Abstract:
:Icariin (Ic) has been demonstrated as a potent osteoinductive compound for bone tissue engineering. However, toxic side effects of the drug and poor biocompatibility of drug delivery systems (DDSs) still limit its application for bone repair in the clinic. To overcome these disadvantages and utilize the osteoinductivity of Ic, we developed a novel method to utilize Ic as an Ic-derived osteoinductive extracellular matrix (ECM) on small intestinal submucosa (SIS) (Ic-ECM-SIS). The generated Ic-ECM-SIS scaffolds, as a natural construct, exhibited much better biocompatibility (including cell adhesion, cell survival and cell proliferation) than Ic-SIS scaffolds generated by traditional DDSs. Meanwhile, osteogenic differentiation was promoted by Ic-ECM-SIS with higher expression of alkaline phosphatase, bone sialoprotein and osteocalcin than ECM-SIS, which was same as Ic-SIS. BMP-4 expression was further increased in the cells on Ic-ECM-SIS compared to that on Ic-SIS. A mouse calvarial defect model was introduced to evaluate the function of Ic-ECM-SIS on bone regeneration in vivo. The bone regeneration was enhanced in the defects implanted with Ic-ECM-SIS, with a higher new bone formation ratio (BV/TV) than the defects implanted with ECM-SIS or Ic-SIS. Angiogenesis was also promoted by Ic-ECM-SIS implantation when compared with ECM-SIS or Ic-SIS. Thus, this work proposes a novel method for applying a drug as a drug-derived ECM-modified scaffold for bone tissue engineering.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Li M,Zhang C,Zhong Y,Zhao Jdoi
10.1007/s10439-017-1900-ysubject
Has Abstractpub_date
2017-11-01 00:00:00pages
2673-2682issue
11eissn
0090-6964issn
1573-9686pii
10.1007/s10439-017-1900-yjournal_volume
45pub_type
杂志文章abstract::Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1688-1
更新日期:2016-12-01 00:00:00
abstract::The combination of gene therapy and chemotherapy has showed increased therapeutic efficacy in the treatment of cancers, but it is not well investigated about the actual coordination pattern between therapeutic gene and chemical drug. In this work, p53/BPEI-β-CD/AD-dox complex was fabricated and employed to investigate...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-016-1627-1
更新日期:2016-11-01 00:00:00
abstract::Mechanical ventilation is a life-support therapy for intensive care patients suffering from respiratory failure. To reduce the current rate of ventilator-induced lung injury requires ventilator settings that are patient-, time-, and disease-specific. A common lung protective strategy is to optimise the level of positi...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1007/s10439-019-02253-w
更新日期:2019-07-01 00:00:00
abstract::Elastin is an essential component of arteries which provides structural integrity and instructs smooth muscle cells to adopt a quiescent state. Despite interaction of endothelial cells with elastin in the internal elastic lamina, the potential for exploiting this interaction therapeutically has not been explored in de...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0142-z
更新日期:2011-01-01 00:00:00
abstract::A study that customizes the feature generator parameters of an asynchronous Brain Interface (BI) is discussed. The goal is to detect the presence of a certain pattern, in the ongoing EEG, associated with a specific movement and to improve the system's performance. Results of this study show that customization mostly b...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9097-5
更新日期:2006-06-01 00:00:00
abstract::Much effort is expended in developing biomimetic scaffolds that provide the micro-architecture of native tissue with appropriate cellular niches. Such scaffolds are often seeded with progenitor cells to generate engineered replacements for diseased or damaged tissues. An alternative approach relies on biology, rather ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-014-1174-6
更新日期:2015-03-01 00:00:00
abstract::The aim of this study was to test the differentiative effects of osteoblasts after treatment with a static magnetic field (SMF). MG63 osteoblast-like cells were exposed to a 0.4-T SMF. The differentiation markers were assessed by observing the changes in alkaline phosphatase activity and electron microscopy images. Me...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-007-9370-2
更新日期:2007-11-01 00:00:00
abstract::Cardiac MRI (CMR) techniques offer non-invasive visualizations of cardiac morphology and function. However, imaging can be time-consuming and complex. Seismocardiography (SCG) measures physical vibrations transmitted through the chest from the beating heart and pulsatile blood flow. SCG signals can be acquired quickly...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02491-3
更新日期:2020-06-01 00:00:00
abstract::This study evaluates the use of artificial neural networks to estimate stroke volume from pre-processed, thoracic impedance plethysmograph signals from 20 healthy subjects. Standard back-propagation was used to train the networks, with Doppler stroke volume estimates as the desired output. The trained networks were th...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.47
更新日期:1998-07-01 00:00:00
abstract::The study was to explore the effects of BMP-2 gene modified canine bone marrow stromal cells (bMSCs) mediated by a nonviral PEI derivative (GenEscort™ II) in promoting bone formation in vitro and in vivo. Canine bMSCs were cultured and transfected with plasmids containing bone morphogenetic protein-2 gene (pBMP-2) or ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0276-7
更新日期:2011-06-01 00:00:00
abstract::Wall stress analysis of abdominal aortic aneurysm (AAA) is a promising method of identifying AAAs at high risk of rupture. However, neglecting residual strains (RS) in the load-free configuration of patient-specific finite element analysis models is a sever limitation that strongly affects the computed wall stresses. ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0749-y
更新日期:2013-07-01 00:00:00
abstract::Correct development of neuronal tracts requires the coordination of multiple permissive and inhibitory signals. By generating an in vitro microenvironment using soft lithography and microfluidic techniques, multiple guidance cues can be presented in a spatially defined way. Here we evaluated how neurites of dorsal roo...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9486-z
更新日期:2008-06-01 00:00:00
abstract::Current induced in cultured cerebellar granule cells by the bath application of kainate (500 microM) was measured using the conventional patch-clamp technique. Two different kinds of responses were observed after the agonist perfusion. Some cells exhibited small inward whole-cell currents: 116 +/- 40 pA (7 cells) at a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02684186
更新日期:1997-05-01 00:00:00
abstract::Despite the clinical effectiveness of coronary artery stenting, percutaneous coronary intervention or "stenting" is not free of complications. Stent malapposition (SM) is a common feature of "stenting" particularly in challenging anatomy, such as that characterized by long, tortuous and bifurcated segments. SM is an i...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1237-8
更新日期:2015-08-01 00:00:00
abstract::The optimal means of electrically stimulating a skeletal muscle to contract around a fluid-filled pouch (i.e., a skeletal muscle ventricle [SMV]) has not been determined. A SMV was made from the latissimus dorsi muscle in five dogs and the rectus abdominis muscle in five dogs, and each SMV was electrically stimulated ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02364611
更新日期:1990-01-01 00:00:00
abstract::The left-right asymmetry in the potential amplitude on the scalp was studied in poststroke patients by using flash visual evoked potential (VEP) and a numerical two-dimensional model of the head. The left-right asymmetry of the VEP was measured in three patients after thrombosis, in one after hemorrhage, and in one he...
journal_title:Annals of biomedical engineering
pub_type: 临床试验,杂志文章
doi:10.1007/BF02770997
更新日期:1996-01-01 00:00:00
abstract::Acute cerebral ischemic events and thrombosis are associated with the rupture/erosion of carotid atherosclerotic plaques. The aim of the present study was to determine the impact of calcification deposition on the wall shear stress (WSS) and stresses within the plaques using 3D fluid-structure interaction (FSI) models...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02655-1
更新日期:2020-10-20 00:00:00
abstract::Past literature has provided evidence that a normal mechanical force environment of blood flow may guide normal development while an abnormal environment can lead to congenital malformations, thus warranting further studies on embryonic cardiovascular flow dynamics. In the current study, we developed a non-invasive 4D...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1882-9
更新日期:2017-10-01 00:00:00
abstract::The manner in which energy from an explosion is transmitted into the brain is currently a highly debated topic within the blast injury community. This study was conducted to investigate the injury biomechanics causing blast-related neurotrauma in the rat. Biomechanical responses of the rat head under shock wave loadin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-011-0343-0
更新日期:2011-10-01 00:00:00
abstract::Arterial restenosis following stent deployment may be influenced by the local flow environment within and around the stent. We have used computational fluid dynamics to investigate the flow field in the vicinity of model stents positioned within straight and curved vessels. Our simulations have revealed the presence o...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-2499-y
更新日期:2005-04-01 00:00:00
abstract::The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V (Abbott Vascular), TAXUS Liberté (Boston Scientific), Endeavor (Medtronic), and Cypher (J&J Cordis)] and a bare-...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-009-9697-y
更新日期:2009-07-01 00:00:00
abstract::Development of increasingly complex integrated cellular systems will be a major challenge for the next decade and beyond, as we apply the knowledge gained from the sub-disciplines of regenerative medicine, synthetic biology, micro-fabrication and nanotechnology, systems biology, and developmental biology. In this pros...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-013-0902-7
更新日期:2014-02-01 00:00:00
abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.110
更新日期:1998-09-01 00:00:00
abstract::Fractal time series analysis methods are commonly used for analyzing center of pressure (COP) signals with the goal of revealing the underlying neuromuscular processes for upright stance control. The use of fractal methods is often coupled with the assumption that the COP is an instance of fractional Gaussian noise (f...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0646-9
更新日期:2013-08-01 00:00:00
abstract::The cerebral blood flow (CBF) response to changes in perfusion pressure mediated through decreases in arterial pressure, increases in cerebrospinal fluid (CSF) pressure and increases in jugular venous pressure was studied in anesthetized dogs. A preparation was developed in which each of the three relevant pressures c...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02584249
更新日期:1985-01-01 00:00:00
abstract::We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstru...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1463-8
更新日期:2016-05-01 00:00:00
abstract::The pulmonary microvasculature offers a heterogeneous barrier to the motion of large solutes as they pass between blood and lymph. While this barrier has been approximated by a few discrete pathways or by statistical ensembles of many pathways, these descriptions only partly capture the structural and functional prope...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02368425
更新日期:1990-01-01 00:00:00
abstract::While virtual reality (VR) has potential in enhancing cardiovascular diagnosis and treatment, prerequisite labor-intensive image segmentation remains an obstacle for seamlessly simulating 4-dimensional (4-D, 3-D + time) imaging data in an immersive, physiological VR environment. We applied deformable image registratio...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-018-02113-z
更新日期:2018-12-01 00:00:00
abstract::In the field of fluid flow within the human body, focus has been placed on the transportation of blood in the systemic circulation since the discovery of that system; but, other fluids and fluid flow phenomena pervade the body. Some of the most fascinating fluid flow phenomena within the human body involve fluids othe...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-9902-z
更新日期:2010-03-01 00:00:00
abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-004-7820-7
更新日期:2004-12-01 00:00:00