Reduced parameter formulation for incorporating fiber level viscoelasticity into tissue level biomechanical models.

Abstract:

:Collagen is known to be a viscoelastic material and therefore is an important source of time dependent behavior in soft tissue. Though there are material models for soft tissue that rely on properties and structure of constituent collagen fibers, such models generally utilize only the elastic properties of collagen, and thus the resulting tissue level response does not possess any viscoelastic features. Here, the time dependent properties of collagen are directly incorporated into a fiber based hyperelastic model using the one dimensional theory of quasi-linear viscoelasticity within the context of a locally defined, anisotropic representation of extracellular matrix structure. The resulting model possesses seven material parameters and, using numerical and computational analysis, is shown to successfully predict many key features of soft tissue response including anisotropy, strain hardening, preconditioning, and rate independent hysteresis. A formulation is also introduced for incorporating fiber level viscoelasticity into structural models derived from a continuous representation of fiber structure.

journal_name

Ann Biomed Eng

authors

Bischoff JE

doi

10.1007/s10439-006-9124-6

subject

Has Abstract

pub_date

2006-07-01 00:00:00

pages

1164-72

issue

7

eissn

0090-6964

issn

1573-9686

journal_volume

34

pub_type

杂志文章
  • Prediction of the biomechanical effects of compression therapy on deep veins using finite element modelling.

    abstract::Clinicians generally assume that Medical Compression Stockings (MCS) work by reducing vein luminal diameter and, in this way, help to prevent blood pooling. Conflicting results have been reported however in the case of lower leg deep veins which call into question this hypothesis. The purpose of this contribution is t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1121-6

    authors: Rohan PY,Badel P,Lun B,Rastel D,Avril S

    更新日期:2015-02-01 00:00:00

  • Hydraulic Conductivity of Smooth Muscle Cell-Initiated Arterial Cocultures.

    abstract::The purpose of the study was to examine the effects of arterial coculture conditions on the transport properties of several in vitro endothelial cell (EC)-smooth muscle cell (SMC)-porous filter constructs in which SMC were grown to confluence first and then EC were inoculated. This order of culturing simulates the env...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1421-5

    authors: Mathura RA,Russell-Puleri S,Cancel LM,Tarbell JM

    更新日期:2016-05-01 00:00:00

  • On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

    abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1267-x

    authors: Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

    更新日期:2015-09-01 00:00:00

  • A new bioreactor for the development of tissue-engineered heart valves.

    abstract::This paper reports the design, manufacturing, and characterization of a new bioreactor dedicated to the development of tissue-engineered heart valve substitutes. First, a comprehensive review of the state of the art in bioreactors is presented and a rigorous classification is put forward. The existing bioreactors foun...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9646-9

    authors: Ruel J,Lachance G

    更新日期:2009-04-01 00:00:00

  • A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

    abstract::The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9918-4

    authors: Ching CT,Sun TP,Huang SH,Shieh HL,Chen CY

    更新日期:2010-04-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • Velocity measurements within confined turbulent jets: application to cardiovalvular regurgitation.

    abstract::An expression for centerline mean velocity distributions for circular and noncircular confined turbulent jets has been obtained by assuming self-preservation of flow downstream of the jet potential core. It was assumed that the velocity decay was not only dependent on the streamwise distance x in terms of x/d, as in t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Liu H,Winoto SH,Shah DA

    更新日期:1997-11-01 00:00:00

  • An experimental and numerical investigation of head dynamics due to stick impacts in girls' lacrosse.

    abstract::A method of investigating head acceleration and intracranial dynamics from stick impacts in girls' and women's lacrosse was developed using headform impact experiments and a finite element head model. Assessing the likelihood of head injury due to stick-head impacts is of interest in girls' and women's lacrosse due to...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1091-8

    authors: Morse JD,Franck JA,Wilcox BJ,Crisco JJ,Franck C

    更新日期:2014-12-01 00:00:00

  • Numerical simulation of cell motion in tube flow.

    abstract::A theoretical model is presented for describing the motion of a deformable cell encapsulating a Newtonian fluid and enclosed by an elastic membrane in tube flow. In the mathematical formulation, the interior and exterior hydrodynamics are coupled with the membrane mechanics by means of surface equilibrium equations, a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8975-6

    authors: Pozrikidis C

    更新日期:2005-02-01 00:00:00

  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • Digital processing of the current noise evoked by kainate in cerebellar granule cells.

    abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684186

    authors: Cavalcanti S,Zona C

    更新日期:1997-05-01 00:00:00

  • Intelligent self-tuning of PID control for the robotic testing system for human musculoskeletal joints test.

    abstract::In this paper, an intelligent proportional-integral-derivative (PID) control method is introduced to the robotic testing system for the biomechanical study of human musculoskeletal joints. For the testing system, the robot is a highly nonlinear and heavily coupled complicated system, and the human spinal specimen also...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030759.80354.e8

    authors: Tian L

    更新日期:2004-06-01 00:00:00

  • Needle electrode-based electromechanical reshaping of cartilage.

    abstract::Electromechanical reshaping (EMR) of cartilage provides an alternative to the classic surgical techniques of modifying the shape of facial cartilages. The original embodiment of EMR required surface electrodes to be in direct contact with the entire cartilage region being reshaped. This study evaluates the feasibility...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0088-1

    authors: Manuel CT,Foulad A,Protsenko DE,Sepehr A,Wong BJ

    更新日期:2010-11-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • Can molecular imaging enable personalized diagnostics? An example using magnetomotive photoacoustic imaging.

    abstract::The advantages of photoacoustic (PA) imaging, including low cost, non-ionizing operation, and sub-mm spatial resolution at centimeters depth, make it a promising modality to probe nanoparticle-targeted abnormalities in real time at cellular and molecular levels. However, detecting rare cell types in a heterogeneous ba...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-013-0901-8

    authors: O'Donnell M,Wei CW,Xia J,Pelivanov I,Jia C,Huang SW,Hu X,Gao X

    更新日期:2013-11-01 00:00:00

  • Optical Metabolic Imaging for Assessment of Radiation-Induced Injury to Rat Kidney and Mitigation by Lisinopril.

    abstract::The kidney is one of the most radiosensitive organs; it is the primary dose-limiting organ in radiotherapies for upper abdominal cancers. The role of mitochondrial redox state in the development and treatment of renal radiation injury, however, remains ill-defined. This study utilizes 3D optical cryo-imaging to quanti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02255-8

    authors: Mehrvar S,la Cour MF,Medhora M,Camara AKS,Ranji M

    更新日期:2019-07-01 00:00:00

  • Optical vibrocardiography: a novel tool for the optical monitoring of cardiac activity.

    abstract::We present an optical non-contact method for heart beat monitoring, based on the measurement of chest wall movements induced by the pumping action of the heart, which is eligible as a surrogate of electrocardiogram (ECG) in assessing both cardiac rate and heart rate variability (HRV). The method is based on the optica...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9202-9

    authors: Morbiducci U,Scalise L,De Melis M,Grigioni M

    更新日期:2007-01-01 00:00:00

  • Nanoparticle-Mediated TGF-β Release from Microribbon-Based Hydrogels Accelerates Stem Cell-Based Cartilage Formation In Vivo.

    abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02522-z

    authors: Barati D,Gegg C,Yang F

    更新日期:2020-07-01 00:00:00

  • A Battery-Powered Ankle Exoskeleton Improves Gait Mechanics in a Feasibility Study of Individuals with Cerebral Palsy.

    abstract::Neuromuscular impairment associated with cerebral palsy (CP) often leads to life-long walking deficits. Our goal was to evaluate the ability of a novel untethered wearable ankle exoskeleton to reduce the severity of gait pathology from CP. In this clinical feasibility study of five individuals with CP, we used instrum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02237-w

    authors: Lerner ZF,Harvey TA,Lawson JL

    更新日期:2019-06-01 00:00:00

  • Characterizing the variability of system kernel and input estimates.

    abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.110

    authors: Verotta D

    更新日期:1998-09-01 00:00:00

  • The tendon injury response is influenced by decorin and biglycan.

    abstract::Defining the constituent regulatory molecules in tendon is critical to understanding the process of tendon repair and instructive to the development of novel treatment modalities. The purpose of this study is to define the structural, expressional, and mechanical changes in the tendon injury response, and elucidate th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0915-2

    authors: Dunkman AA,Buckley MR,Mienaltowski MJ,Adams SM,Thomas SJ,Satchell L,Kumar A,Pathmanathan L,Beason DP,Iozzo RV,Birk DE,Soslowsky LJ

    更新日期:2014-03-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Mesh Convergence Behavior and the Effect of Element Integration of a Human Head Injury Model.

    abstract::Numerous head injury models exist that vary in mesh density by orders of magnitude. A careful study of the mesh convergence behavior is necessary, especially in terms of strain most relevant to brain injury. To this end, as well as to investigate the effect of element integration scheme on simulated strains, we re-mes...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02159-z

    authors: Zhao W,Ji S

    更新日期:2019-02-01 00:00:00

  • Multi-Dimensional Nanostructures for Microfluidic Screening of Biomarkers: From Molecular Separation to Cancer Cell Detection.

    abstract::Rapid screening of biomarkers, with high specificity and accuracy, is critical for many point-of-care diagnostics. Microfluidics, the use of microscale channels to manipulate small liquid samples and carry reactions in parallel, offers tremendous opportunities to address fundamental questions in biology and provide a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1521-2

    authors: Ng E,Chen K,Hang A,Syed A,Zhang JX

    更新日期:2016-04-01 00:00:00

  • Increases of corporal temperature as a risk factor of atherosclerotic plaque instability.

    abstract:BACKGROUND:This work explores for the first time the effects of temperature increments on the development of high shear stresses between plaque and arterial wall due to their different dilatational properties. Data from the literature report febrile reactions prior to myocardial infarction in patients with normal coron...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9397-4

    authors: Guinea GV,Atienza JM,Fantidis P,Rojo FJ,Ortega A,Torres M,Gonzalez P,Elices ML,Hayashi K,Elices M

    更新日期:2008-01-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Rib Geometry Explains Variation in Dynamic Structural Response: Potential Implications for Frontal Impact Fracture Risk.

    abstract::The human thorax is commonly injured in motor vehicle crashes, and despite advancements in occupant safety rib fractures are highly prevalent. The objective of this study was to quantify the ability of gross and cross-sectional geometry, separately and in combination, to explain variation of human rib structural prope...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-017-1850-4

    authors: Murach MM,Kang YS,Goldman SD,Schafman MA,Schlecht SH,Moorhouse K,Bolte JH 4th,Agnew AM

    更新日期:2017-09-01 00:00:00

  • Passive-dynamic ankle-foot orthoses substitute for ankle strength while causing adaptive gait strategies: a feasibility study.

    abstract::Bending stiffness of passive-dynamic ankle-foot orthoses (PD-AFOs) is a functional characteristic thought to restore lost ankle function due to weakened plantar flexors. However, lower extremity impairment profiles of patients are seldom limited to plantar flexion weakness, and PD-AFO characteristics often influence g...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1067-8

    authors: Arch ES,Stanhope SJ

    更新日期:2015-02-01 00:00:00

  • Effects of Chemically Doped Bioactive Borate Glass on Neuron Regrowth and Regeneration.

    abstract::Peripheral nerve injuries present challenges to regeneration. Currently, the gold standard for nerve repair is an autograft that results in another region of the body suffering nerve damage. Previously, bioactive borate glass (BBG) has been studied in clinical trials to treat patients with non-healing wounds, and we h...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1689-0

    authors: Gupta B,Papke JB,Mohammadkhah A,Day DE,Harkins AB

    更新日期:2016-12-01 00:00:00