Abstract:
:This paper reports the design, manufacturing, and characterization of a new bioreactor dedicated to the development of tissue-engineered heart valve substitutes. First, a comprehensive review of the state of the art in bioreactors is presented and a rigorous classification is put forward. The existing bioreactors found in literature are organized in three groups and discussed with respect to their quality of reproduction compared to the physiological environment. The bioreactor architecture is then decomposed into basic components which may be grouped together in different arrangements, and the well-known Windkessel approach is used to study the global behavior of the system. Then, the new design, which is based on a synthesis of the features of the most evolved systems as well as on new improvements, is explained in detail. Optimal fluid dynamics are obtained with the presented bioreactor through carefully designed components and an advanced computer-controlled actuator. This allows a very accurate reproduction of physiological parameters, namely the pulsating flow rate and pressure. Finally, experimental results of flow rate and pressure waveforms are presented, where an excellent correlation with physiological measurements can be observed.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Ruel J,Lachance Gdoi
10.1007/s10439-009-9646-9subject
Has Abstractpub_date
2009-04-01 00:00:00pages
674-81issue
4eissn
0090-6964issn
1573-9686journal_volume
37pub_type
杂志文章abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1023/b:abme.0000012742.01261.b0
更新日期:2004-02-01 00:00:00
abstract::Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1688-1
更新日期:2016-12-01 00:00:00
abstract::We propose a multiphysical mathematical model by fully coupling lipid deposition, monocytes/macrophages recruitment and angiogenesis to investigate the pathophysiological responses of an atherosclerotic plaque to the dynamic changes in the microenvironment. The time evolutions of cellular (endothelial cells, macrophag...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02173-1
更新日期:2019-02-01 00:00:00
abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1340-5
更新日期:2015-06-01 00:00:00
abstract::The field of percutaneous coronary intervention has witnessed many progressions over the last few decades, more recently with the advancement of fully degradable bioabsorbable stents. Bioabsorbable materials, such as metallic alloys and aliphatic polyesters, have the potential to yield stents which provide temporary s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-015-1413-5
更新日期:2016-02-01 00:00:00
abstract::We compare the influence of time-frequency methods on analysis of time-varying renal autoregulation properties. Particularly, we examine if detection probabilities are similar for amplitude and frequency modulation for a modulated simulation signal among five time-frequency approaches, and if time-varying changes in s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0625-1
更新日期:2013-01-01 00:00:00
abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9952-2
更新日期:2010-04-01 00:00:00
abstract::Identifying the associations between head impact biomechanics and clinical recovery may inform better head impact monitoring procedures and identify athletes who may benefit from early treatments aimed to enhance recovery. The purpose of this study was to test whether head injury biomechanics are associated with clini...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02658-y
更新日期:2020-11-01 00:00:00
abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0677-2
更新日期:2013-03-01 00:00:00
abstract::This study presents a generic numerical model to simulate the coupled solute and solvent transport in tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA; dimethylsulfoxide or DMSO). Osmotic responses of various tissue cells within the artificial tissue are predicted by the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-1511-x
更新日期:2005-05-01 00:00:00
abstract::Despite cellular environments having dynamic characteristics, many laboratories utilized static polyacrylamide hydrogels to study the ECM-cell relationship. To attain a more in vivo like environment, we have developed a dynamic, DNA-crosslinked hydrogel (DNA gel). Through the controlled delivery of DNA, we can tempora...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0483-2
更新日期:2012-05-01 00:00:00
abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0242-9
更新日期:2011-05-01 00:00:00
abstract::The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02627-5
更新日期:2020-11-01 00:00:00
abstract::There has been considerable debate on the relative importance of biochemical stimuli and mechanical deformation in neutrophil adhesion in lung capillaries, a process observed following bacterial infection in the body. In contrast to venules, where the vessel diameter is larger than the leukocyte diameter (6-9 microm) ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9437-8
更新日期:2008-04-01 00:00:00
abstract::Pulmonary arterial hypertension (PAH) is caused by extensive pulmonary vascular remodeling that increases right ventricular (RV) afterload and leads to RV failure. PAH predominantly affects women; paradoxically, female PAH patients have better outcomes than men. The roles of estrogen in PAH remain controversial, which...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1716-1
更新日期:2017-03-01 00:00:00
abstract::Phenotype transformation of vascular smooth muscle cells (VSMCs) has been reported to be directly influenced by the frequency of mechanical strain. This study explored the effects of different frequencies of mechanical strain on expression of phenotype marker h1-calponin and the possible mechanism. VSMCs were subjecte...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9521-0
更新日期:2008-09-01 00:00:00
abstract::Parameters of physiological models are commonly associated in an input-output experiment with a specific pattern of the system response. This association is often made on an intuitive basis by traditional sensitivity analysis, i.e., by inspecting the variations of model output trajectories with respect to parameter va...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.207
更新日期:1999-09-01 00:00:00
abstract::A major benefit of computational modeling in biomechanics research is its ability to estimate internal muscular demands given limited input information. However, several assumptions regarding model parameters and constraints may influence model outputs. This research evaluated the influence of model parameter variabil...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1035-3
更新日期:2014-09-01 00:00:00
abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1892-7
更新日期:2017-11-01 00:00:00
abstract::A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference wa...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.219
更新日期:1999-03-01 00:00:00
abstract::A computer-controlled optical electromechanical biaxial test system was employed to study the mechanical response of excised sheets of canine visceral pleura. Three classes of tests were performed: uniform biaxial stretching tests and tests in which the specimen was cyclically stretched along one axis while either the...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02367365
更新日期:1986-01-01 00:00:00
abstract::Cellular engineering applies the principles and methods of engineering to the problems of cell and molecular biology of both a basic and applied nature. As biomedical engineering has shifted from the organ and tissue level to the cellular and sub-cellular level, cellular engineering has emerged as a new area. A corner...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/BF02367396
更新日期:1991-01-01 00:00:00
abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0329-y
更新日期:2011-09-01 00:00:00
abstract::The aim of this study was to develop an empirical model of parameter-based gait data, based on an artificial neural network and a genetic algorithm, for the assessment of patients after ankle arthrodesis. Ground reaction force vectors were measured by force platforms during level walking. Nine force parameters express...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1114/1.1342053
更新日期:2001-01-01 00:00:00
abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1627-1
更新日期:2016-11-01 00:00:00
abstract::Calcium phosphate ceramics have been widely used for filling bone defects to aid in the regeneration of new bone tissue. Addition of osteogenic cells to porous ceramic scaffolds may accelerate the bone repair process. This study demonstrates the feasibility of culturing marrow stromal cells (MSCs) on porous biphasic c...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-5536-y
更新日期:2005-09-01 00:00:00
abstract::Experimental and diagnostic procedures like distension of a balloon catheter, bougie, and esophagogastroduodenoscopy can induce shear deformation in the esophageal wall. However, the shear modulus of the esophagus is yet unknown. The aim of this study was to determine the esophageal shear modulus and its dependence on...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/b:abme.0000039356.24821.6c
更新日期:2004-09-01 00:00:00
abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0276-7
更新日期:2011-06-01 00:00:00
abstract::The applicability of a computer model, which relates the transmural mechanical distribution in the left ventricle (LV) to its global function at different loading conditions, was evaluated in patients with normal to near normal LV function undergoing cardiac catheterization. Left ventriculography and measurements of a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02364159
更新日期:1990-01-01 00:00:00
abstract::Microfluidic devices aim at miniaturizing, automating, and lowering the cost of chemical and biological sample manipulation and detection, hence creating new opportunities for lab-on-a-chip platforms. Recently, optofluidic devices have also emerged where optics is used to enhance the functionality and the performance ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-011-0385-3
更新日期:2012-02-01 00:00:00