Organ Dynamics and Fluid Dynamics of the HH25 Chick Embryonic Cardiac Ventricle as Revealed by a Novel 4D High-Frequency Ultrasound Imaging Technique and Computational Flow Simulations.

Abstract:

:Past literature has provided evidence that a normal mechanical force environment of blood flow may guide normal development while an abnormal environment can lead to congenital malformations, thus warranting further studies on embryonic cardiovascular flow dynamics. In the current study, we developed a non-invasive 4D high-frequency ultrasound technique, and use it to analyze cardiovascular organ dynamics and flow dynamics. Three chick embryos at stage HH25 were scanned with high frequency ultrasound in cine-B-mode at multiple planes spaced at 0.05 mm. 4D images of the heart and nearby arteries were generated via temporal and spatial correlation coupled with quadratic mean ensemble averaging. Dynamic mesh CFD was performed to understand the flow dynamics in the ventricle of the 2 hearts. Our imaging technique has sufficiently high resolution to enable organ dynamics quantification and CFD. Fine structures such as the aortic arches and details such as the cyclic distension of the carotid arteries were captured. The outflow tract completely collapsed during ventricular diastole, possible serving the function of a valve to prevent regurgitation. CFD showed that ventricular wall shear stress (WSS) were in the range of 0.1-0.5 Pa, and that the left side of the common ventricle experienced lower WSS than the right side. The pressure gradient from the inlet to the outlet of the ventricle was positive over most of the cardiac cycle, and minimal regurgitation flow was observed, despite the absence of heart valves. We developed a new image-based CFD method to elucidate cardiac organ dynamics and flow dynamics of embryonic hearts. The embryonic heart appeared to be optimized to generate net forward flow despite the absence of valves, and the WSS environment appeared to be side-specific.

journal_name

Ann Biomed Eng

authors

Ho S,Tan GXY,Foo TJ,Phan-Thien N,Yap CH

doi

10.1007/s10439-017-1882-9

subject

Has Abstract

pub_date

2017-10-01 00:00:00

pages

2309-2323

issue

10

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-017-1882-9

journal_volume

45

pub_type

杂志文章
  • Estrogen Preserves Pulsatile Pulmonary Arterial Hemodynamics in Pulmonary Arterial Hypertension.

    abstract::Pulmonary arterial hypertension (PAH) is caused by extensive pulmonary vascular remodeling that increases right ventricular (RV) afterload and leads to RV failure. PAH predominantly affects women; paradoxically, female PAH patients have better outcomes than men. The roles of estrogen in PAH remain controversial, which...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1716-1

    authors: Liu A,Hacker T,Eickhoff JC,Chesler NC

    更新日期:2017-03-01 00:00:00

  • Arterial luminal curvature and fibrous-cap thickness affect critical stress conditions within atherosclerotic plaque: an in vivo MRI-based 2D finite-element study.

    abstract::High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FC(MIN)) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the s...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0078-3

    authors: Teng Z,Sadat U,Li Z,Huang X,Zhu C,Young VE,Graves MJ,Gillard JH

    更新日期:2010-10-01 00:00:00

  • Errors caused by combination of Di-4 ANEPPS and Fluo3/4 for simultaneous measurements of transmembrane potentials and intracellular calcium.

    abstract::Intracellular calcium concentration and transmembrane potentials are two important measurements used to study the mechanisms of cardiac activity. Fluorescent dyes have been used to measure these separately but not simultaneously in cardiac tissue. Fluo-3 and Fluo-4 (a recently improved version of Fluo-3) have been use...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.198

    authors: Johnson PL,Smith W,Baynham TC,Knisley SB

    更新日期:1999-07-01 00:00:00

  • Advection and diffusion of substances in biological tissues with complex vascular networks.

    abstract::For highly diffusive solutes the kinetics of blood-tissue exchange is only poorly represented by a model consisting of sets of independent parallel capillary-tissue units. We constructed a more realistic multicapillary network model conforming statistically to morphometric data. Flows through the tortuous paths in the...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.273

    authors: Beard DA,Bassingthwaighte JB

    更新日期:2000-03-01 00:00:00

  • 3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

    abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1678-3

    authors: Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

    更新日期:2017-01-01 00:00:00

  • Biomechanical Properties and Microstructure of Heart Chambers: A Paired Comparison Study in an Ovine Model.

    abstract::Mechanical properties of the cardiac tissue play an important role in normal heart function. The goal of this study was to determine the passive mechanical properties of all heart chambers through a paired comparison study in an ovine model. Ovine heart was used due its physiological and anatomical similarities to hum...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1658-7

    authors: Javani S,Gordon M,Azadani AN

    更新日期:2016-11-01 00:00:00

  • Gaussian pulse decomposition: an intuitive model of electrocardiogram waveforms.

    abstract::This study presents a novel approach to modeling the electrocardiogram (ECG): the Gaussian pulse decomposition. Constituent waves of the ECG are decomposed into and represented by Gaussian pulses using an iterative algorithm: the chip away decomposition (ChAD) algorithm. At each iteration, a nonlinear minimization met...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02648039

    authors: Suppappola S,Sun Y,Chiaramida SA

    更新日期:1997-03-01 00:00:00

  • A device for imposing cyclic strain to cells growing on implant alloys.

    abstract::The objective of this study was to develop a unique device for applying well-characterized cyclic, strain to cells growing on implant alloys. The device is based on the four-point bending principle and utilizes an electric motor, belt, and cam system to cyclically deflect a commercially pure titanium plate with cell c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1529195

    authors: Winter LC,Gilbert JA,Elder SH,Bumgardner JD

    更新日期:2002-11-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE

    更新日期:2016-10-01 00:00:00

  • High-resolution measurement of the unsteady velocity field to evaluate blood damage induced by a mechanical heart valve.

    abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0329-y

    authors: Bellofiore A,Quinlan NJ

    更新日期:2011-09-01 00:00:00

  • Strength and electron features of irradiated bone.

    abstract::Radiation applied for therapy and diagnostics damages molecular/atomic couples of biotissues, bones being among them. As a result, electron peculiarities and mechanical behavior of the latter are altered. Correlation between strength of the irradiated bone and its electron features explored due to photo- and exoelectr...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1424911

    authors: Dekhtyar Y

    更新日期:2001-12-01 00:00:00

  • Development of an arbitrary waveform membrane stretcher for dynamic cell culture.

    abstract::In this paper, a novel cell stretcher design that mimics the real-time stretch of the heart wall is introduced. By culturing cells under stretched conditions that mimics the mechanical aspects of the native cardiac environment, better understanding on the role of biomechanical signaling on cell development can be achi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0976-x

    authors: Lau JJ,Wang RM,Black LD 3rd

    更新日期:2014-05-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • Cerebrovascular transmural pressure and autoregulation.

    abstract::The cerebral blood flow (CBF) response to changes in perfusion pressure mediated through decreases in arterial pressure, increases in cerebrospinal fluid (CSF) pressure and increases in jugular venous pressure was studied in anesthetized dogs. A preparation was developed in which each of the three relevant pressures c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584249

    authors: Wagner EM,Traystman RJ

    更新日期:1985-01-01 00:00:00

  • Geodesic based registration of sensor data and anatomical surface image data.

    abstract::This paper presents two related methods for registering an image of an anatomical object with data from sensors arranged on the object. One method is described with reference to a test case involving a rectangular electrode plaque disposed on a heart surface, which is imaged with MRI. Data from the electrodes is fused...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9350-6

    authors: Hopenfeld B,Ashikaga H,McVeigh ER

    更新日期:2007-10-01 00:00:00

  • Customised Selection of the Haptic Design in C-Loop Intraocular Lenses Based on Deep Learning.

    abstract::In order to increase the probability of having a successful cataract post-surgery, the customisation of the haptic design of the intraocular lens (IOL) according to the characteristics of the patient is recommended. In this study, we present two prediction models based on deep neural networks (DNNs). One is capable of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02636-4

    authors: Cabeza-Gil I,Ríos-Ruiz I,Calvo B

    更新日期:2020-12-01 00:00:00

  • Pixel-Based DXA-Derived Structural Properties Strongly Correlate with pQCT Measures at the One-Third Distal Femur Site.

    abstract::While bone mineral density has been traditionally used to quantify fracture risk for individuals with spinal cord injuries, recent studies are including engineering measurements such as section modulus and cross sectional moment of inertia. These are almost exclusively calculated by peripheral QCT scanners which, unli...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1796-6

    authors: Baker AM,Wagner DW,Kiratli BJ,Beaupre GS

    更新日期:2017-05-01 00:00:00

  • Two methods for recommending bat weights.

    abstract::Baseball players swung very light and very heavy bats through our instrument and the speed of the bat was recorded. These data were used to make mathematical models for each person. Then these models were coupled with equations of physics for bat-ball collisions to compute the Ideal Bat Weight for each individual. How...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584443

    authors: Bahill AT,Freitas MM

    更新日期:1995-07-01 00:00:00

  • Numerical validation of MR-measurement-integrated simulation of blood flow in a cerebral aneurysm.

    abstract::This study proposes magnetic resonance (MR)-measurement-integrated (MR-MI) simulation, in which the difference between the computed velocity field and the phase-contrast MRI measurement data is fed back to the numerical simulation. The computational accuracy and the fundamental characteristics, such as steady characte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9689-y

    authors: Funamoto K,Suzuki Y,Hayase T,Kosugi T,Isoda H

    更新日期:2009-06-01 00:00:00

  • Mechanics of a thin walled collapsible microtube.

    abstract::The purpose of this study is to measure the transmural pressure-cross sectional area relation of micro tubes (240 microns diameter) and to compare the measured perfusion pressure-flow relation with the pressure-flow relation calculated from the experimental pressure-cross sectional area relation. The microtubes are ma...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368042

    authors: Sipkema P,Westerhof N

    更新日期:1989-01-01 00:00:00

  • Adhesion of microfabricated particles on vascular endothelium: a parametric analysis.

    abstract::"Smart" drug delivery systems should be selective and effective to ensure drug administration at the right time, at the right dosage, and anywhere in the body. Among the several administration routes and delivery systems that have been proposed, one of the most effective and promising is based on microfabricated parti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030255.36748.d3

    authors: Decuzzi P,Lee S,Decuzzi M,Ferrari M

    更新日期:2004-06-01 00:00:00

  • Surfactant properties differentially influence intravascular gas embolism mechanics.

    abstract::Gas bubble motion in a blood vessel causes temporal and spatial gradients of shear stress at the cell surface lining the vessel wall as the bubble approaches the cell, moves over it and passes it by. Rapid reversals occur in the sign of the shear stress imparted to the cell surface during this motion. These may result...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0120-5

    authors: Swaminathan TN,Ayyaswamy PS,Eckmann DM

    更新日期:2010-12-01 00:00:00

  • Compressive deformation and damage of muscle cell subpopulations in a model system.

    abstract::To study the effects of compressive straining on muscle cell deformation and damage an in vitro model system was developed. Myoblasts were seeded in agarose constructs and cultured in growth medium for 4 days. Subsequently, the cells were allowed to fuse into multinucleated myotubes for 8 days in differentiation mediu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1349698

    authors: Bouten CV,Knight MM,Lee DA,Bade DL

    更新日期:2001-02-01 00:00:00

  • Restoring Ovarian Endocrine Function with Encapsulated Ovarian Allograft in Immune Competent Mice.

    abstract::Premature ovarian insufficiency (POI) is a major complication of cytotoxic treatments due to extreme ovarian sensitivity to chemotherapy and radiation. In pediatric cancer patients modern therapy has improved the long-term survival to over 80% in the United States. However, these cancer survivors face long-term health...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1780-6

    authors: David A,Day JR,Cichon AL,Lefferts A,Cascalho M,Shikanov A

    更新日期:2017-07-01 00:00:00

  • Fatigue of Metallic Stents: From Clinical Evidence to Computational Analysis.

    abstract::The great success of stents in treating cardiovascular disease is actually undermined by their long-term fatigue failure. The high variability of stent failure incidence suggests that it is due to several correlated aspects, such as loading conditions, material properties, component design, surgical procedure, and pat...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1447-8

    authors: Auricchio F,Constantinescu A,Conti M,Scalet G

    更新日期:2016-02-01 00:00:00

  • Automatic Model Generation Framework for Computational Simulation of Cochlear Implantation.

    abstract::Recent developments in computational modeling of cochlear implantation are promising to study in silico the performance of the implant before surgery. However, creating a complete computational model of the patient's anatomy while including an external device geometry remains challenging. To address such a challenge, ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1541-y

    authors: Mangado N,Ceresa M,Duchateau N,Kjer HM,Vera S,Dejea Velardo H,Mistrik P,Paulsen RR,Fagertun J,Noailly J,Piella G,González Ballester MÁ

    更新日期:2016-08-01 00:00:00

  • Characterizing the variability of system kernel and input estimates.

    abstract::The identification of the input to, or kernels of, a system using nonparametric representations and least-squares estimation is becoming increasingly popular. Nonparametric representations avoid making a priori assumptions about the input or having detailed knowledge about the system, and only need to guarantee known ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.110

    authors: Verotta D

    更新日期:1998-09-01 00:00:00

  • An experimental evaluation of the use of an ensemble average for the calculation of turbulence in pulsatile flow.

    abstract::A comparison was made between turbulence calculated by subtracting an ensemble average from the instantaneous velocity and calculations made with a high pass digital filter. Velocity was measured with a laser Doppler anemometer in vitro in the region of a normal porcine aortic valve and in patients with a hot film ane...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584215

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1983-01-01 00:00:00

  • Optical Metabolic Imaging for Assessment of Radiation-Induced Injury to Rat Kidney and Mitigation by Lisinopril.

    abstract::The kidney is one of the most radiosensitive organs; it is the primary dose-limiting organ in radiotherapies for upper abdominal cancers. The role of mitochondrial redox state in the development and treatment of renal radiation injury, however, remains ill-defined. This study utilizes 3D optical cryo-imaging to quanti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02255-8

    authors: Mehrvar S,la Cour MF,Medhora M,Camara AKS,Ranji M

    更新日期:2019-07-01 00:00:00