Out-and-in spiral spectroscopic imaging in rat brain at 7 T.

Abstract:

:With standard spectroscopic imaging, high spatial resolution is achieved at the price of a large number of phase-encoding steps, leading to long acquisition times. Fast spatial encoding methods reduce the minimum total acquisition time. In this article, a k-space scanning scheme using a continuous series of growing and shrinking, or "out-and-in," spiral trajectories is implemented and the feasibility of spiral spectroscopic imaging for animal models at high B(0) field is demonstrated. This method was applied to rat brain at 7 T. With a voxel size of about 8.7 microl (as calculated from the point-spread function), a 30 x 30 matrix, and a spectral bandwidth of 11 kHz, the minimum scan time was 9 min 20 sec for a signal-to-noise ratio of 7.1 measured on the N-acetylaspartate peak.

journal_name

Magn Reson Med

authors

Hiba B,Faure B,Lamalle L,Décorps M,Ziegler A

doi

10.1002/mrm.10622

subject

Has Abstract

pub_date

2003-12-01 00:00:00

pages

1127-33

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

50

pub_type

杂志文章
  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • In vivo validation of MR pulse pressure measurement in an aortic flow model: preliminary results.

    abstract::MR imaging experiments were conducted to investigate the feasibility of estimating vascular pulse pressure waveforms from measurements of blood flow rates and vessel cross-sectional area. Blood flow waveforms were measured in the aorta's of three 25-30-kg pigs at multiple imaging sections using phase-contrast velocity...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380209

    authors: Urchuk SN,Fremes SE,Plewes DB

    更新日期:1997-08-01 00:00:00

  • The impact of the relaxivity definition on the quantitative measurement of glycosaminoglycans in cartilage by the MRI dGEMRIC method.

    abstract::The relaxivities (R-values) of the gadolinium diethylene triamine pentaacetic acid (Gd(DTPA)2-) ions in a series of skim-milk solutions at 0-40% milk concentrations were measured using NMR spectroscopy. The R-value was found to be approximately linearly proportional to the concentration of the solid component in the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22169

    authors: Zheng S,Xia Y

    更新日期:2010-01-01 00:00:00

  • Adaptive self-calibrating iterative GRAPPA reconstruction.

    abstract::Parallel magnetic resonance imaging in k-space such as generalized auto-calibrating partially parallel acquisition exploits spatial correlation among neighboring signals over multiple coils in calibration to estimate missing signals in reconstruction. It is often challenging to achieve accurate calibration information...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23188

    authors: Park S,Park J

    更新日期:2012-06-01 00:00:00

  • On the use of Bayesian probability theory for analysis of exponential decay data: an example taken from intravoxel incoherent motion experiments.

    abstract::Traditionally, the method of nonlinear least squares (NLLS) analysis has been used to estimate the parameters obtained from exponential decay data. In this study, we evaluated the use of Bayesian probability theory to analyze such data; specifically, that resulting from intravoxel incoherent motion NMR experiments. An...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290510

    authors: Neil JJ,Bretthorst GL

    更新日期:1993-05-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • A semiautomatic method for rapid segmentation of velocity-encoded myocardial magnetic resonance imaging data.

    abstract:PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26486

    authors: Espe EKS,Skårdal K,Aronsen JM,Zhang L,Sjaastad I

    更新日期:2017-09-01 00:00:00

  • The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip.

    abstract::Radiofrequency induced pacemaker lead tip heating is one of the main reasons magnetic resonance imaging (MRI) is contraindicated for patients with pacemakers. The objective of this work was to evaluate the dependence of pacemaker lead tip heating during MRI scanning on the electrical conductivity of the medium surroun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23235

    authors: Langman DA,Goldberg IB,Judy J,Paul Finn J,Ennis DB

    更新日期:2012-08-01 00:00:00

  • Quantitative susceptibility mapping detects abnormalities in cartilage canals in a goat model of preclinical osteochondritis dissecans.

    abstract:PURPOSE:To use quantitative susceptibility mapping (QSM) to investigate changes in cartilage canals in the distal femur of juvenile goats after their surgical transection. METHODS:Chondronecrosis was surgically induced in the right medial femoral condyles of four 4-day-old goats. Both the operated and control knees we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26214

    authors: Wang L,Nissi MJ,Toth F,Johnson CP,Garwood M,Carlson CS,Ellermann J

    更新日期:2017-03-01 00:00:00

  • Time-domain combination of MR spectroscopy data acquired using phased-array coils.

    abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20244

    authors: Brown MA

    更新日期:2004-11-01 00:00:00

  • Model-based mapping of fat unsaturation and chain length by chemical shift imaging--phantom validation and in vivo feasibility.

    abstract::Knowledge about the triglyceride (fat) (1)H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length, unsatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24196

    authors: Berglund J,Ahlström H,Kullberg J

    更新日期:2012-12-01 00:00:00

  • Water-suppressed one-dimensional 1H NMR spectroscopic imaging of myocardial metabolites in vivo.

    abstract::Excitation by conventional B1 pulses in surface coil chemical-shift imaging experiments yields resonance intensities that vary greatly with position. B1-compensated semi-selective pulses overcome much of this problem. These pulses are employed for excitation and refocusing in 1H NMR spectroscopic localization in the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250118

    authors: Balschi JA,Hetherington HP,Pohost GM

    更新日期:1992-05-01 00:00:00

  • MR microscopy of lung airways with hyperpolarized 3He.

    abstract::A technique using hyperpolarized (HP) 3He to image the small airways of the lung by using moderate flip angles and a short scanning period during early inspiration is demonstrated. Flip angles (alpha) ranging from 10-90 degrees were used in guinea pig experiments with scanning during the entire inspiration period. A s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390113

    authors: Chen XJ,Chawla MS,Hedlund LW,Möller HE,MacFall JR,Johnson GA

    更新日期:1998-01-01 00:00:00

  • Estimating T1 from multichannel variable flip angle SPGR sequences.

    abstract::Quantitative estimation of T1 is a challenging but important task inherent to many clinical applications. The most commonly used paradigm for estimating T1 in vivo involves performing a sequence of spoiled gradient-recalled echo acquisitions at different flip angles, followed by fitting of an exponential model to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24401

    authors: Trzasko JD,Mostardi PM,Riederer SJ,Manduca A

    更新日期:2013-06-01 00:00:00

  • Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

    abstract::A novel linear parameterization for the variable flip angle method for longitudinal relaxation time T(1) quantification from spoiled steady state MRI is derived from the half angle tangent transform, τ, of the flip angle. Plotting the signal S at coordinates x=Sτ and y=S/τ, respectively, establishes a line that render...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22849

    authors: Helms G,Dathe H,Weiskopf N,Dechent P

    更新日期:2011-09-01 00:00:00

  • Single-shot localized echo-planar imaging (STEAM-EPI) at 4.7 tesla.

    abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140225

    authors: Turner R,von Kienlin M,Moonen CT,van Zijl PC

    更新日期:1990-05-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Comparison of diffusion- and T2-weighted MRI for the early detection of cerebral ischemia and reperfusion in rats.

    abstract::The sensitivity of diffusion-weighted MRI was compared to that of T2-weighted MRI following temporary middle cerebral artery occlusion (MCA-O) for 33 min followed by 4 h of reperfusion in rats. Diffusion-weighted spin-echo images using strong gradients (b value of 1413 s/mm2) demonstrated a significant increase in sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180106

    authors: Mintorovitch J,Moseley ME,Chileuitt L,Shimizu H,Cohen Y,Weinstein PR

    更新日期:1991-03-01 00:00:00

  • Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    abstract:PURPOSE:Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left vent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26312

    authors: Huelnhagen T,Hezel F,Serradas Duarte T,Pohlmann A,Oezerdem C,Flemming B,Seeliger E,Prothmann M,Schulz-Menger J,Niendorf T

    更新日期:2017-06-01 00:00:00

  • T2 of endotoxin lung injury with and without methylprednisolone treatment.

    abstract::NMR relaxation times (T1 and T2) and the water content (WC) of in vitro rat lungs were measured during the course of endotoxin lung injury in rats. Measurements of normal lungs, untreated endotoxin-injured lungs, and endotoxin-injured lungs treated with methylprednisolone (MPSL) were compared. The untreated endotoxin ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150204

    authors: Shioya S,Haida M,Tsuji C,Ono Y,Miyairi A,Fukuzaki M,Ohta Y,Yamabayashi H

    更新日期:1990-08-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    abstract:PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25546

    authors: Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

    更新日期:2015-12-01 00:00:00

  • Polymetallic macromolecules are potential contrast agents of improved efficiency.

    abstract::The commercial synthetic homopolypeptide polyaspartate (average MW = 30,000, approximately 220 monomers) in solution quantitatively binds up to 40 mol Gd3+ ions per mole of polyaspartate. The water proton relaxivity of the solutions is far higher than that of clinically used or commonly investigated gadolinium(III) co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310109

    authors: Cavagna F,Luchinat C,Scozzafava A,Xia Z

    更新日期:1994-01-01 00:00:00

  • In vivo dynamic MRI tracking of rat T-cells labeled with superparamagnetic iron-oxide particles.

    abstract::Dynamic MRI tracking of rat T-cells in vivo is performed in rat testicles after labeling isolated rat T-cells in vitro with superparamagnetic dextran-coated iron-oxide particles, BMS180549. Tissue inflammation induced by the local injection of the calcium ionophore, A23187, is used to attract labeled T-cells. Gradient...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330209

    authors: Yeh TC,Zhang W,Ildstad ST,Ho C

    更新日期:1995-02-01 00:00:00

  • Chemical shift-induced phase errors in phase-contrast MRI.

    abstract::Phase-contrast magnetic resonance imaging is subject to numerous sources of error, which decrease clinical confidence in the reported measures. This work outlines how stationary perivascular fat can impart a significant chemical shift induced phase-contrast magnetic resonance imaging measurement error using computatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24262

    authors: Middione MJ,Ennis DB

    更新日期:2013-02-01 00:00:00

  • Tracer kinetic modeling in myocardial perfusion quantification using MRI.

    abstract:PURPOSE:To investigate and compare several quantification methods of myocardial perfusion measurements, paying special attention to the relation between the techniques and the required measurement duration. METHODS:Seven patients underwent contrast-enhanced rest and stress cardiac perfusion measurements at 3T. Three s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,随机对照试验

    doi:10.1002/mrm.25212

    authors: Schwab F,Ingrisch M,Marcus R,Bamberg F,Hildebrandt K,Adrion C,Gliemi C,Nikolaou K,Reiser M,Theisen D

    更新日期:2015-03-01 00:00:00

  • Dynamic oxygen-enhanced MRI reflects diffusing capacity of the lung.

    abstract::The purpose of this study was to demonstrate the feasibility of dynamic oxygen-enhanced MRI in a clinical setting. We hypothesized that dynamic oxygen enhancement can reflect the regional diffusing capacity of the lung. Ten patients with pulmonary emphysema and seven healthy volunteers were examined with a respiratory...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10168

    authors: Ohno Y,Hatabu H,Takenaka D,Van Cauteren M,Fujii M,Sugimura K

    更新日期:2002-06-01 00:00:00

  • x-f Choice: reconstruction of undersampled dynamic MRI by data-driven alias rejection applied to contrast-enhanced angiography.

    abstract::A technique for reconstructing dynamic undersampled MRI data, termed "x-f choice," was developed and applied to dynamic contrast-enhanced MR angiography (DCE-MRA). Regular undersampling in k-t space (a hybrid of k-space and time) creates aliasing in the conjugate x-f space that must be resolved. When regions in the ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21008

    authors: Malik SJ,Schmitz S,O'Regan D,Larkman DJ,Hajnal JV

    更新日期:2006-10-01 00:00:00

  • Counter rotating current local coils for high-resolution magnetic resonance imaging.

    abstract::A type of local coil (or surface coil) for magnetic resonance imaging and spectroscopy is described in which two circular loops of the same diameter are disposed axially with respect to each other and in which counter rotating currents (CRC) are supported in the two loops. This type of coil has been used for localized...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030412

    authors: Froncisz W,Jesmanowicz A,Kneeland JB,Hyde JS

    更新日期:1986-08-01 00:00:00