Superparamagnetic iron oxide is suitable to label tendon stem cells and track them in vivo with MR imaging.

Abstract:

:Tendon stem cells (TSCs) may be used to effectively repair or regenerate injured tendons. However, the fates of TSCs once implanted in vivo remain unclear. This study was aimed to determine the feasibility of labeling TSCs with super-paramagnetic iron oxide (SPIO) nano-particles to track TSCs in vivo using MRI. Rabbit TSCs were labeled by incubation with 50 μg/mL SPIO. Labeling efficiency, cell viability, and proliferation were then measured, and the stemness of TSCs was tested by quantitative real time RT-PCR (qRT-PCR) and immunocytochemistry. We found that the labeling efficiency of TSCs reached as high as 98%, and that labeling at 50 μg/mL SPIO concentrations did not alter cell viability and cell proliferation compared to non-labeled control cells. Moreover, the expression levels of stem cell markers (Nucleostemin, Nanog, and Oct-4) did not change in SPIO-labeled TSCs compared to non-labeled cells. Both labeled and non-labeled cells also exhibited similar differentiation potential. Finally, labeled TSCs could be detected by MRI both in vitro and in vivo. Taken together, the findings of this study show that labeling TSCs with SPIO particles is a feasible approach to track TSCs in vivo by MRI, which offers a non-invasive method to monitor repair of injured tendons.

journal_name

Ann Biomed Eng

authors

Yang Y,Zhang J,Qian Y,Dong S,Huang H,Boada FE,Fu FH,Wang JH

doi

10.1007/s10439-013-0802-x

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

2109-19

issue

10

eissn

0090-6964

issn

1573-9686

journal_volume

41

pub_type

杂志文章
  • Regional distribution of aerosol deposition in rat lungs using magnetic resonance imaging.

    abstract::The toxic or therapeutic effect of an inhaled aerosol is highly dependent upon the site and extent of deposition in the lung. A novel MRI-based method was used to quantify the spatial distribution of particles in the rat lung. Rats were exposed to 0.95 μm-diameter iron oxide particles in a controlled manner (N = 6) or...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0745-2

    authors: Oakes JM,Scadeng M,Breen EC,Prisk GK,Darquenne C

    更新日期:2013-05-01 00:00:00

  • Automatized Patient-Specific Methodology for Numerical Determination of Biomechanical Corneal Response.

    abstract::This work presents a novel methodology for building a three-dimensional patient-specific eyeball model suitable for performing a fully automatic finite element (FE) analysis of the corneal biomechanics. The reconstruction algorithm fits and smooths the patient's corneal surfaces obtained in clinic with corneal topogra...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-015-1426-0

    authors: Ariza-Gracia MÁ,Zurita J,Piñero DP,Calvo B,Rodríguez-Matas JF

    更新日期:2016-05-01 00:00:00

  • Optimizing magnetic nanoparticle based thermal therapies within the physical limits of heating.

    abstract::Magnetic nanoparticle (mNP) based thermal therapies have demonstrated relevance in the clinic, but effective application requires an understanding of both its strengths and limitations. This study explores two critical limitations for clinical use: (1) maximizing localized mNP heating, while avoiding bulk heating due ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0633-1

    authors: Etheridge ML,Bischof JC

    更新日期:2013-01-01 00:00:00

  • A numerical implementation to predict residual strains from the homogeneous stress hypothesis with application to abdominal aortic aneurysms.

    abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0749-y

    authors: Polzer S,Bursa J,Gasser TC,Staffa R,Vlachovsky R

    更新日期:2013-07-01 00:00:00

  • Image-Based Simulations Show Important Flow Fluctuations in a Normal Left Ventricle: What Could be the Implications?

    abstract::Intra-cardiac flow has been explored for decades but there is still no consensus on whether or not healthy left ventricles (LV) may harbour turbulent-like flow despite its potential physiological and clinical relevance. The purpose of this study is to elucidate if a healthy LV could harbour flow instabilities, using i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1614-6

    authors: Chnafa C,Mendez S,Nicoud F

    更新日期:2016-11-01 00:00:00

  • Mechanical behavior of vascular smooth muscle in cylindrical segments of arteries in vitro.

    abstract::Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02363919

    authors: Dobrin PB

    更新日期:1984-01-01 00:00:00

  • A Conceivable Mechanism Responsible for the Synergy of High and Low Voltage Irreversible Electroporation Pulses.

    abstract::Irreversible electroporation (IRE), is a new non-thermal tissue ablation technology in which brief high electric field pulses are delivered across the target tissue to induce cell death by irreversible permeabilization of the cell membrane. A deficiency of conventional IRE is that the ablation zone is relatively small...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02258-5

    authors: Lv Y,Yao C,Rubinsky B

    更新日期:2019-07-01 00:00:00

  • Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.

    abstract::There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1781-5

    authors: Inoue Y,Yokota T,Sekitani T,Kaneko A,Woo T,Kobayashi S,Shibuya T,Tanaka M,Kosukegawa H,Saito I,Isoyama T,Abe Y,Yambe T,Someya T,Sekino M

    更新日期:2017-05-01 00:00:00

  • Shear modulus of elasticity of the esophagus.

    abstract::Experimental and diagnostic procedures like distension of a balloon catheter, bougie, and esophagogastroduodenoscopy can induce shear deformation in the esophageal wall. However, the shear modulus of the esophagus is yet unknown. The aim of this study was to determine the esophageal shear modulus and its dependence on...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000039356.24821.6c

    authors: Yang J,Liao D,Zhao J,Gregersen H

    更新日期:2004-09-01 00:00:00

  • Kinematic analysis of the human temporomandibular joint.

    abstract::A kinematic analysis of the temporomandibular joint (TMJ) is developed to determine the range of motion of the mandible during normal opening and during special motions required for arthroscopic surgery. The translation of the mandible is restricted by the constraint of the ligaments. By accounting for the maximum all...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368648

    authors: Kang QS,Updike DP,Salathe EP

    更新日期:1993-11-01 00:00:00

  • Biomechanical Properties and Microstructure of Heart Chambers: A Paired Comparison Study in an Ovine Model.

    abstract::Mechanical properties of the cardiac tissue play an important role in normal heart function. The goal of this study was to determine the passive mechanical properties of all heart chambers through a paired comparison study in an ovine model. Ovine heart was used due its physiological and anatomical similarities to hum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1658-7

    authors: Javani S,Gordon M,Azadani AN

    更新日期:2016-11-01 00:00:00

  • A Non-Invasive Material Characterization Framework for Bioprosthetic Heart Valves.

    abstract::Computational modeling and simulation has become more common in design and development of bioprosthetic heart valves. To have a reliable computational model, considering accurate mechanical properties of biological soft tissue is one of the most important steps. The goal of this study was to present a non-invasive mat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02129-5

    authors: Abbasi M,Barakat MS,Dvir D,Azadani AN

    更新日期:2019-01-01 00:00:00

  • Tissue remodeling of rat pulmonary artery in hypoxic breathing. II. Course of change of mechanical properties.

    abstract::When cells and the matrix of a tissue remodel, the mechanical properties of the tissue do change. The mechanical properties are expressed by constitutive equations. In this article the remodeling of the constitutive equation of the pulmonary artery is studied. The remodeling was induced in a rat breathing a gas whose ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1380417

    authors: Huang W,Delgado-West D,Wu JT,Fung YC

    更新日期:2001-01-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Biomechanical properties of esophagus during systemic treatment with epidermal growth factor in rats.

    abstract::The epidermal growth factor (EGF) is a growth factor with effects on many cell types and tissue. Morphometric and passive biomechanical properties were studied in isolated segments of the esophagus in 22 EGF-treated rats and 12 control rats. The rats were divided into groups with EGF treatment for 2, 4, 7, and 14 days...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1575758

    authors: Zhao J,Yang J,Vinter-Jensen L,Zhuang F,Gregersen H

    更新日期:2003-06-01 00:00:00

  • An improved Morris Water Maze tracking algorithm for psychophysical studies.

    abstract::An algorithm to track a rat swimming in a Morris Water Maze has been developed. The system is automatically configured to any pool and relative suitable light conditions. It tracks the rat's position and head pose 10 times per second. The output data is displayed in a bitmap and also in a text file. The system was tes...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000036650.32345.b6

    authors: Hval ES,Barrett SF,Wilcox M,Bailey TA

    更新日期:2004-08-01 00:00:00

  • Monitoring Bone Tissue Engineered (BTE) Constructs Based on the Shifting Metabolism of Differentiating Stem Cells.

    abstract::Ever-increasing demand for bone grafts necessitates the realization of clinical implementation of bone tissue engineered constructs. The predominant hurdle to implementation remains to be securing FDA approval, based on the lack of viable methods for the rigorous monitoring of said constructs. The study presented here...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1937-y

    authors: Simmons AD,Sikavitsas VI

    更新日期:2018-01-01 00:00:00

  • Evaluating the Impact of Calcification on Plaque Vulnerability from the Aspect of Mechanical Interaction Between Blood Flow and Artery Based on MRI.

    abstract::Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid-structure interaction (FSI) models...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02655-1

    authors: Benitez J,Fontanarosa D,Wang J,Paritala PK,McGahan T,Lloyd T,Li Z

    更新日期:2020-10-20 00:00:00

  • Hydraulic Conductivity of Smooth Muscle Cell-Initiated Arterial Cocultures.

    abstract::The purpose of the study was to examine the effects of arterial coculture conditions on the transport properties of several in vitro endothelial cell (EC)-smooth muscle cell (SMC)-porous filter constructs in which SMC were grown to confluence first and then EC were inoculated. This order of culturing simulates the env...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1421-5

    authors: Mathura RA,Russell-Puleri S,Cancel LM,Tarbell JM

    更新日期:2016-05-01 00:00:00

  • Breathing resistance and ultrafine particle deposition in nasal-laryngeal airways of a newborn, an infant, a child, and an adult.

    abstract::As a human grows from birth to adulthood, both airway anatomy and breathing conditions vary, altering the deposition rate and pattern of inhaled aerosols. However, deposition studies have typically focused on adult subjects, results of which may not be readily extrapolated to children. This study numerically evaluated...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0603-7

    authors: Xi J,Berlinski A,Zhou Y,Greenberg B,Ou X

    更新日期:2012-12-01 00:00:00

  • A Dual-Mode Bioreactor System for Tissue Engineered Vascular Models.

    abstract::In the past decades, vascular tissue engineering has made great strides towards bringing engineered vascular tissues to the clinics and, in parallel, obtaining in-lab tools for basic research. Herein, we propose the design of a novel dual-mode bioreactor, useful for the fabrication (construct mode) and in vitro stimul...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1813-9

    authors: Bono N,Meghezi S,Soncini M,Piola M,Mantovani D,Fiore GB

    更新日期:2017-06-01 00:00:00

  • Comparison of Laboratory and On-Field Performance of American Football Helmets.

    abstract::The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02627-5

    authors: Bailey AM,McMurry TL,Cormier JM,Funk JR,Crandall JR,Mack CD,Myers BS,Arbogast KB

    更新日期:2020-11-01 00:00:00

  • Selective stimulation of latissimus dorsi muscle for cardiac assist.

    abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.164

    authors: Thompson DR,Michele JJ,Cheever EA,George DT

    更新日期:1999-01-01 00:00:00

  • Adaptive neural network that subserves optimal homeostatic control of breathing.

    abstract::An adaptive neural network model that exhibits the optimality and homeostasis characteristics of the respiratory control system is described. Based upon the Hopfield network structure and a postulated Hebb-like respiratory synapse with correlational short-term potentiation, the model is capable of mimicking the normal...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584332

    authors: Poon CS

    更新日期:1993-09-01 00:00:00

  • Reduced parameter formulation for incorporating fiber level viscoelasticity into tissue level biomechanical models.

    abstract::Collagen is known to be a viscoelastic material and therefore is an important source of time dependent behavior in soft tissue. Though there are material models for soft tissue that rely on properties and structure of constituent collagen fibers, such models generally utilize only the elastic properties of collagen, a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9124-6

    authors: Bischoff JE

    更新日期:2006-07-01 00:00:00

  • Carbachol-induced volume adaptation in mouse bladder and length adaptation via rhythmic contraction in rabbit detrusor.

    abstract::The length-tension (L-T) relationships in rabbit detrusor smooth muscle (DSM) are similar to those in vascular and airway smooth muscles and exhibit short-term length adaptation characterized by L-T curves that shift along the length axis as a function of activation and strain history. In contrast to skeletal muscle, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0590-8

    authors: Speich JE,Wilson CW,Almasri AM,Southern JB,Klausner AP,Ratz PH

    更新日期:2012-10-01 00:00:00

  • Self-contained in-the-ear device to deliver altered auditory feedback: applications for stuttering.

    abstract::The design and operating characteristics of the first self-contained in-the-ear device to deliver altered auditory feedback is described for applications with those who stutter. The device incorporates a microdigital signal processor core that reproduces the high fidelity of unaided listening and auditory self-monitor...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1541014

    authors: Stuart A,Xia S,Jiang Y,Jiang T,Kalinowski J,Rastatter MP

    更新日期:2003-02-01 00:00:00

  • Perspectives on Bioengineering Clinical Immersion: History, Innovation, and Impact.

    abstract::Opportunities to provide clinical immersion experiences to bioengineering undergraduate students have expanded over the last several years. These programs allow students to observe the clinical environment in order to better understand workflow processes, the context in which medical equipment is used, and identify un...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02508-x

    authors: Kotche M,Felder AE,Wilkens K,Stirling S

    更新日期:2020-09-01 00:00:00

  • Off-line and on-line stress detection through processing of the pupil diameter signal.

    abstract::The pupil diameter (PD), controlled by the autonomic nervous system, seems to provide a strong indication of affective arousal, as found by previous research, but it has not been investigated fully yet. In this study, new approaches based on monitoring and processing the PD signal for off-line and on-line "relaxation"...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0880-9

    authors: Ren P,Barreto A,Huang J,Gao Y,Ortega FR,Adjouadi M

    更新日期:2014-01-01 00:00:00

  • Stenosis Hemodynamics Disrupt the Endothelial Cell Glycocalyx by MMP Activity Creating a Proinflammatory Environment.

    abstract::Hemodynamic forces are known to be able to induce an inflammatory phenotype in endothelial cells (ECs). The EC glycocalyx (GCX) is a dynamic structure which is regulated in response to different stimuli and hypothesized as an important contributor to the mechanotransduction of wall shear stresses (WSS). In this work, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1846-0

    authors: Cooper S,McDonald K,Burkat D,Leask RL

    更新日期:2017-09-01 00:00:00