Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.

Abstract:

:This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characteristics and transient characteristics, of the MR-MI simulation were investigated by a numerical experiment. We dealt with reproduction of three-dimensional steady and unsteady blood flow fields in a realistic cerebral aneurysm developed at a bifurcation. The MR-MI simulation reduced the error derived from the incorrect boundary conditions in the blood flow in the cerebral aneurysm. For the reproduction of steady and unsteady standard solutions, the error of velocity decreased to 13% and to 22% in one cardiac cycle, respectively, compared with the ordinary simulation without feedback. Moreover, the application of feedback shortened the computational convergence, and thus the convergent solution and periodic solution were obtained within less computational time in the MR-MI simulation than that in the ordinary simulation. The dividing flow ratio toward the two outlets after bifurcation was well estimated owing to the improvement of computational accuracy. Furthermore, the MR-MI simulation yielded wall shear stress distribution on the cerebral aneurysm of the standard solution accurately and in detail.

journal_name

Ann Biomed Eng

authors

Funamoto K,Suzuki Y,Hayase T,Kosugi T,Isoda H

doi

10.1007/s10439-009-9689-y

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

1105-16

issue

6

eissn

0090-6964

issn

1573-9686

journal_volume

37

pub_type

杂志文章
  • Correction to: A High-Precision and Miniature Fiber Bragg Grating-Based Force Sensor for Tissue Palpation During Minimally Invasive Surgery.

    abstract::The second equation in the section "Definition of Objective Functions and Constraints" was corrected to fix a mismatch between the PDF and HTML versions of the article. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s10439-019-02413-y

    authors: Lv C,Wang S,Shi C

    更新日期:2020-01-01 00:00:00

  • Fluid shifts due to microgravity and their effects on bone: a review of current knowledge.

    abstract::Bone loss during long-term space flight is potentially a significant problem. Bone mineral density measurements show that bone is lost at a rate of about 1% per month from the lumbar spine, and 1.5% per month from the hip. Bone density changes are not uniform throughout the skeleton, and there is accumulating evidence...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-005-8967-6

    authors: McCarthy ID

    更新日期:2005-01-01 00:00:00

  • Therapeutic effects of functional electrical stimulation on gait in individuals post-stroke.

    abstract::Functional electrical stimulation (FES) to lower extremity (LE) muscles is used by individuals post-stroke as an alternative to mechanical orthotic devices during gait or as a training modality during rehabilitation. Technological developments which improve the feasibility, accessibility and effectiveness of FES syste...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1148-8

    authors: Kafri M,Laufer Y

    更新日期:2015-02-01 00:00:00

  • An inverse approach to determine solute and solvent permeability parameters in artificial tissues.

    abstract::This study presents a generic numerical model to simulate the coupled solute and solvent transport in tissue sections during addition and removal of chemical additives or cryoprotective agents (CPA; dimethylsulfoxide or DMSO). Osmotic responses of various tissue cells within the artificial tissue are predicted by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1511-x

    authors: He Y,Devireddy RV

    更新日期:2005-05-01 00:00:00

  • Superparamagnetic iron oxide is suitable to label tendon stem cells and track them in vivo with MR imaging.

    abstract::Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0802-x

    authors: Yang Y,Zhang J,Qian Y,Dong S,Huang H,Boada FE,Fu FH,Wang JH

    更新日期:2013-10-01 00:00:00

  • Evaluating the Impact of Calcification on Plaque Vulnerability from the Aspect of Mechanical Interaction Between Blood Flow and Artery Based on MRI.

    abstract::Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid-structure interaction (FSI) models...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02655-1

    authors: Benitez J,Fontanarosa D,Wang J,Paritala PK,McGahan T,Lloyd T,Li Z

    更新日期:2020-10-20 00:00:00

  • Strength and electron features of irradiated bone.

    abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1424911

    authors: Dekhtyar Y

    更新日期:2001-12-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • Computational study of proteolysis-driven single cell migration in a three-dimensional matrix.

    abstract::Cell migration is a fundamental process that is crucial to a variety of physiological events. While traditional approaches have focused on two-dimensional (2D) systems, recent efforts have shifted to studying migration in three-dimensional (3D) matrices. A major distinction that has emerged is the increased importance...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9970-0

    authors: Harjanto D,Zaman MH

    更新日期:2010-05-01 00:00:00

  • Validation of concussion risk curves for collegiate football players derived from HITS data.

    abstract::For several years, Virginia Tech and other schools have measured the frequency and severity of head impacts sustained by collegiate American football players in real time using the Head Impact Telemetry (HIT) System of helmet-mounted accelerometers. In this study, data from 37,128 head impacts collected at Virginia Te...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0400-8

    authors: Funk JR,Rowson S,Daniel RW,Duma SM

    更新日期:2012-01-01 00:00:00

  • Quasiperiodic circus movement in a loop model of cardiac tissue: multistability and low dimensional equivalence.

    abstract::This paper discusses the dynamics of the circus movement around a one-dimensional continuous and uniform loop of model cardiac cells. The membrane ionic currents are represented by a modified Beeler-Reuter formulation. The description of the quasiperiodic regimes initiated in a previous paper is completed and their eq...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1289458

    authors: Vinet A

    更新日期:2000-07-01 00:00:00

  • Biomechanical Response Targets of Adult Human Ribs in Frontal Impacts.

    abstract::Thorax injuries mainly due to rib fractures have been associated with high rates of morbidity and mortality in motor vehicle crashes. Thoracic biomechanics has been studied extensively, but there are no robust biomechanical response targets for ribs that consider age, sex, body size, and vulnerability factors. The obj...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02613-x

    authors: Kang YS,Kwon HJ,Stammen J,Moorhouse K,Agnew AM

    更新日期:2021-02-01 00:00:00

  • Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic pressures.

    abstract::Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a microphone implanted in the cuff and pressure changes in the cuff, which can be recorded during such measurements. We...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9853-4

    authors: Jazbinsek V,Luznik J,Mieke S,Trontelj Z

    更新日期:2010-03-01 00:00:00

  • How crouch gait can dynamically induce stiff-knee gait.

    abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9952-2

    authors: van der Krogt MM,Bregman DJ,Wisse M,Doorenbosch CA,Harlaar J,Collins SH

    更新日期:2010-04-01 00:00:00

  • Organ Dynamics and Fluid Dynamics of the HH25 Chick Embryonic Cardiac Ventricle as Revealed by a Novel 4D High-Frequency Ultrasound Imaging Technique and Computational Flow Simulations.

    abstract::Past literature has provided evidence that a normal mechanical force environment of blood flow may guide normal development while an abnormal environment can lead to congenital malformations, thus warranting further studies on embryonic cardiovascular flow dynamics. In the current study, we developed a non-invasive 4D...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1882-9

    authors: Ho S,Tan GXY,Foo TJ,Phan-Thien N,Yap CH

    更新日期:2017-10-01 00:00:00

  • Development of an endothelial-smooth muscle cell coculture model using phenotype-controlled smooth muscle cells.

    abstract::A coculture of endothelial cells (ECs) and smooth muscle cells (SMCs), which mimics cellular interactions appearing in vivo, has been performed in studies on the relationship between atherogenesis and fluid shear stress conditions. Although healthy arteries in vivo consist of contractile phenotype SMCs, cultured cells...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0372-8

    authors: Sakamoto N,Kiuchi T,Sato M

    更新日期:2011-11-01 00:00:00

  • Potential of the genetic algorithm neural network in the assessment of gait patterns in ankle arthrodesis.

    abstract::The aim of this study was to develop an empirical model of parameter-based gait data, based on an artificial neural network and a genetic algorithm, for the assessment of patients after ankle arthrodesis. Ground reaction force vectors were measured by force platforms during level walking. Nine force parameters express...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1342053

    authors: Wu WL,Su FC,Cheng YM,Chou YL

    更新日期:2001-01-01 00:00:00

  • An ex vivo study of the biological properties of porcine aortic valves in response to circumferential cyclic stretch.

    abstract::Normal physiological mechanical forces cause constant tissue renewal in aortic valve leaflets (AVL) while altered mechanical forces incite changes in their structural and biological properties. The current study aims at characterizing the remodeling properties of AVL subjected to cyclic circumferential stretch in a st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9167-8

    authors: Balachandran K,Konduri S,Sucosky P,Jo H,Yoganathan AP

    更新日期:2006-11-01 00:00:00

  • Large-scale 3-D geometric reconstruction of the porcine coronary arterial vasculature based on detailed anatomical data.

    abstract::The temporal and spatial distribution of coronary blood flow, pressure, and volume are determined by the branching pattern and three-dimensional (3-D) geometry of the coronary vasculature, and by the mechanics of heart wall and vascular tone. Consequently, a realistic simulation of coronary blood flow requires, as a f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7544-3

    authors: Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2005-11-01 00:00:00

  • LDL decreases the membrane compliance and cell adhesion of endothelial cells under fluid shear stress.

    abstract::Atherosclerosis is an inflammatory disease of large and medium sized arteriole walls that is precipitated by elevated levels of low-density lipoprotein (LDL) cholesterol in the blood. However, the mechanisms that lead to the initiation of atherosclerosis are not fully understood. In this study, endothelial cells (ECs)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0677-2

    authors: Wei D,Chen Y,Tang C,Huang H,Liu L,Wang Z,Li R,Wang G

    更新日期:2013-03-01 00:00:00

  • Cellularized microcarriers as adhesive building blocks for fabrication of tubular tissue constructs.

    abstract::To meet demands of vascular reconstruction, there is a need for prosthetic alternatives to natural blood vessels. Here we explored a new conduit fabrication approach. Macroporous, gelatin microcarriers laden with human umbilical vein endothelial cells and aortic smooth muscle cells were dispensed into tubular agarose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0883-6

    authors: Twal WO,Klatt SC,Harikrishnan K,Gerges E,Cooley MA,Trusk TC,Zhou B,Gabr MG,Shazly T,Lessner SM,Markwald RR,Argraves WS

    更新日期:2014-07-01 00:00:00

  • Carbachol-induced volume adaptation in mouse bladder and length adaptation via rhythmic contraction in rabbit detrusor.

    abstract::The length-tension (L-T) relationships in rabbit detrusor smooth muscle (DSM) are similar to those in vascular and airway smooth muscles and exhibit short-term length adaptation characterized by L-T curves that shift along the length axis as a function of activation and strain history. In contrast to skeletal muscle, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0590-8

    authors: Speich JE,Wilson CW,Almasri AM,Southern JB,Klausner AP,Ratz PH

    更新日期:2012-10-01 00:00:00

  • Increases of corporal temperature as a risk factor of atherosclerotic plaque instability.

    abstract:BACKGROUND:This work explores for the first time the effects of temperature increments on the development of high shear stresses between plaque and arterial wall due to their different dilatational properties. Data from the literature report febrile reactions prior to myocardial infarction in patients with normal coron...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9397-4

    authors: Guinea GV,Atienza JM,Fantidis P,Rojo FJ,Ortega A,Torres M,Gonzalez P,Elices ML,Hayashi K,Elices M

    更新日期:2008-01-01 00:00:00

  • Fractal character of pulmonary microvascular permeability.

    abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368425

    authors: McNamee JE

    更新日期:1990-01-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Impedances of thin and layered systems: cells with even or odd numbers of interfaces.

    abstract::Impedance data, e.g., system responses, from perturbing small amplitude applied sinusoid signals of near DC to high kilohertz frequencies, give chemical information. Analysis of frequency-dependent imaginary and real impedance proceeds from equivalent analog circuit elements to chemical and physical significance deter...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368537

    authors: Buck RP

    更新日期:1992-01-01 00:00:00

  • Study on tumor microvasculature damage induced by alternate cooling and heating.

    abstract::Tumor vasculature damage induced by various thermal treatments has been studied in vivo via laser confocal microscopy. Murine mammary carcinoma 4T1 was implanted in the nude mice dorsal skin fold window chamber. The implanted tumor was treated by alternate cooling and heating. Results showed that the treatment was muc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9511-2

    authors: Shen Y,Liu P,Zhang A,Xu LX

    更新日期:2008-08-01 00:00:00

  • Body-worn sensor design: what do patients and clinicians want?

    abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0339-9

    authors: Bergmann JH,McGregor AH

    更新日期:2011-09-01 00:00:00

  • Evaluation of human endothelial cells post stent deployment in a cardiovascular simulator in vitro.

    abstract::Percutaneous stent implantation has revolutionized the clinical treatment of occluded arteries. Nevertheless, there is still a large unmet need to prevent re-occlusion after implantation. Consequently, a niche exists for a cost-effective pre-clinical method of evaluating novel interventional devices in human models. T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9701-6

    authors: Punchard MA,O'Cearbhaill ED,Mackle JN,McHugh PE,Smith TJ,Stenson-Cox C,Barron V

    更新日期:2009-07-01 00:00:00

  • Fluid dynamic assessment of three polymeric heart valves using particle image velocimetry.

    abstract::Polymeric heart valves have the potential to reduce thrombogenic complications associated with current mechanical valves and overcome fatigue-related problems experienced by bioprosthetic valves. In this paper we characterize the in vitro velocity and Reynolds Shear Stress (RSS) fields inside and downstream of three d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9117-5

    authors: Leo HL,Dasi LP,Carberry J,Simon HA,Yoganathan AP

    更新日期:2006-06-01 00:00:00