Evaluating the Impact of Calcification on Plaque Vulnerability from the Aspect of Mechanical Interaction Between Blood Flow and Artery Based on MRI.

Abstract:

:Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid-structure interaction (FSI) models. Six patients with calcified carotid atherosclerosis underwent multisequence magnetic resonance imaging (MRI) and were divided into three groups according to the calcification volume. To evaluate the role of the calcification deposition on the stresses, the calcification content was replaced by lipids and arterial tissue, respectively. By comparing the results from the simulation with calcification, and when changing it to lipids there was a significant increment in the stresses at the fibrous cap (p = 0.004). Instead, by changing it to arterial tissue, there was no significant difference (p = 0.07). The calcification shapes that presented the highest stresses were thin concave arc-shaped (AS1) and thin convex arc-shaped (AS3), with mean stress values of 107 ± 54.2 and 99.6 ± 23.4 kPa, respectively. It was also observed that, the calcification shape has more influence on the level of stress than its distance to the lumen. Higher WSS values were associated with the presence of calcification. Calcification shape plays an important role in producing high stresses in the plaque. This work further clarifies the impact of calcification on plaque vulnerability.

journal_name

Ann Biomed Eng

authors

Benitez J,Fontanarosa D,Wang J,Paritala PK,McGahan T,Lloyd T,Li Z

doi

10.1007/s10439-020-02655-1

subject

Has Abstract

pub_date

2020-10-20 00:00:00

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-020-02655-1

pub_type

杂志文章
  • Intelligent multichannel stimulator for the study of cardiac arrhythmias.

    abstract::An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1451077

    authors: Johnson PL,Newton JC,Rollins DL,Knisley SB,Ideker RE,Smith WM

    更新日期:2002-02-01 00:00:00

  • Multifunctional FePt nanoparticles for radiation-guided targeting and imaging of cancer.

    abstract::A multifunctional FePt nanoparticle was developed that targets tumor microvasculature via "radiation-guided" peptides, and is detected by both near-infrared (NIR) fluorescence imaging and analytical mass spectrometry methods. Tumor specific binding was first measured by biotinylated peptide linked to fluorophore-conju...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0219-8

    authors: Hariri G,Wellons MS,Morris WH 3rd,Lukehart CM,Hallahan DE

    更新日期:2011-03-01 00:00:00

  • Quantification of rigidity in Parkinson's disease.

    abstract::In this paper, a new method for quantification of rigidity in elbow joint of Parkinsonian patients is introduced. One of the most known syndromes in Parkinson's disease (PD) is increased passive stiffness in muscles, which leads to rigidity in joints. Clinical evaluation of stiffness in wrist and/or elbow, commonly us...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9379-6

    authors: Sepehri B,Esteki A,Ebrahimi-Takamjani E,Shahidi GA,Khamseh F,Moinodin M

    更新日期:2007-12-01 00:00:00

  • Arterial wave propagation phenomena, ventricular work, and power dissipation.

    abstract::The effects of wave propagation phenomena, namely global reflection coefficient (gamma G[omega]) and pulse wave velocity (Cph), are studied in a model of the coupled left ventricle/arterial system. The left ventricle consists of a time-varying elastance, while the arterial system is modeled as a single, uniform, elast...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584479

    authors: Berger DS,Li JK,Noordergraaf A

    更新日期:1995-11-01 00:00:00

  • Design Optimisation of Coronary Artery Stent Systems.

    abstract::In recent years, advances in computing power and computational methods have made it possible to perform detailed simulations of the coronary artery stenting procedure and of related virtual tests of performance (including fatigue resistance, corrosion and haemodynamic disturbance). Simultaneously, there has been a gro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1373-9

    authors: Bressloff NW,Ragkousis G,Curzen N

    更新日期:2016-02-01 00:00:00

  • Development of gradient descent adaptive algorithms to remove common mode artifact for improvement of cardiovascular signal quality.

    abstract:BACKGROUND:Common-mode noise degrades cardiovascular signal quality and diminishes measurement accuracy. Filtering to remove noise components in the frequency domain often distorts the signal. METHOD:Two adaptive noise canceling (ANC) algorithms were tested to adjust weighted reference signals for optimal subtraction ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9294-x

    authors: Ciaccio EJ,Micheli-Tzanakou E

    更新日期:2007-07-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • A numerical implementation to predict residual strains from the homogeneous stress hypothesis with application to abdominal aortic aneurysms.

    abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0749-y

    authors: Polzer S,Bursa J,Gasser TC,Staffa R,Vlachovsky R

    更新日期:2013-07-01 00:00:00

  • Analyzing trends in brain interface technology: a method to compare studies.

    abstract::Continued progress in the field of Brain Interface (BI) research has encouraged the rapid expansion of the BI community over the last two decades. As the number of BI researchers and organizations steadily increases, newer and more advanced technologies are constantly produced, evaluated, and reported. Though the BI c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9055-7

    authors: Jackson MM,Mason SG,Birch GE

    更新日期:2006-05-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Quasiperiodic circus movement in a loop model of cardiac tissue: multistability and low dimensional equivalence.

    abstract::This paper discusses the dynamics of the circus movement around a one-dimensional continuous and uniform loop of model cardiac cells. The membrane ionic currents are represented by a modified Beeler-Reuter formulation. The description of the quasiperiodic regimes initiated in a previous paper is completed and their eq...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1289458

    authors: Vinet A

    更新日期:2000-07-01 00:00:00

  • A Fluorescence Sensing Method with Reduced DNA Typing and Low-Cost Instrumentation for Detection of Sample Tampering Cases in Urinalysis.

    abstract::This work presents a method to unequivocally detect urine sample tampering in cases where integrity of the sample needs to be verified prior to urinalysis. The technique involves the detection of distinct patterns of a triplex short tandem repeats system in DNA extracted from human urine. The analysis is realized with...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02386-y

    authors: Pires NMM,Dong T,Yang Z,Santos SMB

    更新日期:2020-02-01 00:00:00

  • Design considerations for a microfluidic device to quantify the platelet adhesion to collagen at physiological shear rates.

    abstract::Accurate assessment of blood platelet function is essential in understanding thrombus formation which plays a central role in cardiovascular disease. Parallel plate flow chambers have been widely used as they allow for platelet adhesion on a collagen surface at physiologically relevant fluid mechanical forces. Standar...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9708-z

    authors: Sarvepalli DP,Schmidtke DW,Nollert MU

    更新日期:2009-07-01 00:00:00

  • A new bioreactor for the development of tissue-engineered heart valves.

    abstract::This paper reports the design, manufacturing, and characterization of a new bioreactor dedicated to the development of tissue-engineered heart valve substitutes. First, a comprehensive review of the state of the art in bioreactors is presented and a rigorous classification is put forward. The existing bioreactors foun...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9646-9

    authors: Ruel J,Lachance G

    更新日期:2009-04-01 00:00:00

  • An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve.

    abstract::The most widely implanted prosthetic valve is the mechanical bileaflet. Recent clinical experiences suggest that some designs are more prone to thromboembolic episodes than others. This study evaluated the hinge flow and near-field forward flow of the new St. Jude Medical Regent bileaflet mechanical heart valve. Laser...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.297

    authors: Ellis JT,Travis BR,Yoganathan AP

    更新日期:2000-05-01 00:00:00

  • A computer reconstruction of the entire coronary arterial tree based on detailed morphometric data.

    abstract::A rigorous analysis of blood flow must be based on the branching pattern and vascular geometry of the full vascular circuit of interest. It is experimentally difficult to reconstruct the entire vascular circuit of any organ because of the enormity of the vessels. The objective of the present study was to develop a nov...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5758-z

    authors: Mittal N,Zhou Y,Ung S,Linares C,Molloi S,Kassab GS

    更新日期:2005-08-01 00:00:00

  • An analysis of hypoxia in sheep brain using a mathematical model.

    abstract::Cerebral blood flow (CBF) increases as arterial oxygen content falls with hypoxic (low PO2), anemic (low hemoglobin) and carbon monoxide (CO) (high carboxyhemoglobin) hypoxia. Despite a higher arterial PO2, CO hypoxia provokes a greater increase in CBF than hypoxic hypoxia. We analyzed published data using a compartme...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.50

    authors: Sharan M,Popel AS,Hudak ML,Koehler RC,Traystman RJ,Jones MD Jr

    更新日期:1998-01-01 00:00:00

  • Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard.

    abstract::Predictions from biomechanical models of gait may be sensitive to joint center locations. Most often, the hip joint center (HJC) is derived from locations of reflective markers adhered to the skin. Here, predictive techniques use regression equations of pelvic anatomy to estimate the HJC, whereas functional methods tr...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-015-1522-1

    authors: Fiorentino NM,Kutschke MJ,Atkins PR,Foreman KB,Kapron AL,Anderson AE

    更新日期:2016-07-01 00:00:00

  • Mechanical Performance of Two Left Atrial Appendage Occlusion Systems: In Vitro Comparison of Tug Force, Radial Force, Sealing and Deformation.

    abstract::The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech®, of three different sizes underwent testing in novel dedicated in vitro setups. Radial force wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2057-z

    authors: Menne MF,Schrickel JW,Nickenig G,Al-Kassou B,Nelles D,Schmitz-Rode T,Steinseifer U,Sedaghat A

    更新日期:2018-09-01 00:00:00

  • The impedance of a spherical monopolar electrode.

    abstract::The impedance of a monopolar electrode immersed in an environmental volume conductor consists of two parts; the impedance of the active electrode-electrolyte interface, and the resistance of the environmental conductor. Two studies were carried out to quantitate these components. First, impedance-frequency data were c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368609

    authors: Ragheb T,Riegle S,Geddes LA,Amin V

    更新日期:1992-01-01 00:00:00

  • Reporter Scaffolds for Clinically Relevant Cell Transplantation Studies.

    abstract::There are a number of cell therapies that are either in clinical trials or moving toward clinical trials, particularly for diseases of the retina. One of the challenges with cell therapies is tracking the status of cells over time. Genetic manipulation can facilitate this, but it can limit the clinical application of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02393-z

    authors: Bolger M,Groynom R,Bogie K,Lavik E

    更新日期:2020-07-01 00:00:00

  • Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

    abstract::This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0840-4

    authors: Wright GJ,Kuo J,Shi C,Bacro TR,Slate EH,Yao H

    更新日期:2013-11-01 00:00:00

  • Fractal character of pulmonary microvascular permeability.

    abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368425

    authors: McNamee JE

    更新日期:1990-01-01 00:00:00

  • Second harmonic generation imaging and Fourier transform spectral analysis reveal damage in fatigue-loaded tendons.

    abstract::Conventional histologic methods provide valuable information regarding the physical nature of damage in fatigue-loaded tendons, limited to thin, two-dimensional sections. We introduce an imaging method that characterizes tendon microstructure three-dimensionally and develop quantitative, spatial measures of damage for...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9976-7

    authors: Fung DT,Sereysky JB,Basta-Pljakic J,Laudier DM,Huq R,Jepsen KJ,Schaffler MB,Flatow EL

    更新日期:2010-05-01 00:00:00

  • LDL decreases the membrane compliance and cell adhesion of endothelial cells under fluid shear stress.

    abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0677-2

    authors: Wei D,Chen Y,Tang C,Huang H,Liu L,Wang Z,Li R,Wang G

    更新日期:2013-03-01 00:00:00

  • The transport profile of cytokines in epidermal equivalents subjected to mechanical loading.

    abstract::Pressure ulcer risk assessment might be optimized by incorporating the soft tissue reaction to mechanical loading in the currently used risk assessment scales. Cytokines, like IL-1alpha, IL-1RA, IL-8, and TNF-alpha, might be used to determine this tissue reaction, since they are released after 24 h of mechanical loadi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9652-y

    authors: Cornelissen LH,Bronneberg D,Bader DL,Baaijens FP,Oomens CW

    更新日期:2009-05-01 00:00:00

  • Stereolithography 3D Bioprinting Method for Fabrication of Human Corneal Stroma Equivalent.

    abstract::3D bioprinting technology is a promising approach for corneal stromal tissue regeneration. In this study, gelatin methacrylate (GelMA) mixed with corneal stromal cells was used as a bioink. The visible light-based stereolithography (SLA) 3D bioprinting method was utilized to print the anatomically similar dome-shaped ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02537-6

    authors: Mahdavi SS,Abdekhodaie MJ,Kumar H,Mashayekhan S,Baradaran-Rafii A,Kim K

    更新日期:2020-07-01 00:00:00

  • An experimental evaluation of the use of an ensemble average for the calculation of turbulence in pulsatile flow.

    abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584215

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1983-01-01 00:00:00

  • Microvascular endothelial cells exhibit optimal aspect ratio for minimizing flow resistance.

    abstract::A recent analytical solution of the three-dimensional Stokes flow through a bumpy tube predicts that for a given bump area, there exists an optimal circumferential wavenumber which minimizes flow resistance. This study uses measurements of microvessel endothelial cell morphology to test whether this prediction holds i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9467-2

    authors: Sumagin R,Brown CW 3rd,Sarelius IH,King MR

    更新日期:2008-04-01 00:00:00

  • Cellular and Nuclear Alignment Analysis for Determining Epithelial Cell Chirality.

    abstract::Left-right (LR) asymmetry is a biologically conserved property in living organisms that can be observed in the asymmetrical arrangement of organs and tissues and in tissue morphogenesis, such as the directional looping of the gastrointestinal tract and heart. The expression of LR asymmetry in embryonic tissues can be ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1431-3

    authors: Raymond MJ Jr,Ray P,Kaur G,Singh AV,Wan LQ

    更新日期:2016-05-01 00:00:00