3D Printing of Calcium Phosphate Ceramics for Bone Tissue Engineering and Drug Delivery.

Abstract:

:Additive manufacturing, also known as 3D printing, has emerged over the past 3 decades as a disruptive technology for rapid prototyping and manufacturing. Vat polymerization, powder bed fusion, material extrusion, and binder jetting are distinct technologies of additive manufacturing, which have been used in a wide variety of fields, including biomedical research and tissue engineering. The ability to print biocompatible, patient-specific geometries with controlled macro- and micro-pores, and to incorporate cells, drugs and proteins has made 3D-printing ideal for orthopaedic applications, such as bone grafting. Herein, we performed a systematic review examining the fabrication of calcium phosphate (CaP) ceramics by 3D printing, their biocompatibility in vitro, and their bone regenerative potential in vivo, as well as their use in localized delivery of bioactive molecules or cells. Understanding the advantages and limitations of the different 3D printing approaches, CaP materials, and bioactive additives through critical evaluation of in vitro and in vivo evidence of efficacy is essential for developing new classes of bone graft substitutes that can perform as well as autografts and allografts or even surpass the performance of these clinical standards.

journal_name

Ann Biomed Eng

authors

Trombetta R,Inzana JA,Schwarz EM,Kates SL,Awad HA

doi

10.1007/s10439-016-1678-3

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

23-44

issue

1

eissn

0090-6964

issn

1573-9686

pii

10.1007/s10439-016-1678-3

journal_volume

45

pub_type

杂志文章,评审
  • Utilizing Atlas-Based Modeling to Predict Knee Joint Cartilage Degeneration: Data from the Osteoarthritis Initiative.

    abstract::Currently, there are no clinically available tools or applications which could predict osteoarthritis development. Some computational models have been presented to simulate cartilage degeneration, but they are not clinically feasible due to time required to build subject-specific knee models. Therefore, the objective ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02184-y

    authors: Mononen ME,Liukkonen MK,Korhonen RK

    更新日期:2019-03-01 00:00:00

  • Hemodynamic Influence on Smooth Muscle Cell Kinetics and Phenotype During Early Vein Graft Adaptation.

    abstract::Pathologic vascular adaptation following local injury is the primary driver for accelerated intimal hyperplasia and an occlusive phenotype. Smooth muscle cell (SMC) proliferation within the wall, and migration into the developing intima, is a major component of this remodeling response. The primary objective in the cu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1725-0

    authors: Klein B,Destephens A,Dumeny L,Hu Q,He Y,O'Malley K,Jiang Z,Tran-Son-Tay R,Berceli S

    更新日期:2017-03-01 00:00:00

  • Permeability of endothelial and astrocyte cocultures: in vitro blood-brain barrier models for drug delivery studies.

    abstract::The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. To seek for in vitro BBB models that are more accessible than animals for investigating drug transport across the BBB, we compared four in vitro cultured cell models: endothelial monoculture (bEnd3 cell line), coculture of bEnd3 and prim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0023-5

    authors: Li G,Simon MJ,Cancel LM,Shi ZD,Ji X,Tarbell JM,Morrison B 3rd,Fu BM

    更新日期:2010-08-01 00:00:00

  • Delayed activation and retrograde propagation in cardiac muscle: implication of virtual electrode effects.

    abstract::Point cathodal stimulation of cardiac tissue was shown previously to produce both a dog-bone shaped virtual cathode transverse to the muscle fibers and two longitudinal virtual anodes. We hypothesize that virtual anodes can cause a region of delayed activation, separating two regions of early activation caused by the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1326029

    authors: Wu J,Roden DM,Wikswo JP Jr

    更新日期:2000-11-01 00:00:00

  • Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods.

    abstract::Three-dimensional (3D) measurement of the spine can provide important information for functional, developmental, diagnostic, and treatment-effect evaluations. However, existing measurement techniques are either 2-dimensional, highly invasive, or involve a high radiation dose, prohibiting their widespread and repeated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1599-1

    authors: Koo TK,Kwok WE

    更新日期:2016-10-01 00:00:00

  • Are DXA/aBMD and QCT/FEA Stiffness and Strength Estimates Sensitive to Sex and Age?

    abstract::Dual X-ray absorptiometry (DXA) measures areal bone mineral density (aBMD) by simplifying a complex 3D bone structure to a 2D projection and is not equally effective for explaining fracture strength in women and men. Unlike DXA, subject-specific quantitative computed tomography-based finite element analysis (QCT/FEA) ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1914-5

    authors: Rezaei A,Giambini H,Rossman T,Carlson KD,Yaszemski MJ,Lu L,Dragomir-Daescu D

    更新日期:2017-12-01 00:00:00

  • Identification of static and dynamic components of reflex sensitivity in spastic elbow flexors using a muscle activation model.

    abstract::Static and dynamic components of the stretch reflex were studied in elbow flexors of 13 hemiparetic brain-injured individuals. Constant-velocity joint rotations were applied to the elbow, and the resulting stretch reflex torque and electromyographic responses were recorded in the biceps brachii and brachioradialis mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1359496

    authors: Schmit BD,Rymer WZ

    更新日期:2001-04-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • Mechanical & cell culture properties of elastin-like polypeptide, collagen, bioglass, and carbon nanosphere composites.

    abstract::Collagen, the most commonly used extra-cellular matrix protein for tissue engineering applications, displays poor mechanical properties. Here, we report on the preparation and characterization of novel multi-component composite systems that incorporate a genetically engineered, biocompatible polymer (elastin-like poly...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0825-3

    authors: Wheeler TS,Sbravati ND,Janorkar AV

    更新日期:2013-10-01 00:00:00

  • Spectral analysis of Doppler flow velocity signals: assessment of objectives, methods, and interpretation.

    abstract::The objective of this paper is to review the theoretical basis and clinical application of electrical impedance plethysmography in the noninvasive evaluation of peripheral arterial and venous disease. Theoretical, experimental and clinical studies have not demonstrated a direct relationship between electrical impedanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02410294

    authors: Zuech PE,Cobbold RS,Johnston KW,Kassam M

    更新日期:1984-01-01 00:00:00

  • Transport Analysis of Engineered Liver Tissue Fabricated Using a Capsule-Based, Modular Approach.

    abstract::The bioinspired, microscale tissue engineering approach has emerged in recent years as a promising alternative to preformed scaffolds. Using this approach, complex tissues and organs can be efficiently engineered from microscale modules to replicate the intricate architecture and physiology of vascularized organs and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02192-y

    authors: Annamalai RT,Matthew HWT

    更新日期:2019-05-01 00:00:00

  • Monitoring Bone Tissue Engineered (BTE) Constructs Based on the Shifting Metabolism of Differentiating Stem Cells.

    abstract::Ever-increasing demand for bone grafts necessitates the realization of clinical implementation of bone tissue engineered constructs. The predominant hurdle to implementation remains to be securing FDA approval, based on the lack of viable methods for the rigorous monitoring of said constructs. The study presented here...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1937-y

    authors: Simmons AD,Sikavitsas VI

    更新日期:2018-01-01 00:00:00

  • Population-Based Bone Strain During Physical Activity: A Novel Method Demonstrated for the Human Femur.

    abstract::Statistical methods are increasingly used in biomechanics for studying bone geometry, bone density distribution and function in the population. However, relating population-based bone variation to strain during activity is computationally challenging. Here, we describe a new method for calculating strain in a populati...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02483-3

    authors: Ziaeipoor H,Taylor M,Martelli S

    更新日期:2020-06-01 00:00:00

  • Detergent-Based Decellularization of Bovine Carotid Arteries for Vascular Tissue Engineering.

    abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-017-1892-7

    authors: Daugs A,Hutzler B,Meinke M,Schmitz C,Lehmann N,Markhoff A,Bloch O

    更新日期:2017-11-01 00:00:00

  • Prediction of the biomechanical effects of compression therapy on deep veins using finite element modelling.

    abstract::Clinicians generally assume that Medical Compression Stockings (MCS) work by reducing vein luminal diameter and, in this way, help to prevent blood pooling. Conflicting results have been reported however in the case of lower leg deep veins which call into question this hypothesis. The purpose of this contribution is t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1121-6

    authors: Rohan PY,Badel P,Lun B,Rastel D,Avril S

    更新日期:2015-02-01 00:00:00

  • Influence of autoregressive model parameter uncertainty on spectral estimates of heart rate dynamics.

    abstract::Linear autoregressive (AR) model-based heart rate (HR) spectral analysis has been widely used to study HR dynamics. Owing to system and measurement noise, the parameters of an AR model have intrinsic statistical uncertainty. In this study, we evaluate how this AR parameter uncertainty can translate to uncertainty in H...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368320

    authors: Christini DJ,Kulkarni A,Rao S,Stutman ER,Bennett FM,Hausdorff JM,Oriol N,Lutchen KR

    更新日期:1995-03-01 00:00:00

  • A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

    abstract::The objective of this study was to develop a ferrocene mediated glucose biosensor for reverse iontophoresis. An amperometric ferrocene mediated glucose biosensor based on a three electrodes planar configuration was constructed using screen printing technique. Different combinations of glucose oxidase and ferrocene loa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9918-4

    authors: Ching CT,Sun TP,Huang SH,Shieh HL,Chen CY

    更新日期:2010-04-01 00:00:00

  • A review of return to play issues and sports-related concussion.

    abstract::Mild traumatic brain injury in sports has become a significant public health concern which has not only received the general public's attention through multiple news media stories involving athletic concussions, but has also resulted in local, state, and national legislative efforts to improve recognition and manageme...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-011-0413-3

    authors: Doolan AW,Day DD,Maerlender AC,Goforth M,Gunnar Brolinson P

    更新日期:2012-01-01 00:00:00

  • Biased cell migration of fibroblasts exhibiting contact guidance in oriented collagen gels.

    abstract::We present here the first quantitative correlation for cell contact guidance in an oriented fibrillar network in terms of biased cell migration. The correlation is between the anisotropic cell diffusion parameter, DA = Dx/Dy, and the collagen gel birefringence, delta n, a measure of axially biased collagen fibril orie...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368241

    authors: Dickinson RB,Guido S,Tranquillo RT

    更新日期:1994-07-01 00:00:00

  • Net change in periosteal strain during stance shift loading after surgery correlates to rapid de novo bone generation in critically sized defects.

    abstract::In an ovine femur model, proliferative woven bone fills critically sized defects enveloped by periosteum within 2 weeks of treatment with the one-stage bone-transport surgery. We hypothesize that mechanical loading modulates this process. Using high-definition optical strain measurements we determined prevailing perio...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0242-9

    authors: McBride SH,Dolejs S,Brianza S,Knothe U,Knothe Tate ML

    更新日期:2011-05-01 00:00:00

  • Computer modeling of red blood cell rheology in the microcirculation: a brief overview.

    abstract::One of the major functions of the cardiovascular system is to deliver blood to the microcirculation where exchange of mass and energy can take place. In the present article, we will provide an overview of the state-of-the-art computational methods for modeling of red blood cell (RBC) rheology and dynamics in the micro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-8776-y

    authors: Cristini V,Kassab GS

    更新日期:2005-12-01 00:00:00

  • Enhancement of stent-induced thromboembolism by residual stenoses: contribution of hemodynamics.

    abstract::In vitro stent-induced thromboembolism was altered by the presence of residual stenoses placed upstream or placed upstream and downstream of the stent. Heparinized (3 micro/ml) bovine blood was gravity fed through a conduit with a deployed coronary stent. Embolism was continuously monitored using a light-scattering mi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.243

    authors: Sukavaneshvar S,Rosa GM,Solen KA

    更新日期:2000-02-01 00:00:00

  • Design Considerations of a Fiber Optic Pressure Sensor Protective Housing for Intramuscular Pressure Measurements.

    abstract::Intramuscular pressure (IMP), defined as skeletal muscle interstitial fluid pressure, reflects changes in individual muscle tension and may provide crucial insight into musculoskeletal biomechanics and pathologies. IMP may be measured using fiber-optic fluid pressure sensors, provided the sensor is adequately anchored...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1703-6

    authors: Go SA,Jensen ER,O'Connor SM,Evertz LQ,Morrow DA,Ward SR,Lieber RL,Kaufman KR

    更新日期:2017-03-01 00:00:00

  • Length-Change Patterns of the Collateral Ligaments During Functional Activities After Total Knee Arthroplasty.

    abstract::This study aimed to quantify the elongation patterns of the collateral ligaments following TKA during functional activities of daily living. Using mobile video-fluoroscopy to capture radiographic images of the knee in a group of six patients, each with an ultra-congruent knee implant, tibiofemoral kinematics were reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02459-3

    authors: Hosseini Nasab SH,Smith CR,Schütz P,Damm P,Trepczynski A,List R,Taylor WR

    更新日期:2020-04-01 00:00:00

  • Multidirectional pelvic floor muscle strength measurement.

    abstract::Pelvic floor muscle (PFM) strength measurement provides useful information for the study of pelvic floor dysfunctions. Vaginal digital palpation, intravaginal pressure measurements, and the use of a dynamometric speculum represent currently available clinical methods for evaluating PFM strength. However, none of these...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9728-8

    authors: Saleme CS,Rocha DN,Del Vecchio S,Silva Filho AL,Pinotti M

    更新日期:2009-08-01 00:00:00

  • Countercurrent extraction of sparingly soluble gases for membrane introduction mass spectrometry.

    abstract::Membrane introduction mass spectrometry has been applied to inert gas measurements in blood and tissue, but gases with low blood solubility are associated with reduced sensitivity. Countercurrent extraction of inert gases from a blood sample into a water carrier phase has the potential to extract most of the gas sampl...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684170

    authors: Baumgardner JE,Neufeld GR

    更新日期:1997-09-01 00:00:00

  • Effects of training on human tracking of electrocutaneous signals.

    abstract::The effects of training on a person's ability to perceive, interpret and utilize information presented via the tactile sense were examined by using a dual-channel electrocutaneous tracking approach. The electrocutaneous code studied was linear pulse rate encoding of information. The stimulus had a pulse width of 200 m...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367409

    authors: Szeto AY,Chung YM

    更新日期:1986-01-01 00:00:00

  • The air-conditioning capacity of the human nose.

    abstract::The nose is the front line defender of the respiratory system. Unsteady simulations in three-dimensional models have been developed to study transport patterns in the human nose and its overall air-conditioning capacity. The results suggested that the healthy nose can efficiently provide about 90% of the heat and the ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2513-4

    authors: Naftali S,Rosenfeld M,Wolf M,Elad D

    更新日期:2005-04-01 00:00:00

  • Magnetic (eddy-current) electroventilation in the dog.

    abstract::Magnetic (eddy-current) stimulation of the inspiratory motor nerves in the neck of the anesthetized dog was achieved. Using a 10-turn coil wound around the base of the neck and a train of pulses (25/s), inspiration was produced by tetanic contraction of the inspiratory muscles. The volume of air inspired increased wit...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368176

    authors: Geddes LA,Mouchawar G,Bourland JD,ElAbbady T,Nyenhuis J

    更新日期:1993-05-01 00:00:00

  • L-selectin shear thresholding modulates leukocyte secondary capture.

    abstract::Transient homotypic adhesions between flowing leukocytes and those previously adherent on the vessel wall has been proposed to amplify the accumulation of leukocytes at sites of inflammation. While adhesion of leukocytes to the vessel wall (primary capture) is mediated primarily by P-selectin on the endothelium and P-...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9468-1

    authors: Paschall CD,Lawrence MB

    更新日期:2008-04-01 00:00:00