Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI.

Abstract:

:The analysis of abdominal and thoracic dynamic contrast-enhanced MRI is often impaired by artifacts and misregistration caused by physiological motion. Breath-hold is too short to cover long acquisitions. A novel multipurpose reconstruction technique, entitled dynamic contrast-enhanced generalized reconstruction by inversion of coupled systems, is presented. It performs respiratory motion compensation in terms of both motion artefact correction and registration. It comprises motion modeling and contrast-change modeling. The method feeds on physiological signals and x-f space properties of dynamic series to invert a coupled system of linear equations. The unknowns solved for represent the parameters for a linear nonrigid motion model and the parameters for a linear contrast-change model based on B-splines. Performance is demonstrated on myocardial perfusion imaging, on six simulated data sets and six clinical exams. The main purpose consists in removing motion-induced errors from time-intensity curves, thus improving curve analysis and postprocessing in general. This method alleviates postprocessing difficulties in dynamic contrast-enhanced MRI and opens new possibilities for dynamic contrast-enhanced MRI analysis.

journal_name

Magn Reson Med

authors

Filipovic M,Vuissoz PA,Codreanu A,Claudon M,Felblinger J

doi

10.1002/mrm.22644

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

812-22

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

65

pub_type

杂志文章
  • Magnetic resonance angiography with hyperpolarized 129Xe dissolved in a lipid emulsion.

    abstract::Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/- 1 ppm with reference to xenon gas, a spin-lattice relaxation time T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm2

    authors: Möller HE,Chawla MS,Chen XJ,Driehuys B,Hedlund LW,Wheeler CT,Johnson GA

    更新日期:1999-05-01 00:00:00

  • Nuclear magnetic resonance parameters for monitoring coagulation of liver tissue.

    abstract::A new NMR parameter is suggested as a sensitive tool for monitoring thermal coagulation of liver tissue. That parameter is the proton magnetization exchange time (tau(MEX)) between water and the proteins. tau(MEX) was very sensitive to coagulation and insensitive to temperature, therefore representing only damage to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20693

    authors: Carasso D,Eliav U,Navon G

    更新日期:2005-11-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Multinuclear NMR investigations of probe construction materials at 4.7 T.

    abstract::Since background signal from NMR probes can overwhelm the signal from a sample, the NMR analysis of plastics or machinable ceramics is a prerequisite to their use in probe implementations. The contributions from a variety of materials to proton, fluorine, and carbon NMR spectra are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130317

    authors: Babcock EE,Vaughan JT,Lesan B,Nunnally RL

    更新日期:1990-03-01 00:00:00

  • Three-dimensional MRI with independent slab excitation and encoding.

    abstract::Three-dimensional MRI is typically performed with the same orientation for radiofrequency slab excitation and slab select phase encoding. We introduce independent slab excitation and encoding to create a new degree of freedom in three-dimensional MRI, which is the angular relationship between the prescribed excitation...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23043

    authors: Eissa A,Wilman AH

    更新日期:2012-02-01 00:00:00

  • Analysis of the evolution of focal cerebral ischemia in the rat using the eigenimage filter.

    abstract::The eigenimage filter was used to evaluate the results of a MRI study of cerebral ischemia in a rat model. This linear filter segments a desired feature in an image sequence from other features which may interfere with its observation. The animals were imaged temporally, after occlusion of the middle cerebral artery, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260207

    authors: Peck DJ,Spickler EM,Knight RA,Hearshen DO,Windham JP

    更新日期:1992-08-01 00:00:00

  • Localized proton MR spectroscopy of the human kidney in vivo by means of short echo time STEAM sequences.

    abstract::In order to obtain proton magnetic resonance spectra from the normal human kidney in vivo, we employed a STEAM sequence with delay times TE = 10 ms and TM = 30 ms. Signals are attenuated during STEAM sequences by J-coupling effects and by macroscopic movement of the sample. The combination of short echo times and resp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310503

    authors: Dixon RM,Frahm J

    更新日期:1994-05-01 00:00:00

  • Novel RF coil geometry for lower extremity imaging.

    abstract::A receive-only phased-array coil was designed to image the lower extremities. The array consists of four volume coils placed on two cylindrical formers. The coil array has the ability to image both legs simultaneously over a 40 cm longitudinal field of view (FOV). Experiments using phantoms show an increase in signal-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10712

    authors: Brown R,Mareyam A,Reid E,Wang Y

    更新日期:2004-03-01 00:00:00

  • Cardiac tagging with breath-hold cine MRI.

    abstract::A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280214

    authors: McVeigh ER,Atalar E

    更新日期:1992-12-01 00:00:00

  • Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T.

    abstract:PURPOSE:To establish a cardiac signal from scattering matrix or scattering coefficient measurements made on a 7T 8-channel parallel transmit (pTx) system, and to evaluate its use for cardiac gating. METHODS:Measurements of the scattering matrix and scattering coefficients were acquired using a monitoring pulse sequenc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27038

    authors: Jaeschke SHF,Robson MD,Hess AT

    更新日期:2018-08-01 00:00:00

  • Noninvasive in vivo oximetric imaging by radiofrequency FT EPR.

    abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10133

    authors: Subramanian S,Yamada K,Irie A,Murugesan R,Cook JA,Devasahayam N,Van Dam GM,Mitchell JB,Krishna MC

    更新日期:2002-05-01 00:00:00

  • Intensity correction of phased-array surface coil images.

    abstract::Phased-array coils distribute the high signal-to-noise ratio (SNR) performance of their small component surface coils over the larger area covered by the entire array. The inhomogeneous sensitivity profiles of the component surface coils result in images with very high signal near the phased-array and decreased signal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350419

    authors: Murakami JW,Hayes CE,Weinberger E

    更新日期:1996-04-01 00:00:00

  • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla.

    abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21113

    authors: Marliani AF,Clementi V,Albini-Riccioli L,Agati R,Leonardi M

    更新日期:2007-01-01 00:00:00

  • A comparison of static and dynamic ∆B0 mapping methods for correction of CEST MRI in the presence of temporal B0 field variations.

    abstract:PURPOSE:To assess the performance, in the presence of scanner instabilities, of three dynamic correction methods which integrate ∆B0 mapping into the chemical exchange saturation transfer (CEST) measurement and three established static ∆B0 -correction approaches. METHODS:A homogeneous phantom and five healthy voluntee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27750

    authors: Poblador Rodriguez E,Moser P,Dymerska B,Robinson S,Schmitt B,van der Kouwe A,Gruber S,Trattnig S,Bogner W

    更新日期:2019-08-01 00:00:00

  • Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

    abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26826

    authors: Deelchand DK,Auerbach EJ,Kobayashi N,Marjańska M

    更新日期:2018-03-01 00:00:00

  • Doubly tuned local coils for MRI and MRS at 1.5 T.

    abstract::We describe a doubly tuned radiofrequency (RF) local coil probe designed specifically for performing in vivo image-localized spectroscopy. The probe was designed using principles developed in connection with the counter-rotating-current (CRC) and planar-pair loop gap resonators for magnetic resonance imaging (MRI). Th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060303

    authors: Grist TM,Jesmanowicz A,Kneeland JB,Froncisz W,Hyde JS

    更新日期:1988-03-01 00:00:00

  • Reweighted ℓ1 referenceless PRF shift thermometry.

    abstract::Temperature estimation in proton resonance frequency (PRF) shift MR thermometry requires a reference, or pretreatment, phase image that is subtracted from image phase during thermal treatment to yield a phase difference image proportional to temperature change. Referenceless thermometry methods derive a reference phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22502

    authors: Grissom WA,Lustig M,Holbrook AB,Rieke V,Pauly JM,Butts-Pauly K

    更新日期:2010-10-01 00:00:00

  • Effects of the acoustic noise of the gradient systems on fMRI: a study on auditory, motor, and visual cortices.

    abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390224

    authors: Cho ZH,Chung SC,Lim DW,Wong EK

    更新日期:1998-02-01 00:00:00

  • Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

    abstract::A novel radio-frequency (RF) pulse design algorithm is presented that generates fast slice-selective excitation pulses that mitigate B+1 inhomogeneity present in the human brain at high field. The method is provided an estimate of the B+1 field in an axial slice of the brain and then optimizes the placement of sinc-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21585

    authors: Zelinski AC,Wald LL,Setsompop K,Alagappan V,Gagoski BA,Goyal VK,Adalsteinsson E

    更新日期:2008-06-01 00:00:00

  • Electromagnetic actuator for generating variably oriented shear waves in MR elastography.

    abstract::Magnetic resonance elastography (MRE) is a recently developed technique for determining the mechanical properties of biological tissue. In dynamic MRE, electromagnetic units (actuators) are widely used to generate shear waves in tissue. These actuators exploit the interaction between the static magnetic field B(0) and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10479

    authors: Braun J,Braun K,Sack I

    更新日期:2003-07-01 00:00:00

  • Per-subject characterization of bolus width in pulsed arterial spin labeling using bolus turbo sampling.

    abstract::Quantification of cerebral blood flow using QUIPSSII pulsed arterial spin labeling requires that the QUIPSS saturation delay TI1 is shorter than the natural temporal bolus width. Yet the duration of the bolus of tagged spins entering the region of interest varies during vasoactive stimuli such as gaseous challenges or...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24412

    authors: Villien M,Chipon E,Troprès I,Bouvier J,Cantin S,Chechin D,Le Bas JF,Krainik A,Warnking JM

    更新日期:2013-06-01 00:00:00

  • On the origin of paramagnetic inhomogeneity effects in blood.

    abstract::Hydrogen, sodium, and fluorine (added F-) NMR spectra of venous and oxygenated blood were measured. The fluorine resonance was seen as a single peak in both samples, and all three resonances exhibited the same deoxy-oxy shift. Because F- exchanges slowly across the red cell membrane, and because sodium is 95% extracel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120210

    authors: Brooks RA,Brunetti A,Alger JR,Di Chiro G

    更新日期:1989-11-01 00:00:00

  • Optimum flip-angles for exciting NMR with uncertain T1 values.

    abstract::T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence interva...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320120

    authors: Bottomley PA,Ouwerkerk R

    更新日期:1994-07-01 00:00:00

  • Hypercarbia-induced changes in cerebral blood volume in the cat: a 1H MRI and intravascular contrast agent study.

    abstract::Cerebral blood volume changes with arterial carbon dioxide were monitored by proton T1-weighted MR images following administration of the intravascular contrast agent Gd-DTPA labeled with human serum albumin. Without MR contrast, no significant image intensity changes were observed with PaCO2. Following contrast, regi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230104

    authors: Moseley ME,Chew WM,White DL,Kucharczyk J,Litt L,Derugin N,Dupon J,Brasch RC,Norman D

    更新日期:1992-01-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • Fast diffusion imaging with high angular resolution.

    abstract:PURPOSE:High angular resolution diffusion imaging (HARDI) is a well-established method to help reveal the architecture of nerve bundles, but long scan times and geometric distortions inherent to echo planar imaging (EPI) have limited its integration into clinical protocols. METHODS:A fast imaging method is proposed he...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26163

    authors: Chao TC,Chiou JG,Maier SE,Madore B

    更新日期:2017-02-01 00:00:00

  • Reproducibility study of whole-brain 1H spectroscopic imaging with automated quantification.

    abstract::A reproducibility study of proton MR spectroscopic imaging ((1)H-MRSI) of the human brain was conducted to evaluate the reliability of an automated 3D in vivo spectroscopic imaging acquisition and associated quantification algorithm. A PRESS-based pulse sequence was implemented using dualband spectral-spatial RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21713

    authors: Gu M,Kim DH,Mayer D,Sullivan EV,Pfefferbaum A,Spielman DM

    更新日期:2008-09-01 00:00:00

  • Quantification of atherosclerotic plaque components using in vivo MRI and supervised classifiers.

    abstract::In this work we aimed to study the possibility of using supervised classifiers to quantify the main components of carotid atherosclerotic plaque in vivo on the basis of multisequence MRI data. MRI data consisting of five MR weightings were obtained from 25 symptomatic subjects. Histological micrographs of endarterecto...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20828

    authors: Hofman JM,Branderhorst WJ,ten Eikelder HM,Cappendijk VC,Heeneman S,Kooi ME,Hilbers PA,ter Haar Romeny BM

    更新日期:2006-04-01 00:00:00

  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • Uniform spinning sampling gradient electron paramagnetic resonance imaging.

    abstract:PURPOSE:To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS:A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24712

    authors: Johnson DH,Ahmad R,Liu Y,Chen Z,Samouilov A,Zweier JL

    更新日期:2014-02-01 00:00:00