

PURPOSE:To demonstrate feasibility of transceive phase mapping with the PLANET method and its application for conductivity reconstruction in the brain. METHODS:Accuracy and precision of transceive phase (ϕ± ) estimation with PLANET, an ellipse fitting approach to phase-cycled balanced steady state free precession (bSSFP) data, were assessed with simulations and measurements and compared to standard bSSFP. Measurements were conducted on a homogeneous phantom and in the brain of healthy volunteers at 3 tesla. Conductivity maps were reconstructed with Helmholtz-based electrical properties tomography. In measurements, PLANET was also compared to a reference technique for transceive phase mapping, i.e., spin echo. RESULTS:Accuracy and precision of ϕ± estimated with PLANET depended on the chosen flip angle and TR. PLANET-based ϕ± was less sensitive to perturbations induced by off-resonance effects and partial volume (e.g., white matter + myelin) than bSSFP-based ϕ± . For flip angle = 25° and TR = 4.6 ms, PLANET showed an accuracy comparable to that of reference spin echo but a higher precision than bSSFP and spin echo (factor of 2 and 3, respectively). The acquisition time for PLANET was ~5 min; 2 min faster than spin echo and 8 times slower than bSSFP. However, PLANET simultaneously reconstructed T1 , T2 , B0 maps besides mapping ϕ± . In the phantom, PLANET-based conductivity matched the true value and had the smallest spread of the three methods. In vivo, PLANET-based conductivity was similar to spin echo-based conductivity. CONCLUSION:Provided that appropriate sequence parameters are used, PLANET delivers accurate and precise ϕ± maps, which can be used to reconstruct brain tissue conductivity while simultaneously recovering T1 , T2 , and B0 maps.

journal_name

Magn Reson Med

authors

Gavazzi S,Shcherbakova Y,Bartels LW,Stalpers LJA,Lagendijk JJW,Crezee H,van den Berg CAT,van Lier ALHMW

doi

10.1002/mrm.27958

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

590-607

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

83

pub_type

杂志文章
  • Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T.

    abstract::Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21345

    authors: Stalder AF,Elverfeldt DV,Paul D,Hennig J,Markl M

    更新日期:2008-01-01 00:00:00

  • Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR.

    abstract::A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21194

    authors: Devasahayam N,Subramanian S,Murugesan R,Hyodo F,Matsumoto K,Mitchell JB,Krishna MC

    更新日期:2007-04-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • A comparison of static and dynamic ∆B0 mapping methods for correction of CEST MRI in the presence of temporal B0 field variations.

    abstract:PURPOSE:To assess the performance, in the presence of scanner instabilities, of three dynamic correction methods which integrate ∆B0 mapping into the chemical exchange saturation transfer (CEST) measurement and three established static ∆B0 -correction approaches. METHODS:A homogeneous phantom and five healthy voluntee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27750

    authors: Poblador Rodriguez E,Moser P,Dymerska B,Robinson S,Schmitt B,van der Kouwe A,Gruber S,Trattnig S,Bogner W

    更新日期:2019-08-01 00:00:00

  • Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T.

    abstract:PURPOSE:To establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. METHODS:Measurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequenc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27038

    authors: Jaeschke SHF,Robson MD,Hess AT

    更新日期:2018-08-01 00:00:00

  • Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain.

    abstract::Healthy human brain diffusion anisotropy maps derived from standard spin echo diffusion tensor imaging (DTI) were compared with those using fluid-attenuated inversion recovery (FLAIR) preparation prior to DTI to null the signal from cerebrospinal fluid (CSF). Consistent comparisons entailed development of DTI postproc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10204

    authors: Papadakis NG,Martin KM,Mustafa MH,Wilkinson ID,Griffiths PD,Huang CL,Woodruff PW

    更新日期:2002-08-01 00:00:00

  • Transmit SENSE.

    abstract::The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of multiple receive coils can be adapted for the parallel transmission of a spatially-selective multidimensional RF pulse. As in data acquisition, a multidimensional RF pulse follows a certain k-space trajectory. Shortening this...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10353

    authors: Katscher U,Börnert P,Leussler C,van den Brink JS

    更新日期:2003-01-01 00:00:00

  • Single-Voxel 1 H MR spectroscopy of cerebral nicotinamide adenine dinucleotide (NAD+ ) in humans at 7T using a 32-channel volume coil.

    abstract:PURPOSE:Reliable monitoring of tissue nicotinamide adenine dinucleotide (NAD+ ) concentration may provide insights on its roles in normal and pathological aging. In the present study, we report a 1 H MRS pulse sequence for the in vivo, localized 1 H MRS detection of NAD+ from the human brain. METHODS:Studies were carr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27971

    authors: Bagga P,Hariharan H,Wilson NE,Beer JC,Shinohara RT,Elliott MA,Baur JA,Marincola FM,Witschey WR,Haris M,Detre JA,Reddy R

    更新日期:2020-03-01 00:00:00

  • Incorporation of Rician noise in the analysis of biexponential transverse relaxation in cartilage using a multiple gradient echo sequence at 3 and 7 Tesla.

    abstract:PURPOSE:Previous work has evaluated the quality of different analytic methods for extracting relaxation times from magnitude imaging data exhibiting Rician noise. However, biexponential analysis of relaxation in tissue, including cartilage, and materials is of increasing interest. We, therefore, analyzed biexponential ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25111

    authors: Bouhrara M,Reiter DA,Celik H,Bonny JM,Lukas V,Fishbein KW,Spencer RG

    更新日期:2015-01-01 00:00:00

  • A continuum of T 2 * components: Flexible fast fraction mapping in sodium MRI.

    abstract:PURPOSE:Parameter mapping in sodium MRI data is challenging due to inherently low SNR and spatial resolution, prompting the need to employ robust models and estimation techniques. This work aims to develop a continuum model of sodium T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27659

    authors: Syeda W,Blunck Y,Kolbe S,Cleary JO,Johnston LA

    更新日期:2019-06-01 00:00:00

  • Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

    abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21095

    authors: Gabr RE,Aksit P,Bottomley PA,Youssef AB,Kadah YM

    更新日期:2006-12-01 00:00:00

  • Potential degradation in image quality due to selective averaging of phase-encoding lines in Fourier transform MRI.

    abstract::The properties of the image noise for selective averaging of phase-encoding lines have been investigated. For a given acquisition time, selective averaging results in a signal-to-noise ratio penalty compared to averaging all lines equally. In addition, selective averaging yields a non uniform distribution of noise cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190115

    authors: Mugler JP 3rd

    更新日期:1991-05-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Iterative projection onto convex sets for quantitative susceptibility mapping.

    abstract:PURPOSE:Quantitative susceptibility map (QSM) reconstruction is ill posed due to the zero values on the "magic angle cone" that make the maps prone to streaking artifacts. We propose projection onto convex sets (POCS) in the method of steepest descent (SD) for QSM reconstruction. METHODS:Two convex projections, an obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25155

    authors: Deng W,Boada F,Poser BA,Schirda C,Stenger VA

    更新日期:2015-02-01 00:00:00

  • Investigation of resolution effects using a specialized diffusion tensor phantom.

    abstract:PURPOSE:The clinical potential of the diffusion imaging-based analysis of fine brain structures such as fornix or cingulum is high due to the central role of these structures in psychiatric diseases. However, the quantification of diffusion parameters in fine structures is especially prone to partial volume effects (PV...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24774

    authors: Bach M,Fritzsche KH,Stieltjes B,Laun FB

    更新日期:2014-03-01 00:00:00

  • Solvate structures in water-methanol solutions of MRI contrast agents: electron spin echo envelope modulation in gadolinium chelates.

    abstract::Electron Spin Echo Envelope Modulation (ESEEM) data are reported for three gadolinium (III) chelates, Gd-EDTA, Gd-DTPA, and Gd-TTHA, in frozen D2O/CH3OD glasses. This series includes Gd-DTPA, an MRI contrast agent that is in clinical use. Three-pulse electron spin echo modulation patterns can be modeled to yield geome...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290414

    authors: Clarkson RB,Hwang JH,Belford RL

    更新日期:1993-04-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • In vivo and ex vivo MR imaging of slowly cycling melanoma cells.

    abstract::Slowly cycling cells are believed to play a critical role in tumor progression and metastatic dissemination. The goal of this study was to develop a method for in vivo detection of slowly cycling cells. To distinguish these cells from more rapidly proliferating cells that constitute the vast majority of cells in tumor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22917

    authors: Magnitsky S,Roesch A,Herlyn M,Glickson JD

    更新日期:2011-11-01 00:00:00

  • Advanced fit of the diffusion kurtosis tensor by directional weighting and regularization.

    abstract::The diffusional kurtosis is an indicator for diffusion restrictions in biological tissue. It is observed experimentally that the kurtosis is largest for directions perpendicular to the fiber direction in white matter. The directional dependence of the kurtosis can be described by the diffusion kurtosis tensor. Since t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23133

    authors: Kuder TA,Stieltjes B,Bachert P,Semmler W,Laun FB

    更新日期:2012-05-01 00:00:00

  • Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain.

    abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22426

    authors: Aggarwal M,Mori S,Shimogori T,Blackshaw S,Zhang J

    更新日期:2010-07-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • Biexponential longitudinal relaxation in white matter: Characterization and impact on T1 mapping with IR-FSE and MP2RAGE.

    abstract:PURPOSE:Magnetization transfer in white matter (WM) causes biexponential relaxation, but most quantitative T1 measurements fit data assuming monoexponential relaxation. The resulting monoexponential T1 estimate varies based on scan parameters and represents a source of variation between studies, especially at high fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25729

    authors: Rioux JA,Levesque IR,Rutt BK

    更新日期:2016-06-01 00:00:00

  • Gradient field switching as a source for artifacts in MR imaging of metallic stents.

    abstract::Metallic implants, such as stents, have long been a concern in magnetic resonance imaging (MRI). In addition to safety issues, they are commonly associated with image artifacts. The mechanisms of radiofrequency- (RF) and susceptibility-induced artifacts have been thoroughly investigated. However, gradient-switching-in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20294

    authors: Shenhav A,Azhari H

    更新日期:2004-12-01 00:00:00

  • Evaluation of hepatic steatosis before liver transplantation in ex vivo by volumetric quantitative PDFF-MRI.

    abstract:PURPOSE:Over the last two decades, extended criteria have promoted an increased number of donor livers available for liver transplantation. But posttransplant graft loss is still a major concern. Macrovesicular hepatic steatosis (MHS) is recognized as the most significant prognostic histologic parameter in predicting p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28592

    authors: Chen G,Jiang J,Wang X,Yang M,Xie Y,Guo H,Tang H,Zhou L,Hu D,Kamel IR,Chen Z,Li Z

    更新日期:2020-11-16 00:00:00

  • MRI visualization of rodent liver structure and peritoneal adhesion with dialyzate enhancement.

    abstract::This study investigated the use of peritoneal dialysis fluid (dialyzate) as a MR contrast agent to visualize the liver structure and peritoneal adhesion in rats at 7 T. Intraperitoneal injection of dialyzate (approximately 0.1 ml/g) yielded excellent and consistent intraperitoneal enhancement that delineated the liver...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21506

    authors: Cheung JS,Guo H,Leung JC,Man K,Lai KN,Wu EX

    更新日期:2008-05-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

    abstract:PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27439

    authors: Goldenberg JM,Cárdenas-Rodríguez J,Pagel MD

    更新日期:2019-01-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • Effects of the acoustic noise of the gradient systems on fMRI: a study on auditory, motor, and visual cortices.

    abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390224

    authors: Cho ZH,Chung SC,Lim DW,Wong EK

    更新日期:1998-02-01 00:00:00

  • Phase-based T2 mapping with gradient echo imaging.

    abstract:PURPOSE:Transverse relaxation time (T2 ) mapping with MRI has a plethora of clinical and research applications. Current T2 mapping techniques are based primarily on spin-echo (SE) relaxometry strategies that rely on the signal magnitude, and often suffer from lengthy acquisition times. In this work, we propose a phase-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28138

    authors: Wang X,Hernando D,Reeder SB

    更新日期:2020-08-01 00:00:00