Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

Abstract:

:In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing periosteal strains for normal and surgically treated ovine femora subjected ex vivo to compressive loads simulating in vivo stance shifting (n = 3 per group, normal vs. treated). We determined spatial distribution of calcein green, a label for bone apposition in first the 2 weeks after surgery, in 15°, 30°, and 45° sectors of histological cross sections through the middle of the defect zone (n = 6 bones, three to four sections per bone). Finally, we correlated early bone formation to either the maximal periosteal strain or the net change in maximal periosteal strain. We found that treatment with the one-stage bone-transport surgery profoundly changes the mechanical environment of cells within the periosteum during stance shift loading. The pattern of early bone formation is repeatable within and between animals and relates significantly to the actual strain magnitude prevailing in the periosteum during stance shift loading. Interestingly, early bone apposition after the surgery correlates well to the maximal net change in strain (above circa 2000-3000 με, in tension or compression) rather than strain magnitude per se, providing further evidence that changes in cell shape may drive mechanoadaptation by progenitor cells. These important insights regarding mechanobiological factors that enhance rapid bone generation in critically sized defects can be translated to the tissue and organ scale, providing a basis for the development of best practices for clinical implementation and the definition of movement protocols to enhance the regenerative effect.

journal_name

Ann Biomed Eng

authors

McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

doi

10.1007/s10439-010-0242-9

subject

Has Abstract

pub_date

2011-05-01 00:00:00

pages

1570-81

issue

5

eissn

0090-6964

issn

1573-9686

journal_volume

39

pub_type

杂志文章
  • Preparation of chitosan/hydroxyapatite substrates with controllable osteoconductivity tracked by AFM.

    abstract::In this study, cell-material adhesive strength and cellular mechanical properties were measured using atomic force microscopy (AFM) to track cell attachment and osteogenic differentiation. First, chitosan substrates were treated with simulated body fluid (SBF) for various periods, resulting in substrates with differen...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1162-x

    authors: Ho MH,Li CH,Hsiao SW,Thien DV

    更新日期:2015-04-01 00:00:00

  • Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

    abstract::Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000049034.75368.4a

    authors: Chau AH,Chan RC,Shishkov M,MacNeill B,Iftimia N,Tearney GJ,Kamm RD,Bouma BE,Kaazempur-Mofrad MR

    更新日期:2004-11-01 00:00:00

  • Rib Geometry Explains Variation in Dynamic Structural Response: Potential Implications for Frontal Impact Fracture Risk.

    abstract::The human thorax is commonly injured in motor vehicle crashes, and despite advancements in occupant safety rib fractures are highly prevalent. The objective of this study was to quantify the ability of gross and cross-sectional geometry, separately and in combination, to explain variation of human rib structural prope...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-017-1850-4

    authors: Murach MM,Kang YS,Goldman SD,Schafman MA,Schlecht SH,Moorhouse K,Bolte JH 4th,Agnew AM

    更新日期:2017-09-01 00:00:00

  • Parametric comparisons of intracranial mechanical responses from three validated finite element models of the human head.

    abstract::A number of human head finite element (FE) models have been developed from different research groups over the years to study the mechanisms of traumatic brain injury. These models can vary substantially in model features and parameters, making it important to evaluate whether simulation results from one model are read...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0907-2

    authors: Ji S,Ghadyani H,Bolander RP,Beckwith JG,Ford JC,McAllister TW,Flashman LA,Paulsen KD,Ernstrom K,Jain S,Raman R,Zhang L,Greenwald RM

    更新日期:2014-01-01 00:00:00

  • Changes of flow characteristics by stenting in aneurysm models: influence of aneurysm geometry and stent porosity.

    abstract::An endovascular technique using a stent has been developed and successfully applied in the treatment of wide neck aneurysms. A stent can facilitate thrombosis in the aneurysm pouch while maintaining biocompatible passage of the parent artery. Insertion of the stent changes the flow characteristics inside the aneurysm ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1500406

    authors: Rhee K,Han MH,Cha SH

    更新日期:2002-07-01 00:00:00

  • Second harmonic generation imaging and Fourier transform spectral analysis reveal damage in fatigue-loaded tendons.

    abstract::Conventional histologic methods provide valuable information regarding the physical nature of damage in fatigue-loaded tendons, limited to thin, two-dimensional sections. We introduce an imaging method that characterizes tendon microstructure three-dimensionally and develop quantitative, spatial measures of damage for...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9976-7

    authors: Fung DT,Sereysky JB,Basta-Pljakic J,Laudier DM,Huq R,Jepsen KJ,Schaffler MB,Flatow EL

    更新日期:2010-05-01 00:00:00

  • The effect of blood flow on the material properties of bone.

    abstract::This project was undertaken to establish if the integral circulation had any effects upon the mechanical behavior of bone. The influence of blood flow in the rabbit tibia on the strain induced at the bone surface when under load was assessed. Recordings were taken from three adult and three immature New Zealand White ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02390377

    authors: McDonald F,Pitt Ford TR

    更新日期:1994-03-01 00:00:00

  • Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI.

    abstract::Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02491-3

    authors: Johnson EMI,Heller JA,Garcia Vicente F,Sarnari R,Gordon D,McCarthy PM,Barker AJ,Etemadi M,Markl M

    更新日期:2020-06-01 00:00:00

  • Measurement of Strain in Cardiac Myocytes at Micrometer Scale Based on Rapid Scanning Confocal Microscopy and Non-Rigid Image Registration.

    abstract::Measurement of cell shortening is an important technique for assessment of physiology and pathophysiology of cardiac myocytes. Many types of heart disease are associated with decreased myocyte shortening, which is commonly caused by structural and functional remodeling. Here, we present a new approach for local measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1593-7

    authors: Lichter J,Li H,Sachse FB

    更新日期:2016-10-01 00:00:00

  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • A general framework for characterizing studies of brain interface technology.

    abstract::The development of brain interface (BI) technology continues to attract researchers with a wide range of backgrounds and expertise. Though the BI community is committed to accurate and objective evaluation of methods, systems, and technology, the very diversity of the methods and terminology used in the field hinders ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7706-3

    authors: Mason SG,Jackson MM,Birch GE

    更新日期:2005-11-01 00:00:00

  • Differential changes in the molecular stability of collagen from the pulmonary and aortic valves during the fetal-to-neonatal transition.

    abstract::During the fetal-to-neonatal transition, transvalvular pressures (TVPs) on the aortic and pulmonary valves change dramatically-but differently for each valve. We have examined changes in the molecular stability and crosslinking of collagen during this transition. Aortic and pulmonary valves were harvested from fetal a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0061-z

    authors: Aldous IG,Lee JM,Wells SM

    更新日期:2010-09-01 00:00:00

  • Optimizing magnetic nanoparticle based thermal therapies within the physical limits of heating.

    abstract::Magnetic nanoparticle (mNP) based thermal therapies have demonstrated relevance in the clinic, but effective application requires an understanding of both its strengths and limitations. This study explores two critical limitations for clinical use: (1) maximizing localized mNP heating, while avoiding bulk heating due ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0633-1

    authors: Etheridge ML,Bischof JC

    更新日期:2013-01-01 00:00:00

  • An Integrated In Vitro-In Silico Approach for Silver Nanoparticle Dosimetry in Cell Cultures.

    abstract::Potential human and environmental hazards resulting from the exposure of living organisms to silver nanoparticles (Ag NPs) have been the subject of intensive discussion in the last decade. Despite the growing use of Ag NPs in biomedical applications, a quantification of the toxic effects as a function of the total sil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02449-5

    authors: Poli D,Mattei G,Ucciferri N,Ahluwalia A

    更新日期:2020-04-01 00:00:00

  • Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model.

    abstract::Congenital heart disease is the leading cause of infant death in the United States with over 36,000 newborns affected each year. Despite this growing problem there are few mechanical circulatory support devices designed specifically for pediatric and neonate patients. Previous research has been done investigating pedi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1370-z

    authors: Good BC,Deutsch S,Manning KB

    更新日期:2016-04-01 00:00:00

  • Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

    abstract::In the field of fluid flow within the human body, focus has been placed on the transportation of blood in the systemic circulation since the discovery of that system; but, other fluids and fluid flow phenomena pervade the body. Some of the most fascinating fluid flow phenomena within the human body involve fluids othe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9902-z

    authors: Zamir M,Moore JE Jr,Fujioka H,Gaver DP 3rd

    更新日期:2010-03-01 00:00:00

  • Velocity measurements within confined turbulent jets: application to cardiovalvular regurgitation.

    abstract::An expression for centerline mean velocity distributions for circular and noncircular confined turbulent jets has been obtained by assuming self-preservation of flow downstream of the jet potential core. It was assumed that the velocity decay was not only dependent on the streamwise distance x in terms of x/d, as in t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Liu H,Winoto SH,Shah DA

    更新日期:1997-11-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • A piconewton force transducer and its application to measurement of the bending stiffness of phospholipid membranes.

    abstract::The bending stiffness of a phospholipid bilayer (Kc) was measured by forming thin bilayer cylinders (tethers) from giant phospholipid vesicles. Based on the balance of forces, the tether force was expected to be proportional to the square root of the membrane tension, with a constant of proportionality containing Kc. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684228

    authors: Heinrich V,Waugh RE

    更新日期:1996-09-01 00:00:00

  • Human saphenous vein coronary artery bypass graft morphology, geometry and hemodynamics.

    abstract::Coronary artery bypass graft (CABG) failure has been linked to graft hemodynamics, in particular wall shear stress. This study characterizes the morphology, geometry and wall shear stress patterns in human CABGs. The intimal thickness (IT) in 49 human saphenous vein CABGs was measured by digital light microscopy. The ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1732-z

    authors: Leask RL,Butany J,Johnston KW,Ethier CR,Ojha M

    更新日期:2005-03-01 00:00:00

  • Myofiber ellipticity as an explanation for transverse asymmetry of skeletal muscle diffusion MRI in vivo signal.

    abstract::Due to its unique non-invasive microstructure probing capabilities, diffusion tensor imaging (DTI) constitutes a valuable tool in the study of fiber orientation in skeletal muscles. By implementing a DTI sequence with judiciously chosen directional encoding to quantify in vivo the microarchitectural properties in the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9783-1

    authors: Karampinos DC,King KF,Sutton BP,Georgiadis JG

    更新日期:2009-12-01 00:00:00

  • Partitioning of cortical and deep cytoskeleton responses from transient magnetic bead twisting.

    abstract::We attempted to estimate in living adherent epithelial alveolar cells, the degree of structural and mechanical heterogeneity by considering two individualized cytoskeleton components, i.e., a submembranous "cortical" cytoskeleton and a "deep" cytoskeleton (CSK). F-actin structure characterizing each CSK component was ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1616932

    authors: Laurent VM,Fodil R,Cañadas P,Féréol S,Louis B,Planus E,Isabey D

    更新日期:2003-11-01 00:00:00

  • LDL decreases the membrane compliance and cell adhesion of endothelial cells under fluid shear stress.

    abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0677-2

    authors: Wei D,Chen Y,Tang C,Huang H,Liu L,Wang Z,Li R,Wang G

    更新日期:2013-03-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • A Novel Apparatus for the Multifaceted Evaluation of Arterial Function Through Transmural Pressure Manipulation.

    abstract::A novel apparatus for the multifaceted evaluation of artery function was developed. It measures endothelial and smooth muscle functions and the pressure-strain elastic modulus (E p). A rigid airtight chamber with an ultrasound probe was attached to the upper arm to manipulate the transmural pressure of the brachial ar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1810-z

    authors: Yaguchi T,Cong Y,Shimo K,Kurokawa T,Sugita S,Nagayama K,Masuda H,Matsumoto T

    更新日期:2017-06-01 00:00:00

  • Do increased electrogastrographic frequencies always correspond to internal tachygastria?

    abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Mintchev MP,Bowes KL

    更新日期:1997-11-01 00:00:00

  • A reaction-diffusion model of basic fibroblast growth factor interactions with cell surface receptors.

    abstract::Basic fibroblast growth factor (FGF-2) is a potent angiogenic growth factor involved in the development of diseases such as cancer, atherosclerosis, and heart and limb ischemia, as well as normal wound healing and tissue development. Despite being one of the most heavily studied angiogenic growth factors, the binding ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030231.88326.78

    authors: Filion RJ,Popel AS

    更新日期:2004-05-01 00:00:00

  • On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

    abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1267-x

    authors: Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

    更新日期:2015-09-01 00:00:00

  • Strontium ranelate prevents bone loss in a rat model of localized muscle paralysis.

    abstract::Twenty-one 3.5-month-old female Sprague-Dawley rats were randomly assigned to three groups: BTX group, in which each rat received a single intramuscular injection of 2 U of Clostridium botulinum toxin (BTX) in the quadriceps femoris muscle of the right hind limb; BTX + SR group, in which each rat received a BTX inject...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0406-2

    authors: Sheng ZF,Ma YL,Tong D,Fang DY,Liang QC,Liu LH,Zhang J,Liao EY

    更新日期:2012-03-01 00:00:00