Abstract:
:A major benefit of computational modeling in biomechanics research is its ability to estimate internal muscular demands given limited input information. However, several assumptions regarding model parameters and constraints may influence model outputs. This research evaluated the influence of model parameter variability, specifically muscle attachment locations and glenohumeral stability thresholds, on predicted rotator cuff muscle force during internal and external axial humeral rotation tasks. Additionally, relative sensitivity factors assessed which parameters were more contributory to output variability. Modest model parameter variation resulted in considerable variability in predicted force, with origin-insertion locations being particularly influential. Specifically, the scapula attachment site of the subscapularis muscle was important for modulating predicted force, with sensitivity factors ranging from α=0.2 to 0.7 in a neutral position. The largest variability in predicted forces was present for the subscapularis muscle, with average differences of 33.0±9.6% of normalized muscle force (1-99% CI), and a maximal difference of 51% in neutral exertions. Infraspinatus and supraspinatus muscles elicited maximal differences of 15.0 and 20.6%, respectively, between confidence limits. Overall, origin and insertion locations were most influential and thus incorporating geometric variation in the prediction of rotator cuff muscle forces may provide more representative population estimates.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Chopp-Hurley JN,Langenderfer JE,Dickerson CRdoi
10.1007/s10439-014-1035-3subject
Has Abstractpub_date
2014-09-01 00:00:00pages
1867-79issue
9eissn
0090-6964issn
1573-9686journal_volume
42pub_type
杂志文章abstract::It is well known that neutrophils take much longer to traverse the pulmonary capillary bed than erythrocytes, and this is likely due to differences in the structure and rheology of the cells. In this study, we simulate the transit of a neutrophil in a capillary using a Newtonian drop model and a viscoelastic drop mode...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9286-x
更新日期:2007-05-01 00:00:00
abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.164
更新日期:1999-01-01 00:00:00
abstract::Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0185-1
更新日期:2011-02-01 00:00:00
abstract::We describe the development of experimental platforms to quantify the regeneration of injured central nervous system (CNS) neurons by combining engineering technologies and primary neuronal cultures. Although the regeneration of CNS neurons is an important area of research, there are no currently available methods to ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-012-0515-6
更新日期:2012-06-01 00:00:00
abstract::Optoelectronic plethysmography (OEP) is a noninvasive method for assessing lung volume variations and the contributions of different anatomical compartments of the chest wall (CW) through measurements of the motion of markers attached to the CW surface. The present study proposes a new method for analyzing the local C...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1840-6
更新日期:2017-08-01 00:00:00
abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02684186
更新日期:1997-05-01 00:00:00
abstract::High density particle image velocimetry, with spatial resolution of O(1 mm), was used to measure the effect of occluder rebound on the flow field near a Bjork-Shiley Monostrut tilting-disk mitral valve. The ability to measure two velocity components over an entire plane simultaneously provides a very different insight...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.281
更新日期:2000-04-01 00:00:00
abstract::The induction of angiogenesis is a promising therapeutic strategy for the amelioration of peripheral arterial disease (PAD). This occlusive disease results in muscle ischemia, and neovascularization is a route to increasing the perfusion in the tissue. The vascular endothelial growth factor (VEGF) family of potent pro...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9303-0
更新日期:2007-06-01 00:00:00
abstract::Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1688-1
更新日期:2016-12-01 00:00:00
abstract::In this paper, we aim to establish a new mathematical model that relates pulse wave velocity (PWV) to blood pressure (BP) for continuous and noninvasive BP measurement. For the first time, we derive an ordinary differential equation (ODE) expressing the fundamental relation between BP, elastic modulus G and PWV. The g...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9759-1
更新日期:2009-11-01 00:00:00
abstract::The measurement of CO2 volume exhaled per breath (VCO2.br) can be determined during anesthesia by the multiplication and integration of tidal flow (V) and PCO2. During side-stream capnometry, PCO2 must be advanced in time by transport delay (TD), the time to suction gas through the sampling tube. During ventilation, T...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02738547
更新日期:1997-01-01 00:00:00
abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-016-1678-3
更新日期:2017-01-01 00:00:00
abstract::Spine musculoskeletal models used to estimate loads and displacements require many simplifying assumptions. We examined how assumptions about subject size and vertebral positions can affect the model outcomes. Head and neck models were developed to represent 30 subjects (15 males and 15 females) in neutral posture and...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1007/s10439-018-2084-9
更新日期:2018-11-01 00:00:00
abstract::The pupil diameter (PD), controlled by the autonomic nervous system, seems to provide a strong indication of affective arousal, as found by previous research, but it has not been investigated fully yet. In this study, new approaches based on monitoring and processing the PD signal for off-line and on-line "relaxation"...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0880-9
更新日期:2014-01-01 00:00:00
abstract::Understanding the complex spatiotemporal dynamics of action potential propagation in the heart during arrhythmia is exceedingly difficult. This study applies nonlinear dynamics tools to simplify this task. Using the results of a simulation of an electrical induction of reentry in a sheet of myocardium represented as a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1581289
更新日期:2003-07-01 00:00:00
abstract::To meet demands of vascular reconstruction, there is a need for prosthetic alternatives to natural blood vessels. Here we explored a new conduit fabrication approach. Macroporous, gelatin microcarriers laden with human umbilical vein endothelial cells and aortic smooth muscle cells were dispensed into tubular agarose ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0883-6
更新日期:2014-07-01 00:00:00
abstract::In previous shoulder impact studies, the 50th-percentile male GHBMC human body finite-element model was shown to have good biofidelity regarding impact force, but under-predicted shoulder deflection by 80% compared to those observed in the experiment. The goal of this study was to validate the response of the GHBMC M5...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1546-6
更新日期:2016-08-01 00:00:00
abstract::Measurement of cell shortening is an important technique for assessment of physiology and pathophysiology of cardiac myocytes. Many types of heart disease are associated with decreased myocyte shortening, which is commonly caused by structural and functional remodeling. Here, we present a new approach for local measur...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1593-7
更新日期:2016-10-01 00:00:00
abstract::While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registratio...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02113-z
更新日期:2018-12-01 00:00:00
abstract::Electrospinning was used in innovative electrospinning rigs to obtain tubular and flat fibrous structures with controlled fiber orientation with the aim to be used as scaffolds for biomedical applications, more specifically in the tissue engineering of vascular and orthopedic grafts. Gelatine and hydroxyapatite (HA)-g...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0350-1
更新日期:2011-10-01 00:00:00
abstract::Pressure ulcer risk assessment might be optimized by incorporating the soft tissue reaction to mechanical loading in the currently used risk assessment scales. Cytokines, like IL-1alpha, IL-1RA, IL-8, and TNF-alpha, might be used to determine this tissue reaction, since they are released after 24 h of mechanical loadi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9652-y
更新日期:2009-05-01 00:00:00
abstract::A solid tumor is composed of a population of cells that is expanding as a result of cell division. With dense cell packing, the solid matrix of the interstitial tissue is subject to residual stress. In addition, elevated interstitial fluid pressure (IFP) has been reported by researchers for a number of solid tumors. T...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1554923
更新日期:2003-03-01 00:00:00
abstract::This paper outlines a comprehensive parametric approach for quantifying mechanical properties of spatially heterogeneous thin biological specimens such as human breast tissue using contact-mode Atomic Force Microscopy. Using inverse finite element (FE) analysis of spherical nanoindentation, the force response from hyp...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1057-x
更新日期:2014-09-01 00:00:00
abstract::A method of investigating head acceleration and intracranial dynamics from stick impacts in girls' and women's lacrosse was developed using headform impact experiments and a finite element head model. Assessing the likelihood of head injury due to stick-head impacts is of interest in girls' and women's lacrosse due to...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1091-8
更新日期:2014-12-01 00:00:00
abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9530-z
更新日期:2008-09-01 00:00:00
abstract::A wide range of length and time scales are relevant to pharmacology, especially in drug development, drug design and drug delivery. Therefore, multiscale computational modeling and simulation methods and paradigms that advance the linkage of phenomena occurring at these multiple scales have become increasingly importa...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-016-1563-0
更新日期:2016-09-01 00:00:00
abstract::Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid-structure interaction (FSI) models...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02655-1
更新日期:2020-10-20 00:00:00
abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1447-8
更新日期:2016-02-01 00:00:00
abstract::Arteries are composed of multiple constituents that endow the wall with proper structure and function. Many vascular diseases are associated with prominent mechanical and biological alterations in the wall constituents. In this study, planar biaxial tensile test data of elastase-treated porcine aortic tissue (Chow et ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0733-y
更新日期:2013-07-01 00:00:00
abstract::Gas bubble motion in a blood vessel causes temporal and spatial gradients of shear stress at the cell surface lining the vessel wall as the bubble approaches the cell, moves over it and passes it by. Rapid reversals occur in the sign of the shear stress imparted to the cell surface during this motion. These may result...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0120-5
更新日期:2010-12-01 00:00:00