Abstract:
:We developed muscle-tendon models incorporating Hill-type structure and length-dependent coupling between activation and velocity. The models were evaluated in electrically stimulated cat soleus muscles. Dynamic model parameters were estimated by a nonlinear parameter estimation algorithm from input-output data obtained during simultaneous random stimulation and length changes. Static parameters were estimated from the length-tension curve. A model with length history-dependent activation-velocity coupling predicted the behavior of the muscle under a wide variety of conditions, including during random perturbations and during isovelocity movements, where it captured short range stiffness and length history-dependent postyielding behavior. Furthermore, the model predicted twitch responses. The generality of this fixed parameter model makes it especially suitable for simulation and feedforward control, where muscle responses are not available for on-line parameter adaptation.
journal_name
Ann Biomed Engjournal_title
Annals of biomedical engineeringauthors
Shue GH,Crago PEdoi
10.1114/1.93subject
Has Abstractpub_date
1998-05-01 00:00:00pages
369-80issue
3eissn
0090-6964issn
1573-9686journal_volume
26pub_type
杂志文章abstract::An endovascular technique using a stent has been developed and successfully applied in the treatment of wide neck aneurysms. A stent can facilitate thrombosis in the aneurysm pouch while maintaining biocompatible passage of the parent artery. Insertion of the stent changes the flow characteristics inside the aneurysm ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1500406
更新日期:2002-07-01 00:00:00
abstract::In vitro and in vivo studies were conducted on omega-3 fatty acid-derived biomaterials to determine their utility as an implantable material for adhesion prevention following soft tissue hernia repair and as a means to allow for the local delivery of antimicrobial or antibiofilm agents. Naturally derived biomaterials ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1489-y
更新日期:2016-03-01 00:00:00
abstract::Naphthalene is a toxicant with unusual species and tissue specificity that has been the subject of in vitro studies. We describe a preliminary physiologically based pharmacokinetic (PBPK) model for naphthalene constructed solely from in vitro data for comparison to animal data without the use of adjustable parameters....
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02667357
更新日期:1996-03-01 00:00:00
abstract::In physiological conditions, joint function involves continuously moving contact areas over the tissue surface. Such moving contacts play an important role for the durability of the tissue. It is known that in pathological joints these motion paths and contact mechanics change. Nevertheless, limited information exists...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-015-1543-9
更新日期:2016-08-01 00:00:00
abstract::Past literature has provided evidence that a normal mechanical force environment of blood flow may guide normal development while an abnormal environment can lead to congenital malformations, thus warranting further studies on embryonic cardiovascular flow dynamics. In the current study, we developed a non-invasive 4D...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1882-9
更新日期:2017-10-01 00:00:00
abstract::This paper describes a finite volume method for modeling electrical activation in a sample of cardiac tissue using the bidomain equations. Microstructural features to the level of cleavage planes between sheets of myocardial fibers in the tissue are explicitly represented. The key features of this implementation compa...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-1434-6
更新日期:2005-05-01 00:00:00
abstract::We describe a system for real-time control of biological and other experiments. This device, based around the Real-Time Linux operating system, was tested specifically in the context of dynamic clamping, a demanding real-time task in which a computational system mimics the effects of nonlinear membrane conductances in...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1408929
更新日期:2001-10-01 00:00:00
abstract::Dendritic cells (DCs) are crucial components of the immune response, strategically positioned as immune sentinels. Complex trafficking and accurate positioning of DCs are indispensable for both immunity and tolerance. This is particularly evident for their therapeutic application where an unmet clinical need exists fo...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-011-0448-5
更新日期:2012-04-01 00:00:00
abstract::Poor vascular homeostasis drives many clinical disorders including diabetes, arthritis, atherosclerosis, and peripheral artery disease. Local tissue ischemia resultant of insufficient blood flow is a potent stimulus for recruitment of endothelial progenitor cells (EPCs). This mobilization and homing is a multi-step pr...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-015-1400-x
更新日期:2015-10-01 00:00:00
abstract::Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combi...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1495866
更新日期:2002-06-01 00:00:00
abstract::Maintenance of movement accuracy relies on motor learning, by which prior errors guide future behavior. One aspect of this learning process involves the accurate generation of predictions of movement outcome. These predictions can, for example, drive anticipatory movements during a predictive-saccade task. Predictive ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-012-0669-2
更新日期:2013-08-01 00:00:00
abstract::The ability to predict endothelial cell migration rates may aid in the design of biomaterials that endothelialize following implantation. However, the complexity of the signaling response to migration-promoting stimuli such as sphingosine 1-phosphate (S1P) makes such predictions quite challenging. A number of signalin...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0014-6
更新日期:2010-08-01 00:00:00
abstract::This study was undertaken to investigate the possible origin of some cutaneously recorded higher frequency electrogastrographic signals. Computer modeling of gastric electrical uncoupling was performed using previously described conoidal dipole model. Cutaneous electrogastrograms were simulated after uncoupling was in...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:
更新日期:1997-11-01 00:00:00
abstract::Uncomplicated acute type B aortic dissections are usually treated medically, but they can become acutely complicated by rapid expansion, rupture and malperfusion syndromes and in the longer term by chronic dilatation and aortic aneurysm formation. The objective of this study is to use computational fluid dynamics reco...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1075-8
更新日期:2015-01-01 00:00:00
abstract::This paper reviews the applications of accelerometers on the detection of physiological acoustic signals such as heart sounds, respiratory sounds, and gastrointestinal sounds. These acoustic signals contain a rich reservoir of vital physiological and pathological information. Accelerometer-based systems enable continu...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章,评审
doi:10.1007/s10439-014-1111-8
更新日期:2014-11-01 00:00:00
abstract::In this study, we have developed an integrated microfluidic platform for actively patterning mammalian cells, where poly(ethylene glycol) (PEG) hydrogels play two important roles as a non-fouling layer and a dielectric structure. The developed system has an embedded array of PEG microwells fabricated on a planar indiu...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-010-0108-1
更新日期:2010-12-01 00:00:00
abstract::Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However,...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/b:abme.0000036640.11387.4b
更新日期:2004-08-01 00:00:00
abstract::Vascular smooth muscle mechanics have been studied in vitro in cylindrical segments of dog carotid artery, human internal mammary artery, and human saphenous vein. Such cylindrical preparations maintain normal vessel geometry and also permit correlation of mechanical phenomena with transmural pressure. These studies s...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02363919
更新日期:1984-01-01 00:00:00
abstract::Modern models of cardiac membranes are often highly complex and computationally expensive, particularly when used in long simulations of spatially extended models of cardiac tissue. Therefore, there is a need for simpler membrane models that preserve the features of the complex models deemed important. This communicat...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-3948-3
更新日期:2005-07-01 00:00:00
abstract::Mechanical cues arising from extracellular matrices greatly affect cellular properties, and hence, are of significance in designing biomaterials. In this study, a DNA crosslinked hydrogel was employed to examine cellular responses of spinal cord neurons to substrate compliances. Using DNA as crosslinkers in polymeric ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-008-9530-z
更新日期:2008-09-01 00:00:00
abstract::While viscoelastic responses of isolated trunk soft tissues have been characterized in earlier studies, the effects of external loading and flexion rate on these responses in the intact human trunk are largely unknown. Two experiments were conducted to measure trunk viscoelastic behaviors, one involving prolonged flex...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-013-0797-3
更新日期:2013-06-01 00:00:00
abstract::Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell dama...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-014-1008-6
更新日期:2014-06-01 00:00:00
abstract::Vascular diseases are an increasing health issue, and common alloplastic, allogenic or autologous vascular grafts show frequent complications. The aim of this study is to develop an acellular, xenogenic bypass-graft from a bovine carotid artery (BAC) using detergent-based protocols. We compared decellularization with ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-017-1892-7
更新日期:2017-11-01 00:00:00
abstract::To study the effects of compressive straining on muscle cell deformation and damage an in vitro model system was developed. Myoblasts were seeded in agarose constructs and cultured in growth medium for 4 days. Subsequently, the cells were allowed to fuse into multinucleated myotubes for 8 days in differentiation mediu...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.1349698
更新日期:2001-02-01 00:00:00
abstract::We present a method for the localized statistical discrimination of class populations based on the Karhunen-Loève and Fukunaga-Koontz transforms. These transforms provide features that model the variance of a sample distribution. The spatial series of a 196 channel epicardial electrogram recording from an arrythmogeni...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/BF02367084
更新日期:1994-09-01 00:00:00
abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-005-5788-6
更新日期:2005-10-01 00:00:00
abstract::The Veterans Health Administration determined that over 250,000 U.S. service members were diagnosed with a traumatic brain injury (TBI) between 2008 and 2018, of which a great proportion were due to blast exposure. Although the penetrating (secondary) and inertia-driven (tertiary) phases of blast-induced TBI (bTBI) ha...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-019-02437-4
更新日期:2020-04-01 00:00:00
abstract::This paper describes the development and use of a direct compression stimulator for culturing explants from the meniscus of the knee and articular cartilage. Following design and fabrication of the instrument along with its data acquisition system, the function of the machine was verified by both mechanical means and ...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-006-9157-x
更新日期:2006-09-01 00:00:00
abstract::A model predictive control strategy to simultaneously regulate hemodynamic and anesthetic variables in critical care patients is presented. A nonlinear canine circulatory model, which has been used to study the effect of inotropic and vasoactive drugs on hemodynamic variables, has been extended to include propofol pha...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1114/1.255
更新日期:2000-01-01 00:00:00
abstract::The relationship between laboratory and on-field performance of football helmets was assessed for 31 football helmet models selected from those worn by players in the 2015-2019 National Football League (NFL) seasons. Linear impactor tests were conducted with helmets placed on an instrumented Hybrid III head and neck a...
journal_title:Annals of biomedical engineering
pub_type: 杂志文章
doi:10.1007/s10439-020-02627-5
更新日期:2020-11-01 00:00:00