Analysis and prediction of left ventricular performance under load changes during cardiac catheterization.

Abstract:

:The applicability of a computer model, which relates the transmural mechanical distribution in the left ventricle (LV) to its global function at different loading conditions, was evaluated in patients with normal to near normal LV function undergoing cardiac catheterization. Left ventriculography and measurements of aortic and LV pressures were performed at baseline conditions and repeated following rapid volume expansion with intravenous infusion of 250 to 300 ml of physiologic saline and also after sublingual isosorbide-dinitrate (ISDN) administration. Twenty patients (18 men and 2 women, average age = 53 years) underwent coronary angiography and left ventriculography. Sixteen patients had coronary artery disease with one- to three-vessel involvement and 4 had normal coronary arteries. The measured input data into the model included the end-diastolic LV volume and wall thickness, aortic pressure, heart rate, and the peripheral resistance. The model parameters of myocardial contractility and arterial system capacitance for the control baseline conditions were estimated so that an accurate match was obtained between the predicted and the measured end-systolic (ES) volume and pressure. Using these parameters, model predictions for the two load perturbations were compared to the measurements. An excellent correlation was found between the predicted and measured LV ES volumes and peak-systolic pressures (PSP) (R2 greater than 0.994). In four patients, who developed ischemic symptoms during saline injection, the prediction of end-systole volumes were lower than the measured values, suggesting an actual reduction in contractility during acute ischemia. Therefore, the model is sensitive to contractility changes. The model predicts global LV performance, under different loading conditions, including stroke work, peak developed wall stress, velocity of fiber shortening, and myocardial oxygen consumption.

journal_name

Ann Biomed Eng

authors

Abboud L,Beyar R,Battler A,Rat M,Cohen A,Sideman S

doi

10.1007/BF02364159

subject

Has Abstract

pub_date

1990-01-01 00:00:00

pages

445-61

issue

4

eissn

0090-6964

issn

1573-9686

journal_volume

18

pub_type

杂志文章
  • Novel Balloon Surface Scanning Device for Intraoperative Breast Endomicroscopy.

    abstract::Recent advances in fluorescence confocal endomicroscopy have allowed real-time identification of residual tumour cells on the walls of the cavity left by breast conserving surgery. However, it is difficult to systematically survey the surgical site because of the small imaging field-of-view of these probes, compounded...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1493-2

    authors: Zuo S,Hughes M,Yang GZ

    更新日期:2016-07-01 00:00:00

  • Native, living tissues as cell seeded scaffolds.

    abstract::Much effort is expended in developing biomimetic scaffolds that provide the micro-architecture of native tissue with appropriate cellular niches. Such scaffolds are often seeded with progenitor cells to generate engineered replacements for diseased or damaged tissues. An alternative approach relies on biology, rather ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1174-6

    authors: Evans CH

    更新日期:2015-03-01 00:00:00

  • Effect of Subject-Specific Vertebral Position and Head and Neck Size on Calculation of Spine Musculoskeletal Moments.

    abstract::Spine musculoskeletal models used to estimate loads and displacements require many simplifying assumptions. We examined how assumptions about subject size and vertebral positions can affect the model outcomes. Head and neck models were developed to represent 30 subjects (15 males and 15 females) in neutral posture and...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-2084-9

    authors: Vasavada AN,Hughes E,Nevins DD,Monda SM,Lin DC

    更新日期:2018-11-01 00:00:00

  • A reaction-diffusion model of basic fibroblast growth factor interactions with cell surface receptors.

    abstract::Basic fibroblast growth factor (FGF-2) is a potent angiogenic growth factor involved in the development of diseases such as cancer, atherosclerosis, and heart and limb ischemia, as well as normal wound healing and tissue development. Despite being one of the most heavily studied angiogenic growth factors, the binding ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030231.88326.78

    authors: Filion RJ,Popel AS

    更新日期:2004-05-01 00:00:00

  • Redirection of neurite outgrowth by coupling chondroitin sulfate proteoglycans to polymer membranes.

    abstract::Upon nerve injury, the body creates an environment consisting of permissive and non-permissive cues that instruct the function of cells involved in nerve repair. Among other roles, the developing extracellular matrix (ECM) acts as an underlying substrate to guide the union of neurites extending from the proximal stump...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0991-y

    authors: Man AJ,Leach JK,Bannerman P

    更新日期:2014-06-01 00:00:00

  • Sharing best practices in teaching biomedical engineering design.

    abstract::In an effort to share best practices in undergraduate engineering design education, we describe the origin, evolution and the current status of the undergraduate biomedical engineering design team program at Johns Hopkins University. Specifically, we describe the program and judge the quality of the pedagogy by relati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0781-y

    authors: Allen RH,Acharya S,Jancuk C,Shoukas AA

    更新日期:2013-09-01 00:00:00

  • Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes.

    abstract::Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1933-2

    authors: Ahola A,Pölönen RP,Aalto-Setälä K,Hyttinen J

    更新日期:2018-01-01 00:00:00

  • A visualization-based analysis method for multiparameter models of capillary tissue-exchange.

    abstract::In order to successfully use a model for parameter identification, it must be carefully analyzed. Current analysis methods, however, are ad hoc and provide only partial information. We extended these methods through the application of stacked dimensions, a scientific visualization method. The end result of our extensi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02771001

    authors: Bosan S,Harris TR

    更新日期:1996-01-01 00:00:00

  • Adhesion of microfabricated particles on vascular endothelium: a parametric analysis.

    abstract::"Smart" drug delivery systems should be selective and effective to ensure drug administration at the right time, at the right dosage, and anywhere in the body. Among the several administration routes and delivery systems that have been proposed, one of the most effective and promising is based on microfabricated parti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030255.36748.d3

    authors: Decuzzi P,Lee S,Decuzzi M,Ferrari M

    更新日期:2004-06-01 00:00:00

  • Modeling of Experimental Atherosclerotic Plaque Delamination.

    abstract::A cohesive zone model (CZM) approach is applied to simulate atherosclerotic plaque delamination experiments in mouse abdominal aorta specimens. A three-dimensional finite element model is developed for the experiments. The aortic wall is treated as a fiber-reinforced, highly deformable, incompressible material, and th...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1357-9

    authors: Leng X,Chen X,Deng X,Sutton MA,Lessner SM

    更新日期:2015-12-01 00:00:00

  • Nonlinear dynamics of microvascular blood flow.

    abstract::Kiani et al. (Kiani, M. F., A. R. Pries, L. L. Hsu, I. H. Sarelius, and G. R. Cokelet, Am. J. Physics. 266: H1822-H1828, 1994) suggested that blood velocity, hematocrit, and nodal pressures can oscillate spontaneously in large microvascular networks in the absence of biological control. This paper presents a model of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1306346

    authors: Carr RT,Lacoin M

    更新日期:2000-06-01 00:00:00

  • Intelligent multichannel stimulator for the study of cardiac arrhythmias.

    abstract::An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1451077

    authors: Johnson PL,Newton JC,Rollins DL,Knisley SB,Ideker RE,Smith WM

    更新日期:2002-02-01 00:00:00

  • A Novel Approach to Utilize Icariin as Icariin-Derived ECM on Small Intestinal Submucosa Scaffold for Bone Repair.

    abstract::Icariin (Ic) has been demonstrated as a potent osteoinductive compound for bone tissue engineering. However, toxic side effects of the drug and poor biocompatibility of drug delivery systems (DDSs) still limit its application for bone repair in the clinic. To overcome these disadvantages and utilize the osteoinductivi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1900-y

    authors: Li M,Zhang C,Zhong Y,Zhao J

    更新日期:2017-11-01 00:00:00

  • The air-conditioning capacity of the human nose.

    abstract::The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2513-4

    authors: Naftali S,Rosenfeld M,Wolf M,Elad D

    更新日期:2005-04-01 00:00:00

  • Endothelial gene expression in regions of defined shear exposure in the porcine iliac arteries.

    abstract::The effect of hemodynamic shear stress on endothelial gene expression was investigated in the porcine iliac arteries. A novel statistical approach was applied to computational fluid dynamics simulations of the iliac artery flow field to identify three anatomical regions likely to experience high, medium, and low level...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0030-6

    authors: LaMack JA,Himburg HA,Zhang J,Friedman MH

    更新日期:2010-07-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Two methods for recommending bat weights.

    abstract::Baseball players swung very light and very heavy bats through our instrument and the speed of the bat was recorded. These data were used to make mathematical models for each person. Then these models were coupled with equations of physics for bat-ball collisions to compute the Ideal Bat Weight for each individual. How...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584443

    authors: Bahill AT,Freitas MM

    更新日期:1995-07-01 00:00:00

  • Investigating tendon fascicle structure-function relationships in a transgenic-age mouse model using multiple regression models.

    abstract::Proper replacement or repair of damaged tendons or ligaments requires functionally engineered tissue that mimics their native mechanical properties. While tendon structure-function relationships are generally assumed, there exists little quantitative evidence of the roles of distinct tendon components in tendon functi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000032455.78459.56

    authors: Robinson PS,Lin TW,Jawad AF,Iozzo RV,Soslowsky LJ

    更新日期:2004-07-01 00:00:00

  • New perspectives on bioengineering of joint tissues: joint adaptation creates a moving target for engineering replacement tissues.

    abstract::The current paradigm in tissue engineering is that "full regeneration" or "total replacement" of normal tissue is required in order to restore joint function. However, there is considerable evidence that suggests that targets other than "normality" may actually be required for tissue substitutes. Sometimes "less than ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000017548.85451.b7

    authors: Frank CB,Shrive NG,Boorman RS,Lo IK,Hart DA

    更新日期:2004-03-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics.

    abstract::Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell dama...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1008-6

    authors: Gunning PS,Saikrishnan N,McNamara LM,Yoganathan AP

    更新日期:2014-06-01 00:00:00

  • Evaluation of effectiveness of a facet wiring technique: an in vitro biomechanical investigation.

    abstract::The effects of facet wiring procedure commonly used for stabilizing cervical spines after laminectomy or bilateral facet dislocation on the motion behavior of whole cervical spines are investigated using a Selspot II system. A fresh human ligamentous intact specimen was potted at T1/T2 vertebra and clinically relevant...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368022

    authors: Goel VK,Clark CR,Harris KG,Kim YE,Schulte KR

    更新日期:1989-01-01 00:00:00

  • A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves.

    abstract::This study was aimed at developing a physical model, supported by experimental observations, to describe the formation and growth of microbubbles seen in patients with mitral mechanical heart valves (MHV). This phenomenon, often referred to as high intensity transient signals (HITS), appears as bright, intense, high-v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.231

    authors: Rambod E,Beizaie M,Shusser M,Milo S,Gharib M

    更新日期:1999-11-01 00:00:00

  • Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

    abstract::Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000049034.75368.4a

    authors: Chau AH,Chan RC,Shishkov M,MacNeill B,Iftimia N,Tearney GJ,Kamm RD,Bouma BE,Kaazempur-Mofrad MR

    更新日期:2004-11-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • Arterial luminal curvature and fibrous-cap thickness affect critical stress conditions within atherosclerotic plaque: an in vivo MRI-based 2D finite-element study.

    abstract::High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FC(MIN)) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0078-3

    authors: Teng Z,Sadat U,Li Z,Huang X,Zhu C,Young VE,Graves MJ,Gillard JH

    更新日期:2010-10-01 00:00:00

  • Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

    abstract::A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even afte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1282-y

    authors: Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

    更新日期:2015-10-01 00:00:00

  • Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves.

    abstract::Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000036640.11387.4b

    authors: Hildebrand DK,Wu ZJ,Mayer JE Jr,Sacks MS

    更新日期:2004-08-01 00:00:00

  • In vitro characterization of a compliant biodegradable scaffold with a novel bioreactor system.

    abstract::The influence of scaffold compliance on blood vessel tissue engineering remains unclear and compliance mismatch issues are important to an in vivo tissue-engineering approach. We have designed and constructed a modular bioreactor system that is capable of imparting pulsatile fluid flow while simultaneously measuring v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9304-z

    authors: Webb AR,Macrie BD,Ray AS,Russo JE,Siegel AM,Glucksberg MR,Ameer GA

    更新日期:2007-08-01 00:00:00

  • A paradigm for functional tissue engineering of articular cartilage via applied physiologic deformational loading.

    abstract::Deformational loading represents a primary component of the chondrocyte physical environment in vivo. This review summarizes our experience with physiologic deformational loading of chondrocyte-seeded agarose hydrogels to promote development of cartilage constructs having mechanical properties matching that of the par...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000007789.99565.42

    authors: Hung CT,Mauck RL,Wang CC,Lima EG,Ateshian GA

    更新日期:2004-01-01 00:00:00