Intensity correction of phased-array surface coil images.

Abstract:

:Phased-array coils distribute the high signal-to-noise ratio (SNR) performance of their small component surface coils over the larger area covered by the entire array. The inhomogeneous sensitivity profiles of the component surface coils result in images with very high signal near the phased-array and decreased signal far from the array. This paper presents a postprocessing algorithm for correcting these coil-related intensity variations. The algorithm's performance was evaluated by correcting images of volunteers acquired with several different receive-only phased-array surface coils.

journal_name

Magn Reson Med

authors

Murakami JW,Hayes CE,Weinberger E

doi

10.1002/mrm.1910350419

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

585-90

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

35

pub_type

杂志文章
  • A computer simulation program for MR imaging: application to RF and static magnetic field imperfections.

    abstract::A computer simulation program capable of demonstrating various artifacts, such as image distortion caused by metallic implants in MR imaging, is presented. The structure of the program allows for the implementation of various imaging situations as long as spins only experience weak interaction, i.e., the Bloch equatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340418

    authors: Olsson MB,Wirestam R,Persson BR

    更新日期:1995-10-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21614

    authors: Leupold J,Hennig J,Scheffler K

    更新日期:2008-07-01 00:00:00

  • Improved sampling of myocardial motion with variable separation tagging.

    abstract::A novel tagging method is introduced that increases the spatial resolution of estimates of myocardial radial thickening. The separation of adjacent parallel tag planes is customized to match the expected motion of specific regions of the heart wall. In regions in which the tags increase their separation over systole (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390421

    authors: McVeigh ER,Bolster BD Jr

    更新日期:1998-04-01 00:00:00

  • Mapping of redox status in a brain-disease mouse model by three-dimensional EPR imaging.

    abstract::Electron paramagnetic resonance imaging using nitroxides is a powerful method for visualizing the redox status modulated by oxidative stress in vivo. Typically, however, data acquisition times have been too slow to obtain a sufficient number of projections for three-dimensional images, when using continuous wave-elect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22598

    authors: Fujii H,Sato-Akaba H,Kawanishi K,Hirata H

    更新日期:2011-01-01 00:00:00

  • The sensitivity of low flip angle RARE imaging.

    abstract::It is demonstrated that the stability of the Carr-Purcell-Meiboom-Gill (CPMG) sequence reflects the existence of a steady state solution to the Bloch equations in the absence of T2 and T1 decay. The steady state theory is then used to evaluate the performance of low flip angle RARE imaging sequences with both constant...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370206

    authors: Alsop DC

    更新日期:1997-02-01 00:00:00

  • Improved activation maps via the elimination of motion effects through time-domain mixing of data in conventional gradient echo functional MRI.

    abstract::To date, most functional imaging centers have relied on ultrafast imaging approaches such as echo-planar imaging (EPI) techniques for acquiring functional brain activation data. These methods require specialized hardware and are not yet installed widely on clinical MR imagers, thus limiting the application of function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380417

    authors: Constable RT

    更新日期:1997-10-01 00:00:00

  • Model-based mapping of fat unsaturation and chain length by chemical shift imaging--phantom validation and in vivo feasibility.

    abstract::Knowledge about the triglyceride (fat) (1)H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length, unsatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24196

    authors: Berglund J,Ahlström H,Kullberg J

    更新日期:2012-12-01 00:00:00

  • Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers.

    abstract:PURPOSE:Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural para...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25196

    authors: Kurz FT,Kampf T,Heiland S,Bendszus M,Schlemmer HP,Ziener CH

    更新日期:2014-05-01 00:00:00

  • Reconstruction by calibration over tensors for multi-coil multi-acquisition balanced SSFP imaging.

    abstract:PURPOSE:To develop a rapid imaging framework for balanced steady-state free precession (bSSFP) that jointly reconstructs undersampled data (by a factor of R) across multiple coils (D) and multiple acquisitions (N). To devise a multi-acquisition coil compression technique for improved computational efficiency. METHODS:...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26902

    authors: Biyik E,Ilicak E,Çukur T

    更新日期:2018-05-01 00:00:00

  • Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

    abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26903

    authors: Bane O,Hectors SJ,Wagner M,Arlinghaus LL,Aryal MP,Cao Y,Chenevert TL,Fennessy F,Huang W,Hylton NM,Kalpathy-Cramer J,Keenan KE,Malyarenko DI,Mulkern RV,Newitt DC,Russek SE,Stupic KF,Tudorica A,Wilmes LJ,Yankeelov TE

    更新日期:2018-05-01 00:00:00

  • Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI.

    abstract:PURPOSE:Oscillating gradient (OG) enables the access of short diffusion times for time-dependent diffusion MRI (dMRI); however, it poses several technical challenges for clinical use. This study proposes a 3D oscillating gradient-prepared gradient spin-echo (OGprep-GRASE) sequence to improve SNR and shorten acquisition...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28401

    authors: Wu D,Liu D,Hsu YC,Li H,Sun Y,Qin Q,Zhang Y

    更新日期:2021-01-01 00:00:00

  • Prospective multiaxial motion correction for fMRI.

    abstract::Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<459::aid-mrm19

    authors: Ward HA,Riederer SJ,Grimm RC,Ehman RL,Felmlee JP,Jack CR Jr

    更新日期:2000-03-01 00:00:00

  • Relative concentrations of proton MR visible neurochemicals in gray and white matter in human brain.

    abstract::The relative distributions of N-acetylaspartate (NAA) + N-acetylaspartylglutamate (NAAG), creatine + phosphocreatine (Cr/PCr), and choline (Cho) in the gray and white matter of human brain were determined by utilizing proton magnetic resonance spectroscopic imaging (SI). The SI data was processed using an automated sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330603

    authors: Doyle TJ,Bedell BJ,Narayana PA

    更新日期:1995-06-01 00:00:00

  • Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method.

    abstract::To achieve optimal image quality and highest spatial resolution for inner ear imaging with a 3D gradient echo sequence, it is necessary to minimize susceptibility dephasing effects by using very short TE. Fractional RF pulses and echoes can yield short TE for moderate spatial resolution; however, for voxel size of les...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330112

    authors: Ying K,Schmalbrock P,Clymer B

    更新日期:1995-01-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00

  • Biexponential longitudinal relaxation in white matter: Characterization and impact on T1 mapping with IR-FSE and MP2RAGE.

    abstract:PURPOSE:Magnetization transfer in white matter (WM) causes biexponential relaxation, but most quantitative T1 measurements fit data assuming monoexponential relaxation. The resulting monoexponential T1 estimate varies based on scan parameters and represents a source of variation between studies, especially at high fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25729

    authors: Rioux JA,Levesque IR,Rutt BK

    更新日期:2016-06-01 00:00:00

  • Quantification of perfusion in murine myocardium: A retrospectively triggered T1 -based ASL method using model-based reconstruction.

    abstract:PURPOSE:A method for the quantification of perfusion in murine myocardium is demonstrated. The method allows for the reconstruction of perfusion maps on arbitrary time points in the heart cycle while addressing problems that arise due to the irregular heart beat of mice. METHODS:A flow-sensitive alternating inversion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25526

    authors: Gutjahr FT,Kampf T,Winter P,Meyer CB,Williams T,Jakob PM,Bauer WR,Ziener CH,Helluy X

    更新日期:2015-12-01 00:00:00

  • Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

    abstract:PURPOSE:To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage. METHODS:A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25635

    authors: Ma C,Lam F,Johnson CL,Liang ZP

    更新日期:2016-02-01 00:00:00

  • Predicting RF field penetration in heterogeneous bodies using a 3-D finite element approach: preliminary results.

    abstract::We present preliminary results for a 3D finite element calculation to evaluate RF penetration in conducting dielectric materials at high field strengths. A tetrahedral mesh is used along with a Coulomb gauge constraint in a finite element method that yields excellent numerical stability at high frequencies. Accuracy i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300315

    authors: Petropoulos LS,Haacke EM,Brown RW,Boerner E

    更新日期:1993-09-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    abstract:PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25546

    authors: Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

    更新日期:2015-12-01 00:00:00

  • Robust estimation of spatially variable noise fields.

    abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22013

    authors: Landman BA,Bazin PL,Smith SA,Prince JL

    更新日期:2009-08-01 00:00:00

  • In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

    abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26190

    authors: Ganji SK,An Z,Tiwari V,McNeil S,Pinho MC,Pan E,Mickey BE,Maher EA,Choi C

    更新日期:2017-03-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • Toward fully automatic estimation of in vivo 31P spectra.

    abstract::Fitting a model to an experimental spectrum is a difficult nonlinear estimation problem. The solution presented here is to start an iterative search procedure sufficiently close to the optimal model parameter set. This is achieved by providing tissue-dependent a priori peak information and by a novel correlation metho...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210206

    authors: Burger C,McKinnon G,Buchli R,Boesiger P

    更新日期:1991-10-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • Self-calibrating parallel imaging with automatic coil sensitivity extraction.

    abstract::Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10087

    authors: McKenzie CA,Yeh EN,Ohliger MA,Price MD,Sodickson DK

    更新日期:2002-03-01 00:00:00

  • Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic device.

    abstract:PURPOSE:To develop a wideband cardiac perfusion pulse sequence and test whether it is capable of suppressing image artifacts in patients with a cardiac implantable electronic device (CIED), while not exceeding the specific absorption rate (SAR) limit (2.0 W/kg). METHODS:A wideband perfusion pulse sequence was develope...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27458

    authors: Hong K,Collins JD,Knight BP,Carr JC,Lee DC,Kim D

    更新日期:2019-02-01 00:00:00

  • Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

    abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24677

    authors: Mossahebi P,Yarnykh VL,Samsonov A

    更新日期:2014-02-01 00:00:00

  • Real-time observation of transient focal ischemia and hyperemia in cat brain.

    abstract::Gradient-recalled echo-planar (T2*-weighted) imaging was used to noninvasively monitor regional blood oxygenation state changes in real time during transient episodes of focal ischemia in cat brain. Varying ischemic intervals (12 s to 30 min) were caused by middle cerebral artery occlusion. A rapid signal drop was not...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270220

    authors: De Crespigny AJ,Wendland MF,Derugin N,Kozniewska E,Moseley ME

    更新日期:1992-10-01 00:00:00