Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times.

Abstract:

PURPOSE:This assesses the potential of measuring lactate in the human brain using three non-editing MRS methods at 7T and compares the accuracy and precision of the methods. METHODS:1 H MRS data were measured in the right dorsolateral prefrontal cortex using a semi-adiabatic spin-echo full-intensity acquired localized sequence with three different protocols: (I) TE = 16 ms, (II) TE = 110 ms, and (III) TE = 16 ms, TI = 300 ms. T1 and T2 relaxation times of lactate were also measured. Simulated spectra were generated for three protocols with known concentrations, using a range of spectral linewidths and SNRs to assess the effect of data quality on the measurement precision and accuracy. RESULTS:Lactate was quantified in all three protocols with mean Cramér-Rao lower bound of 8% (I), 13% (II), and 7% (III). The T1 and T2 relaxation times of lactate were 1.9 ± 0.2 s and 94 ± 13 ms, respectively. Simulations predicted a spectral linewidth-associated underestimation of lactate measurement. Simulations, phantom and in vivo results showed that protocol II was most affected by this underestimation. In addition, the estimation error was insensitive to a broad range of spectral linewidth with protocol I. Within-session coefficient of variances of lactate were 6.1 ± 7.9% (I), 22.3 ± 12.3% (II), and 5.1 ± 5.4% (III), respectively. CONCLUSION:We conclude that protocols I and III have the potential to measure lactate at 7T with good reproducibility, whereas the measurement accuracy and precision depend on spectral linewidth and SNR, respectively. Moreover, simulation is valuable for the optimization of measurement protocols in future study design and the correction for measurement bias.

journal_name

Magn Reson Med

authors

Dehghani M,Do KQ,Magistretti P,Xin L

doi

10.1002/mrm.28066

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

1895-1908

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

83

pub_type

杂志文章
  • Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH.

    abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360402

    authors: Hatabu H,Gaa J,Kim D,Li W,Prasad PV,Edelman RR

    更新日期:1996-10-01 00:00:00

  • Sensitivity and source of amine-proton exchange and amide-proton transfer magnetic resonance imaging in cerebral ischemia.

    abstract:PURPOSE:Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS:We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24639

    authors: Zong X,Wang P,Kim SG,Jin T

    更新日期:2014-01-01 00:00:00

  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Direction-averaged diffusion-weighted MRI signal using different axisymmetric B-tensor encoding schemes.

    abstract:PURPOSE:It has been shown, theoretically and in vivo, that using the Stejskal-Tanner pulsed-gradient, or linear tensor encoding (LTE), and in tissue exhibiting a "stick-like" diffusion geometry, the direction-averaged diffusion-weighted MRI signal at high b-values ( ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28191

    authors: Afzali M,Aja-Fernández S,Jones DK

    更新日期:2020-09-01 00:00:00

  • The MR tomograph as a sound generator: fMRI tool for the investigation of the auditory cortex.

    abstract::An automatic fMRI protocol for the investigation of the human auditory cortex has been developed. For the activation of the auditory system, the scanner noise itself is the source of sound. Rapid switching of B0 gradients allows the generation of tones of defined frequencies and amplitude on a conventional scanner wit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400621

    authors: Bilecen D,Radü EW,Scheffler K

    更新日期:1998-12-01 00:00:00

  • Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.

    abstract::Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22737

    authors: Wang W,Nguyen NM,Yablonskiy DA,Sukstanskii AL,Osmanagic E,Atkinson JJ,Conradi MS,Woods JC

    更新日期:2011-03-01 00:00:00

  • Improved data reconstruction method for GRAPPA.

    abstract::This paper presents an improved data reconstruction method for generalized autocalibrating partially parallel acquisitions (GRAPPA) using multicolumn multiline interpolation (MCMLI). Both nearest acquired line (ky) neighboring points and column (kx) neighboring points from all components of an array coil were used to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20601

    authors: Wang Z,Wang J,Detre JA

    更新日期:2005-09-01 00:00:00

  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized (3) He MRI.

    abstract:PURPOSE:A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pA O2 ) measurements using (3) He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pA O2 was compared with that of the standard pulmonary func...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24604

    authors: Hamedani H,Kadlecek SJ,Ishii M,Emami K,Kuzma NN,Xin Y,Rossman M,Rizi RR

    更新日期:2013-12-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • Susceptibility mapping in the human brain using threshold-based k-space division.

    abstract::A method for calculating quantitative three-dimensional susceptibility maps from field measurements acquired using gradient echo imaging at high field is presented. This method is based on division of the three-dimensional Fourier transforms of high-pass-filtered field maps by a simple function that is the Fourier tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22334

    authors: Wharton S,Schäfer A,Bowtell R

    更新日期:2010-05-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00

  • Quantitative analysis of the z-spectrum using a numerically simulated look-up table: Application to the healthy human brain at 7T.

    abstract:PURPOSE:To develop a method that fits a multipool model to z-spectra acquired from non-steady state sequences, taking into account the effects of variations in T1 or B1 amplitude and the results estimating the parameters for a four-pool model to describe the z-spectrum from the healthy brain. METHODS:We compared measu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26459

    authors: Geades N,Hunt BAE,Shah SM,Peters A,Mougin OE,Gowland PA

    更新日期:2017-08-01 00:00:00

  • On the calculation of magnetization slice profiles for NMR imaging and in vivo spectroscopy.

    abstract::When developing new techniques for NMR imaging and in vivo spectroscopy it is a major advantage to be able to calculate the magnetization slice profiles, at any point during a pulse sequence in the presence of a field gradient. While this has frequently been done by treating the problem as a number of discrete resonan...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050511

    authors: Bulsing JM,Galloway GJ,Brereton IM,Doddrell DM

    更新日期:1987-11-01 00:00:00

  • MRI relaxation fluctuations in acute reperfused hemorrhagic infarction.

    abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21079

    authors: Foltz WD,Yang Y,Graham JJ,Detsky JS,Wright GA,Dick AJ

    更新日期:2006-12-01 00:00:00

  • Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

    abstract::The experiments reported herein are the first MRI investigations of the orientational dependence of T(2) relaxation in articular cartilage at microscopic resolution over the 360 degrees angular space. For each of six canine cartilage specimens, 48 independent T(2)-weighted proton images were acquired for 12 different ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10216

    authors: Xia Y,Moody JB,Alhadlaq H

    更新日期:2002-09-01 00:00:00

  • Real-time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises.

    abstract:PURPOSE:To develop and test real-time MR elastography for viscoelastic parameter quantification in skeletal muscle during dynamic exercises. METHODS:In 15 healthy participants, 6 groups of lower-leg muscles (tibialis anterior, tibialis posterior, peroneus, extensor digitorum longus, soleus, gastrocnemius) were investi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28095

    authors: Schrank F,Warmuth C,Görner S,Meyer T,Tzschätzsch H,Guo J,Uca YO,Elgeti T,Braun J,Sack I

    更新日期:2020-07-01 00:00:00

  • High resolution hyperpolarized 13 C MRSI using SPICE at 9.4T.

    abstract:PURPOSE:To test the feasibility of using the SPICE (SPectroscopic Imaging by exploiting spatiospectral CorrElation) technique, which uses the partial separability of spectroscopic data, for high resolution hyperpolarized (HP) 13 C spectroscopic imaging. METHODS:Numerical simulations were performed to investigate the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27061

    authors: Lee H,Song JE,Shin J,Joe E,Joo CG,Choi YS,Song HT,Kim DH

    更新日期:2018-08-01 00:00:00

  • Mapping connectomes with diffusion MRI: deterministic or probabilistic tractography?

    abstract:PURPOSE:Human connectomics necessitates high-throughput, whole-brain reconstruction of multiple white matter fiber bundles. Scaling up tractography to meet these high-throughput demands yields new fiber tracking challenges, such as minimizing spurious connections and controlling for gyral biases. The aim of this study ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27471

    authors: Sarwar T,Ramamohanarao K,Zalesky A

    更新日期:2019-02-01 00:00:00

  • SUPER: A blockwise curve-fitting method for accelerating MR parametric mapping with fast reconstruction.

    abstract:PURPOSE:To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction. METHODS:SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27662

    authors: Hu C,Peters DC

    更新日期:2019-06-01 00:00:00

  • Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    abstract::The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10604

    authors: de Vocht F,van-Wendel-de-Joode B,Engels H,Kromhout H

    更新日期:2003-10-01 00:00:00

  • Stream function optimization for gradient coil design.

    abstract::This work presents a method applied to the design of short self-shielded gradient coils of cylindrical geometry. The method uses a hybrid technique that combines the simulated annealing and target field methods to optimize the standard stream functions. The optimized stream functions were parameterized using a few deg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<505::aid-mrm1066>3.0

    authors: Tomasi D

    更新日期:2001-03-01 00:00:00

  • Lactate imaging with Hadamard-encoded slice-selective multiple quantum coherence chemical-shift imaging.

    abstract::The ability to generate in vivo maps of lactate may have significant diagnostic utility in staging and treatment planning of a wide variety of cancers. The double selective multiple quantum filter technique (SelMQC) has been shown to be effective for nonlocalized detection of lactate with little or no interference fro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21659

    authors: Pickup S,Lee SC,Mancuso A,Glickson JD

    更新日期:2008-08-01 00:00:00

  • A computer simulation program for MR imaging: application to RF and static magnetic field imperfections.

    abstract::A computer simulation program capable of demonstrating various artifacts, such as image distortion caused by metallic implants in MR imaging, is presented. The structure of the program allows for the implementation of various imaging situations as long as spins only experience weak interaction, i.e., the Bloch equatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340418

    authors: Olsson MB,Wirestam R,Persson BR

    更新日期:1995-10-01 00:00:00

  • Sensitivity regularization of the Cramér-Rao lower bound to minimize B1 nonuniformity effects in quantitative magnetization transfer imaging.

    abstract:PURPOSE:To develop and validate a regularization approach of optimizing B1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F). METHODS:An expression describing the impact of B1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27337

    authors: Boudreau M,Pike GB

    更新日期:2018-12-01 00:00:00

  • Incorporating dixon multi-echo fat water separation for novel quantitative magnetization transfer of the human optic nerve in vivo.

    abstract:PURPOSE:The optic nerve (ON) represents the sole pathway between the eyes and brain; consequently, diseases of the ON can have dramatic effects on vision. However, quantitative magnetization transfer (qMT) applications in the ON have been limited to ex vivo studies, in part because of the fatty connective tissue that s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26164

    authors: Smith AK,Dortch RD,Dethrage LM,Lyttle BD,Kang H,Welch EB,Smith SA

    更新日期:2017-02-01 00:00:00

  • Optimum flip-angles for exciting NMR with uncertain T1 values.

    abstract::T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence interva...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320120

    authors: Bottomley PA,Ouwerkerk R

    更新日期:1994-07-01 00:00:00

  • A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

    abstract:PURPOSE:We describe a 2 × 6 channel sodium/proton array for knee MRI at 3T. Multielement coil arrays are desirable because of well-known signal-to-noise ratio advantages over volume and single-element coils. However, low tissue-coil coupling that is characteristic of coils operating at low frequency can make the potent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26017

    authors: Brown R,Lakshmanan K,Madelin G,Alon L,Chang G,Sodickson DK,Regatte RR,Wiggins GC

    更新日期:2016-10-01 00:00:00

  • Fast 31P chemical shift imaging using SSFP methods.

    abstract::Steady-state free precession (SSFP) methods have been very successful due to their high signal and short imaging times. These properties make them good candidates for applications that intrinsically suffer from low signal such as low gamma nuclei imaging. A new chemical shift imaging (CSI) technique based on the SSFP ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10279

    authors: Speck O,Scheffler K,Hennig J

    更新日期:2002-10-01 00:00:00