MRI: the development of T2 contrast with rapid field echo sequences.

Abstract:

:The soft tissue contrast obtained in fast imaging using rapidly repeated partial saturation sequences is usually based on differences in T1. We describe here an extension of the method which results in the development of clinically useful T2-based contrast.

journal_name

Magn Reson Med

authors

Young IR,Payne JA,Collins AG,Bydder GM

doi

10.1002/mrm.1910040404

subject

Has Abstract

pub_date

1987-04-01 00:00:00

pages

333-40

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

4

pub_type

杂志文章
  • Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

    abstract:PURPOSE:At high field, T2 -weighted (T2 w) imaging is limited by transmit field inhomogeneity and increased radiofrequency power deposition. In this work, we introduce SAMPA (Slice-selective Adiabatic Magnetization T2 PrepAration) and demonstrate its use for efficient brain T2 w imaging at 7 Tesla (T). METHODS:SAMPA w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26067

    authors: Dyvorne H,Balchandani P

    更新日期:2016-12-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • Tuning and amplification strategies for intravascular imaging coils.

    abstract::The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal-to-noise benefits...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24134

    authors: Yak N,Anderson KJ,Wright GA

    更新日期:2012-11-01 00:00:00

  • Potassium transport in Langendorff-perfused mouse hearts assessed by 87Rb NMR spectroscopy.

    abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20450

    authors: Jilkina O,Xiang B,Kuzio B,Rendell J,Kupriyanov VV

    更新日期:2005-05-01 00:00:00

  • MRI monitoring of focused ultrasound sonications near metallic hardware.

    abstract:PURPOSE:To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. METHOD:2DMSI was optimized for temperature sensitivity and applied...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27034

    authors: Weber H,Ghanouni P,Pascal-Tenorio A,Pauly KB,Hargreaves BA

    更新日期:2018-07-01 00:00:00

  • Stereotaxic assembly and procedures for simultaneous electrophysiological and MRI study of conscious rat.

    abstract::A stereotaxic restraining assembly was designed and developed for simultaneous electrophysiological recordings and functional MRI (fMRI) data acquisition from a conscious rat. The design of the nonmagnetic stereotaxic apparatus facilitated the restraining of head and body of the unanesthetized conscious animal during ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10441

    authors: Khubchandani M,Mallick HN,Jagannathan NR,Mohan Kumar V

    更新日期:2003-05-01 00:00:00

  • High-resolution 31 P echo-planar spectroscopic imaging in vivo at 7T.

    abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26785

    authors: Korzowski A,Bachert P

    更新日期:2018-03-01 00:00:00

  • Mechanisms of proton spin dephasing in a system of magnetic particles.

    abstract::For protons diffusing among a system of magnetic particles, the process by which initial phase coherence is lost depends substantially on particle size. In this article, evidence for three dephasing mechanisms is presented: an incremental process at small particle sizes (motional averaging regime), a discrete process ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22966

    authors: de Haan HW

    更新日期:2011-12-01 00:00:00

  • Transmit and receive RF fields determination from a single low-tip-angle gradient-echo scan by scaling of SVD data.

    abstract:PURPOSE:A new method, called Transmit and Receive Patterns from Low-Tip-angle gradient-Echo Images (TRIPLET), is described which simultaneously maps the B1+ and B1- fields of a transmit/receive radiofrequency coil array. The input data are low-tip-angle gradient-echo images, which can be acquired in a relatively short ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24912

    authors: Sbrizzi A,Raaijmakers AJ,Hoogduin H,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-07-01 00:00:00

  • A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.

    abstract:PURPOSE:Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS:Two d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27031

    authors: Ertan K,Taraghinia S,Sadeghi A,Atalar E

    更新日期:2018-07-01 00:00:00

  • Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone.

    abstract::Measurements of the volume magnetic susceptibility of solids using the classical Gouy balance approach are hampered by variations in apparent density of the packed powder. In this paper a quantitative NMR measurement of the volume magnetic susceptibility of powdered solids is described and the volume susceptibility of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370404

    authors: Hopkins JA,Wehrli FW

    更新日期:1997-04-01 00:00:00

  • Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data.

    abstract:PURPOSE:To develop a strategy for training a physics-guided MRI reconstruction neural network without a database of fully sampled data sets. METHODS:Self-supervised learning via data undersampling (SSDU) for physics-guided deep learning reconstruction partitions available measurements into two disjoint sets, one of wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28378

    authors: Yaman B,Hosseini SAH,Moeller S,Ellermann J,Uğurbil K,Akçakaya M

    更新日期:2020-12-01 00:00:00

  • Porous medium 3D flow simulation of contrast media washout in cardiac MRI reflects myocardial injury.

    abstract:PURPOSE:Myocardial blood-flow simulation based on laws of fluid mechanics is a valuable tool for understanding tissue behavior. Our aim is to evaluate the ability of a porous-media flow model approach to reflect disturbed washout of contrast media (CM) from the myocardium as observed by cardiovascular MR. METHODS:A co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27756

    authors: Riazy L,Schaeffter T,Olbrich M,Schueler J,von Knobelsdorff-Brenkenhoff F,Niendorf T,Schulz-Menger J

    更新日期:2019-08-01 00:00:00

  • A controllable susceptibility marker for passive device tracking.

    abstract:PURPOSE:To design and demonstrate a new susceptibility-based tracking device with an artifact that can be mechanically turned on and off, thus permitting tracking and imaging at the device tip with limited artifact. METHODS:The magnetic susceptibilities of readily obtainable grades of titanium and graphite were measur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24899

    authors: Dominguez-Viqueira W,Karimi H,Lam WW,Cunningham CH

    更新日期:2014-07-01 00:00:00

  • Interactive coronary MRI.

    abstract::The acquisition of complete three-dimensional (3D), segmented gradient-echo data sets to visualize the coronary arteries can be both time consuming and sensitive to motion, even with use of multiple breath-holding or respiratory gating. An alternate hybrid approach is demonstrated here, in which real-time interactive ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400115

    authors: Hardy CJ,Darrow RD,Pauly JM,Kerr AB,Dumoulin CL,Hu BS,Martin KM

    更新日期:1998-07-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • Gadodiamide T1 relaxivity in brain tissue in vivo is lower than in saline.

    abstract::In vivo measurements of gadodiamide (Gd-DTPA-BMA) T(1) relaxivity were performed at 4.7 T in injured and normal rat brains. Cerebral lesions were induced in nine rats by a localized freezing method. T(1) maps of the lesions were generated before and after injection of Gd-DTPA-BMA (0.1-0.6 mmol/kg). Samples of normal a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20336

    authors: Pickup S,Wood AK,Kundel HL

    更新日期:2005-01-01 00:00:00

  • Perfusion MRI of U87 brain tumors in a mouse model.

    abstract::Continuous arterial spin labeling (CASL) was used to obtain an index of cerebral blood flow (ICBF) in the normal mouse brain and in an orthotopic mouse model of human U87 high-grade glioma at 8.5 T. Under the assumption of a constant tissue:blood partition coefficient for water in different tissues, the mean ICBF (n =...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20029

    authors: Sun Y,Schmidt NO,Schmidt K,Doshi S,Rubin JB,Mulkern RV,Carroll R,Ziu M,Erkmen K,Poussaint TY,Black P,Albert M,Burstein D,Kieran MW

    更新日期:2004-05-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.

    abstract::Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22737

    authors: Wang W,Nguyen NM,Yablonskiy DA,Sukstanskii AL,Osmanagic E,Atkinson JJ,Conradi MS,Woods JC

    更新日期:2011-03-01 00:00:00

  • Apparent diffusion of water, ions, and small molecules in the Xenopus oocyte is consistent with Brownian displacement.

    abstract::The incoherent displacement of water in living tissues is of considerable interest because of the widespread use of diffusion-weighted MRI, for which image contrast is based on the water apparent diffusion coefficient (ADC). It has been hypothesized that the decrease in water ADC associated with brain injury is primar...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10181

    authors: Sehy JV,Ackerman JJ,Neil JJ

    更新日期:2002-07-01 00:00:00

  • Optimization and validation of accelerated golden-angle radial sparse MRI reconstruction with self-calibrating GRAPPA operator gridding.

    abstract:PURPOSE:Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP recon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27030

    authors: Benkert T,Tian Y,Huang C,DiBella EVR,Chandarana H,Feng L

    更新日期:2018-07-01 00:00:00

  • Spatially resolved assessment of serotonin-induced bronchoconstrictive responses in the rat lung using 3He ventilation MRI under spontaneous breathing conditions.

    abstract::The effect on lung ventilation of bronchoconstriction induced by serotonin (intravenous injection of 50 microg/kg of serotonin) was imaged using a hyperpolarized (3)He MR ventilation protocol in spontaneously breathing rats. Lung function maps assessing airflow obstruction, a key feature in clinical pneumology, were d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22391

    authors: Mosbah K,Stupar V,Berthezène Y,Beckmann N,Crémillieux Y

    更新日期:2010-06-01 00:00:00

  • Metabolic markers of neuronal injury correlate with SIV CNS disease severity and inoculum in the macaque model of neuroAIDS.

    abstract::In vivo MR spectroscopy (MRS) studies have shown reductions in NAA/Cr levels in patients with severe neurocognitive deficits due to AIDS dementia complex (ADC), also known as neuroAIDS. The relationship between the cellular changes within the brain during neuroAIDS and the role of NAA/Cr as a metabolic marker remains ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21556

    authors: Lentz MR,Westmoreland SV,Lee V,Ratai EM,Halpern EF,González RG

    更新日期:2008-03-01 00:00:00

  • Use of high temperature superconductor in a receiver coil for magnetic resonance imaging.

    abstract::A planar YBa2Cu3Ox (YBCO) coil has been used as a pick-up coil in a nuclear magnetic resonance imager. It was found that the quality factor (Q) of the YBCO coil was greater than its copper counterpart by approaching 50% even in a field of 0.15 T. The Q of the copper coil at 77 K and in a field of 0.15 T was 1200 while...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200218

    authors: Hall AS,Alford NM,Button TW,Gilderdale DJ,Gehring KA,Young IR

    更新日期:1991-08-01 00:00:00

  • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla.

    abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21113

    authors: Marliani AF,Clementi V,Albini-Riccioli L,Agati R,Leonardi M

    更新日期:2007-01-01 00:00:00

  • In vivo validation of MR pulse pressure measurement in an aortic flow model: preliminary results.

    abstract::MR imaging experiments were conducted to investigate the feasibility of estimating vascular pulse pressure waveforms from measurements of blood flow rates and vessel cross-sectional area. Blood flow waveforms were measured in the aorta's of three 25-30-kg pigs at multiple imaging sections using phase-contrast velocity...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380209

    authors: Urchuk SN,Fremes SE,Plewes DB

    更新日期:1997-08-01 00:00:00

  • Measuring extracellular volume fraction by MRI: First verification of values given by clinical sequences.

    abstract:PURPOSE:To verify MR measurements of myocardial extracellular volume fraction (ECV) based on clinically applicable T1-mapping sequences against ECV measurements by radioisotope tracer in pigs and to relate the results to those obtained in volunteers. METHODS:Between May 2016 and March 2017, 8 volunteers (25 ± 4 years,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27938

    authors: Nordlund D,Xanthis C,Bidhult S,Jablonowski R,Kanski M,Kopic S,Carlsson M,Engblom H,Aletras AH,Arheden H

    更新日期:2020-02-01 00:00:00

  • Development of the human brain: in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy.

    abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300405

    authors: Kreis R,Ernst T,Ross BD

    更新日期:1993-10-01 00:00:00

  • Hypercarbia-induced changes in cerebral blood volume in the cat: a 1H MRI and intravascular contrast agent study.

    abstract::Cerebral blood volume changes with arterial carbon dioxide were monitored by proton T1-weighted MR images following administration of the intravascular contrast agent Gd-DTPA labeled with human serum albumin. Without MR contrast, no significant image intensity changes were observed with PaCO2. Following contrast, regi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230104

    authors: Moseley ME,Chew WM,White DL,Kucharczyk J,Litt L,Derugin N,Dupon J,Brasch RC,Norman D

    更新日期:1992-01-01 00:00:00