Fast and accurate calculation of myocardial T1 and T2 values using deep learning Bloch equation simulations (DeepBLESS).

Abstract:

PURPOSE:To propose and evaluate a deep learning model for rapid and accurate calculation of myocardial T1 /T2 values based on a previously proposed Bloch equation simulation with slice profile correction (BLESSPC) method. METHODS:Deep learning Bloch equation simulations (DeepBLESS) models are proposed for rapid and accurate T1 estimation for the MOLLI T1 mapping sequence with balanced SSFP readouts and T1 /T2 estimation for a radial simultaneous T1 and T2 mapping (radial T1 -T2 ) sequence. The DeepBLESS models were trained separately based on simulated radial T1 -T2 and MOLLI data, respectively. The DeepBLESS T1 -T2 estimation accuracy was evaluated based on simulated data with different noise levels. The DeepBLESS model was compared with BLESSPC in simulation, phantom, and in vivo studies for the MOLLI sequence at 1.5 T and radial T1 -T2 sequence at 3 T. RESULTS:After DeepBLESS was trained, in phantom studies, DeepBLESS and BLESSPC achieved similar accuracy and precision in T1 -T2 estimations for both MOLLI and radial T1 -T2 (P > .05). For in vivo, DeepBLESS and BLESSPC generated similar myocardial T1 /T2 values for radial T1 -T2 at 3 T (T1 : 1366 ± 31 ms for both methods, P > .05; T2 : 37.4 ms ± 0.9 ms for both methods, P > .05), and similar myocardial T1 values for the MOLLI sequence at 1.5 T (1044 ± 20 ms for both methods, P > .05). DeepBLESS generated a T1 /T2 map in less than 1 second. CONCLUSION:The DeepBLESS model offers an almost instantaneous approach for estimating accurate T1 /T2 values, replacing BLESSPC for both MOLLI and radial T1 -T2 sequences, and is promising for multiparametric mapping in cardiac MRI.

journal_name

Magn Reson Med

authors

Shao J,Ghodrati V,Nguyen KL,Hu P

doi

10.1002/mrm.28321

subject

Has Abstract

pub_date

2020-11-01 00:00:00

pages

2831-2845

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

84

pub_type

杂志文章
  • Metabolic assessment of a migraine model using relaxation-enhanced 1 H spectroscopy at ultrahigh field.

    abstract:PURPOSE:This study evaluates biochemical imbalances in a rat model that reflects dysfunctional pathways in migraine. The high sensitivity and spectral dispersion available to 1 H MRS at 21.1 T expands metabolic profiling in this migraine model to include lactate (Lac), taurine (Tau), aspartate, and Gly-a mixture of gly...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26811

    authors: Abad N,Rosenberg JT,Roussel T,Grice DC,Harrington MG,Grant SC

    更新日期:2018-03-01 00:00:00

  • Determination of regional brain temperature using proton magnetic resonance spectroscopy to assess brain-body temperature differences in healthy human subjects.

    abstract::Proton magnetic resonance spectroscopy ((1)H MRS) was used to determine brain temperature in healthy volunteers. Partially water-suppressed (1)H MRS data sets were acquired at 3T from four different gray matter (GM)/white matter (WM) volumes. Brain temperatures were determined from the chemical-shift difference betwee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21100

    authors: Childs C,Hiltunen Y,Vidyasagar R,Kauppinen RA

    更新日期:2007-01-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • Tumor 31P NMR pH measurements in vivo: a comparison of inorganic phosphate and intracellular 2-deoxyglucose-6-phosphate as pHnmr indicators in murine radiation-induced fibrosarcoma-1.

    abstract::Uncertainty regarding the intracellular/extracellular distribution of inorganic phosphate (P(i)) in tumors has raised concerns that pH calculated from the tumor P(i) chemical shift may not accurately represent the intracellular pH (pHin). This issue was addressed in subcutaneously transplanted murine radiation induced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360508

    authors: Soto GE,Zhu Z,Evelhoch JL,Ackerman JJ

    更新日期:1996-11-01 00:00:00

  • Assessment of myocardial viability in rats: Evaluation of a new method using superparamagnetic iron oxide nanoparticles and Gd-DOTA at high magnetic field.

    abstract::The aim of this study was to detect salvageable peri-infarction myocardium by MRI in rats after infarction, using with a double contrast agent (CA) protocol at 7 Tesla. Intravascular superparamagnetic iron oxide (SPIO) nanoparticles and an extracellular paramagnetic CA (Gd-DOTA) were used to characterize the peri-infa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20210

    authors: Chapon C,Lemaire L,Franconi F,Marescaux L,Legras P,Denizot B,Le Jeune JJ

    更新日期:2004-10-01 00:00:00

  • NOE enhancements and T1 relaxation times of phosphorylated metabolites in human calf muscle at 1.5 Tesla.

    abstract::Nuclear Overhauser effect (NOE) enhancements and relaxation times of 31P metabolites in human calf were measured in 12 volunteers (4 men and 8 women) at 1.5 T using a dual tuned four-ring birdcage. The NOE enhancements of inorganic phosphate (Pi), phosphocreatine (PCr), gamma-, alpha-, and beta-nucleoside triphosphate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330316

    authors: Brown TR,Stoyanova R,Greenberg T,Srinivasan R,Murphy-Boesch J

    更新日期:1995-03-01 00:00:00

  • Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

    abstract:PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffus...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26969

    authors: Deelchand DK,Auerbach EJ,Marjańska M

    更新日期:2018-06-01 00:00:00

  • The development of a pH-sensitive contrast agent for NMR 1H imaging.

    abstract::Fe(III)meso-tetra(4-sulfonatophenyl)porphine (Fe-TPPS4) has been investigated as a potential pH-sensitive nuclear magnetic resonance (NMR) proton image contrast agent. Relaxation rates (1/T1 and 1/T2) of water protons were measured as a function of pH and concentration of Fe-TPPS4 in phosphate-buffered isotonic saline...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050313

    authors: Helpern JA,Curtis JC,Hearshen D,Smith MB,Welch KM

    更新日期:1987-09-01 00:00:00

  • Artifacts and signal loss due to flow in the presence of B(o) inhomogeneity.

    abstract::An in vitro study was performed to investigate the effects of B(o) inhomogeneity on magnetic resonance images of flow. Controlled inhomogeneity gradients (Gi) were applied and the magnitude of the artifacts produced was quantified for different echo delay times (TE). Both steady and pulsatile flows were examined. In t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350116

    authors: Drangova M,Pelc NJ

    更新日期:1996-01-01 00:00:00

  • Molecular imaging of angiogenic therapy in peripheral vascular disease with alphanubeta3-integrin-targeted nanoparticles.

    abstract::Noninvasive molecular imaging of angiogenesis could play a critical role in the clinical management of peripheral vascular disease patients. The alpha(nu)beta(3)-integrin, a well-established biomarker of neovascular proliferation, is an ideal target for molecular imaging of angiogenesis. This study investigates whethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22447

    authors: Winter PM,Caruthers SD,Allen JS,Cai K,Williams TA,Lanza GM,Wickline SA

    更新日期:2010-08-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla.

    abstract::MRI has become an important tool to noninvasively assess global and regional cardiac function, infarct size, or myocardial blood flow in surgically or genetically modified mouse models of human heart disease. Constraints on scan time due to sensitivity to general anesthesia in hemodynamically compromised mice frequent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22605

    authors: Schneider JE,Lanz T,Barnes H,Stork LA,Bohl S,Lygate CA,Ordidge RJ,Neubauer S

    更新日期:2011-01-01 00:00:00

  • Spin-lattice relaxation time measurements using hybrid CSI--phantom study.

    abstract::The spin-lattice relaxation time T1 of multicomponent tissues is often determined by fitting relaxation data to monoexponential functions. This process can lead to large errors in the relaxation time. We describe a procedure using chemical-shift imaging (CSI) which separates the NMR signal into water and lipid compone...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130307

    authors: Hornak JP,Smith AC,Szumowski J

    更新日期:1990-03-01 00:00:00

  • 3D-multi-spectral T2 mapping near metal implants.

    abstract:PURPOSE:Due to host-mediated adverse reaction to metallic debris, there is an increasing need for noninvasive assessment of the soft tissue surrounding large joint arthroplasties. Quantitative T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27744

    authors: Bhave S,Koff MF,Sivaram Kaushik S,Potter HG,Koch KM

    更新日期:2019-08-01 00:00:00

  • Fast mapping of myocardial blood flow with MR first-pass perfusion imaging.

    abstract::Accurate and fast quantification of myocardial blood flow (MBF) with MR first-pass perfusion imaging techniques on a pixel-by-pixel basis remains difficult due to relatively long calculation times and noise-sensitive algorithms. In this study, Zierler's central volume principle was used to develop an algorithm for the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21559

    authors: Goldstein TA,Jerosch-Herold M,Misselwitz B,Zhang H,Gropler RJ,Zheng J

    更新日期:2008-06-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Quantification of fluid changes in rat leg joints with adjuvant arthritis by a one-dimensional magnetic resonance imaging experiment.

    abstract::A simple and reliable method for quantifying the fluid content and characterizing the tissue T2 relaxation properties of animal extremities has been devised. This one-dimensional magnetic resonance imaging experiment, applied to the adjuvant arthritis model in rats, provides a useful, noninvasive monitor of the course...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150208

    authors: Borah B,Szeverenyi NM

    更新日期:1990-08-01 00:00:00

  • Rapid six-degree-of-freedom motion detection using prerotated baseline spherical navigator echoes.

    abstract::A new spherical navigator echo (SNAV) registration technique is presented. This technique starts by collecting a set of SNAV templates at a reference position. These templates are acquired by rotating the gradient system to result in rotation angles that uniformly cover a predefined range of rotation. The rotation ang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22629

    authors: Liu J,Drangova M

    更新日期:2011-02-01 00:00:00

  • Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: preliminary results in 12 patients.

    abstract::The purpose of this study was to determine the value of a blood-pool contrast media (NC100150, Nycomed Imaging (now Amersham Health) Oslo, Norway) for evaluation of venous thrombosis of the deep veins of the pelvis and lower extremities. Twelve patients were prospectively evaluated with conventional X-ray venography (...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1002/mrm.10607

    authors: Aschauer M,Deutschmann HA,Stollberger R,Hausegger KA,Obernosterer A,Schöllnast H,Ebner F

    更新日期:2003-11-01 00:00:00

  • Accelerated 3D T2 mapping with dictionary-based matching for prostate imaging.

    abstract:PURPOSE:To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS:3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27540

    authors: Roccia E,Vidya Shankar R,Neji R,Cruz G,Munoz C,Botnar R,Goh V,Prieto C,Dregely I

    更新日期:2019-03-01 00:00:00

  • Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.

    abstract::Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varyin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20928

    authors: Kim DH,Spielman DM

    更新日期:2006-07-01 00:00:00

  • RACER-GRASP: Respiratory-weighted, aortic contrast enhancement-guided and coil-unstreaking golden-angle radial sparse MRI.

    abstract:PURPOSE:To develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27002

    authors: Feng L,Huang C,Shanbhogue K,Sodickson DK,Chandarana H,Otazo R

    更新日期:2018-07-01 00:00:00

  • A framework for optimization-based design of motion encoding in magnetic resonance elastography.

    abstract:PURPOSE:In conventional three-dimensional magnetic resonance elastography, motion encoding gradients (MEGs) synchronized to a mechanical excitation are applied separately in each direction to encode tissue displacement generated by the corresponding waves. This requires long acquisition times that introduce errors due ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25280

    authors: Nir G,Sahebjavaher RS,Sinkus R,Salcudean SE

    更新日期:2015-04-01 00:00:00

  • Volume-localized measurement of oxygen extraction fraction in the brain using MRI.

    abstract:PURPOSE:T2 -relaxation-under-spin-tagging (TRUST) is an MR technique for the non-invasive assessment of whole-brain cerebral oxygen extraction fraction (OEF), through measurement of the venous blood T2 relaxation time in the sagittal sinus. A key limitation of TRUST, however, is the lack of spatial specificity of the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27823

    authors: O'Brien C,Okell TW,Chiew M,Jezzard P

    更新日期:2019-10-01 00:00:00

  • A computer simulation of nuclear magnetic resonance imaging.

    abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030302

    authors: Summers RM,Axel L,Israel S

    更新日期:1986-06-01 00:00:00

  • Template-based field map prediction for rapid whole brain B0 shimming.

    abstract:PURPOSE:In typical MRI protocols, time is spent acquiring a field map to calculate the shim settings for best image quality. We propose a fast template-based field map prediction method that yields near-optimal shims without measuring the field. METHODS:The template-based prediction method uses prior knowledge of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27020

    authors: Shi Y,Vannesjo SJ,Miller KL,Clare S

    更新日期:2018-07-01 00:00:00

  • SUPER: A blockwise curve-fitting method for accelerating MR parametric mapping with fast reconstruction.

    abstract:PURPOSE:To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction. METHODS:SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27662

    authors: Hu C,Peters DC

    更新日期:2019-06-01 00:00:00

  • Unifying linear prior-information-driven methods for accelerated image acquisition.

    abstract::In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1242

    authors: Tsao J,Behnia B,Webb AG

    更新日期:2001-10-01 00:00:00

  • Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats.

    abstract::When using tracer kinetic modeling to analyze dynamic contrast-enhanced MRI (DCE-MRI) it is necessary to identify an appropriate arterial input function (AIF). The measured AIF is often poorly sampled in both clinical and preclinical MR systems due to the initial rapid increase in contrast agent concentration and the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21959

    authors: McGrath DM,Bradley DP,Tessier JL,Lacey T,Taylor CJ,Parker GJ

    更新日期:2009-05-01 00:00:00

  • RF heating measurement using MR thermometry and field monitoring: Methodological considerations and first in vivo results.

    abstract:PURPOSE:A MR thermometry (MRT) method with field monitoring is proposed to improve the measurement of small temperature variations induced in brain MRI exams. METHODS:MR thermometry experiments were performed at 7 Tesla with concurrent field monitoring and RF heating. Images were reconstructed with nominal k-space tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28501

    authors: Le Ster C,Mauconduit F,Mirkes C,Bottlaender M,Boumezbeur F,Djemai B,Vignaud A,Boulant N

    更新日期:2021-03-01 00:00:00