Functional augmentation of naturally-derived materials for tissue regeneration.

Abstract:

:Tissue engineering strategies have utilized a wide spectrum of synthetic and naturally-derived scaffold materials. Synthetic scaffolds are better defined and offer the ability to precisely and reproducibly control their properties, while naturally-derived scaffolds typically have inherent biological and structural properties that may facilitate tissue growth and remodeling. More recently, efforts to design optimized biomaterial scaffolds have blurred the line between these two approaches. Naturally-derived scaffolds can be engineered through the manipulation of intrinsic properties of the pre-existing backbone (e.g., structural properties), as well as the addition of controllable functional components (e.g., biological properties). Chemical and physical processing techniques used to modify structural properties of synthetic scaffolds have been tailored and applied to naturally-derived materials. Such strategies include manipulation of mechanical properties, degradation, and porosity. Furthermore, biofunctional augmentation of natural scaffolds via incorporation of exogenous cells, proteins, peptides, or genes has been shown to enhance functional regeneration over endogenous response to the material itself. Moving forward, the regenerative mode of action of naturally-derived materials requires additional investigation. Elucidating such mechanisms will allow for the determination of critical design parameters to further enhance efficacy and capitalize on the full potential of naturally-derived scaffolds.

journal_name

Ann Biomed Eng

authors

Allen AB,Priddy LB,Li MT,Guldberg RE

doi

10.1007/s10439-014-1192-4

subject

Has Abstract

pub_date

2015-03-01 00:00:00

pages

555-67

issue

3

eissn

0090-6964

issn

1573-9686

journal_volume

43

pub_type

杂志文章,评审
  • Nanoparticle-Mediated TGF-β Release from Microribbon-Based Hydrogels Accelerates Stem Cell-Based Cartilage Formation In Vivo.

    abstract::Conventional nanoporous hydrogels often lead to slow cartilage deposition by MSCs in 3D due to physical constraints and requirement for degradation. Our group has recently reported macroporous gelatin microribbon (μRB) hydrogels, which substantially accelerate MSC-based cartilage formation in vitro compared to convent...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02522-z

    authors: Barati D,Gegg C,Yang F

    更新日期:2020-07-01 00:00:00

  • High-resolution measurement of the unsteady velocity field to evaluate blood damage induced by a mechanical heart valve.

    abstract::We investigate the potential of prosthetic heart valves to generate abnormal flow and stress patterns, which can contribute to platelet activation and lysis according to blood damage accumulation mechanisms. High-resolution velocity measurements of the unsteady flow field, obtained with a standard particle image veloc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0329-y

    authors: Bellofiore A,Quinlan NJ

    更新日期:2011-09-01 00:00:00

  • Comparison of Laboratory and On-Field Performance of American Football Helmets.

    abstract::The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck a...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02627-5

    authors: Bailey AM,McMurry TL,Cormier JM,Funk JR,Crandall JR,Mack CD,Myers BS,Arbogast KB

    更新日期:2020-11-01 00:00:00

  • Bioengineering the skin-implant interface: the use of regenerative therapies in implanted devices.

    abstract::This discussion and review article focuses on the possible use of regenerative techniques applied to the interfaces between skin and medical implants. As is widely known, the area of contact between an implant and the skin--the skin-implant interface--is prone to recurrent and persistent problems originated from the l...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-010-9937-1

    authors: Peramo A,Marcelo CL

    更新日期:2010-06-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Vortex ring formation in the left ventricle of the heart: analysis by 4D flow MRI and Lagrangian coherent structures.

    abstract::Recent studies suggest that vortex ring formation during left ventricular (LV) rapid filling is an optimized mechanism for blood transport, and that the volume of the vortex ring is an important measure. However, due to lack of quantitative methods, the volume of the vortex ring has not previously been studied. Lagran...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0615-3

    authors: Töger J,Kanski M,Carlsson M,Kovács SJ,Söderlind G,Arheden H,Heiberg E

    更新日期:2012-12-01 00:00:00

  • Motile Dendritic Cells Sense and Respond to Substrate Geometry.

    abstract::Dendritic cell (DC) migration is required for efficient presentation of antigen to T cells and the initiation of an adaptive immune response. In spite of its importance, many aspects of DC migration have not been characterized. DCs encounter a variety of environments with different stiffness and geometry, but the effe...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2041-7

    authors: Bendell AC,Anderson N,Blumenthal D,Williamson EK,Chen CS,Burkhardt JK,Hammer DA

    更新日期:2018-09-01 00:00:00

  • Aortic Valve Function Under Support of a Left Ventricular Assist Device: Continuous vs. Dynamic Speed Support.

    abstract::Continuous flow left ventricular devices (CF-LVADs) support the failing heart at a constant speed and alters the loads on the aortic valve. This may cause insufficiency in the aortic valve under long-term CF-LVAD support. The aim of this study is to assess the aortic valve function under varying speed CF-LVAD support....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1204-4

    authors: Bozkurt S,van de Vosse FN,Rutten MC

    更新日期:2015-08-01 00:00:00

  • Analyzing trends in brain interface technology: a method to compare studies.

    abstract::Continued progress in the field of Brain Interface (BI) research has encouraged the rapid expansion of the BI community over the last two decades. As the number of BI researchers and organizations steadily increases, newer and more advanced technologies are constantly produced, evaluated, and reported. Though the BI c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9055-7

    authors: Jackson MM,Mason SG,Birch GE

    更新日期:2006-05-01 00:00:00

  • Novel Balloon Surface Scanning Device for Intraoperative Breast Endomicroscopy.

    abstract::Recent advances in fluorescence confocal endomicroscopy have allowed real-time identification of residual tumour cells on the walls of the cavity left by breast conserving surgery. However, it is difficult to systematically survey the surgical site because of the small imaging field-of-view of these probes, compounded...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1493-2

    authors: Zuo S,Hughes M,Yang GZ

    更新日期:2016-07-01 00:00:00

  • Two methods for recommending bat weights.

    abstract::Baseball players swung very light and very heavy bats through our instrument and the speed of the bat was recorded. These data were used to make mathematical models for each person. Then these models were coupled with equations of physics for bat-ball collisions to compute the Ideal Bat Weight for each individual. How...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584443

    authors: Bahill AT,Freitas MM

    更新日期:1995-07-01 00:00:00

  • Micro-computed tomography based computational fluid dynamics for the determination of shear stresses in scaffolds within a perfusion bioreactor.

    abstract::Perfusion bioreactors are known to exert shear stresses on cultured cells, leading to cell differentiation and enhanced extracellular matrix deposition on scaffolds. The influence of the scaffold's porous microstructure is investigated for a polycaprolactone (PCL) scaffold with a regular microarchitecture and a silk f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-0981-0

    authors: Zermatten E,Vetsch JR,Ruffoni D,Hofmann S,Müller R,Steinfeld A

    更新日期:2014-05-01 00:00:00

  • Shear modulus of elasticity of the esophagus.

    abstract::Experimental and diagnostic procedures like distension of a balloon catheter, bougie, and esophagogastroduodenoscopy can induce shear deformation in the esophageal wall. However, the shear modulus of the esophagus is yet unknown. The aim of this study was to determine the esophageal shear modulus and its dependence on...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/b:abme.0000039356.24821.6c

    authors: Yang J,Liao D,Zhao J,Gregersen H

    更新日期:2004-09-01 00:00:00

  • Mechanical & cell culture properties of elastin-like polypeptide, collagen, bioglass, and carbon nanosphere composites.

    abstract::Collagen, the most commonly used extra-cellular matrix protein for tissue engineering applications, displays poor mechanical properties. Here, we report on the preparation and characterization of novel multi-component composite systems that incorporate a genetically engineered, biocompatible polymer (elastin-like poly...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0825-3

    authors: Wheeler TS,Sbravati ND,Janorkar AV

    更新日期:2013-10-01 00:00:00

  • Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.

    abstract::There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1781-5

    authors: Inoue Y,Yokota T,Sekitani T,Kaneko A,Woo T,Kobayashi S,Shibuya T,Tanaka M,Kosukegawa H,Saito I,Isoyama T,Abe Y,Yambe T,Someya T,Sekino M

    更新日期:2017-05-01 00:00:00

  • A Model to Study Articular Cartilage Mechanical and Biological Responses to Sliding Loads.

    abstract::In physiological conditions, joint function involves continuously moving contact areas over the tissue surface. Such moving contacts play an important role for the durability of the tissue. It is known that in pathological joints these motion paths and contact mechanics change. Nevertheless, limited information exists...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1543-9

    authors: Schätti OR,Gallo LM,Torzilli PA

    更新日期:2016-08-01 00:00:00

  • Validation of concussion risk curves for collegiate football players derived from HITS data.

    abstract::For several years, Virginia Tech and other schools have measured the frequency and severity of head impacts sustained by collegiate American football players in real time using the Head Impact Telemetry (HIT) System of helmet-mounted accelerometers. In this study, data from 37,128 head impacts collected at Virginia Te...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0400-8

    authors: Funk JR,Rowson S,Daniel RW,Duma SM

    更新日期:2012-01-01 00:00:00

  • Automatic Detection of Contracting Muscle Regions via the Deformation Field of Transverse Ultrasound Images: A Feasibility Study.

    abstract::Accurate identification of contracting muscles can help us to understand the muscle function in both physiological and pathological conditions. Conventional electromyography (EMG) have limited access to deep muscles, crosstalk, or instability in the recordings. Accordingly, a novel framework was developed to detect co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02557-2

    authors: Zheng Y,Shin H,Kamper DG,Hu X

    更新日期:2021-01-01 00:00:00

  • A COVID-19 Airway Management Innovation with Pragmatic Efficacy Evaluation: The Patient Particle Containment Chamber.

    abstract::The unique resource constraints, urgency, and virulence of the coronavirus disease 2019 pandemic has sparked immense innovation in the development of barrier devices to protect healthcare providers from infectious airborne particles generated by patients during airway management interventions. Of the existing devices,...

    journal_title:Annals of biomedical engineering

    pub_type: 社论

    doi:10.1007/s10439-020-02599-6

    authors: Maloney LM,Yang AH,Princi RA,Eichert AJ,Hébert DR,Kupec TV,Mertz AE,Vasyltsiv R,Vijaya Kumar TM,Walker GJ,Peralta EJ,Hoffman JL,Yin W,Page CR

    更新日期:2020-10-01 00:00:00

  • An Integrated In Vitro-In Silico Approach for Silver Nanoparticle Dosimetry in Cell Cultures.

    abstract::Potential human and environmental hazards resulting from the exposure of living organisms to silver nanoparticles (Ag NPs) have been the subject of intensive discussion in the last decade. Despite the growing use of Ag NPs in biomedical applications, a quantification of the toxic effects as a function of the total sil...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02449-5

    authors: Poli D,Mattei G,Ucciferri N,Ahluwalia A

    更新日期:2020-04-01 00:00:00

  • On the Compressibility of Arterial Tissue.

    abstract::Arterial tissue is commonly assumed to be incompressible. While this assumption is convenient for both experimentalists and theorists, the compressibility of arterial tissue has not been rigorously investigated. In the current study we present an experimental-computational methodology to determine the compressibility ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1417-1

    authors: Nolan DR,McGarry JP

    更新日期:2016-04-01 00:00:00

  • A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

    abstract::Functional outcomes, such as joint flexion and gait, are important indicators of efficacy in musculoskeletal research. Current technologies that objectively assess these parameters, including visual tracking systems and force plates, are challenging to deploy in long-term translational and clinical studies. To that en...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2105-8

    authors: Qu F,Stoeckl BD,Gebhard PM,Hullfish TJ,Baxter JR,Mauck RL

    更新日期:2018-12-01 00:00:00

  • Multi-scale computational models of pro-angiogenic treatments in peripheral arterial disease.

    abstract::The induction of angiogenesis is a promising therapeutic strategy for the amelioration of peripheral arterial disease (PAD). This occlusive disease results in muscle ischemia, and neovascularization is a route to increasing the perfusion in the tissue. The vascular endothelial growth factor (VEGF) family of potent pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9303-0

    authors: Mac Gabhann F,Ji JW,Popel AS

    更新日期:2007-06-01 00:00:00

  • The role of sugars in dendritic cell trafficking.

    abstract::Dendritic cells (DCs) are crucial components of the immune response, strategically positioned as immune sentinels. Complex trafficking and accurate positioning of DCs are indispensable for both immunity and tolerance. This is particularly evident for their therapeutic application where an unmet clinical need exists fo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0448-5

    authors: Silva Z,Konstantopoulos K,Videira PA

    更新日期:2012-04-01 00:00:00

  • Concussion Risk Between Individual Football Players: Survival Analysis of Recurrent Events and Non-events.

    abstract::Concussion tolerance and head impact exposure are highly variable among football players. Recent findings highlight that head impact data analyses need to be performed at the subject level. In this paper, we describe a method of characterizing concussion risk between individuals using a new survival analysis technique...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02675-x

    authors: Rowson S,Campolettano ET,Duma SM,Stemper B,Shah A,Harezlak J,Riggen L,Mihalik JP,Brooks A,Cameron KL,Svoboda SJ,Houston MN,McAllister T,Broglio S,McCrea M

    更新日期:2020-11-01 00:00:00

  • Pulmonary vascular resistance and impedance in isolated mouse lungs: effects of pulmonary emboli.

    abstract::To study pulsatile pressure-flow rate relationships in the intact pulmonary vascular network of mice, we developed a protocol for measuring pulmonary vascular resistance and impedance in isolated, ventilated, and perfused mouse lungs. We used pulmonary emboli to validate the effect of vascular obstruction on resistanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9050-z

    authors: Tuchscherer HA,Webster EB,Chesler NC

    更新日期:2006-04-01 00:00:00

  • Micro-flow visualization of red blood cell-enhanced platelet concentration at sudden expansion.

    abstract::Microscopic steps and crevices are inevitable features within prosthetic blood-contacting devices. This study aimed to elucidate the thrombogenicity of the associated microscopic flow features by studying the transport of fluorescent platelet-sized particles in a suspension of red blood cells (RBCs) flowing through a ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9494-z

    authors: Zhao R,Marhefka JN,Shu F,Hund SJ,Kameneva MV,Antaki JF

    更新日期:2008-07-01 00:00:00

  • Historic and future development of high-frequency ventilation.

    abstract::High-frequency ventilation (HFV) has not one but several histories. Proceeding along largely independent pathways are techniques using frequencies of 1-5 Hz and techniques using 10-40 Hz, the former being introduced by Sjostrand in 1971, the latter by Lunkenheimer in 1972. It was nearly ten years before it was recogni...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02407779

    authors: Bryan AC

    更新日期:1984-01-01 00:00:00

  • Multi-molecular gradients of permissive and inhibitory cues direct neurite outgrowth.

    abstract::Correct development of neuronal tracts requires the coordination of multiple permissive and inhibitory signals. By generating an in vitro microenvironment using soft lithography and microfluidic techniques, multiple guidance cues can be presented in a spatially defined way. Here we evaluated how neurites of dorsal roo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9486-z

    authors: Li GN,Liu J,Hoffman-Kim D

    更新日期:2008-06-01 00:00:00

  • Enhancement of stent-induced thromboembolism by residual stenoses: contribution of hemodynamics.

    abstract::In vitro stent-induced thromboembolism was altered by the presence of residual stenoses placed upstream or placed upstream and downstream of the stent. Heparinized (3 micro/ml) bovine blood was gravity fed through a conduit with a deployed coronary stent. Embolism was continuously monitored using a light-scattering mi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.243

    authors: Sukavaneshvar S,Rosa GM,Solen KA

    更新日期:2000-02-01 00:00:00