Abstract:
:Gas transfer through hollow fiber membranes (HFMs) can be increased via fiber oscillation. Prior work, however, does not directly translate to present-day, full-scale artificial lungs. This in vitro study characterized the effects of HFM oscillations on oxygenation and hemolysis for a pediatric-sized HFM bundle. Effects of oscillation stroke length (2-10 mm) and frequency (1-25 Hz) on oxygen transfer were measured according to established standards. The normalized index of hemolysis was measured for select conditions. All measurements were performed at a 2.5 L min-1 blood flow rate. A lumped parameter model was used to predict oscillation-induced blood flow and elucidate the effects of system parameters on oxygenation. Oxygen transfer increased during oscillations, reaching a maximum oxygenation efficiency of 510 mL min-1 m-2 (97% enhancement relative to no oscillation). Enhancement magnitudes matched well with model-predicted trends and were dependent on stroke length, frequency, and physical system parameters. A 40% oxygenation enhancement was achieved without significant hemolysis increase. At a constant enhancement magnitude, a larger oscillation frequency resulted in increased hemolysis. In conclusion, HFM oscillation is a feasible approach to increasing artificial lung gas transfer efficiency. The optimal design for maximizing efficiency at small fiber displacements should minimize bundle resistance and housing compliance.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Orizondo RA,Gino G,Sultzbach G,Madhani SP,Frankowski BJ,Federspiel WJdoi
10.1007/s10439-018-1995-9subject
Has Abstractpub_date
2018-05-01 00:00:00pages
762-771issue
5eissn
0090-6964issn
1573-9686pii
10.1007/s10439-018-1995-9journal_volume
46pub_type
杂志文章abstract::For highly diffusive solutes the kinetics of blood-tissue exchange is only poorly represented by a model consisting of sets of independent parallel capillary-tissue units. We constructed a more realistic multicapillary network model conforming statistically to morphometric data. Flows through the tortuous paths in the...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.273
更新日期:2000-03-01 00:00:00
abstract::We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstru...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1463-8
更新日期:2016-05-01 00:00:00
abstract::The ability to predict endothelial cell migration rates may aid in the design of biomaterials that endothelialize following implantation. However, the complexity of the signaling response to migration-promoting stimuli such as sphingosine 1-phosphate (S1P) makes such predictions quite challenging. A number of signalin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0014-6
更新日期:2010-08-01 00:00:00
abstract::User preferences need to be taken into account in order to be able to design devices that will gain acceptance both in a clinical and home setting. Sensor systems become redundant if patients or clinicians do not want to work with them. The aim of this systematic review was to determine both patients' and clinicians' ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-011-0339-9
更新日期:2011-09-01 00:00:00
abstract::Presented is a discussion of steps towards the creation of a database of the microcirculation encompassing anatomical and functional experimental data, and conceptual and computational models. The discussion includes issues of database utility, organization, data deposition, and linkage to other databases. The databas...
journal_title:Annals of biomedical engineering
pub_type:
doi:10.1114/1.112
更新日期:1998-11-01 00:00:00
abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1340-5
更新日期:2015-06-01 00:00:00
abstract::While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registratio...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02113-z
更新日期:2018-12-01 00:00:00
abstract::As a human grows from birth to adulthood, both airway anatomy and breathing conditions vary, altering the deposition rate and pattern of inhaled aerosols. However, deposition studies have typically focused on adult subjects, results of which may not be readily extrapolated to children. This study numerically evaluated...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0603-7
更新日期:2012-12-01 00:00:00
abstract::A multifunctional FePt nanoparticle was developed that targets tumor microvasculature via "radiation-guided" peptides, and is detected by both near-infrared (NIR) fluorescence imaging and analytical mass spectrometry methods. Tumor specific binding was first measured by biotinylated peptide linked to fluorophore-conju...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0219-8
更新日期:2011-03-01 00:00:00
abstract::The traditional auscultatory technique and current methodologies for measuring human blood pressure are limited when used in situations where extreme vibration or acoustic noise is present. In this study, human subjects were used to establish the effectiveness of a novel adaptive blood pressure monitoring (ABPM) syste...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1114/1.1481051
更新日期:2002-05-01 00:00:00
abstract::Arteries are composed of multiple constituents that endow the wall with proper structure and function. Many vascular diseases are associated with prominent mechanical and biological alterations in the wall constituents. In this study, planar biaxial tensile test data of elastase-treated porcine aortic tissue (Chow et ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0733-y
更新日期:2013-07-01 00:00:00
abstract::Much effort is expended in developing biomimetic scaffolds that provide the micro-architecture of native tissue with appropriate cellular niches. Such scaffolds are often seeded with progenitor cells to generate engineered replacements for diseased or damaged tissues. An alternative approach relies on biology, rather ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-014-1174-6
更新日期:2015-03-01 00:00:00
abstract::The most widely implanted prosthetic valve is the mechanical bileaflet. Recent clinical experiences suggest that some designs are more prone to thromboembolic episodes than others. This study evaluated the hinge flow and near-field forward flow of the new St. Jude Medical Regent bileaflet mechanical heart valve. Laser...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.297
更新日期:2000-05-01 00:00:00
abstract::We propose a multiphysical mathematical model by fully coupling lipid deposition, monocytes/macrophages recruitment and angiogenesis to investigate the pathophysiological responses of an atherosclerotic plaque to the dynamic changes in the microenvironment. The time evolutions of cellular (endothelial cells, macrophag...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02173-1
更新日期:2019-02-01 00:00:00
abstract::Knowledge of strain-rate sensitivity of soft tissue viscoelastic and nonlinear elastic properties is important for accurate predictions of biomechanical behavior and for quantitative assessment of the effects of disease or surgical/pharmaceutical intervention. Soft tissues are known to exhibit mild rate sensitivity, b...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1023/b:abme.0000012742.01261.b0
更新日期:2004-02-01 00:00:00
abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1533074
更新日期:2003-01-01 00:00:00
abstract::We seek to construct physical and mathematical models of life. Such models allow us to test our understanding of how living systems function and how they respond to human imposed stimuli. One system is a genomically and chemically complete model of a minimal cell. This cell is a hypothetical bacterium with the fewest ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-012-0567-7
更新日期:2012-07-01 00:00:00
abstract::Proteoglycan 4 (PRG4) is a mucin-like glycoprotein present in synovial fluid and at the surface of articular cartilage. The objectives of this study were to (1) assess the articular cartilage surface adsorption and in vitro cartilage boundary lubricating ability of full-length recombinant human PRG4 (rhPRG4), and (2) ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1390-8
更新日期:2016-04-01 00:00:00
abstract::A recent analytical solution of the three-dimensional Stokes flow through a bumpy tube predicts that for a given bump area, there exists an optimal circumferential wavenumber which minimizes flow resistance. This study uses measurements of microvessel endothelial cell morphology to test whether this prediction holds i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9467-2
更新日期:2008-04-01 00:00:00
abstract::Recent advances in angioplasty have involved the application of polymer coatings to stent surfaces for purposes of drug delivery. Given the high levels of deformation developed in the plastic hinge of a stent during deployment, the achievement of an intact bond between the coating and the stent presents a significant ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9972-y
更新日期:2010-07-01 00:00:00
abstract::Clinicians generally assume that Medical Compression Stockings (MCS) work by reducing vein luminal diameter and, in this way, help to prevent blood pooling. Conflicting results have been reported however in the case of lower leg deep veins which call into question this hypothesis. The purpose of this contribution is t...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1121-6
更新日期:2015-02-01 00:00:00
abstract::Skeletal muscles can be injured by their own contractions. Such contraction-induced injury, often accompanied by delayed onset of muscle soreness, is a leading cause of the loss of mobility in the rapidly increasing population of elderly people. Unlike other types of muscle injuries which hurt almost exclusively those...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-014-1173-7
更新日期:2015-02-01 00:00:00
abstract::Current efforts to evaluate the performance of laparoscopic arterial fusion devices are limited to costly, time consuming, empirical studies. Thus, a finite element (FE) model, with the ability to predict device performance would improve device design and reduce development time and costs. This study introduces a mode...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1588-4
更新日期:2016-11-01 00:00:00
abstract::Auscultation is an important diagnostic indicator for cardiovascular analysis. Heart sound classification and analysis play an important role in the auscultative diagnosis. This study uses a combination of Mel-frequency cepstral coefficient (MFCC) and hidden Markov model (HMM) to efficiently extract the features for p...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9232-3
更新日期:2007-03-01 00:00:00
abstract::In this paper, an intelligent proportional-integral-derivative (PID) control method is introduced to the robotic testing system for the biomechanical study of human musculoskeletal joints. For the testing system, the robot is a highly nonlinear and heavily coupled complicated system, and the human spinal specimen also...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1023/b:abme.0000030759.80354.e8
更新日期:2004-06-01 00:00:00
abstract::A mathematical model of heat, water and soluble gas exchange in the airways and alveoli was used to predict the location of soluble gas exchange in the lung. A previously published model of heat, water and soluble gas exchange in the airways was improved by incorporating anatomical data on the airway wall to better de...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1630600
更新日期:2003-12-01 00:00:00
abstract::This study presents a new steady-state visual evoked potential (SSVEP)-based brain computer interface (BCI). SSVEPs, induced by phase-tagged flashes in eight light emitting diodes (LEDs), were used to control four cursor movements (up, right, down, and left) and four button functions (on, off, right-, and left-clicks)...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9964-y
更新日期:2010-07-01 00:00:00
abstract::Defibrillation efficacy testing is a common procedure at defibrillator implantation, with the objective to ensure that each patient receives a system with adequate shock efficacy. In this study, defibrillation shock efficacy as a function of shock energy was modeled by a dose response relationship. The frequency distr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9890-z
更新日期:2010-04-01 00:00:00
abstract::In vitro and in vivo studies were conducted on omega-3 fatty acid-derived biomaterials to determine their utility as an implantable material for adhesion prevention following soft tissue hernia repair and as a means to allow for the local delivery of antimicrobial or antibiofilm agents. Naturally derived biomaterials ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1489-y
更新日期:2016-03-01 00:00:00
abstract::Icariin (Ic) has been demonstrated as a potent osteoinductive compound for bone tissue engineering. However, toxic side effects of the drug and poor biocompatibility of drug delivery systems (DDSs) still limit its application for bone repair in the clinic. To overcome these disadvantages and utilize the osteoinductivi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1900-y
更新日期:2017-11-01 00:00:00