Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo.

Abstract:

:Brain water proton (1H2O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5-mm midventricular axial slice was sampled using a modified Look-Locker technique with 1.5 mm in-plane resolution, and 32 time points post-adiabatic inversion. The results confirmed that for most brain tissues, T1 values increased by more than a factor of 3 between 0.2T and 7T, and over this range were well fitted by T1 (s)=0.583(B0)0.382, T1(s)=0.857(B0)0.376, and T1(s)=1.35(B0)0.340 for white matter (WM), internal GM, and blood 1H2O, respectively. The ventricular cerebrospinal fluid (CSF) 1H2O T1 value did not change with B0, and its average value (standard deviation (SD)) across subjects and magnetic fields was 4.3 (+/-0.2) s. The tissue 1/T1 values at each field were well correlated with the macromolecular mass fraction, and to a lesser extent tissue iron content. The field-dependent increases in 1H2O T1 values more than offset the well-known decrease in typical MRI contrast reagent (CR) relaxivity, and simulations predict that this leads to lower CR concentration detection thresholds with increased magnetic field.

journal_name

Magn Reson Med

authors

Rooney WD,Johnson G,Li X,Cohen ER,Kim SG,Ugurbil K,Springer CS Jr

doi

10.1002/mrm.21122

subject

Has Abstract

pub_date

2007-02-01 00:00:00

pages

308-18

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

57

pub_type

杂志文章
  • Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH.

    abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360402

    authors: Hatabu H,Gaa J,Kim D,Li W,Prasad PV,Edelman RR

    更新日期:1996-10-01 00:00:00

  • In vivo MRI of fresh stored osteochondral allograft transplantation with delayed gadolinium-enhanced MRI of cartilage: protocol considerations and recommendations.

    abstract::The protocol for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) was adapted for the evaluation of transplanted osteochondral allograft cartilage. Eight patients with focal grade 4 cartilage defects of the femoral condyle were treated with single cylindrical osteochondral allografts. At 1 and 2 years, dGEMRIC i...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24419

    authors: Durkan MG,Szumowski J,Brown DS,Foss EW,Crawford DC

    更新日期:2013-06-01 00:00:00

  • Human whole-blood (1)H2O longitudinal relaxation with normal and high-relaxivity contrast reagents: influence of trans-cell-membrane water exchange.

    abstract:PURPOSE:Accurate characterization of contrast reagent (CR) longitudinal relaxivity in whole blood is required to predict arterial signal intensity in contrast-enhanced MR angiography (CE-MRA). This study measured the longitudinal relaxation rate constants (R1 ) over a concentration range for non-protein-binding and pro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25064

    authors: Wilson GJ,Woods M,Springer CS Jr,Bastawrous S,Bhargava P,Maki JH

    更新日期:2014-12-01 00:00:00

  • Phase contrast MRI with flow compensation view sharing.

    abstract:PURPOSE:To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy. METHODS:PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25133

    authors: Wang D,Shao J,Rapacchi S,Middione MJ,Ennis DB,Hu P

    更新日期:2015-02-01 00:00:00

  • Low peak power multiband spokes pulses for B1 (+) inhomogeneity-compensated simultaneous multislice excitation in high field MRI.

    abstract:PURPOSE:To design low peak and integrated power simultaneous multislice excitation radiofrequency pulses with transmit field inhomogeneity compensation in high field MRI. THEORY AND METHODS:The "interleaved greedy and local optimization" algorithm for small-tip-angle spokes pulses is extended to design multiband (MB) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25455

    authors: Sharma A,Bammer R,Stenger VA,Grissom WA

    更新日期:2015-09-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenization.

    abstract:PURPOSE:To develop a new parallel transmit (pTx) pulse design for simultaneous multiband (MB) excitation in order to tackle simultaneously the problems of transmit B1 (B1+) inhomogeneity and total radiofrequency (RF) power, so as to allow for optimal RF excitation when using MB pulses for slice acceleration for high an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24828

    authors: Wu X,Schmitter S,Auerbach EJ,Moeller S,Uğurbil K,Van de Moortele PF

    更新日期:2013-09-01 00:00:00

  • Single-shot localized echo-planar imaging (STEAM-EPI) at 4.7 tesla.

    abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140225

    authors: Turner R,von Kienlin M,Moonen CT,van Zijl PC

    更新日期:1990-05-01 00:00:00

  • Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic device.

    abstract:PURPOSE:To develop a wideband cardiac perfusion pulse sequence and test whether it is capable of suppressing image artifacts in patients with a cardiac implantable electronic device (CIED), while not exceeding the specific absorption rate (SAR) limit (2.0 W/kg). METHODS:A wideband perfusion pulse sequence was develope...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27458

    authors: Hong K,Collins JD,Knight BP,Carr JC,Lee DC,Kim D

    更新日期:2019-02-01 00:00:00

  • Determination of regional brain temperature using proton magnetic resonance spectroscopy to assess brain-body temperature differences in healthy human subjects.

    abstract::Proton magnetic resonance spectroscopy ((1)H MRS) was used to determine brain temperature in healthy volunteers. Partially water-suppressed (1)H MRS data sets were acquired at 3T from four different gray matter (GM)/white matter (WM) volumes. Brain temperatures were determined from the chemical-shift difference betwee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21100

    authors: Childs C,Hiltunen Y,Vidyasagar R,Kauppinen RA

    更新日期:2007-01-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • Quantification of the extraction fraction for gadopentetate across breast cancer capillaries.

    abstract::To quantify the extraction fraction, E, for gadopentetate across tumor capillaries, R3230 adenocarcinomas were implanted in the mammary fat pads of seven rats. The value of E was determined by using a two-compartment tissue model in which the endothelial transfer coefficient, K(PS) (ml x min(-1) x cc(-1) of tissue), w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400406

    authors: Daldrup HE,Shames DM,Husseini W,Wendland MF,Okuhata Y,Brasch RC

    更新日期:1998-10-01 00:00:00

  • Reduction of B1 sensitivity in selective single-slab 3D turbo spin echo imaging with very long echo trains.

    abstract::Single-slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is vulnerable to image degradation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22070

    authors: Park J,Mugler JP 3rd,Hughes T

    更新日期:2009-10-01 00:00:00

  • The sensitivity of low flip angle RARE imaging.

    abstract::It is demonstrated that the stability of the Carr-Purcell-Meiboom-Gill (CPMG) sequence reflects the existence of a steady state solution to the Bloch equations in the absence of T2 and T1 decay. The steady state theory is then used to evaluate the performance of low flip angle RARE imaging sequences with both constant...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370206

    authors: Alsop DC

    更新日期:1997-02-01 00:00:00

  • Quantitative framework for prospective motion correction evaluation.

    abstract:PURPOSE:Establishing a framework to evaluate performances of prospective motion correction (PMC) MRI considering motion variability between MRI scans. METHODS:A framework was developed to obtain quantitative comparisons between different motion correction setups, considering that varying intrinsic motion patterns betw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25580

    authors: Pannetier NA,Stavrinos T,Ng P,Herbst M,Zaitsev M,Young K,Matson G,Schuff N

    更新日期:2016-02-01 00:00:00

  • Measurement of Gd-DTPA dialysis clearance rates by using a look-locker imaging technique.

    abstract::The exponential clearance rate constant, (kappa), and filtration fraction (FF) have been measured for dialysis of Gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) (Magnevist, Berlex, Wayne, NJ) solutions by using a Look-Locker imaging technique under conditions of flow. The measured values of kappa for the Baxt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360412

    authors: Niendorf ER,Santyr GE,Brazy PC,Grist TM

    更新日期:1996-10-01 00:00:00

  • Self-calibrated correlation imaging with k-space variant correlation functions.

    abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26818

    authors: Li Y,Edalati M,Du X,Wang H,Cao JJ

    更新日期:2018-03-01 00:00:00

  • Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

    abstract::A novel linear parameterization for the variable flip angle method for longitudinal relaxation time T(1) quantification from spoiled steady state MRI is derived from the half angle tangent transform, τ, of the flip angle. Plotting the signal S at coordinates x=Sτ and y=S/τ, respectively, establishes a line that render...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22849

    authors: Helms G,Dathe H,Weiskopf N,Dechent P

    更新日期:2011-09-01 00:00:00

  • Effects of acute normovolemic hemodilution on T2*-weighted images of rat brain.

    abstract::Acute normovolemic hemodilution (HD) was induced in anesthetized rats to assess the effect of changes in hematocrit (Hct) on signal intensity in T2*-weighted magnetic resonance (MR) images. Other relevant physiological parameters were maintained invariant. Two degrees of HD were induced: mild (Hct reduced from 42.6+/-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400611

    authors: Lin W,Paczynski RP,Celik A,Hsu CY,Powers WJ

    更新日期:1998-12-01 00:00:00

  • Conversion of arterial input functions for dual pharmacokinetic modeling using Gd-DTPA/MRI and 18F-FDG/PET.

    abstract::Reaching the full potential of magnetic resonance imaging (MRI)-positron emission tomography (PET) dual modality systems requires new methodologies in quantitative image analyses. In this study, methods are proposed to convert an arterial input function (AIF) derived from gadolinium-diethylenetriaminepentaacetic acid ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24318

    authors: Poulin E,Lebel R,Croteau E,Blanchette M,Tremblay L,Lecomte R,Bentourkia M,Lepage M

    更新日期:2013-03-01 00:00:00

  • Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    abstract:PURPOSE:We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. METHODS:The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25799

    authors: Ye H,Ma D,Jiang Y,Cauley SF,Du Y,Wald LL,Griswold MA,Setsompop K

    更新日期:2016-05-01 00:00:00

  • Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

    abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21095

    authors: Gabr RE,Aksit P,Bottomley PA,Youssef AB,Kadah YM

    更新日期:2006-12-01 00:00:00

  • Sensitivity regularization of the Cramér-Rao lower bound to minimize B1 nonuniformity effects in quantitative magnetization transfer imaging.

    abstract:PURPOSE:To develop and validate a regularization approach of optimizing B1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F). METHODS:An expression describing the impact of B1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27337

    authors: Boudreau M,Pike GB

    更新日期:2018-12-01 00:00:00

  • In vivo 13C magnetic resonance spectroscopy of human brain on a clinical 3 T scanner using [2-13C]glucose infusion and low-power stochastic decoupling.

    abstract::This study presents the detection of [2-(13)C]glucose metabolism in the carboxylic/amide region in the human brain, and demonstrates that the cerebral metabolism of [2-(13)C]glucose can be studied in human subjects in the presence of severe hardware constraints of widely available 3 T clinical scanners and with low-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22044

    authors: Li S,Zhang Y,Wang S,Yang J,Ferraris Araneta M,Farris A,Johnson C,Fox S,Innis R,Shen J

    更新日期:2009-09-01 00:00:00

  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • A single acquisition localization technique.

    abstract::A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030221

    authors: Karczmar GS,Matson GB,Weiner MW

    更新日期:1986-04-01 00:00:00

  • High resolution quantitative relaxation and diffusion MRI of three different experimental brain tumors in rat.

    abstract::The potential of quantitative parameter images of the relaxation times T1 and T2, the proton density rho and the apparent diffusion coefficient (ADC) to characterize three different experimental rat brain tumors (F98 glioma, RN6 Schwannoma, and E376 neuroblastoma) was studied. All parameter values, as determined in hi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340608

    authors: Eis M,Els T,Hoehn-Berlage M

    更新日期:1995-12-01 00:00:00

  • Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    abstract::The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22189

    authors: Tieng QM,Vegh V,Brereton IM

    更新日期:2010-01-01 00:00:00

  • Echo-planar spin-echo and inversion pulses.

    abstract::The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290609

    authors: Pauly J,Spielman D,Macovski A

    更新日期:1993-06-01 00:00:00

  • B factor dependence of the temporal characteristics of brain activation using dynamic apparent diffusion coefficient contrast.

    abstract::Functional MRI studies to date have been generally performed using the blood oxygenation level dependent (BOLD) contrast mechanism. Recently, it has been proposed that dynamic change in the apparent diffusion coefficient (ADC), measured using intravoxel incoherent motion (IVIM) weighting, can be used as a robust funct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20293

    authors: Harshbarger TB,Song AW

    更新日期:2004-12-01 00:00:00