Optimized isotropic diffusion weighting.

Abstract:

:The authors introduce several sets of time-efficient gradient waveforms for applying isotropic diffusion weighting in NMR experiments. This creates signal attenuation that depends on the trace of the diffusion tensor and is therefore rotationally invariant. Numerical methods for the calculation of such gradient sets are outlined, and results are shown for isotropic and anisotropic gradient hardware and first order flow moment nulled diffusion weighting gradients. Preliminary experimental results from the human brain validate this new technique.

journal_name

Magn Reson Med

authors

Wong EC,Cox RW,Song AW

doi

10.1002/mrm.1910340202

subject

Has Abstract

pub_date

1995-08-01 00:00:00

pages

139-43

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

34

pub_type

杂志文章
  • Time-domain combination of MR spectroscopy data acquired using phased-array coils.

    abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20244

    authors: Brown MA

    更新日期:2004-11-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • System identification theory in pharmacokinetic modeling of dynamic contrast-enhanced MRI: influence of contrast injection.

    abstract::Optimization of experimental settings of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), like the contrast administration protocol, is of great importance for reliable quantification of the microcirculatory properties, such as the volume transfer-constant K(trans). Using system identification theory an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21575

    authors: Aerts HJ,van Riel NA,Backes WH

    更新日期:2008-05-01 00:00:00

  • Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

    abstract::An eight-channel receive-only brain coil and table-top detunable volume transmit coil were developed and tested at 7 T for human imaging. Optimization of this device required attention to sources of interaction between the array elements, between the transmit and receive coils and minimization of common mode currents ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20547

    authors: Wiggins GC,Potthast A,Triantafyllou C,Wiggins CJ,Wald LL

    更新日期:2005-07-01 00:00:00

  • Fast acquisition-weighted three-dimensional proton MR spectroscopic imaging of the human prostate.

    abstract::The clinical application of 3D proton spectroscopic imaging (3D SI) of the human prostate requires a robust suppression of periprostatic lipid signal contamination, minimal intervoxel signal contamination, and the shortest possible measurement time. In this work, a weighted elliptical sampling of k-space, combined wit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20103

    authors: Scheenen TW,Klomp DW,Röll SA,Fütterer JJ,Barentsz JO,Heerschap A

    更新日期:2004-07-01 00:00:00

  • Human whole-blood (1)H2O longitudinal relaxation with normal and high-relaxivity contrast reagents: influence of trans-cell-membrane water exchange.

    abstract:PURPOSE:Accurate characterization of contrast reagent (CR) longitudinal relaxivity in whole blood is required to predict arterial signal intensity in contrast-enhanced MR angiography (CE-MRA). This study measured the longitudinal relaxation rate constants (R1 ) over a concentration range for non-protein-binding and pro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25064

    authors: Wilson GJ,Woods M,Springer CS Jr,Bastawrous S,Bhargava P,Maki JH

    更新日期:2014-12-01 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • Triple diffusion encoding MRI predicts intra-axonal and extra-axonal diffusion tensors in white matter.

    abstract:PURPOSE:To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS:Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28084

    authors: Ramanna S,Moss HG,McKinnon ET,Yacoub E,Helpern JA,Jensen JH

    更新日期:2020-06-01 00:00:00

  • High-resolution 1H NMR spectroscopy in rat liver using magic angle turning at a 1 Hz spinning rate.

    abstract::It is demonstrated that a high-resolution (1)H NMR spectrum of excised rat liver can be obtained using the technique of magic angle turning (MAT) at a sample spinning rate of 1 Hz. A variant of the phase-corrected MAT (PHORMAT) pulse sequence that includes a water suppression segment was developed for the investigatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10139

    authors: Hu JZ,Rommereim DN,Wind RA

    更新日期:2002-05-01 00:00:00

  • Diffusion imaging of the spinal cord in vivo: estimation of the principal diffusivities and application to multiple sclerosis.

    abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16

    authors: Clark CA,Werring DJ,Miller DH

    更新日期:2000-01-01 00:00:00

  • Mapping murine diabetic kidney disease using chemical exchange saturation transfer MRI.

    abstract:PURPOSE:Diabetic nephropathy (DN) is the leading cause of renal failure; however, current clinical tests are insufficient for assessing this disease. DN is associated with changes in renal metabolites, so we evaluated the utility of chemical exchange saturation transfer (CEST) imaging to detect changes characteristic o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26045

    authors: Wang F,Kopylov D,Zu Z,Takahashi K,Wang S,Quarles CC,Gore JC,Harris RC,Takahashi T

    更新日期:2016-11-01 00:00:00

  • Motion corrected water/fat whole-heart coronary MR angiography with 100% respiratory efficiency.

    abstract:PURPOSE:To develop a framework for respiratory motion-corrected 3D whole-heart water/fat coronary MR angiography (CMRA) at 3T with reduced and predictable scan time. METHODS:A 3D dual-echo acquisition and respiratory motion-corrected reconstruction framework for water/fat CMRA imaging was developed. The acquisition se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27732

    authors: Munoz C,Cruz G,Neji R,Botnar RM,Prieto C

    更新日期:2019-08-01 00:00:00

  • Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model.

    abstract:PURPOSE:To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-nois...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28473

    authors: Shepelytskyi Y,Li T,Grynko V,Newman C,Hane FT,Albert MS

    更新日期:2021-02-01 00:00:00

  • Combined functional and viability cardiac MR imaging in a single breathhold.

    abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21390

    authors: Ibrahim el-SH,Stuber M,Kraitchman DL,Weiss RG,Osman NF

    更新日期:2007-10-01 00:00:00

  • Stability assessment of gadolinium complexes by P-31 and H-1 relaxometry.

    abstract::Longitudinal P-31 relaxation rate enhancements of phosphate groups have been measured at pH 7-7.2 and 310 degrees K on aqueous solutions containing adenosine triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and some lanthanide complexes (Gd-DOTA, Gd-HPDO3A, Gd-DO3A, Gd-DTPA, Gd-DTPA-BMA). The macroc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310413

    authors: Vander Elst L,Van Haverbeke Y,Goudemant JF,Muller RN

    更新日期:1994-04-01 00:00:00

  • Assessment and compensation of susceptibility artifacts in gradient echo MRI of hyperpolarized 3He gas.

    abstract::The effects of macroscopic background field gradients upon 2D gradient echo images of inhaled (3)He in the human lung were investigated at 1.5 T. Effective compensation of in-slice signal loss in (3)He gradient echo images was then demonstrated using a multiple acquisition interleaved single gradient echo sequence. Th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10549

    authors: Wild JM,Fichele S,Woodhouse N,Paley MN,Swift A,Kasuboski L,van Beek EJ

    更新日期:2003-08-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • Magnitude image CSPAMM reconstruction (MICSR).

    abstract::Image reconstruction of tagged cardiac MR images using complementary spatial modulation of magnetization (CSPAMM) requires the subtraction of two complex datasets to remove the untagged signal. Although the resultant images typically have sharper and more persistent tags than images formed without complementary taggin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10523

    authors: NessAiver M,Prince JL

    更新日期:2003-08-01 00:00:00

  • The effect of reconstruction and acquisition parameters for GRAPPA-based parallel imaging on the image quality.

    abstract::Parallel imaging based on generalized autocalibrating partially parallel acquisitions is widely used in the clinical routine. To date, no detailed analysis has been presented describing the dependence of the image quality on the reconstruction and acquisition parameters such as the number of autocalibration signal (AC...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22803

    authors: Bauer S,Markl M,Honal M,Jung BA

    更新日期:2011-08-01 00:00:00

  • Quantitative magnetization transfer imaging in human brain at 3 T via selective inversion recovery.

    abstract::Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons-including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools k(mf) . This study describes the first implementation of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22928

    authors: Dortch RD,Li K,Gochberg DF,Welch EB,Dula AN,Tamhane AA,Gore JC,Smith SA

    更新日期:2011-11-01 00:00:00

  • Simultaneous quantification of T2 and T'2 using a combined gradient echo-spin echo sequence at ultrahigh field.

    abstract::Measuring T(2) at 7.0 T is not trivial due to RF inhomogeneity effects, however, gradient echo sampling of a spin echo is insensitive to RF pulse errors, does not suffer from significant distortions, and allows T'(2) and T(2) to be estimated simultaneously. Gradient echo sampling of a spin echo results are relatively ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22522

    authors: Cox EF,Gowland PA

    更新日期:2010-11-01 00:00:00

  • Fast measurement of relaxation times by steady-state free precession of 129Xe in carrier agents for hyperpolarized noble gases.

    abstract::Hyperpolarized gases ((129)Xe and (3)He) are being used increasingly in both MRI and NMR spectroscopy studies. However, it has been shown that carrier agents are required to preserve the long relaxation times of gases in biological fluids. Optimized gas transport can be achieved through controlled T(1) and T(2) measur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10476

    authors: Oregioni A,Parizel N,de Sousa PL,Grucker D

    更新日期:2003-06-01 00:00:00

  • Assessing transneuronal dysfunction utilizing manganese-enhanced MRI (MEMRI).

    abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21648

    authors: Serrano F,Deshazer M,Smith KD,Ananta JS,Wilson LJ,Pautler RG

    更新日期:2008-07-01 00:00:00

  • Fast group matching for MR fingerprinting reconstruction.

    abstract:PURPOSE:MR fingerprinting (MRF) is a technique for quantitative tissue mapping using pseudorandom measurements. To estimate tissue properties such as T1 , T2 , proton density, and B0 , the rapidly acquired data are compared against a large dictionary of Bloch simulations. This matching process can be a very computation...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25439

    authors: Cauley SF,Setsompop K,Ma D,Jiang Y,Ye H,Adalsteinsson E,Griswold MA,Wald LL

    更新日期:2015-08-01 00:00:00

  • A single acquisition localization technique.

    abstract::A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030221

    authors: Karczmar GS,Matson GB,Weiner MW

    更新日期:1986-04-01 00:00:00

  • Apparent diffusion of water, ions, and small molecules in the Xenopus oocyte is consistent with Brownian displacement.

    abstract::The incoherent displacement of water in living tissues is of considerable interest because of the widespread use of diffusion-weighted MRI, for which image contrast is based on the water apparent diffusion coefficient (ADC). It has been hypothesized that the decrease in water ADC associated with brain injury is primar...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10181

    authors: Sehy JV,Ackerman JJ,Neil JJ

    更新日期:2002-07-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • Out-and-in spiral spectroscopic imaging in rat brain at 7 T.

    abstract::With standard spectroscopic imaging, high spatial resolution is achieved at the price of a large number of phase-encoding steps, leading to long acquisition times. Fast spatial encoding methods reduce the minimum total acquisition time. In this article, a k-space scanning scheme using a continuous series of growing an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10622

    authors: Hiba B,Faure B,Lamalle L,Décorps M,Ziegler A

    更新日期:2003-12-01 00:00:00

  • Identification of different lipid phases and calcium phosphate deposits in human carotid artery plaques by MAS NMR spectroscopy.

    abstract::Accumulation of lipids in atherosclerotic plaques causes progressive narrowing of the arterial lumen, often followed by thrombosis and ischemia. Currently several different methods, most requiring disruption of the plaque, are used to study the physical properties of lipids accumulated in plaques, and lipid compositio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390204

    authors: Guo W,Morrisett JD,Lawrie GM,DeBakey ME,Hamilton JA

    更新日期:1998-02-01 00:00:00

  • A versatile multinuclear probe designed for in vivo NMR spectroscopy: applications to subcutaneous human tumors in mice.

    abstract::We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060102

    authors: Lyon RC,Tschudin RG,Daly PF,Cohen JS

    更新日期:1988-01-01 00:00:00