:Fractal time series analysis methods are commonly used for analyzing center of pressure (COP) signals with the goal of revealing the underlying neuromuscular processes for upright stance control. The use of fractal methods is often coupled with the assumption that the COP is an instance of fractional Gaussian noise (fGn) or fractional Brownian motion (fBm). Our purpose was to evaluate the applicability of the fGn-fBm framework to the COP in light of several characteristics of COP signals revealed by a new method, adaptive fractal analysis (AFA). AFA quantifies how the variance of the residuals to fits of a globally smooth trend signal scales with the time scale at which the fits are performed. Application of AFA to COP signals revealed that there are potentially three fractal scaling regions in the COP as opposed to one as expected from a pure fGn or fBm process. The scaling region at the fastest scale was anti-persistent and spanned ~30-90 ms, the intermediate was persistent and spanned ~200 ms-1.9 s, and the slowest was anti-persistent and spanned ~5-40 s. The intermediate fractal scaling region was the most clearly defined, but it only contributed around 11% of the total spectral energy of the COP signal, indicating that other features of the COP signal contribute more importantly to the overall dynamics. Also, more than half of the Hurst exponents estimated for the intermediate region were greater than the theoretically expected range [0,1] for fGn-fBm processes. These results suggest the fGn-fBm framework is not appropriate for modeling COP signals. ON-OFF intermittency might provide a better modeling framework for the COP, and multiscale approaches may be more appropriate for analyzing COP data.

journal_name

Ann Biomed Eng

authors

Kuznetsov N,Bonnette S,Gao J,Riley MA

doi

10.1007/s10439-012-0646-9

subject

Has Abstract

pub_date

2013-08-01 00:00:00

pages

1646-60

issue

8

eissn

0090-6964

issn

1573-9686

journal_volume

41

pub_type

杂志文章
  • In vitro, time-resolved PIV comparison of the effect of stent design on wall shear stress.

    abstract::The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V (Abbott Vascular), TAXUS Liberté (Boston Scientific), Endeavor (Medtronic), and Cypher (J&J Cordis)] and a bare-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9697-y

    authors: Charonko J,Karri S,Schmieg J,Prabhu S,Vlachos P

    更新日期:2009-07-01 00:00:00

  • Cue-Signal-Response Analysis in 3D Chondrocyte Scaffolds with Anabolic Stimuli.

    abstract::Articular cartilage is an avascular connective tissue responsible for bearing loads. Cell signaling plays a central role in cartilage homeostasis and tissue engineering by directing chondrocytes to synthesize/degrade the extracellular matrix or promote inflammatory responses. The aim of this paper was to investigate a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1964-8

    authors: Neidlin M,Korcari A,Macheras G,Alexopoulos LG

    更新日期:2018-02-01 00:00:00

  • Modeling life.

    abstract::We seek to construct physical and mathematical models of life. Such models allow us to test our understanding of how living systems function and how they respond to human imposed stimuli. One system is a genomically and chemically complete model of a minimal cell. This cell is a hypothetical bacterium with the fewest ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-012-0567-7

    authors: Shuler ML

    更新日期:2012-07-01 00:00:00

  • A novel method for visualization of entire coronary arterial tree.

    abstract::The complexity of the coronary circulation especially in the deep layers largely evades experimental investigations. Hence, virtual/computational models depicting structure-function relation of the entire coronary vasculature including the deep layer are imperative. In order to interpret such anatomically based models...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9278-x

    authors: Wischgoll T,Meyer J,Kaimovitz B,Lanir Y,Kassab GS

    更新日期:2007-05-01 00:00:00

  • Functional augmentation of naturally-derived materials for tissue regeneration.

    abstract::Tissue engineering strategies have utilized a wide spectrum of synthetic and naturally-derived scaffold materials. Synthetic scaffolds are better defined and offer the ability to precisely and reproducibly control their properties, while naturally-derived scaffolds typically have inherent biological and structural pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1192-4

    authors: Allen AB,Priddy LB,Li MT,Guldberg RE

    更新日期:2015-03-01 00:00:00

  • Fecobionics: A Novel Bionics Device for Studying Defecation.

    abstract::During defecation, solid, semisolid or liquid stools are eliminated via the anus in a complex physiological process. Up to 25% of the population are affected by anorectal disorders that are poorly recognized and treated. We developed a new bionics device, a simulated stool named Fecobionics, to replace several current...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02149-1

    authors: Sun D,Huang Z,Zhuang Z,Ma Z,Man LK,Liao D,Gregersen H

    更新日期:2019-02-01 00:00:00

  • Cellular and Nuclear Alignment Analysis for Determining Epithelial Cell Chirality.

    abstract::Left-right (LR) asymmetry is a biologically conserved property in living organisms that can be observed in the asymmetrical arrangement of organs and tissues and in tissue morphogenesis, such as the directional looping of the gastrointestinal tract and heart. The expression of LR asymmetry in embryonic tissues can be ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1431-3

    authors: Raymond MJ Jr,Ray P,Kaur G,Singh AV,Wan LQ

    更新日期:2016-05-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • Linear homeomorphic models for muscles in the head-neck region.

    abstract::The linear homeomorphic muscle model proposed by Enderle and coworkers for the rectus eye muscle is fitted to reflect the dynamics of muscles in the head-neck complex, specifically in muscles involved in gaze shifts. This parameterization of the model for different muscles in the neck region will serve to drive a 3D d...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9851-6

    authors: Sierra DA,Enderle JD

    更新日期:2010-02-01 00:00:00

  • A model for detecting balance impairment and estimating falls risk in the elderly.

    abstract::Traumatic falls are a prevalent and costly threat to elderly adults. Accurate risk assessment is necessary for reducing incidence of falls. The objective of this study was to test the feasibility of a balance impairment detection model using tasks of sample categorization and falls risk estimation. Model design includ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2867-7

    authors: Hahn ME,Chou LS

    更新日期:2005-06-01 00:00:00

  • Numerical simulation of cell motion in tube flow.

    abstract::A theoretical model is presented for describing the motion of a deformable cell encapsulating a Newtonian fluid and enclosed by an elastic membrane in tube flow. In the mathematical formulation, the interior and exterior hydrodynamics are coupled with the membrane mechanics by means of surface equilibrium equations, a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8975-6

    authors: Pozrikidis C

    更新日期:2005-02-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • Theoretical study of the effects of vascular smooth muscle contraction on strain and stress distributions in arteries.

    abstract::To study the effects of smooth muscle contraction and relaxation on the strain and stress distribution in the vascular wall, a mathematical model was proposed. The artery was assumed to be a thick-walled orthotropic tube made of nonlinear, incompressible elastic material. Considering that the contraction of smooth mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.191

    authors: Rachev A,Hayashi K

    更新日期:1999-07-01 00:00:00

  • Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?

    abstract::Dual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1914-5

    authors: Rezaei A,Giambini H,Rossman T,Carlson KD,Yaszemski MJ,Lu L,Dragomir-Daescu D

    更新日期:2017-12-01 00:00:00

  • Probabilistic evaluation of predicted force sensitivity to muscle attachment and glenohumeral stability uncertainty.

    abstract::A major benefit of computational modeling in biomechanics research is its ability to estimate internal muscular demands given limited input information. However, several assumptions regarding model parameters and constraints may influence model outputs. This research evaluated the influence of model parameter variabil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1035-3

    authors: Chopp-Hurley JN,Langenderfer JE,Dickerson CR

    更新日期:2014-09-01 00:00:00

  • Comparison of Covered Laser-cut and Braided Respiratory Stents: From Bench to Pre-Clinical Testing.

    abstract::Lung cancer patients often suffer from severe airway stenosis, the symptoms of which can be relieved by the implantation of stents. Different respiratory stents are commercially available, but the impact of their mechanical performance on tissue responses is not well understood. Two novel laser-cut and hand-braided ni...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02278-1

    authors: Thiebes AL,McGrath DJ,Kelly N,Sweeney CA,Kurtenbach K,Gesché VN,Clauser J,O'Brien B,Bruzzi M,McHugh PE,Jockenhoevel S,Cornelissen CG

    更新日期:2019-08-01 00:00:00

  • Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model.

    abstract::Congenital heart disease is the leading cause of infant death in the United States with over 36,000 newborns affected each year. Despite this growing problem there are few mechanical circulatory support devices designed specifically for pediatric and neonate patients. Previous research has been done investigating pedi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1370-z

    authors: Good BC,Deutsch S,Manning KB

    更新日期:2016-04-01 00:00:00

  • Effects of External and Internal Hyperthermia on LDL Transport and Accumulation Within an Arterial Wall in the Presence of a Stenosis.

    abstract::Effects of hyperthermia on transport of low-density lipoprotein (LDL) through a stenosed arterial wall are analyzed comprehensively in the present work. The realistic and pertinent aspects of an arterial wall is represented by a multi-layer model, with a proper representation of the thickened intima region due to the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1196-0

    authors: Iasiello M,Vafai K,Andreozzi A,Bianco N,Tavakkoli F

    更新日期:2015-07-01 00:00:00

  • Potential of the genetic algorithm neural network in the assessment of gait patterns in ankle arthrodesis.

    abstract::The aim of this study was to develop an empirical model of parameter-based gait data, based on an artificial neural network and a genetic algorithm, for the assessment of patients after ankle arthrodesis. Ground reaction force vectors were measured by force platforms during level walking. Nine force parameters express...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1114/1.1342053

    authors: Wu WL,Su FC,Cheng YM,Chou YL

    更新日期:2001-01-01 00:00:00

  • Native, living tissues as cell seeded scaffolds.

    abstract::Much effort is expended in developing biomimetic scaffolds that provide the micro-architecture of native tissue with appropriate cellular niches. Such scaffolds are often seeded with progenitor cells to generate engineered replacements for diseased or damaged tissues. An alternative approach relies on biology, rather ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1174-6

    authors: Evans CH

    更新日期:2015-03-01 00:00:00

  • Rat aortic smooth muscle cells contract in response to serum and its components in a calcium independent manner.

    abstract::Diluted serum provides a model of interstitial fluid that can be used to study the response of smooth muscle cells (SMCs) to interstitial flow. The effect of serum and some of its components on SMC contraction (area reduction) and intracellular calcium ([Ca2+]i) response were characterized in rat aortic SMC in vitro. ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-004-7820-7

    authors: Ainslie K,Shi ZD,Garanich JS,Tarbell JM

    更新日期:2004-12-01 00:00:00

  • Muscle-tendon model with length history-dependent activation-velocity coupling.

    abstract::We developed muscle-tendon models incorporating Hill-type structure and length-dependent coupling between activation and velocity. The models were evaluated in electrically stimulated cat soleus muscles. Dynamic model parameters were estimated by a nonlinear parameter estimation algorithm from input-output data obtain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.93

    authors: Shue GH,Crago PE

    更新日期:1998-05-01 00:00:00

  • A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

    abstract::The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9918-4

    authors: Ching CT,Sun TP,Huang SH,Shieh HL,Chen CY

    更新日期:2010-04-01 00:00:00

  • Velocity measurements within confined turbulent jets: application to cardiovalvular regurgitation.

    abstract::An expression for centerline mean velocity distributions for circular and noncircular confined turbulent jets has been obtained by assuming self-preservation of flow downstream of the jet potential core. It was assumed that the velocity decay was not only dependent on the streamwise distance x in terms of x/d, as in t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Liu H,Winoto SH,Shah DA

    更新日期:1997-11-01 00:00:00

  • Hemodynamic energy dissipation in the cardiovascular system: generalized theoretical analysis on disease states.

    abstract:BACKGROUND:We present a fundamental theoretical framework for analysis of energy dissipation in any component of the circulatory system and formulate the full energy budget for both venous and arterial circulations. New indices allowing disease-specific subject-to-subject comparisons and disease-to-disease hemodynamic ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9650-0

    authors: Dasi LP,Pekkan K,de Zelicourt D,Sundareswaran KS,Krishnankutty R,Delnido PJ,Yoganathan AP

    更新日期:2009-04-01 00:00:00

  • The effect of head rotation on the geometry and hemodynamics of healthy vertebral arteries.

    abstract::The geometric and hemodynamic characteristics of the left and right vertebral arteries (LVA, RVA) of six healthy volunteers were investigated for the supine (S) and the prone position (P) a common sleeping posture with head rotation. MRI images were used to reconstruct the subject specific three-dimensional solid mode...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1340-5

    authors: Aristokleous N,Seimenis I,Georgiou GC,Nicolaides A,Anayiotos AS

    更新日期:2015-06-01 00:00:00

  • Nonlinear dynamics of microvascular blood flow.

    abstract::Kiani et al. (Kiani, M. F., A. R. Pries, L. L. Hsu, I. H. Sarelius, and G. R. Cokelet, Am. J. Physics. 266: H1822-H1828, 1994) suggested that blood velocity, hematocrit, and nodal pressures can oscillate spontaneously in large microvascular networks in the absence of biological control. This paper presents a model of ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1306346

    authors: Carr RT,Lacoin M

    更新日期:2000-06-01 00:00:00

  • Development of FRET assay into quantitative and high-throughput screening technology platforms for protein-protein interactions.

    abstract::Förster resonance energy transfer (FRET) technology has been widely used in biological and biomedical research and is a very powerful tool in elucidating protein interactions in many cellular processes. Ubiquitination and SUMOylation are multi-step cascade reactions, involving multiple enzymes and protein-protein inte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0225-x

    authors: Song Y,Madahar V,Liao J

    更新日期:2011-04-01 00:00:00

  • A paradigm for functional tissue engineering of articular cartilage via applied physiologic deformational loading.

    abstract::Deformational loading represents a primary component of the chondrocyte physical environment in vivo. This review summarizes our experience with physiologic deformational loading of chondrocyte-seeded agarose hydrogels to promote development of cartilage constructs having mechanical properties matching that of the par...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1023/b:abme.0000007789.99565.42

    authors: Hung CT,Mauck RL,Wang CC,Lima EG,Ateshian GA

    更新日期:2004-01-01 00:00:00

  • A novel approach to track fetal movement using multi-sensor magnetocardiographic recordings.

    abstract::Changes in fetal magnetocardiographic (fMCG) signals are indicators for fetal body movement. We propose a novel approach to reliably extract fetal body movements based on the field strength of the fMCG signal independent of its frequency. After attenuating the maternal MCG, we use a Hilbert transform approach to ident...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0231-z

    authors: Govindan RB,Vairavan S,Ulusar UD,Wilson JD,McKelvey SS,Preissl H,Eswaran H

    更新日期:2011-03-01 00:00:00