Tracer kinetic modeling in myocardial perfusion quantification using MRI.

Abstract:

PURPOSE:To investigate and compare several quantification methods of myocardial perfusion measurements, paying special attention to the relation between the techniques and the required measurement duration. METHODS:Seven patients underwent contrast-enhanced rest and stress cardiac perfusion measurements at 3T. Three slices were acquired in each patient and were divided into 16 segments, leading to 112 rest and stress data curves, which were analyzed using various tracer kinetic models as well as a model-free deconvolution. Plasma flow, plasma volume, and myocardial perfusion reserve were analyzed for the complete acquisition as well as for the first pass data only. RESULTS:Deconvolution analysis yielded stable results for both rest and stress analysis, while Fermi and one compartment models agree well for first pass data (rest measurements only) and prolonged data acquisition (stress measurements only). More complex models do not yield satisfactory results for the short measurement times investigated in this study. CONCLUSIONS:When performing MRI-based quantification of myocardial perfusion, care must be taken that the method used is appropriate for the time frame under investigation. When a numerical deconvolution is used instead of tracer kinetic models, more stable results are obtained.

journal_name

Magn Reson Med

authors

Schwab F,Ingrisch M,Marcus R,Bamberg F,Hildebrandt K,Adrion C,Gliemi C,Nikolaou K,Reiser M,Theisen D

doi

10.1002/mrm.25212

subject

Has Abstract

pub_date

2015-03-01 00:00:00

pages

1206-15

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

73

pub_type

杂志文章,随机对照试验
  • Strategy for lipid suppression in lactate imaging using STIR-DQCT: a study of hypoxic-ischemic brain injury.

    abstract::In vivo lactate detection using gradient enhanced double quantum coherence transfer (DQCT) was significantly improved by addition of short-time-inversion-recovery (STIR). Phantom studies demonstrated lipid suppression down to the background noise level with 33% loss of lactate signal. In vivo studies using a rabbit mo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400416

    authors: Nakai T,Rhine WD,Okada T,Stevenson DK,Spielman DM

    更新日期:1998-10-01 00:00:00

  • Cerebral glucose is detectable by localized proton NMR spectroscopy in normal rat brain in vivo.

    abstract::This contribution reports the first direct and noninvasive observation of cerebral glucose in normal anesthetized rats (n = 16) using short-echo-time localized proton NMR spectroscopy (2.35 T, STEAM, TR = 6000 ms, TE = 20 ms, 125 microliters). In addition to resonances from N-acetyl aspartate (NAA), glutamate, total c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190243

    authors: Gyngell ML,Michaelis T,Hörstermann D,Bruhn H,Hänicke W,Merboldt KD,Frahm J

    更新日期:1991-06-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations.

    abstract:PURPOSE:MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element-based simulations were performed to explore this pos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26333

    authors: McGrath DM,Ravikumar N,Beltrachini L,Wilkinson ID,Frangi AF,Taylor ZA

    更新日期:2017-07-01 00:00:00

  • Machine learning RF shimming: Prediction by iteratively projected ridge regression.

    abstract:PURPOSE:To obviate online slice-by-slice RF shim optimization and reduce B1+ mapping requirements for patient-specific RF shimming in high-field magnetic resonance imaging. THEORY AND METHODS:RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient-specific, SAR-efficient RF shims with a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27192

    authors: Ianni JD,Cao Z,Grissom WA

    更新日期:2018-11-01 00:00:00

  • Potential degradation in image quality due to selective averaging of phase-encoding lines in Fourier transform MRI.

    abstract::The properties of the image noise for selective averaging of phase-encoding lines have been investigated. For a given acquisition time, selective averaging results in a signal-to-noise ratio penalty compared to averaging all lines equally. In addition, selective averaging yields a non uniform distribution of noise cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190115

    authors: Mugler JP 3rd

    更新日期:1991-05-01 00:00:00

  • Lactate imaging with Hadamard-encoded slice-selective multiple quantum coherence chemical-shift imaging.

    abstract::The ability to generate in vivo maps of lactate may have significant diagnostic utility in staging and treatment planning of a wide variety of cancers. The double selective multiple quantum filter technique (SelMQC) has been shown to be effective for nonlocalized detection of lactate with little or no interference fro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21659

    authors: Pickup S,Lee SC,Mancuso A,Glickson JD

    更新日期:2008-08-01 00:00:00

  • Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

    abstract::Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20221

    authors: Jochimsen TH,Norris DG,Mildner T,Möller HE

    更新日期:2004-10-01 00:00:00

  • RAPID--a new method for fast imaging using a single slice of Z-magnetization.

    abstract::A single slice of z-magnetization is used to generate high-speed images. The slice selection step is achieved using two sin-sinc pulses. This procedure eliminates the need for continual slice gradient reversal, a requirement for the FLASH technique. The RAPID imaging method has less inherent T1 and/or T2 dependence th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050213

    authors: Brooks WM,Brereton IM,Doddrell DM

    更新日期:1987-08-01 00:00:00

  • Parallel reconstruction using null operations.

    abstract::A novel iterative k-space data-driven technique, namely parallel reconstruction using null operations (PRUNO), is presented for parallel imaging reconstruction. In PRUNO, both data calibration and image reconstruction are formulated into linear algebra problems based on a generalized system model. An optimal data cali...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22899

    authors: Zhang J,Liu C,Moseley ME

    更新日期:2011-11-01 00:00:00

  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • A 3 T sodium and proton composite array breast coil.

    abstract:PURPOSE:The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3 T. The secondary objective was to create acceptable proton images with the sodium phased array in place. METHODS:A novel composite array for combined proton/sodium 3 T breast MRI is compared with a c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24860

    authors: Kaggie JD,Hadley JR,Badal J,Campbell JR,Park DJ,Parker DL,Morrell G,Newbould RD,Wood AF,Bangerter NK

    更新日期:2014-06-01 00:00:00

  • Combined functional and viability cardiac MR imaging in a single breathhold.

    abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21390

    authors: Ibrahim el-SH,Stuber M,Kraitchman DL,Weiss RG,Osman NF

    更新日期:2007-10-01 00:00:00

  • Measurements of T(1) -relaxation in ex vivo prostate tissue at 132 μT.

    abstract::The proton T(1) was measured at 132 μT in ex vivo prostate tissue specimens from radical prostatectomies of 35 patients with prostate cancer. Each patient provided two specimens. The NMR and MRI measurements involved proton repolarization, a field of typically 150 mT and detection of the 5.6-kHz signal with a supercon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24177

    authors: Busch S,Hatridge M,Mößle M,Myers W,Wong T,Mück M,Chew K,Kuchinsky K,Simko J,Clarke J

    更新日期:2012-04-01 00:00:00

  • The effect of gadolinium DTPA on tissue water compartments in slow- and fast-twitch rabbit muscles.

    abstract::Proton T2 relaxation and its biexponential components have been determined in rabbit skeletal muscle in the presence and absence of GdDTPA. The effect of GdDTPA, which distributes only in the extracellular space, was greatest in the longer-relaxing T2 component (T22). A 27% reduction in T22 was measured for slow-twitc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110205

    authors: Adzamli IK,Jolesz FA,Bleier AR,Mulkern RV,Sandor T

    更新日期:1989-08-01 00:00:00

  • Continuously moving table MRI with golden angle radial sampling.

    abstract:PURPOSE:Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole-body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arb...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25531

    authors: Sengupta S,Smith DS,Welch EB

    更新日期:2015-12-01 00:00:00

  • The analytic theory, optimization, and performance of transparent pulses.

    abstract::Transparent pulses are defined by the property of having no net effect on stationary spins, while selectively nutating and dephasing flowing spins. They are derived from the inverse scattering transform, a nonlinear extension of the inverse Fourier transform. They can be used as presaturation pulses to suppress select...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240212

    authors: Buonocore MH

    更新日期:1992-04-01 00:00:00

  • Evaluation of coils for imaging histological slides: signal-to-noise ratio and filling factor.

    abstract:PURPOSE:To investigate the relative gain in sensitivity of five histology coils designed in-house to accommodate tissue sections of various sizes and compare with commercial mouse head coils. METHODS:The coil set was tailored to house tissue sections ranging from 5 to1000 µm encased in either glass slides or coverslip...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24841

    authors: Hoang DM,Voura EB,Zhang C,Fakri-Bouchet L,Wadghiri YZ

    更新日期:2014-05-01 00:00:00

  • In vivo measurements of bone marrow cellularity using volume-localized proton NMR spectroscopy.

    abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190108

    authors: Ballon D,Jakubowski A,Gabrilove J,Graham MC,Zakowski M,Sheridan C,Koutcher JA

    更新日期:1991-05-01 00:00:00

  • Respiration based steering for high intensity focused ultrasound liver ablation.

    abstract:PURPOSE:Respiratory motion makes hepatic ablation using high intensity focused ultrasound (HIFO) challenging. Previous HIFU liver treatment had required apnea induced during general anesthesia. We describe and test a system that allows treatment of the liver in the presence of breathing motion. METHODS:Mapping a signa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24695

    authors: Holbrook AB,Ghanouni P,Santos JM,Dumoulin C,Medan Y,Pauly KB

    更新日期:2014-02-01 00:00:00

  • Iterative reweighted linear least squares for accurate, fast, and robust estimation of diffusion magnetic resonance parameters.

    abstract:PURPOSE:Diffusion-weighted magnetic resonance imaging suffers from physiological noise, such as artifacts caused by motion or system instabilities. Therefore, there is a need for robust diffusion parameter estimation techniques. In the past, several techniques have been proposed, including RESTORE and iRESTORE (Chang e...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25351

    authors: Collier Q,Veraart J,Jeurissen B,den Dekker AJ,Sijbers J

    更新日期:2015-06-01 00:00:00

  • Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

    abstract::This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24362

    authors: Kaiser J,Bradford R,Johnson K,Wieben O,Thelen DG

    更新日期:2013-05-01 00:00:00

  • Macromolecule and water magnetization exchange modeling in articular cartilage.

    abstract::Magnetization exchange effects between the matrix macromolecules (e. g., collagen and proteoglycan) and water were examined in normal, deuterated, and proteoglycan-depleted articular cartilage. Relaxation results (T(2), T(1rho), and T(1)) suggested that a four-site exchange scheme provided an accurate model for articu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200012)44:6<840::aid-mrm4>3.0.co

    authors: Lattanzio PJ,Marshall KW,Damyanovich AZ,Peemoeller H

    更新日期:2000-12-01 00:00:00

  • Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

    abstract::The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3

    authors: de Zwart JA,Vimeux FC,Delalande C,Canioni P,Moonen CT

    更新日期:1999-07-01 00:00:00

  • TOWERS: T-One with Enhanced Robustness and Speed.

    abstract:PURPOSE:A new T1 mapping method is proposed that is accurate, rapid, and robust to motion. Considering these features, the method is dubbed "T-One with Enhanced Robustness and Speed (TOWERS)." METHODS:TOWERS is composed of inversion recovery (IR) and saturation recovery (SR) acquisitions. In the IR acquisitions, a sli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25864

    authors: Eldeniz C,Finsterbusch J,Lin W,An H

    更新日期:2016-07-01 00:00:00

  • Rigid-body motion correction with self-navigation MRI.

    abstract::The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21883

    authors: Mendes J,Kholmovski E,Parker DL

    更新日期:2009-03-01 00:00:00

  • Volumetric analysis of white matter, gray matter, and CSF using fractional volume analysis.

    abstract::Quantitative cerebral tissue volumes may be useful for an objective assessment of pathological changes in brain. Accurate determination of tissue volumes is complicated, however, by the partial volume averaging (PVA) effect. We have, therefore, developed a new pulse sequence that minimizes the PVA through the use of i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390614

    authors: Bedell BJ,Narayana PA

    更新日期:1998-06-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • High-resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy-matched voxel sizes.

    abstract::In a systematic study on the interdependence of linewidth, signal-to-noise ratio (SNR), and spatial resolution in 3D proton spectroscopic imaging ((1)H-SI) at 3 T, we demonstrate reduced linewidths with increased spatial resolution due to reduced magnetic inhomogeneity within the brain. High-precision quantitative dat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10377

    authors: Gruber S,Mlynárik V,Moser E

    更新日期:2003-02-01 00:00:00

  • A versatile multinuclear probe designed for in vivo NMR spectroscopy: applications to subcutaneous human tumors in mice.

    abstract::We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoid...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060102

    authors: Lyon RC,Tschudin RG,Daly PF,Cohen JS

    更新日期:1988-01-01 00:00:00