Mechanical behavior of vascular smooth muscle in cylindrical segments of arteries in vitro.

Abstract:

:Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies show that the vascular muscle in cylindrical arteries develops a maximum active stress of 1.1 X 10(5) N/m2 for the whole wall, or 2.2-3.7 X 10(5) N/m2 for the volume of the wall occupied by vascular muscle. These values are similar to those reported for strip studies of vascular muscle and various preparations of skeletal muscle, but are two to five times that reported for cardiac papillary muscle preparations. In cylindrical preparations of arteries, maximum isometric active stress occurs at 150 mm Hg, whereas that in veins occurs at less than 15 mm Hg. Quick release experiments of cylindrical segments of vessels avoid the compliance of inactive tissue trapped beneath ligatures in strip studies. Quick release experiments in cylindrical segments of dog carotid artery reveal that at maximum isometric stress, the series elastic component (SEC) is extended 8-11%. Experiments employing temperature variations and degradative enzymes show that the SEC is located largely in elastin, with a lesser portion located in the contractile apparatus. At short- and long-muscle lengths, the active muscle develops decreased active stress and that developed at long lengths persists at all muscle lengths, even after shortening. This has been termed "attenuation" and appears to contribute to the static length-stress and pressure-diameter hysteresis exhibited by vessels. Excitation of vascular muscle in vessel segments held at constant pressure discloses that isobaric contraction decreases artery diameter a maximum of approximately 25%. This occurs at a dimension corresponding to approximately 100 mm Hg in the relaxed vessel. Isometrically and isobarically contracted vessels tend to fall along the same pressure-diameter coordinates, indicating equivalence of both modes of contraction. Distention of contracted vessels indicates that active vascular muscle markedly resists distention up to 150-250 mm Hg; at higher pressures the contracted vessel exhibits decreased stiffness as the contracted muscle yields. The vascular muscle, therefore, has a biphasic effect on circumferential elastic modulus relative to that of the relaxed vessel.(ABSTRACT TRUNCATED AT 400 WORDS)

journal_name

Ann Biomed Eng

authors

Dobrin PB

doi

10.1007/BF02363919

subject

Has Abstract

pub_date

1984-01-01 00:00:00

pages

497-510

issue

5

eissn

0090-6964

issn

1573-9686

journal_volume

12

pub_type

杂志文章
  • Evaluation of effectiveness of a facet wiring technique: an in vitro biomechanical investigation.

    abstract::The effects of facet wiring procedure commonly used for stabilizing cervical spines after laminectomy or bilateral facet dislocation on the motion behavior of whole cervical spines are investigated using a Selspot II system. A fresh human ligamentous intact specimen was potted at T1/T2 vertebra and clinically relevant...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368022

    authors: Goel VK,Clark CR,Harris KG,Kim YE,Schulte KR

    更新日期:1989-01-01 00:00:00

  • Biomechanical characterization of internal layer subfailure in blunt arterial injury.

    abstract::Blunt carotid artery injuries occur in 0.3% of blunt injured patients and may lead to devastating neurological consequences. However, arterial mechanics leading to internal layer subfailure have not been quantified. Twenty-two human carotid artery segments and 18 porcine thoracic aorta segments were opened to expose t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9229-y

    authors: Stemper BD,Yoganandan N,Sinson GP,Gennarelli TA,Stineman MR,Pintar FA

    更新日期:2007-02-01 00:00:00

  • Population-Based Bone Strain During Physical Activity: A Novel Method Demonstrated for the Human Femur.

    abstract::Statistical methods are increasingly used in biomechanics for studying bone geometry, bone density distribution and function in the population. However, relating population-based bone variation to strain during activity is computationally challenging. Here, we describe a new method for calculating strain in a populati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02483-3

    authors: Ziaeipoor H,Taylor M,Martelli S

    更新日期:2020-06-01 00:00:00

  • Fluid dynamics of gas exchange in high-frequency oscillatory ventilation: in vitro investigations in idealized and anatomically realistic airway bifurcation models.

    abstract::The objective of this work is to develop understanding of the local fluid dynamic mechanisms that underpin gas exchange in high-frequency oscillatory ventilation (HFOV). The flow field during HFOV was investigated experimentally using particle image velocimetry in idealized and realistic models of a single bifurcation...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9557-1

    authors: Heraty KB,Laffey JG,Quinlan NJ

    更新日期:2008-11-01 00:00:00

  • Biomechanical Properties and Microstructure of Heart Chambers: A Paired Comparison Study in an Ovine Model.

    abstract::Mechanical properties of the cardiac tissue play an important role in normal heart function. The goal of this study was to determine the passive mechanical properties of all heart chambers through a paired comparison study in an ovine model. Ovine heart was used due its physiological and anatomical similarities to hum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1658-7

    authors: Javani S,Gordon M,Azadani AN

    更新日期:2016-11-01 00:00:00

  • Image-based computational fluid dynamics modeling in realistic arterial geometries.

    abstract::Local hemodynamics are an important factor in atherosclerosis, from the development of early lesions, to the assessment of stroke risk, to determining the ultimate fate of a mature plaque. Until recently, our understanding of arterial fluid dynamics and their relationship to atherosclerosis was limited by the use of i...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1467679

    authors: Steinman DA

    更新日期:2002-04-01 00:00:00

  • Estimation of Reynolds shear stresses during pulsatile flow in the region of aortic valves.

    abstract::Some investigators have attempted to estimate the Reynolds shear stress on the basis of a single component of velocity. The purpose of this investigation is to determine the validity of such estimates in a complex flow field, such as occurs in the cardiovascular system in the region of the aortic valve. Turbulent velo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02371247

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1985-01-01 00:00:00

  • Fluid dynamic assessment of three polymeric heart valves using particle image velocimetry.

    abstract::Polymeric heart valves have the potential to reduce thrombogenic complications associated with current mechanical valves and overcome fatigue-related problems experienced by bioprosthetic valves. In this paper we characterize the in vitro velocity and Reynolds Shear Stress (RSS) fields inside and downstream of three d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9117-5

    authors: Leo HL,Dasi LP,Carberry J,Simon HA,Yoganathan AP

    更新日期:2006-06-01 00:00:00

  • Large-scale 3-D geometric reconstruction of the porcine coronary arterial vasculature based on detailed anatomical data.

    abstract::The temporal and spatial distribution of coronary blood flow, pressure, and volume are determined by the branching pattern and three-dimensional (3-D) geometry of the coronary vasculature, and by the mechanics of heart wall and vascular tone. Consequently, a realistic simulation of coronary blood flow requires, as a f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-7544-3

    authors: Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2005-11-01 00:00:00

  • An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve.

    abstract::The most widely implanted prosthetic valve is the mechanical bileaflet. Recent clinical experiences suggest that some designs are more prone to thromboembolic episodes than others. This study evaluated the hinge flow and near-field forward flow of the new St. Jude Medical Regent bileaflet mechanical heart valve. Laser...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.297

    authors: Ellis JT,Travis BR,Yoganathan AP

    更新日期:2000-05-01 00:00:00

  • Mechanical Performance of Two Left Atrial Appendage Occlusion Systems: In Vitro Comparison of Tug Force, Radial Force, Sealing and Deformation.

    abstract::The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech®, of three different sizes underwent testing in novel dedicated in vitro setups. Radial force wa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2057-z

    authors: Menne MF,Schrickel JW,Nickenig G,Al-Kassou B,Nelles D,Schmitz-Rode T,Steinseifer U,Sedaghat A

    更新日期:2018-09-01 00:00:00

  • Validity of Skin, Oral and Tympanic Temperatures During Exercise in the Heat: Effects of Wind and Sweat.

    abstract::This experiment investigates the validity of six thermometers with different measuring sensors, operation and site of application, to estimate core temperature (Tc) in comparison to an ingestible thermometric sensor based on quartz crystal technology. Measurements were obtained before, during and after exercise in the...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-018-02115-x

    authors: Morán-Navarro R,Courel-Ibáñez J,Martínez-Cava A,Conesa-Ros E,Sánchez-Pay A,Mora-Rodriguez R,Pallarés JG

    更新日期:2019-01-01 00:00:00

  • Progression of abdominal aortic aneurysm towards rupture: refining clinical risk assessment using a fully coupled fluid-structure interaction method.

    abstract::Rupture of abdominal aortic aneurysm (AAA) is associated with high mortality rates. Risk of rupture is multi-factorial involving AAA geometric configuration, vessel tortuosity, and the presence of intraluminal pathology. Fluid structure interaction (FSI) simulations were conducted in patient based computed tomography ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1224-0

    authors: Xenos M,Labropoulos N,Rambhia S,Alemu Y,Einav S,Tassiopoulos A,Sakalihasan N,Bluestein D

    更新日期:2015-01-01 00:00:00

  • Mechanical analysis of atherosclerotic plaques based on optical coherence tomography.

    abstract::Finite element analysis is a powerful tool for investigating the biomechanics of atherosclerosis and has thereby provided an improved understanding of acute myocardial infarction. Structural analysis of arterial walls is traditionally performed using geometry contours derived from histology. In this paper we demonstra...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000049034.75368.4a

    authors: Chau AH,Chan RC,Shishkov M,MacNeill B,Iftimia N,Tearney GJ,Kamm RD,Bouma BE,Kaazempur-Mofrad MR

    更新日期:2004-11-01 00:00:00

  • Use of pseudorandom noise in studies of auditory evoked potentials.

    abstract::The extent to which sensorineural systems such as the auditory system are nonlinear depends on the type of stimulus that is used, and the part of the system from which recordings are made. An estimate of the first-order Wiener kernel of the evoked response from the inferior colliculus to amplitude-modulated tones and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367379

    authors: Møller AR,Angelo RM

    更新日期:1988-01-01 00:00:00

  • Effects of Hollow Fiber Membrane Oscillation on an Artificial Lung.

    abstract::Gas transfer through hollow fiber membranes (HFMs) can be increased via fiber oscillation. Prior work, however, does not directly translate to present-day, full-scale artificial lungs. This in vitro study characterized the effects of HFM oscillations on oxygenation and hemolysis for a pediatric-sized HFM bundle. Effec...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-1995-9

    authors: Orizondo RA,Gino G,Sultzbach G,Madhani SP,Frankowski BJ,Federspiel WJ

    更新日期:2018-05-01 00:00:00

  • Effects of External and Internal Hyperthermia on LDL Transport and Accumulation Within an Arterial Wall in the Presence of a Stenosis.

    abstract::Effects of hyperthermia on transport of low-density lipoprotein (LDL) through a stenosed arterial wall are analyzed comprehensively in the present work. The realistic and pertinent aspects of an arterial wall is represented by a multi-layer model, with a proper representation of the thickened intima region due to the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1196-0

    authors: Iasiello M,Vafai K,Andreozzi A,Bianco N,Tavakkoli F

    更新日期:2015-07-01 00:00:00

  • Permeability analysis of neuroactive drugs through a dynamic microfluidic in vitro blood-brain barrier model.

    abstract::This paper presents the permeability analysis of neuroactive drugs and correlation with in vivo brain/plasma ratios in a dynamic microfluidic blood-brain barrier (BBB) model. Permeability of seven neuroactive drugs (Ethosuximide, Gabapentin, Sertraline, Sunitinib, Traxoprodil, Varenicline, PF-304014) and trans-endothe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1086-5

    authors: Booth R,Kim H

    更新日期:2014-12-01 00:00:00

  • Finite element modeling of coupled diffusion with partitioning in transdermal drug delivery.

    abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5788-6

    authors: Rim JE,Pinsky PM,van Osdol WW

    更新日期:2005-10-01 00:00:00

  • A Fluorescence Sensing Method with Reduced DNA Typing and Low-Cost Instrumentation for Detection of Sample Tampering Cases in Urinalysis.

    abstract::This work presents a method to unequivocally detect urine sample tampering in cases where integrity of the sample needs to be verified prior to urinalysis. The technique involves the detection of distinct patterns of a triplex short tandem repeats system in DNA extracted from human urine. The analysis is realized with...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02386-y

    authors: Pires NMM,Dong T,Yang Z,Santos SMB

    更新日期:2020-02-01 00:00:00

  • A review of the role of the partial pressure of carbon dioxide in mechanically loaded tissues: the canary in the cage singing in tune with the pressure ulcer mantra.

    abstract::Pressure ulcers (PUs) can occur in any situations where people are subjected to non-uniform distribution of pressure over a prolonged period. They can have devastating effects on the patients' well-being and in extreme conditions can prove fatal. In addition to traditional wisdom implicating mechanically induced ischa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1233-z

    authors: Mirtaheri P,Gjøvaag T,Worsley PR,Bader DL

    更新日期:2015-02-01 00:00:00

  • Adaptive fractal analysis reveals limits to fractal scaling in center of pressure trajectories.

    abstract::Fractal time series analysis methods are commonly used for analyzing center of pressure (COP) signals with the goal of revealing the underlying neuromuscular processes for upright stance control. The use of fractal methods is often coupled with the assumption that the COP is an instance of fractional Gaussian noise (f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0646-9

    authors: Kuznetsov N,Bonnette S,Gao J,Riley MA

    更新日期:2013-08-01 00:00:00

  • Measurement of signal and noise characteristics in ongoing auditory brainstem response averaging.

    abstract::Although diagnostic testing with auditory evoked potentials (EPs) has become routine, quantitative measurements of signal and noise are still lacking. In this study, current signal, power, noise power, and signal-to-noise ratio (SNR) estimation formulas are reviewed and applied to auditory brainstem response averaging...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684183

    authors: Ozdamar O,Delgado RE

    更新日期:1996-11-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Nonequilibrium facilitated transport of carbon dioxide in bicarbonate and bovine albumin solutions.

    abstract::The nonlinear diffusion-reaction equations describing the nonequilibrium transport of CO2 through flat layers of complex but homogeneous aqueous media were solved by an approximate analytical method called the "Combined Damköhler Number" (CDN) technique. Unlike other approximate analytical solutions, the CDN technique...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02484468

    authors: Hoofd LJ,Tong RR,Stroeve P

    更新日期:1986-01-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Hemodynamic energy dissipation in the cardiovascular system: generalized theoretical analysis on disease states.

    abstract:BACKGROUND:We present a fundamental theoretical framework for analysis of energy dissipation in any component of the circulatory system and formulate the full energy budget for both venous and arterial circulations. New indices allowing disease-specific subject-to-subject comparisons and disease-to-disease hemodynamic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9650-0

    authors: Dasi LP,Pekkan K,de Zelicourt D,Sundareswaran KS,Krishnankutty R,Delnido PJ,Yoganathan AP

    更新日期:2009-04-01 00:00:00

  • Motile Dendritic Cells Sense and Respond to Substrate Geometry.

    abstract::Dendritic cell (DC) migration is required for efficient presentation of antigen to T cells and the initiation of an adaptive immune response. In spite of its importance, many aspects of DC migration have not been characterized. DCs encounter a variety of environments with different stiffness and geometry, but the effe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2041-7

    authors: Bendell AC,Anderson N,Blumenthal D,Williamson EK,Chen CS,Burkhardt JK,Hammer DA

    更新日期:2018-09-01 00:00:00

  • Dynamics of revolution time variability in cycling pattern: voluntary intent can alter the long-range autocorrelations.

    abstract::Long-range dependency has been found in most rhythmic motor signals. The origin of this property is unknown and largely debated. There is a controversy on the influence of voluntary control induced by requiring a pre-determined pace such as asking subjects to step to a metronome. We studied the cycle duration variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-013-0834-2

    authors: Warlop TB,Bollens B,Crevecoeur F,Detrembleur C,Lejeune TM

    更新日期:2013-08-01 00:00:00

  • Reproducibility of image-based computational fluid dynamics models of the human carotid bifurcation.

    abstract::Recent studies have demonstrated the ability of magnetic resonance imaging (MRI) to provide anatomically realistic boundary conditions for computational fluid dynamics (CFD) simulations of arterial hemodynamics. To date, however, little is known about the overall reproducibility of such image-based CFD techniques. Tow...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1540102

    authors: Thomas JB,Milner JS,Rutt BK,Steinman DA

    更新日期:2003-02-01 00:00:00