Abstract:
:Further understanding of the mechanical deformation and tear behavior of kidney during suturing helps to enhance surgical task execution that requires fine suture manipulation. This paper aims to develop a model to describe the relationship between the tensile force acting on suture line and the resulted kidney deformation in the tension of suture line. The tensile force was recorded during multiple suture procedures, filtered, and we extracted the force data between the beginnings of tensioning suture line and tearing renal remnant. The extracted data were interpolated to obtain the same data sample length for each suture procedure, and then used to train the back propagation (BP) neural network. In order to predict the tearing force, force data were collected in sequence and interpolated to be input into BP network. Suture processes were performed on in vitro porcine kidneys, and experimental results verified the effectiveness of predictive modeling and the accuracy of tearing force prediction. The relative error for tearing force prediction was about 15%. The predictive modeling method can be used to forecast the tearing force before the suture line tears through soft tissues.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Yu D,Qing Y,Jianxun Z,Jun Ddoi
10.1007/s10439-012-0722-1subject
Has Abstractpub_date
2013-04-01 00:00:00pages
786-94issue
4eissn
0090-6964issn
1573-9686journal_volume
41pub_type
杂志文章abstract::The objective of this work is to develop understanding of the local fluid dynamic mechanisms that underpin gas exchange in high-frequency oscillatory ventilation (HFOV). The flow field during HFOV was investigated experimentally using particle image velocimetry in idealized and realistic models of a single bifurcation...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9557-1
更新日期:2008-11-01 00:00:00
abstract::Fibroblasts are abundant in cardiac tissue. Experimental studies suggested that fibroblasts are electrically coupled to myocytes and this coupling can impact cardiac electrophysiology. In this work, we present a novel approach for mathematical modeling of electrical conduction in cardiac tissue composed of myocytes, f...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9667-4
更新日期:2009-05-01 00:00:00
abstract::The emerging field of micro-technology has opened up new possibilities for exploring cellular chemotaxis in real space and time, and at single cell resolution. Chemotactic cells sense and move in response to chemical gradients and play important roles in a number of physiological and pathological processes, including ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-011-0489-9
更新日期:2012-06-01 00:00:00
abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0802-x
更新日期:2013-10-01 00:00:00
abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1075-8
更新日期:2015-01-01 00:00:00
abstract::Poor prosthetic fit is often the result of heterotopic ossification (HO), a frequent problem following blast injuries for returning service members. Osseointegration technology offers an advantage for individuals with significant HO and poor socket tolerance by using direct skeletal attachment of a prosthesis to the d...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0050-2
更新日期:2010-09-01 00:00:00
abstract::For several years, Virginia Tech and other schools have measured the frequency and severity of head impacts sustained by collegiate American football players in real time using the Head Impact Telemetry (HIT) System of helmet-mounted accelerometers. In this study, data from 37,128 head impacts collected at Virginia Te...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0400-8
更新日期:2012-01-01 00:00:00
abstract::Deformational loading represents a primary component of the chondrocyte physical environment in vivo. This review summarizes our experience with physiologic deformational loading of chondrocyte-seeded agarose hydrogels to promote development of cartilage constructs having mechanical properties matching that of the par...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1023/b:abme.0000007789.99565.42
更新日期:2004-01-01 00:00:00
abstract::This study presents a generic numerical model to simulate the coupled solute and solvent transport in tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA; dimethylsulfoxide or DMSO). Osmotic responses of various tissue cells within the artificial tissue are predicted by the ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-1511-x
更新日期:2005-05-01 00:00:00
abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1964-8
更新日期:2018-02-01 00:00:00
abstract::Arterial responses to diverse pathologies and insults likely occur via similar mechanisms. For example, many studies suggest that the natural process of aging and isolated systolic hypertension share many characteristics in arteries, including loss of functional elastin, decreased smooth muscle tone, and altered rates...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0287-4
更新日期:2011-07-01 00:00:00
abstract::We propose a mathematical model for analyses of the elastic properties of the wall of the outer hair cell (OHC) in the inner ear. The model reflects the properties of the major components of the OHC wall: the subsurface cisternae, the cortical lattice, the plasma membrane, and the radial pillars. The wall is treated a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.87
更新日期:1998-01-01 00:00:00
abstract::Simulations are useful to study the heart's ability to generate flow and the interaction between contractility and loading conditions. The left ventricular pressure-volume (PV) relation has been shown to be nonlinear, but it is unknown whether a linear model is accurate enough for simulations. Six models were fitted t...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9742-x
更新日期:2009-09-01 00:00:00
abstract::Disease and injury perturb the balance of processes associated with inflammation and tissue remodeling, resulting in positive feedback loops, exacerbation of disease and compromised tissue repair. Conversely, under homeostatic healthy conditions, these processes are tightly regulated through the expansion and/or recru...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-014-1125-2
更新日期:2015-03-01 00:00:00
abstract::Human stem cells hold significant potential for the treatment of various diseases. However, their use as a therapy is hampered because of limited understanding of the mechanisms by which they respond to environmental stimuli. Efforts to understand extracellular biophysical cues have demonstrated the critical roles of ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-2008-8
更新日期:2018-06-01 00:00:00
abstract::Early stage changes in hypertensive arteries have a significant effect on the long-term adaptation of the arteries. Compared to the long-term adaptation, little is known about the early dimensional and functional changes in hypertensive arteries in the first few days of hypertension. To study the early stage changes i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1376391
更新日期:2001-06-01 00:00:00
abstract::This paper presents the permeability analysis of neuroactive drugs and correlation with in vivo brain/plasma ratios in a dynamic microfluidic blood-brain barrier (BBB) model. Permeability of seven neuroactive drugs (Ethosuximide, Gabapentin, Sertraline, Sunitinib, Traxoprodil, Varenicline, PF-304014) and trans-endothe...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1086-5
更新日期:2014-12-01 00:00:00
abstract::In vitro stent-induced thromboembolism was altered by the presence of residual stenoses placed upstream or placed upstream and downstream of the stent. Heparinized (3 micro/ml) bovine blood was gravity fed through a conduit with a deployed coronary stent. Embolism was continuously monitored using a light-scattering mi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.243
更新日期:2000-02-01 00:00:00
abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368320
更新日期:1995-03-01 00:00:00
abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.110
更新日期:1998-09-01 00:00:00
abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0386-2
更新日期:2012-01-01 00:00:00
abstract::Glaucoma is a common optic neuropathy characterized by retinal ganglion cell death. Elevated intraocular pressure (IOP), a key risk factor for glaucoma, leads to significant biomechanical deformation of optic nerve head (ONH) cells and tissues. ONH astrocytes respond to this deformation by transforming to a reactive, ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1967-5
更新日期:2018-02-01 00:00:00
abstract::This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characte...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9689-y
更新日期:2009-06-01 00:00:00
abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9530-z
更新日期:2008-09-01 00:00:00
abstract::A method of investigating head acceleration and intracranial dynamics from stick impacts in girls' and women's lacrosse was developed using headform impact experiments and a finite element head model. Assessing the likelihood of head injury due to stick-head impacts is of interest in girls' and women's lacrosse due to...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1091-8
更新日期:2014-12-01 00:00:00
abstract::Dendritic cell (DC) migration is required for efficient presentation of antigen to T cells and the initiation of an adaptive immune response. In spite of its importance, many aspects of DC migration have not been characterized. DCs encounter a variety of environments with different stiffness and geometry, but the effe...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-2041-7
更新日期:2018-09-01 00:00:00
abstract::During defecation, solid, semisolid or liquid stools are eliminated via the anus in a complex physiological process. Up to 25% of the population are affected by anorectal disorders that are poorly recognized and treated. We developed a new bionics device, a simulated stool named Fecobionics, to replace several current...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02149-1
更新日期:2019-02-01 00:00:00
abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-004-7820-7
更新日期:2004-12-01 00:00:00
abstract::Experimental and diagnostic procedures like distension of a balloon catheter, bougie, and esophagogastroduodenoscopy can induce shear deformation in the esophageal wall. However, the shear modulus of the esophagus is yet unknown. The aim of this study was to determine the esophageal shear modulus and its dependence on...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/b:abme.0000039356.24821.6c
更新日期:2004-09-01 00:00:00
abstract::A computer-based feedback system has been developed to adjust the concentration of oxygen in the inspired gas of a patient under artificial respiration. The system uses a proportional plus integral controller and feedback of arterial oxygen saturation to adjust the inspired oxygen fraction. The effectiveness of the co...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368173
更新日期:1992-01-01 00:00:00