Antithrombotic Protein Filter Composed of Hybrid Tissue-Fabric Material has a Long Lifetime.

Abstract:

:There are recent reports of hybrid tissue-fabric materials with good performance-high biocompatibility and high mechanical strength. In this study, we demonstrate the capability of a hybrid material as a long-term filter for blood proteins. Polyester fabrics were implanted into rats to fabricate hybrid tissue-fabric material sheets. The hybrid materials comprised biological tissue grown on the fabric. The materials were extracted from the rat's body, approximately 100 days post-implantation. The tissues were decellularized to prevent immunological rejection. An antithrombogenicity test was performed by dropping blood onto the hybrid material surface. The hybrid material showed lesser blood coagulation than polysulfone and cellulose. Blood plasma was filtered using the hybrid material to evaluate the protein removal percentage and the lifetime of the hybrid material in vitro. The hybrid material showed a comparable performance to conventional filters for protein removal. Moreover, the hybrid material could work as a protein filter for 1 month, which is six times the lifetime of polysulfone.

journal_name

Ann Biomed Eng

authors

Inoue Y,Yokota T,Sekitani T,Kaneko A,Woo T,Kobayashi S,Shibuya T,Tanaka M,Kosukegawa H,Saito I,Isoyama T,Abe Y,Yambe T,Someya T,Sekino M

doi

10.1007/s10439-016-1781-5

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

1352-1364

issue

5

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-016-1781-5

journal_volume

45

pub_type

杂志文章
  • Monitoring Bone Tissue Engineered (BTE) Constructs Based on the Shifting Metabolism of Differentiating Stem Cells.

    abstract::Ever-increasing demand for bone grafts necessitates the realization of clinical implementation of bone tissue engineered constructs. The predominant hurdle to implementation remains to be securing FDA approval, based on the lack of viable methods for the rigorous monitoring of said constructs. The study presented here...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1937-y

    authors: Simmons AD,Sikavitsas VI

    更新日期:2018-01-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • Modeling Human Volunteers in Multidirectional, Uni-axial Sled Tests Using a Finite Element Human Body Model.

    abstract::A goal of the Human Research Program at National Aeronautics and Space Administration (NASA) is to analyze and mitigate the risk of occupant injury due to dynamic loads. Experimental tests of human subjects and biofidelic anthropomorphic test devices provide valuable kinematic and kinetic data related to injury risk e...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02147-3

    authors: Gaewsky JP,Jones DA,Ye X,Koya B,McNamara KP,Gayzik FS,Weaver AA,Putnam JB,Somers JT,Stitzel JD

    更新日期:2019-02-01 00:00:00

  • Resistances and compliances of a compartmental model of the cerebrovascular system.

    abstract::A lumped parameter compartmental model for the nonsteady flow of the cerebrovascular fluid is constructed. The model assumes constant resistances that relate fluid flux to pressure gradients, and compliances between compartments that relate fluid accumulation to rate of pressure changes. Resistances are evaluated by u...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364270

    authors: Sorek S,Bear J,Karni Z

    更新日期:1989-01-01 00:00:00

  • Muscle-tendon model with length history-dependent activation-velocity coupling.

    abstract::We developed muscle-tendon models incorporating Hill-type structure and length-dependent coupling between activation and velocity. The models were evaluated in electrically stimulated cat soleus muscles. Dynamic model parameters were estimated by a nonlinear parameter estimation algorithm from input-output data obtain...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.93

    authors: Shue GH,Crago PE

    更新日期:1998-05-01 00:00:00

  • Two methods for calculating the responses of photoreceptors to moving objects.

    abstract::The responses of photoreceptor cells to moving stimuli are crucial to understanding motion detection in visual systems. However, these responses are not well characterized quantitatively because they result from a combination of spatial optical behavior in the lens systems with temporal behavior in the phototransducti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.58

    authors: Korenberg MJ,Juusola M,French AS

    更新日期:1998-03-01 00:00:00

  • A Novel Approach to Utilize Icariin as Icariin-Derived ECM on Small Intestinal Submucosa Scaffold for Bone Repair.

    abstract::Icariin (Ic) has been demonstrated as a potent osteoinductive compound for bone tissue engineering. However, toxic side effects of the drug and poor biocompatibility of drug delivery systems (DDSs) still limit its application for bone repair in the clinic. To overcome these disadvantages and utilize the osteoinductivi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1900-y

    authors: Li M,Zhang C,Zhong Y,Zhao J

    更新日期:2017-11-01 00:00:00

  • Therapeutic effects of functional electrical stimulation on gait in individuals post-stroke.

    abstract::Functional electrical stimulation (FES) to lower extremity (LE) muscles is used by individuals post-stroke as an alternative to mechanical orthotic devices during gait or as a training modality during rehabilitation. Technological developments which improve the feasibility, accessibility and effectiveness of FES syste...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1148-8

    authors: Kafri M,Laufer Y

    更新日期:2015-02-01 00:00:00

  • A long-memory model of motor learning in the saccadic system: a regime-switching approach.

    abstract::Maintenance of movement accuracy relies on motor learning, by which prior errors guide future behavior. One aspect of this learning process involves the accurate generation of predictions of movement outcome. These predictions can, for example, drive anticipatory movements during a predictive-saccade task. Predictive ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-012-0669-2

    authors: Wong AL,Shelhamer M

    更新日期:2013-08-01 00:00:00

  • Personalized Perioperative Multi-scale, Multi-physics Heart Simulation of Double Outlet Right Ventricle.

    abstract::For treatment of complex congenital heart disease, computer simulation using a three-dimensional heart model may help to improve outcomes by enabling detailed preoperative evaluations. However, no highly integrated model that accurately reproduces a patient's pathophysiology, which is required for this simulation has ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02488-y

    authors: Kariya T,Washio T,Okada JI,Nakagawa M,Watanabe M,Kadooka Y,Sano S,Nagai R,Sugiura S,Hisada T

    更新日期:2020-06-01 00:00:00

  • Optimization of pulse train duration for the electrical stimulation of a skeletal muscle ventricle in the dog.

    abstract::The optimal means of electrically stimulating a skeletal muscle to contract around a fluid-filled pouch (i.e., a skeletal muscle ventricle [SMV]) has not been determined. A SMV was made from the latissimus dorsi muscle in five dogs and the rectus abdominis muscle in five dogs, and each SMV was electrically stimulated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364611

    authors: Badylak SF,Wessale JE,Geddes LA,Janas W

    更新日期:1990-01-01 00:00:00

  • Cardiac Multi-detector CT Segmentation Based on Multiscale Directional Edge Detector and 3D Level Set.

    abstract::Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10439-015-1422-4

    authors: Antunes S,Esposito A,Palmisano A,Colantoni C,Cerutti S,Rizzo G

    更新日期:2016-05-01 00:00:00

  • Tumor anti-angiogenic gene therapy with microencapsulated recombinant CHO cells.

    abstract::Microencapsulation of recombinant cells is a novel promising approach to tumor therapy in which therapeutic protein is sustainable and long-term delivered by microencapsulated cells. The semi-permeable membrane of microcapsule can protect cell from host's immune rejection, increase the chemical stability of therapeuti...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9255-4

    authors: Zhang Y,Wang W,Zhou J,Yu W,Zhang X,Guo X,Ma X

    更新日期:2007-04-01 00:00:00

  • Inverse parameter fitting of biological tissues: a response surface approach.

    abstract::In this paper, we present the application of a semi-global inverse method for determining material parameters of biological tissues. The approach is based on the successive response surface method, and is illustrated by fitting constitutive parameters to two nonlinear anisotropic constitutive equations, one for aortic...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8338-3

    authors: Einstein DR,Freed AD,Stander N,Fata B,Vesely I

    更新日期:2005-12-01 00:00:00

  • Evaluation of three animal models for concussion and serious brain injury.

    abstract::Three animal models were evaluated in this study involving head impacts of the rat, including the Marmarou drop-weight and two momentum-exchange techniques. In series 1, 36 Wistar rats were hit on the side of the free-moving head using Marmarou's 450 g impact mass at 4.4, 5.4, and 6.3 m/s. Head acceleration was measur...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0386-2

    authors: Viano DC,Hamberger A,Bolouri H,Säljö A

    更新日期:2012-01-01 00:00:00

  • Particle motion within in vitro models of stenosed internal carotid and left anterior descending coronary arteries.

    abstract::Asymmetric 75% and 95% area reduction, transparent Sylgard stenotic models were operated under internal carotid artery (ICA) [Womersley parameter, alpha=5.36, Re(mean) =213 and 180, respectively, and Re(peak)=734 and 410, respectively] and left anterior descending coronary artery (LAD) flow wave forms (alpha=2.65, Re(...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.131

    authors: Cao J,Rittgers SE

    更新日期:1998-03-01 00:00:00

  • Accuracy of Functional and Predictive Methods to Calculate the Hip Joint Center in Young Non-pathologic Asymptomatic Adults with Dual Fluoroscopy as a Reference Standard.

    abstract::Predictions from biomechanical models of gait may be sensitive to joint center locations. Most often, the hip joint center (HJC) is derived from locations of reflective markers adhered to the skin. Here, predictive techniques use regression equations of pelvic anatomy to estimate the HJC, whereas functional methods tr...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-015-1522-1

    authors: Fiorentino NM,Kutschke MJ,Atkins PR,Foreman KB,Kapron AL,Anderson AE

    更新日期:2016-07-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • 3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

    abstract::Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide va...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-016-1678-3

    authors: Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

    更新日期:2017-01-01 00:00:00

  • Permeability of endothelial and astrocyte cocultures: in vitro blood-brain barrier models for drug delivery studies.

    abstract::The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. To seek for in vitro BBB models that are more accessible than animals for investigating drug transport across the BBB, we compared four in vitro cultured cell models: endothelial monoculture (bEnd3 cell line), coculture of bEnd3 and prim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0023-5

    authors: Li G,Simon MJ,Cancel LM,Shi ZD,Ji X,Tarbell JM,Morrison B 3rd,Fu BM

    更新日期:2010-08-01 00:00:00

  • Theory of the oscillometric maximum and the systolic and diastolic detection ratios.

    abstract::It is proposed that the maximum in cuff pressure oscillations during oscillometry is due to the buckling of the brachial artery under a cuff. This theory is investigated by means of a mathematical model of oscillatometry that includes the mechanics of the occlusive arm cuff, the arterial pressure pulse waveform, and t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368225

    authors: Drzewiecki G,Hood R,Apple H

    更新日期:1994-01-01 00:00:00

  • Kinematic analysis of the human temporomandibular joint.

    abstract::A kinematic analysis of the temporomandibular joint (TMJ) is developed to determine the range of motion of the mandible during normal opening and during special motions required for arthroscopic surgery. The translation of the mandible is restricted by the constraint of the ligaments. By accounting for the maximum all...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368648

    authors: Kang QS,Updike DP,Salathe EP

    更新日期:1993-11-01 00:00:00

  • The effect of visual and sensory performance on head impact biomechanics in college football players.

    abstract::The development of prevention strategies is critical to address the rising prevalence of sport-related concussions. Visual and sensory performance may influence an individual's ability to interpret environmental cues, anticipate opponents' actions, and create appropriate motor responses limiting the severity of an imp...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-013-0881-8

    authors: Harpham JA,Mihalik JP,Littleton AC,Frank BS,Guskiewicz KM

    更新日期:2014-01-01 00:00:00

  • A preliminary physiologically based pharmacokinetic model for naphthalene and naphthalene oxide in mice and rats.

    abstract::Naphthalene is a toxicant with unusual species and tissue specificity that has been the subject of in vitro studies. We describe a preliminary physiologically based pharmacokinetic (PBPK) model for naphthalene constructed solely from in vitro data for comparison to animal data without the use of adjustable parameters....

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02667357

    authors: Sweeney LM,Shuler ML,Quick DJ,Babish JG

    更新日期:1996-03-01 00:00:00

  • Neurite outgrowth on a DNA crosslinked hydrogel with tunable stiffnesses.

    abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9530-z

    authors: Jiang FX,Yurke B,Firestein BL,Langrana NA

    更新日期:2008-09-01 00:00:00

  • Selective stimulation of latissimus dorsi muscle for cardiac assist.

    abstract::The contractile power of the latissimus dorsi muscle (LDM) is used in skeletal muscle cardiac assist (SMCA) to augment the blood pumping ability of a failing heart. The LDM has three anatomically distinct, independently innervate segments-the transverse, oblique, and lateral. There are potential advantages to selectiv...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.164

    authors: Thompson DR,Michele JJ,Cheever EA,George DT

    更新日期:1999-01-01 00:00:00

  • Estimation of Reynolds shear stresses during pulsatile flow in the region of aortic valves.

    abstract::Some investigators have attempted to estimate the Reynolds shear stress on the basis of a single component of velocity. The purpose of this investigation is to determine the validity of such estimates in a complex flow field, such as occurs in the cardiovascular system in the region of the aortic valve. Turbulent velo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02371247

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1985-01-01 00:00:00

  • Left-right asymmetry of visual evoked potentials in brain-damaged patients: a mathematical model and experimental results.

    abstract::The left-right asymmetry in the potential amplitude on the scalp was studied in poststroke patients by using flash visual evoked potential (VEP) and a numerical two-dimensional model of the head. The left-right asymmetry of the VEP was measured in three patients after thrombosis, in one after hemorrhage, and in one he...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02770997

    authors: Abboud S,Bar L,Rosenfeld M,Ring H,Glass I

    更新日期:1996-01-01 00:00:00

  • The effects of anisotropy on the stress analyses of patient-specific abdominal aortic aneurysms.

    abstract::The local dilation of the infrarenal abdominal aorta, termed an abdominal aortic aneurysm (AAA), is often times asymptomatic and may eventually result in rupture-an event associated with a significant mortality rate. The estimation of in-vivo stresses within AAAs has been proposed as a useful tool to predict the likel...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9490-3

    authors: Vande Geest JP,Schmidt DE,Sacks MS,Vorp DA

    更新日期:2008-06-01 00:00:00

  • Coupled Modeling of Lipid Deposition, Inflammatory Response and Intraplaque Angiogenesis in Atherosclerotic Plaque.

    abstract::We propose a multiphysical mathematical model by fully coupling lipid deposition, monocytes/macrophages recruitment and angiogenesis to investigate the pathophysiological responses of an atherosclerotic plaque to the dynamic changes in the microenvironment. The time evolutions of cellular (endothelial cells, macrophag...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02173-1

    authors: Guo M,Cai Y,He C,Li Z

    更新日期:2019-02-01 00:00:00