Apparent diffusion of water, ions, and small molecules in the Xenopus oocyte is consistent with Brownian displacement.

Abstract:

:The incoherent displacement of water in living tissues is of considerable interest because of the widespread use of diffusion-weighted MRI, for which image contrast is based on the water apparent diffusion coefficient (ADC). It has been hypothesized that the decrease in water ADC associated with brain injury is primarily due to a reduction in the ADC of water in the intracellular space. Xenopus oocytes permit direct measurement of ADC values for intracellular molecules, thereby providing insight into the nature of intracellular motion. In this study, the measured ADC values of small molecules and ions are shown to be primarily size-dependent, indicating that intracellular water motion in the oocyte is mainly Brownian displacement with little or no role for cytoplasmic streaming. Further, intracellular water ADC values show no dependence on diffusion time over a broad range (3.4-100 ms), suggesting that barriers to displacement are finely spaced (< or = 2-3 microm). The water diffusion shows some small anisotropy, suggesting that the cell has structure, giving water displacement a directional preference. The calculated intracellular apparent viscosity, which reflects the combined effects of barriers to motion, intermolecular binding, and fluid phase viscosity was 2.07 +/- 0.09 cP.

journal_name

Magn Reson Med

authors

Sehy JV,Ackerman JJ,Neil JJ

doi

10.1002/mrm.10181

subject

Has Abstract

pub_date

2002-07-01 00:00:00

pages

42-51

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

48

pub_type

杂志文章
  • Design and construction of an innovative brain phantom prototype for MRI.

    abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27464

    authors: Altermatt A,Santini F,Deligianni X,Magon S,Sprenger T,Kappos L,Cattin P,Wuerfel J,Gaetano L

    更新日期:2019-02-01 00:00:00

  • The uncommon longitudinal relaxation dispersion of human brain white matter.

    abstract::Human brain white matter exhibits an uncommonly strong dispersion of 1/T1 at high fields. An additional relaxation pathway via the myelin lipids, which are not directly visible to medical NMR due to their fast T2 decay, is proposed. Relaxation dispersion data are successfully analyzed on the basis of this model. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090319

    authors: Fischer HW,Van Haverbeke Y,Schmitz-Feuerhake I,Muller RN

    更新日期:1989-03-01 00:00:00

  • Pharmacological MRI of the choroid and retina: blood flow and BOLD responses during nitroprusside infusion.

    abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24112

    authors: Shih YY,Li G,Muir ER,De La Garza BH,Kiel JW,Duong TQ

    更新日期:2012-10-01 00:00:00

  • Infimal convolution of total generalized variation functionals for dynamic MRI.

    abstract:PURPOSE:To accelerate dynamic MR applications using infimal convolution of total generalized variation functionals (ICTGV) as spatio-temporal regularization for image reconstruction. THEORY AND METHODS:ICTGV comprises a new image prior tailored to dynamic data that achieves regularization via optimal local balancing b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26352

    authors: Schloegl M,Holler M,Schwarzl A,Bredies K,Stollberger R

    更新日期:2017-07-01 00:00:00

  • Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.

    abstract::Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22737

    authors: Wang W,Nguyen NM,Yablonskiy DA,Sukstanskii AL,Osmanagic E,Atkinson JJ,Conradi MS,Woods JC

    更新日期:2011-03-01 00:00:00

  • Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation.

    abstract::In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd(3+) ions further increases the achievable solid-state polarization. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24207

    authors: Gordon JW,Fain SB,Rowland IJ

    更新日期:2012-12-01 00:00:00

  • Direct projective time-of-flight NMR angiography within 4s.

    abstract::To enhance contrast between flow and static tissue, NMR projective angiographic methods usually require data subtraction, or alternatively the application of special data processing routines such as the "maximum intensity projection" algorithm. We have successfully developed a direct projection method which yields suf...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180213

    authors: Matsuda T,Doyle M,Pohost GM

    更新日期:1991-04-01 00:00:00

  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • Unambiguous assignment of the H3S and H3R deuterations of cerebral (2-13C) glutamate by 13C NMR at 18.8 Tesla.

    abstract::We used high-field (13)C NMR (18.8 T) to assign unambiguously the isotopic shifts induced by the deuterium substitutions of the H3(proR) and H3(proS) hydrogens of (2-(13)C) glutamate in extracts of the brain from deuterated animals. Monodeuterated H3R or H3S glutamate diastereoisomers were produced stereospecifically ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22277

    authors: Rodrigues TB,Violante IR,Cerdán S

    更新日期:2010-04-01 00:00:00

  • Transverse relaxivity of iron oxide nanocrystals clustered in nanoemulsions: Experiment and theory.

    abstract:PURPOSE:To compare experimental transverse relaxivities of iron oxide nanocrystals (IONC) as a function of clustering and magnetic field strength with different theoretical model predictions. THEORY AND METHODS:Well-defined IONC clusters in nanoemulsions (NEs) of which both size and IONC loading could be judiciously t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25465

    authors: Hak S,Goa PE,Stenmark S,Bjerkholt FF,Haraldseth O

    更新日期:2015-09-01 00:00:00

  • Total liver fat quantification using three-dimensional respiratory self-navigated MRI sequence.

    abstract:PURPOSE:MRI can produce quantitative liver fat fraction (FF) maps noninvasively, which can help to improve diagnoses of fatty liver diseases. However, most sequences acquire several two-dimensional (2D) slices during one or more breath-holds, which may be difficult for patients with limited breath-holding capacity. A w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26028

    authors: Arboleda C,Aguirre-Reyes D,García MP,Tejos C,Muñoz L,Miquel JF,Irarrazaval P,Andia ME,Uribe S

    更新日期:2016-11-01 00:00:00

  • A 3 T sodium and proton composite array breast coil.

    abstract:PURPOSE:The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3 T. The secondary objective was to create acceptable proton images with the sodium phased array in place. METHODS:A novel composite array for combined proton/sodium 3 T breast MRI is compared with a c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24860

    authors: Kaggie JD,Hadley JR,Badal J,Campbell JR,Park DJ,Parker DL,Morrell G,Newbould RD,Wood AF,Bangerter NK

    更新日期:2014-06-01 00:00:00

  • Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI.

    abstract::Fluid-attenuated inversion recovery (FLAIR) images obtained during the administration of supplemental oxygen demonstrate a hyperintense signal within the cerebrospinal fluid (CSF) that is likely caused by T1 changes induced by paramagnetic molecular oxygen. Previous studies demonstrated a linear relationship between t...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20546

    authors: Zaharchuk G,Martin AJ,Rosenthal G,Manley GT,Dillon WP

    更新日期:2005-07-01 00:00:00

  • Regional and temporal variations in tissue sodium concentration during the acute stroke phase.

    abstract::A technique for noninvasively quantifying the concentration of sodium ((23) Na) ions was applied to the study of ischemic stroke. (23) Na-magnetic resonance imaging techniques have shown considerable potential for measuring subtle changes in ischemic tissue, although studies to date have suffered primarily from poor s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23031

    authors: Wetterling F,Gallagher L,Macrae IM,Junge S,Fagan AJ

    更新日期:2012-03-01 00:00:00

  • Transient decrease in tumor oxygenation after intravenous administration of pyruvate.

    abstract::MRI using hyperpolarized (13) C-labeled pyruvate is a promising tool to biochemically profile tumors and monitor their response to therapy. This technique requires injection of pyruvate into tumor-bearing animals. Pyruvate is an endogenous entity but the influence of exogenously injected bolus doses of pyruvate on tum...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23065

    authors: Saito K,Matsumoto S,Devasahayam N,Subramanian S,Munasinghe JP,Morris HD,Lizak MJ,Ardenkjaer-Larsen JH,Mitchell JB,Krishna MC

    更新日期:2012-03-01 00:00:00

  • Echo-planar spin-echo and inversion pulses.

    abstract::The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290609

    authors: Pauly J,Spielman D,Macovski A

    更新日期:1993-06-01 00:00:00

  • Field camera measurements of gradient and shim impulse responses using frequency sweeps.

    abstract:PURPOSE:Applications of dynamic shimming require high field fidelity, and characterizing the shim field dynamics is therefore necessary. Modeling the system as linear and time-invariant, the purpose of this work was to measure the impulse response function with optimal sensitivity. THEORY AND METHODS:Frequency-swept p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24934

    authors: Vannesjo SJ,Dietrich BE,Pavan M,Brunner DO,Wilm BJ,Barmet C,Pruessmann KP

    更新日期:2014-08-01 00:00:00

  • Characterization of white matter alterations in phenylketonuria by magnetic resonance relaxometry and diffusion tensor imaging.

    abstract::A multimodal MR study including relaxometry, diffusion tensor imaging (DTI), and MR spectroscopy was performed on patients with classical phenylketonuria (PKU) and matched controls, to improve our understanding of white matter (WM) lesions. Relaxometry yields information on myelin loss or malformation and may substant...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21422

    authors: Vermathen P,Robert-Tissot L,Pietz J,Lutz T,Boesch C,Kreis R

    更新日期:2007-12-01 00:00:00

  • Evaluation of MRI resolution affecting trabecular bone parameters: determination of acceptable resolution.

    abstract::The objective of this study is to evaluate the effect of MR image resolution on trabecular bone parameters and to determine the acceptable resolution that can be accurately analyzed to assess structural parameters. Ten distal femoral condyle specimens of 1 × 1 × 1 cm(3) were scanned with a 4.7-T Bruker BioSpec MRI sca...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22984

    authors: Kim N,Lee JG,Song Y,Kim HJ,S Yeom J,Cho G

    更新日期:2012-01-01 00:00:00

  • Unifying linear prior-information-driven methods for accelerated image acquisition.

    abstract::In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1242

    authors: Tsao J,Behnia B,Webb AG

    更新日期:2001-10-01 00:00:00

  • Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout.

    abstract::Multislice MR images obtained using a fast spin-echo (FSE) readout are strongly affected by magnetization transfer (MT) effects, which will cause a decrease in the observed longitudinal relaxation times for tissues with a large bound water component. This is pertinent for FSE-based inversion-recovery (IR) sequences, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21338

    authors: Meara SJ,Barker GJ

    更新日期:2007-10-01 00:00:00

  • Differential effect of isoflurane, medetomidine, and urethane on BOLD responses to acute levo-tetrahydropalmatine in the rat.

    abstract::Levo-tetrahydropalmatine (l-THP) has shown significant promise in preclinical and clinical studies to treat drug addiction. Pharmacological MRI methods can elucidate the regional cerebral effects of l-THP, but there are potential confounds from the use of general anesthesia. To investigate the possible anesthetic-drug...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23243

    authors: Liu X,Li R,Yang Z,Hudetz AG,Li SJ

    更新日期:2012-08-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • Simultaneous measurement of intracellular and extracellular oxygen concentrations using a nitroxide-liposome system.

    abstract::The concentration of oxygen within cells is important in many physiological and pathological processes, but such oxygen-dependent phenomena are generally studied as a function of the concentration of extracellular oxygen, due to a lack of suitable methods. Electron parmamagnetic resonance (EPR) oximetric techniques of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290105

    authors: Glockner JF,Norby SW,Swartz HM

    更新日期:1993-01-01 00:00:00

  • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

    abstract::The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20440

    authors: Steger TR,White RA,Jackson EF

    更新日期:2005-04-01 00:00:00

  • Experimental approaches to image localized human 31P NMR spectroscopy.

    abstract::Experimental procedures for obtaining localized 31P NMR spectra of humans by means of the ISIS sequence are discussed in detail. The technique is optimized for use with volume coils and with surface coils in order to measure localized 31P NMR spectra of different tissues and organs. Selective frequency-modulated (FM) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110102

    authors: Luyten PR,Groen JP,Vermeulen JW,den Hollander JA

    更新日期:1989-07-01 00:00:00

  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • Development and validation of 3D MP-SSFP to enable MRI in inhomogeneous magnetic fields.

    abstract:PURPOSE:We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity. METHODS:T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To valida...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28469

    authors: Kobayashi N,Parkinson B,Idiyatullin D,Adriany G,Theilenberg S,Juchem C,Garwood M

    更新日期:2021-02-01 00:00:00

  • Quantitative magnetization transfer imaging in human brain at 3 T via selective inversion recovery.

    abstract::Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons-including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools k(mf) . This study describes the first implementation of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22928

    authors: Dortch RD,Li K,Gochberg DF,Welch EB,Dula AN,Tamhane AA,Gore JC,Smith SA

    更新日期:2011-11-01 00:00:00

  • A ranking of diffusion MRI compartment models with in vivo human brain data.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) microstructure imaging provides a unique noninvasive probe into tissue microstructure. The technique relies on biophysically motivated mathematical models, relating microscopic tissue features to the magnetic resonance (MR) signal. This work aims to determine which com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25080

    authors: Ferizi U,Schneider T,Panagiotaki E,Nedjati-Gilani G,Zhang H,Wheeler-Kingshott CA,Alexander DC

    更新日期:2014-12-01 00:00:00