The impedance of a spherical monopolar electrode.

Abstract:

:The impedance of a monopolar electrode immersed in an environmental volume conductor consists of two parts; the impedance of the active electrode-electrolyte interface, and the resistance of the environmental conductor. Two studies were carried out to quantitate these components. First, impedance-frequency data were collected for five spherical stainless-steel electrodes (ranging from 0.473 to 1.11 cm in diameter) immersed in 0.9% saline (p = 70 omega-cm). Impedance measurements were made from 100 Hz to 100 kHz and two sets of data were obtained; one before and one after each electrode was polished with fine emery paper. At low frequency, the measured impedances were high and varied with electrode surface preparation. However, above a transition frequency, the impedances were resistive, independent of the electrode surface preparation, and equal to rho/2 pi d as predicted from the theory. This study indicates that the low frequency impedance of a monopolar electrode is dominated by the impedance of the electrode-electrolyte interface. Above a transition frequency, the resistance of the environmental conductor dominates, the value of this resistance depending on the electrode geometry and the resistivity (rho) of the environmental conductor. A second study was conducted, to examine the effect of the distance to the indifferent electrode. A frequency (100 kHz) above the transition frequency was used and impedance data were collected for various distances between the monopolar and indifferent electrodes. The measured resistance increased asymptotically as the distance between the electrodes was increased. When the indifferent electrode diameter was at least 10 times the diameter of the spherical monopolar electrode, the measured resistance was within 5% of the value predicted for an indifferent electrode at infinity.

journal_name

Ann Biomed Eng

authors

Ragheb T,Riegle S,Geddes LA,Amin V

doi

10.1007/BF02368609

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

617-27

issue

6

eissn

0090-6964

issn

1573-9686

journal_volume

20

pub_type

杂志文章
  • Static magnetic fields promote osteoblast-like cells differentiation via increasing the membrane rigidity.

    abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9370-2

    authors: Chiu KH,Ou KL,Lee SY,Lin CT,Chang WJ,Chen CC,Huang HM

    更新日期:2007-11-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves.

    abstract::This study was aimed at developing a physical model, supported by experimental observations, to describe the formation and growth of microbubbles seen in patients with mitral mechanical heart valves (MHV). This phenomenon, often referred to as high intensity transient signals (HITS), appears as bright, intense, high-v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.231

    authors: Rambod E,Beizaie M,Shusser M,Milo S,Gharib M

    更新日期:1999-11-01 00:00:00

  • In Silico Investigation of Angiogenesis with Growth and Stress Generation Coupled to Local Extracellular Matrix Density.

    abstract::Mechanical interactions during angiogenesis, i.e., traction applied by neovessels to the extracellular matrix and the corresponding deformation, are important regulators of growth and neovascularization. We have previously designed, implemented, and validated a coupled model of angiogenesis in which a discrete microve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1334-3

    authors: Edgar LT,Hoying JB,Weiss JA

    更新日期:2015-07-01 00:00:00

  • Dynamics of cardiac period responses after prolonged vagal stimulation in the dog.

    abstract::In 12 dogs anesthetised with alpha-chloralose and urethane, and beta-adrenergic blocked with propranolol, the cervical vagi were stimulated for 60 seconds with supramaximal constant current pulses at frequencies between 2.0 and 10 Hz. The time course of the recovery of the cardiac period response, after cessation of v...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584303

    authors: Celler BG,Lovell NH

    更新日期:1991-01-01 00:00:00

  • Dual energy CT scanning for analysis of brain damage due to X-irradiation.

    abstract::Therapeutic irradiation is commonly used in the treatment of malignant brain tumors and has the potential to cause severe injury to normal tissues adjacent to a lesion. Computed tomography (CT) can be used not only to visualize tissue damage but to monitor the development of a lesion using advanced quantitative CT tec...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410288

    authors: Russell LB,Fike JR,Cann CE,Süsskind C

    更新日期:1984-01-01 00:00:00

  • Mathematical simulation of slowing of cardiac conduction velocity by elevated extracellular.

    abstract::We have studied the dependence of conduction velocity (theta) on extracellular potassium concentration ([K+]o) in a model of one-dimensional conduction using an idealized strand of human atrial cells. Elevated [K+]o in the 5-20 mM range shifts the resting potential (Vrest) in the depolarizing direction and reduces inp...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1308489

    authors: Nygren A,Giles WR

    更新日期:2000-08-01 00:00:00

  • Development of a Platform for Studying 3D Astrocyte Mechanobiology: Compression of Astrocytes in Collagen Gels.

    abstract::Glaucoma is a common optic neuropathy characterized by retinal ganglion cell death. Elevated intraocular pressure (IOP), a key risk factor for glaucoma, leads to significant biomechanical deformation of optic nerve head (ONH) cells and tissues. ONH astrocytes respond to this deformation by transforming to a reactive, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1967-5

    authors: Mulvihill JJE,Raykin J,Snider EJ,Schildmeyer LA,Zaman I,Platt MO,Kelly DJ,Ethier CR

    更新日期:2018-02-01 00:00:00

  • Developing a quantitative measurement system for assessing heterotopic ossification and monitoring the bioelectric metrics from electrically induced osseointegration in the residual limb of service members.

    abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0050-2

    authors: Isaacson BM,Stinstra JG,MacLeod RS,Pasquina PF,Bloebaum RD

    更新日期:2010-09-01 00:00:00

  • A review of approaches to mobility telemonitoring of the elderly in their living environment.

    abstract::Rapid technological advances have prompted the development of a wide range of telemonitoring systems to enable the prevention, early diagnosis and management, of chronic conditions. Remote monitoring can reduce the amount of recurring admissions to hospital, facilitate more efficient clinical visits with objective res...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-9068-2

    authors: Ní Scanaill C,Carew S,Barralon P,Noury N,Lyons D,Lyons GM

    更新日期:2006-04-01 00:00:00

  • An artificial neural network approach to the predictive modeling of tensile force during renal suturing.

    abstract::Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deform...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0722-1

    authors: Yu D,Qing Y,Jianxun Z,Jun D

    更新日期:2013-04-01 00:00:00

  • Biomechanical topography of human ankle cartilage.

    abstract::The material properties of normal cadaveric human cartilage in the ankle mortice (tibiotalar articulation) were evaluated to determine a possible etiologic mechanism of cartilage injury of the ankle when an obvious traumatic episode is not present. Using an automated indentation apparatus and the biphasic creep indent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584467

    authors: Athanasiou KA,Niederauer GG,Schenck RC Jr

    更新日期:1995-09-01 00:00:00

  • The role of sugars in dendritic cell trafficking.

    abstract::Dendritic cells (DCs) are crucial components of the immune response, strategically positioned as immune sentinels. Complex trafficking and accurate positioning of DCs are indispensable for both immunity and tolerance. This is particularly evident for their therapeutic application where an unmet clinical need exists fo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0448-5

    authors: Silva Z,Konstantopoulos K,Videira PA

    更新日期:2012-04-01 00:00:00

  • High-resolution measurement of the unsteady velocity field to evaluate blood damage induced by a mechanical heart valve.

    abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0329-y

    authors: Bellofiore A,Quinlan NJ

    更新日期:2011-09-01 00:00:00

  • Novel approach for endothelializing vascular devices: understanding and exploiting elastin-endothelial interactions.

    abstract::Elastin is an essential component of arteries which provides structural integrity and instructs smooth muscle cells to adopt a quiescent state. Despite interaction of endothelial cells with elastin in the internal elastic lamina, the potential for exploiting this interaction therapeutically has not been explored in de...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0142-z

    authors: Wilson BD,Gibson CC,Sorensen LK,Guilhermier MY,Clinger M,Kelley LL,Shiu YT,Li DY

    更新日期:2011-01-01 00:00:00

  • In-Vitro Detection of Small Isolated Cartilage Defects: Intravascular Ultrasound Vs. Optical Coherence Tomography.

    abstract::This experimental work focused on the sensor selection for the development of a needle-like instrument to treat small isolated cartilage defects with hydrogels. The aim was to identify the most accurate and sensitive imaging method to determine the location and size of defects compared to a gold standard (µCT). Only i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2073-z

    authors: Horeman T,Buiter EC,Pouran B,Stijntjes M,Dankelman J,Tuijthof GJM

    更新日期:2018-11-01 00:00:00

  • A model of electrical conduction in cardiac tissue including fibroblasts.

    abstract::Fibroblasts are abundant in cardiac tissue. Experimental studies suggested that fibroblasts are electrically coupled to myocytes and this coupling can impact cardiac electrophysiology. In this work, we present a novel approach for mathematical modeling of electrical conduction in cardiac tissue composed of myocytes, f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9667-4

    authors: Sachse FB,Moreno AP,Seemann G,Abildskov JA

    更新日期:2009-05-01 00:00:00

  • Multi-Dimensional Nanostructures for Microfluidic Screening of Biomarkers: From Molecular Separation to Cancer Cell Detection.

    abstract::Rapid screening of biomarkers, with high specificity and accuracy, is critical for many point-of-care diagnostics. Microfluidics, the use of microscale channels to manipulate small liquid samples and carry reactions in parallel, offers tremendous opportunities to address fundamental questions in biology and provide a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1521-2

    authors: Ng E,Chen K,Hang A,Syed A,Zhang JX

    更新日期:2016-04-01 00:00:00

  • Low Impedance Carbon Adhesive Electrodes with Long Shelf Life.

    abstract::A novel electrocardiogram (ECG) electrode film is developed by mixing carbon black powder and a quaternary salt with a visco-elastic polymeric adhesive. Unlike traditional wet gel-based electrodes, carbon/salt/adhesive (CSA) electrodes should theoretically have an infinite shelf life as they do not dehydrate even afte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1282-y

    authors: Posada-Quintero HF,Reyes BA,Burnham K,Pennace J,Chon KH

    更新日期:2015-10-01 00:00:00

  • Sensitivity of indentation testing to step-off edges and interface integrity in cartilage repair.

    abstract::Step-off edges and tissue interfaces are prevalent in cartilage injury such as after intra-articular fracture and reduction, and in focal defects and surgical repair procedures such as osteochondral graft implantation. It would be useful to assess the function of injured or donor tissues near such step-off edges and t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000017553.01798.12

    authors: Bae WC,Law AW,Amiel D,Sah RL

    更新日期:2004-03-01 00:00:00

  • A microcomputer oxygen control system for ventilatory therapy.

    abstract::A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368173

    authors: Tehrani FT

    更新日期:1992-01-01 00:00:00

  • Stenosis Hemodynamics Disrupt the Endothelial Cell Glycocalyx by MMP Activity Creating a Proinflammatory Environment.

    abstract::Hemodynamic forces are known to be able to induce an inflammatory phenotype in endothelial cells (ECs). The EC glycocalyx (GCX) is a dynamic structure which is regulated in response to different stimuli and hypothesized as an important contributor to the mechanotransduction of wall shear stresses (WSS). In this work, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1846-0

    authors: Cooper S,McDonald K,Burkat D,Leask RL

    更新日期:2017-09-01 00:00:00

  • An inverse approach to determine solute and solvent permeability parameters in artificial tissues.

    abstract::This study presents a generic numerical model to simulate the coupled solute and solvent transport in tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA; dimethylsulfoxide or DMSO). Osmotic responses of various tissue cells within the artificial tissue are predicted by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1511-x

    authors: He Y,Devireddy RV

    更新日期:2005-05-01 00:00:00

  • On the Impact of Intraluminal Thrombus Mechanical Behavior in AAA Passive Mechanics.

    abstract::Intraluminal thrombus (ILT) is a pseudo-tissue that develops from coagulated blood, and is found in most abdominal aortic aneurysms (AAAs) of clinically relevant size. A number of studies have suggested that ILT mechanical characteristics may be related to AAA risk of rupture, even though there is still great controve...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1267-x

    authors: Riveros F,Martufi G,Gasser TC,Rodriguez-Matas JF

    更新日期:2015-09-01 00:00:00

  • Analytical Modelling of Natural Frequency of Tympanic Membrane as the Low-Frequency Limit of Hearing.

    abstract::We examine the low-frequency limit of hearing of the mammalian ear through the analytical modelling of the natural frequency of the tympanic membrane. The resulting equation of the natural frequency of the modelled tympanic membrane is numerically verified against previous theoretical studies, and is statistically val...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02356-4

    authors: Jabaraj DJ

    更新日期:2020-01-01 00:00:00

  • The Role of Synthetic Extracellular Matrices in Endothelial Progenitor Cell Homing for Treatment of Vascular Disease.

    abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-015-1400-x

    authors: Williams PA,Silva EA

    更新日期:2015-10-01 00:00:00

  • Bymixer provides on-line calibration of measurement of CO2 volume exhaled per breath.

    abstract::The measurement of CO2 volume exhaled per breath (VCO2.br) can be determined during anesthesia by the multiplication and integration of tidal flow (V) and PCO2. During side-stream capnometry, PCO2 must be advanced in time by transport delay (TD), the time to suction gas through the sampling tube. During ventilation, T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738547

    authors: Breen PH,Serina ER

    更新日期:1997-01-01 00:00:00

  • Consistent biomechanical phenotyping of common carotid arteries from seven genetic, pharmacological, and surgical mouse models.

    abstract::The continuing lack of longitudinal histopathological and biomechanical data for human arteries in health and disease highlights the importance of studying the many genetic, pharmacological, and surgical models that are available in mice. As a result, there has been a significant increase in the number of reports on t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0988-6

    authors: Bersi MR,Ferruzzi J,Eberth JF,Gleason RL Jr,Humphrey JD

    更新日期:2014-06-01 00:00:00

  • Effects of crowding on the thermal stability of heterogeneous protein solutions.

    abstract::Crowding can substantially affect the transition of a protein between its native (N) and unfolded (U) states via volume exclusion effects. Also, it influences considerably the aggregation (A) of unfolded proteins. To examine the details, we developed an approach for computing the kinetic rates of the process N <--> U ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5780-8

    authors: Despa F,Orgill DP,Lee RC

    更新日期:2005-08-01 00:00:00

  • Electrically active bioceramics: a review of interfacial responses.

    abstract::Electrical potentials in mechanically loaded bone have been implicated as signals in the bone remodeling cycle. Recently, interest has grown in exploiting this phenomenon to develop electrically active ceramics for implantation in hard tissue which may induce improved biological responses. Both polarized hydroxyapatit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9977-6

    authors: Baxter FR,Bowen CR,Turner IG,Dent AC

    更新日期:2010-06-01 00:00:00